This configuration note is a standalone publication that provides instructions for installing,
configuring, and maintaining the Fast Ethernet/Ethernet Versatile Interface Processor
(VIP-FE-TX/4E) in your Cisco 7000 series and Cisco 7500 series routers.
The VIP-FE-TX/4E operates with the CxBus in the Cisco 7000 series and CyBus in the Cisco 7500
series, and requires that the host Cisco 7000 series and Cisco 7500 series router is running Cisco
Internetwork Operating System (Cisco IOS) Release 11.1(1) or later, or a Cisco-approved beta
version of Cisco IOS Release 11.1 or later.
Note The entire VIP-FE-TX/4E assembly, with port adapters installed, is a field-replaceable unit
(FRU). Individual port adapters are not available as spare parts.
Included are steps for VIP-FE-TX/4E hardware installation, and basic VIP configuration steps and
examples for configuring the individual interfaces on a new VIP.
• VIP Port Adapter Functions, page 29—this section contains subsections that discuss each port
adapter and its specific features, configuration and connection requirements, and functions
You need only refer to the information that is specific to your FE-TX and 4E port adapter or that
applies tospecific VIP functionality.Atable of contents is included on page 2 so you can more easily
find what you need.
Note For complete descriptions of interface subcommands and the configuration options available
for VIP-related interfaces, and which support VIP functionality, refer to the section “If You Need
More Information.”
This configuration note includes the following sections:
• If You Need More Information
• Versatile Interface Processor Functions, page 3
Note The following section contains important information about the latest Cisco IOS release.
— What is the VIP?, page 3
— VIP Software Prerequisites, page 5
— VIP Hardware Prerequisites, page 5
— What is the Cisco 7000 Family?, page 5
— VIP Port Adapter Hardware Configuration Overview, page 10
— VIP Microcode Overview, page 11
— VIP Installation Prerequisites, page 11
— VIP Installation, page 16
— Checking the Installation and Verifying VIP Status, page 19
— Upgrading VIP Microcode, page 23
— Upgrading and Replacing DRAM SIMMs, page 26
• VIP Port Adapter Functions, page 29
— FE-TX Port Adapter, page 29
— 4E Port Adapter, page 44
• SELV Circuit Warning Translations, page 57
• Cisco Information Online, page 58
If You Need More Information
The Cisco Internetwork Operating System (Cisco IOS) software running the router contains
extensivefeatures and functionality.The effective use of many of many of these features is easier if
you have more information at hand.
To obtain general information about documentation, call Customer Service at 800 553-6387 or
408 526-7208. Customer Service hours are 5:00 a.m. to 6:00 p.m. Pacific time, Monday through
Friday (excluding companyholidays). You can also send e-mail to cs-rep@cisco.com. You can also
refer to the Cisco Information Packet that shipped with your router.
2 VIP-FE-TX/4E Installation and Configuration
Page 3
Versatile Interface Processor Functions
For additional information on configuring the Cisco 7000 series or Cisco 7500 series routers, the
following documentation resources are available to you:
• UniverCD
This publication and all other Cisco Systems publications are available on UniverCD, which is
Cisco’s online library of product information. UniverCD is updated and shipped monthly, so it
might be more up to date than printed documentation. Toorder UniverCD,contact a Cisco Sales
or Customer Service representative.
• For systems with Cisco IOS Release 11.1(1), a Cisco-approved 11.1 beta software version, or a
later Cisco IOS release, refer to the following modular configuration and modular command
reference publications, as appropriate for your configuration:
— Configuration Fundamentals Configuration Guide
— Configuration Fundamentals Command Reference
— Wide-Area Networking Configuration Guide
— Wide-Area Networking Command Reference
— Standard Network Protocols Configuration Guide
— Standard Network Protocols Command Reference
— Network Protocols Configuration Guide
— Network Protocols Command Reference
— Bridging and IBM Networking Configuration Guide
— Bridging and IBM Networking Command Reference
— Configuration Builder Getting Started Guide
— Troubleshooting Internetworking Systems
Versatile Interface Processor Functions
The following sections describe the Versatile Interface Processor (VIP) and discuss VIP-specific
features and functions, such as installing and removing the VIP, installing and removing port
adapters, and using and configuring common VIP interface functions.
What is the VIP?
The VIP is a new interface processor for use with the Cisco 7000 series and Cisco 7500 series
routers, and it installs in the interface processor slots in your Cisco 7000 series or 7500 series router.
The VIP uses a single motherboard with up to two port adapters. The VIP port adapters provide the
individualLAN, WAN, or LAN/WAN interface ports. The VIP can be removedfrom a chassis while
power is on and the system is operating.
Caution The VIP supports online insertion and removal (OIR), which allows you to remove and
replacea VIPwithout first shuttingdown the system.Online insertion and removal maximizes router
availability by letting you add or remove VIPs during system operation; however, the system may
indicate a hardware failure if you fail to follow proper procedures. Tohelp avoid problems with the
installation, review the functional description in the section “Online Insertion and Removal—An
Overview” on page 13, and follow the VIP installation steps carefully.
VIP-FE-TX/4E Installation and Configuration 3
Page 4
Versatile Interface Processor Functions
Note The VIP port adapters themselves do not support OIR, nor are they FRUs.
The VIP uses a Reduced Instructions Set Computing (RISC), Mips 4600 processor for high
performance, and has an internal operating frequency of 100 megahertz (MHz) and a 50-MHz
system bus interface. The VIP has 8 megabytes (MB) of dynamic random access memory (DRAM)
as the default DRAM configuration.
Figure 1 shows a VIP-FE-TX/4E. The VIP firmware (microcode), which contains card-specific
software instructions, resides in a Flash memory device in socket location U17. For pinouts, refer to
the section “FE-TX Port Adapter Receptacles, Cables, and Pinouts” on page 33. Single in-line
memory modules contain the DRAM. You can install VIPs in any availableinterface processor slots
in your Cisco 7000 or Cisco 7500 series router.
Figure 1VIP with One FE-TX and One 4E Port Adapter (Product Number VIP-FE-TX/4E[=])
Bus connector
Microcode
handles not shown
Flash U17
U2
Port adapter
DRAM
SIMMs
U1
4E in port
FE-TX in
port adapter
adapter
slot 1
slot 0
MII
0
LINK
FAST ETHERNET
RJ45
0
1
2
3
LINK
1
3
0
2
ETHERNET-10BT
H4711
Note In the Cisco 7000, Cisco 7507 and Cisco 7513 chassis, the VIP is installed vertically. In the
Cisco 7010 and Cisco 7505 chassis, the VIP is installed horizontally. Port adapters have a handle
attached, but this handle is not shown to allow a full view of detail on each port adapter’s faceplate.
4 VIP-FE-TX/4E Installation and Configuration
Page 5
VIP Software Prerequisites
The VIP requires that the host Cisco 7000 series and Cisco 7500 series router is running Cisco
Internetwork Operating System (Cisco IOS) Release 11.1(1) or later, or a Cisco-approved beta
version of Cisco IOS Release 11.1 or later.
Note The latest Cisco IOS release is available via anonymous File Transfer Protocol (FTP) from
ftp/beta111_dir@ftp.cisco.com. Detailed information about the latest Cisco IOS release can be
found in the ASCII file vip1-readme, which is also available via FTP from ftp.cisco.com in the
directory /ftp/beta111_dir. This ASCII file includes information and instructions on how to get
the current Cisco IOS software images and VIP microcode. To access information located in Cisco
Information Online (CIO), refer to the section “SELV Circuit Warning Translations” at the end of
this publication.
VIP Hardware Prerequisites
The VIP operates with the CxBus in the Cisco 7000 series and CyBus in the Cisco 7500 series, and
operates with the optional RSP7000 and RSP7000CI RSP-based processor modules in the
Cisco 7000 series routers: Cisco 7000 and Cisco 7010. The VIP will also operate with the Route
Processor (RP) and Switch Processor (SP) in the Cisco 7000 series routers. The VIP operates with
all RSP-based processor modules currently shipping in the Cisco 7000 series and Cisco 7500 series
routers: Cisco 7505, Cisco 7507, and Cisco 7513.
Versatile Interface Processor Functions
What is the Cisco 7000 Family?
For the Cisco 7000 family of routers, which includes the Cisco 7000 series and Cisco 7500 series
routers, network interfacesreside onmodular interfaceprocessors, including the VIP,which provide
a direct connection between external networks and the high-speed CxBus in the Cisco 7000 series
and the high-speed CyBus in the Cisco 7500 series.
In all systems, the remaining slots support any combination of network interface types: Ethernet
attachment unit interface (AUI), Ethernet 10BASE-T, Fast Ethernet 100BASE-TX, Asynchronous
Transfer Mode (ATM), Token Ring, multichannel applications, Fiber Distributed Data Interface
(FDDI), channel attachment, serial, or High-Speed Serial Interface (HSSI), and all VIP–based
interfaces.
VIP-FE-TX/4E Installation and Configuration 5
Page 6
Versatile Interface Processor Functions
Cisco 7000 Series
Figure 2 and Figure 3 show the rear of the Cisco 7000 series routers: the seven-slot Cisco 7000 and
the five-slot Cisco 7010, respectively. In the Cisco 7000 series, two slots are reserved for the SP (or
SSP) and RP, or for the 7000 Series Route Switch Processor (RSP7000) and the 7000 Series Chassis
Interface (RSP7000CI). The remaining slots are for interface processors: slots 0 through 4 in the
Cisco 7000, and slots 0 through 2 in the Cisco 7010.
Figure 4, Figure 5, and Figure 6 show the rear of the Cisco 7500 series routers: the five-slot
Cisco 7505, the seven-slot Cisco 7507, and the thirteen-slot Cisco 7513, respectively.
In the Cisco 7505, one slot (4) is reserved for the Route Switch Processor (RSP1), which contains
the system processor and performs packet switching functions. Slots 0 through 3 are for interface
processors.
Figure 5 showsthe rear of the seven-slotCisco 7507 router.In the Cisco 7507, up to two slots (2 and
3) are reserved for the Route Switch Processor (RSP2), which contains the system processor and
performs packet switching functions. Slots 0 and 1 and 4 through 6 are for interface processors.
Figure 5Cisco 7507, Interface Processor End
aptive
stallation screw
pper
wer supply
DC FAIL
AC POWER
NORMAL
ENABLE
hassis
ounding
ceptacles
aptive
stallation screw
wer
wer supply
DC FAIL
AC POWER
EJECT
SLOT 1
I
O
I
O
Slot 0
SLOT 0
MASTER
SLAVE
SLAVE/MASTER
CPU HALT
RESET
AUX.
ROUTE SWITCH PROCESSOR 2
CONSOLE
2
1
34 5 6
ENABLE
H3888
RSP slots
8 VIP-FE-TX/4E Installation and Configuration
Page 9
Versatile Interface Processor Functions
Figure 6 shows the rear of the Cisco 7513 with two AC-input power supplies installed. Twoslots (6
and 7) are reserved for the second generation Route Switch Processor (RSP2), which contains the
system processor and performs packet switching functions. Slots 0 through 5 and 8 through 12 are
for interface processors.
Figure 6Cisco 7513, Interface Processor End
Blower module
Cable-management
bracket
Card cage and
processor modules
Air intake vent
Power supplies
Chassis grounding
receptacles
POWER
A
NORMAL
EJECT
SLOT 1
SLOT 0
MASTER
SLAVE
SLAVE/MASTER
CPU HALT
RESET
AUX.
ROUTE SWITCH PROCESSOR 2
CONSOLE
AC
FAN
OUTPUT
OK
OK
FAIL
I
0
AC
FAN
OUTPUT
OK
OK
FAIL
I
0
ENABLE
ENABLE
POWER
B
H5268
VIP-FE-TX/4E Installation and Configuration 9
Page 10
Versatile Interface Processor Functions
VIP Port Adapter Hardware Configuration Overview
The port adapters attach to the VIP motherboard. (See Figure 7.) Each port adapter contains the
physical connections for the VIP interface types to connect to your network.
Figure 7VIP with One FE-TX and One 4E Port Adapter (Product Number VIP-FE-TX/4E[=])
Bus connector
Microcode
Flash U17
DRAM
SIMMs
FE-TX in
port adapter
slot 0
U2
MII
U1
0
LINK
FAST ETHERNET
RJ45
Following are the VIP port adapters by interface type:
• Ethernet 10BASE-T—4E
Port adapter
handles not shown
4E in port
adapter
slot 1
0
1
2
3
LINK
1
3
0
2
ETHERNET-10BT
H4711
• Fast Ethernet 100BASE-TX—FE-TX
• Synchronous serial—4T
• Token Ring—4R
Following are the supported electrical interfaces:
• 4E port adapter—10BASE-T Ethernet, using RJ-45
• FE-TX port adapter—IEEE 802.3u Fast Ethernet 100BASE-TX, using Media Independent
Interface (MII) or RJ-45
• 4T port adapter—synchronous serial (EIA/TIA-232, EIA-TIA-449, EIA-530, V.35, and X.21;
determined by the cable), using DB-60, 60-pin mini-D-sub connectors
• 4R port adapter—IEEE 802.5 Token Ring, using DB-9, 9-pin D-sub connectors
10 VIP-FE-TX/4E Installation and Configuration
Page 11
Note The VIP-FE-TX/4E is a fixed configuration. The FE-TX and 4E port adapters are not
available as individual spare parts. The entire VIP-FE-TX/4E assembly is a FRU. The FE-TX and
4E port adapters have a handle attached, but this handle is not shown to allow a full view of detail
on each port adapter’s faceplate.
Caution To prevent system problems, do not remove port adapters from the VIP motherboard or
attempt to install other port adapters on the VIP motherboard.
VIP Microcode Overview
The VIP microcode(firmware) is an image thatprovides card-specific softwareinstructions. AFlash
memory device in socket U17 of the VIP contains the default microcode boot image. The router
supports downloadable microcode, which enables you to upgrade microcode versions by
downloading new microcode images, storing them in system Flash memory, and instructing the
system to load its image from Flash instead of the default VIP image. (The RP in the Cisco 7000 and
7010 loads software from ROMor Flash memory; the RSP loads software from Flash only.) Youcan
store multiple images for an interface type and, with a configuration command, instruct the system
to load any one of them or the default ROM image. All interfaces of the same type (VIP, and so on)
will load the same microcode image, either from the default ROM image or from a single image
stored in system Flash. Although multiple microcode versions for a specific interface type can be
stored concurrently in Flash, only one image can load at startup. The show controllers cbus
command displays the currently loaded and running microcode version for the SP or SSP (in the
Cisco 7000 series routers), each interface processor, and VIP. The show startup-config EXEC
command shows the current system instructions for loading microcode at startup.
Versatile Interface Processor Functions
Software and interface processor microcode images are carefully optimized and bundled to work
together.Overriding the bundle can result in system incompatibilities. Werecommend that you use
the microcode included in the software bundle. For a complete description of microcode and
downloading procedures, refer to the section “Upgrading VIP Microcode” on page 23.
VIP Installation Prerequisites
This section provides a list of parts and tools you will need to perform the installation, and it also
includes safety and ESD-prevention guidelines to help you avoid injury and damage to the
equipment. This section also providesa detailed description of the OIR function to help you perform
online installation successfully and avoid error message and system restarts. If you are installing a
new VIP, be sure to review the equipment descriptions and distance limitations in the section
“FE-TX Port Adapter Receptacles, Cables, and Pinouts” on page 33 when preparing your site and
planning network connections.
List of Parts and Tools
You need the following tools and parts to install a VIP. If you need additional equipment, contact a
service representative for ordering information.
• Cables appropriate for the port adapter interfaces on your VIP
• Number 1 Phillips and a 3/16-inch, flat-blade screwdriver
• Your own ESD-prevention equipment or the disposable grounding wrist strap included with all
upgrade kits, FRUs, and spares
VIP-FE-TX/4E Installation and Configuration 11
Page 12
Versatile Interface Processor Functions
Safety Guidelines
Following are safety guidelines that you should follow when working with any equipment that
connects to electrical power or telephone wiring.
Electrical Equipment Guidelines
Follow these basic guidelines when working with any electrical equipment:
• Before beginning any procedures requiring access to the chassis interior, locate the emergency
power-off switch for the room in which you are working.
• Disconnect all power and external cables before moving a chassis.
• Do not work alone when potentially hazardous conditions exist.
• Never assume that power has been disconnected from a circuit; always check.
• Do not perform any action that creates a potential hazard to people or makes the equipment
unsafe.
• Carefully examine your work area for possible hazards such as moist floors, ungrounded power
extension cables, and missing safety grounds.
Telephone Wiring Guidelines
Use the following guidelines when working with any equipment that is connected to telephone
wiring or to other network cabling:
• Never install telephone wiring during a lightning storm.
• Never install telephone jacks in wet locations unless the jack is specifically designed for wet
locations.
• Never touch uninsulated telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
• Use caution when installing or modifying telephone lines.
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) damage, which can occur when electronic cards or components are
improperly handled, results in complete or intermittent failures. A processor module comprises a
printed circuit board that is fixed in a metal carrier. Electromagnetic interference (EMI) shielding,
connectors, and a handle are integral components of the carrier.Although the metal carrier helps to
protect the board from ESD, use a preventiveantistatic strap wheneverhandling a processor module.
Following are guidelines for preventing ESD damage:
• Always use an ESD wrist or ankle strap and ensure that it makes good skin contact.
• Connect the equipment end of the strap to a captive installation screw on an installed power
supply.
• When installing a processor module, use the ejector leversto properly seat the bus connectors in
the backplane, thentighten bothcaptiveinstallation screws. (SeeFigure 8.) Thesescrews prevent
accidental removal, provide proper grounding for the system, and help to ensure that the bus
connectors are seated in the backplane.
• When removing a processor module, use the ejector leversto release the busconnectors from the
backplane. Use thehandle to pull the processor module outslowly while keepingyour other hand
underneath the carrier to guide it straight out of the slot.
12 VIP-FE-TX/4E Installation and Configuration
Page 13
• Handle carriers by the handles and carrier edges only; avoid touching the board or connectors.
• Place a removed processor module board-side-up on an antistatic surface or in a static shielding
bag. If you plan to return the component to the factory, immediately place it in a static shielding
bag.
from ESD voltages on the body; ESD voltages on clothing can still cause damage.
• Never attempt to remove the printed circuit board from the metal interface processor carrier.
Caution For safety, periodically check the resistance value of the antistatic strap. The
measurement should be between 1 and 10 megohms.
Online Insertion and Removal—An Overview
The OIR feature allows you to remove and replace a VIP board while the system is operating; you
do not need to notify the software or shut down the system power.
Note The VIP port adapters themselves do not support OIR, nor are they FRUs.
Versatile Interface Processor Functions
This section describes mechanical functions of system components, emphasizes the importance of
following correct procedures to avoid unnecessary board failures, and is for background only;
specific VIP procedures follow in the section “VIP Installation” on page 16.
Each interface processor contains a receptacle with which it connects to the system backplane. Each
backplane connector comprises a set of tiered pins, in three lengths. The pins send specific signals
to the system as they make contact with the card. The system assesses the signals it receives and the
order in which it receives them to determine what event is occurring and what task it needs to
perform, such as reinitializing new interfaces or shutting down removed ones.
For example, when inserting an interface processor, the longest pins make contact with the
backplane first, and the shortest pins make contact last. The system recognizes the signals and the
sequence in which it receives them. The system expects to receive signals from the individual pins
in this logical sequence, and the ejector levers help to ensure that the pins mate in this sequence.
When you remove or insert an interface processor, the backplane pins send signals to notify the
system, which then performs as follows:
1 Rapidly scans the backplane for configuration changes and does not reset any interfaces.
2 Initializes all newly inserted interface processors, noting any removed interfaces and placing
them in the administratively shut down state.
3 Brings all previously configured interfaces on the interface processor back to the state they were
in when they were removed. Any newly inserted interfaces are put in the administratively shut
downstate, as iftheywere present (butunconfigured) at boottime. If asimilar interface processor
type has been reinserted into a slot, then its ports are configured and brought on line up to the
port count of the original interface processor.
VIP-FE-TX/4E Installation and Configuration 13
Page 14
Versatile Interface Processor Functions
The system brings on line only interfaces that match the current configuration and were previously
configured as up; all others require that you configure them with the configure command. OIR
functionality enables you to add, remove, or replace interface processors with the system online,
which provides a method that is seamless to end users on the network, maintains all routing
information, and ensures session preservation.
The function of the ejector levers (see Figure 8) is to align and seat the card connectors in the
backplane. Failure touse theejector leversand insert the interface processorproperly can disrupt the
order in whichthe pinsmake contact with the cardor interfaceprocessor.Followthe VIP installation
and removal instructions carefully, and review the following examples of incorrect insertion
practices and their results:
• Using the handle to force the interface processor all the way into the slot can pop the ejector
levers out of their springs. If you then try to use the ejector levers to seat the interface processor,
the first layer of pins (which are already mated to the card or interface processor) can disconnect
and then remate with the backplane, which the system interprets as a board failure.
• Using the handle to force or slam the interface processor all the way into the slot can damage the
pins on the board connectors if they are not aligned properly with the backplane.
• When using the handle (rather than the ejector levers) to seat the interface processor in the
backplane, you might need to pull the interface processor back out and push it in again to align
it properly. Even if the backplane pins are not damaged, the pins mating with and disconnecting
from the card or interface processor will cause the system to interpret a board failure. Using the
ejector levers ensures that the board connector mates with the backplane in one continuous
movement.
• Using the handle to insert or remove an interface processor, or failing to push the ejector levers
fully against the interface processor, can leave some (not all) of the connector pins mated to the
card or interface processor, a state which will hang the system. Using the ejector levers and
making sure that theyare pushedfully into position ensures thatall three layers of pins are mated
with (or free from) the backplane.
It is also important to use the ejector levers when removing an interface processor to ensure that the
backplane connector pins disconnect from the card or interface processor in the logical sequence
expectedby the system. Any interfaceprocessor that is only partially connected to the backplanecan
hang the bus. Detailed steps for correctly performing OIR are included with the following
procedures for installing and removing the VIP.
14 VIP-FE-TX/4E Installation and Configuration
Page 15
Versatile Interface Processor Functions
Figure 8Ejector Levers and Captive Installation Screws on the VIP (Horizontal Orientation Shown)
Interface processor
card slot
Ejector
lever
Interface processor card
carrier guide (black)
a
Captive
installation
screw
c
b
H1984
Note The VIP is oriented horizontally in the Cisco 7010 and Cisco 7505 and verticallyin the Cisco
7000, Cisco 7507, and Cisco 7513.
VIP-FE-TX/4E Installation and Configuration 15
Page 16
Versatile Interface Processor Functions
VIP Installation
The following sections describe the procedures for removing or installing a VIP in the Cisco 7000
series and Cisco 7500 series routers. The functionality is the same for each router model; therefore,
the term the chassis will be used except where specific model issues arise. The OIR function allows
you to install and remove a VIP without first shutting down the system; however, you must follow
the instructions carefully. Failure to insert the VIP properly can cause system error messages
indicating a board failure. For a complete description of OIR, refer to the section “Online Insertion
and Removal—An Overview” on page 13.
Each unused interface processor slot contains an interface processor filler (which is an interface
processor carrier without an interface board) to keep dust out of the chassis and to maintain proper
air flow through the interface processor compartment. If you are installing a new VIP that is not a
replacement, you must first remove the interface processor filler from an unused slot; proceed to the
next section “Removing an Interface Processor Filler.” If you are replacing a VIP or upgrading the
microcode Flash EPROM on a VIP, proceed to the section “Removing a VIP.”
Note If you suspect that a port adapter has failed, you must replace the entire VIP processor
module. Port adapters are not available as FRUs.
Caution If you use the VIP with a single port adapter, the port adapter must be in slot 0 for the VIP
to function properly. A single port adapter in slot 1 will not be recognized by the system.
Removing an Interface Processor Filler
Select an unused interface processor slot for the new VIP and remove the interface processor filler
as follows:
Step 1 Choose an available slot for the VIP and make a note of it.
Step 1 Use a screwdriver to loosen the captive installation screws on the interface processor filler.
(See Figure 8.)
Step 2 Place your thumbs on both ejector levers and simultaneously pull them both outward to
release the VIP from the backplane connector (in the opposite direction from that shown in
Figure 8c).
Step 3 Grasp the handlewith onehand and pull the filler straight outof theslot, keeping your other
hand under the carrier to guide it. (See Figure 9.) Keepthe carrier parallel to the backplane.
Step 4 Store the interface processor filler for future use.
To help prevent dust andcontaminants fromentering the chassis, do not leave the interface processor
slot open. Immediately proceed to the section “Installing a VIP” on page 18.
Removing a VIP
Remember, the VIP supports OIR; therefore, you need not shut down the interface or the system
power when removing a VIP.If you are replacing a failed VIP, remove the existing board first, then
replace the new VIP in the same slot.
16 VIP-FE-TX/4E Installation and Configuration
Page 17
Versatile Interface Processor Functions
Figure 9 shows proper handling of an interface processor during installation.
Figure 9Handling Processor Modules for Installation and Removal (Horizontal Orientation Shown)
H4714
Captive installation
screws
To remove a VIP, follow these steps:
Step 1 If you are replacing a failed VIP, disconnect all cables from the VIP ports; however, if you
are only moving a VIP to another slot, this step is not necessary.
Step 2 Use a screwdriver to loosen the captive installation screws at both ends of the VIP.
(See Figure 8.)
Caution Always use the ejector levers to remove or install the VIP. Failure to do so can cause
erroneous system error messages indicating a board failure.
Step 3 Place your thumbs on the ejector levers and simultaneously pull both of the ejectors
outward (in the opposite direction from that show in Figure 8c) to release the VIP from the
backplane connector.
Step 4 Use the VIP handle to carefully pull the VIP straight out of the slot, keeping your other
hand under the carrier to guide it. (See Figure 9.) Keep the VIP parallel to the backplane.
Step 5 Place the removed VIP on an antistatic mat or foam pad, or place it in an antistatic bag if
you plan to return it to the factory.
Step 6 If the interface processor slot is to remain empty, install a filler (MAS7K-BLANK) to keep
dust out of the chassis and to maintain proper air flow inside the chassis. Do not leave the
interface processor slot open. Immediately proceed to the section “Installing a VIP.”
VIP-FE-TX/4E Installation and Configuration 17
Page 18
Versatile Interface Processor Functions
Installing a VIP
The VIP slides into the open interface processor slot and connects directly to the backplane. The
interface processors are keyed to guide pins on the backplane, so the VIP can be installed only in an
interface processor slot. Figure 8 shows the functional details ofinserting an interface processor and
usingthe ejector levers.Figure 9 shows proper handling of aninterface processor duringinstallation.
Caution Remove or insert only one interface processor at a time. Allow at least 15 seconds for the
system to complete its discovery and initialization before removing or inserting another interface
processor. Disrupting the sequence before the system has completed verification can cause the
system to interpret hardware failures.
Follow these steps to install a VIP:
Step 1 Ensure that a console terminal is connected to the console port (on the RP or RSP) and that
your console is turned ON.
Step 2 Hold the VIP handle with one hand and place your other hand under the carrier to support
the VIP and guide it into the slot. (See Figure 9.) Avoid touching the card or any connector
pins.
Caution To prevent ESD damage, handle interface processors by the handles and carrier edges
only.
Note The processor modules are oriented horizontally in the Cisco 7010 and Cisco 7505, and
vertically in the Cisco 7000, the Cisco 7507, and the Cisco 7513.
Step 3 Place the back of the VIP in the slot and align the notch on the carrier with the groove in
the slot. (See Figure 8.)
Step 4 Whilekeeping the VIP parallel tothe backplane, carefullyslide it into the slotuntil the back
of the faceplate makes contact with the ejector levers, then stop. (See Figure 8b.)
Caution Always use the ejector levers when installing or removing processor modules. A module
that is partially seated in the backplane will cause the system to hang and subsequently crash, and
shoving or slamming the interface processor into the slot can damage the backplane pins and board.
Step 5 Using your thumbs, simultaneously push both ejector levers inward until the VIP is pushed
entirely into its slot. (See Figure 8c.)
Step 6 To ensure that EMI shielding is properly maintained for the chassis, immediately tighten
both of the captive installation screws.
18 VIP-FE-TX/4E Installation and Configuration
Page 19
Checking the Installation and Verifying VIP Status
You can use the configure command to configure a VIP interface. To use the configure command,
enter the privileged level of the EXEC command interpreter with the enable command. The system
will prompt you for a password if one has been set.
The system prompt for the privileged level ends with a pound sign (#) instead of an angle bracket
(>). At the console terminal, enter the privileged level as follows:
Step 1 At the user-level EXEC prompt, enter the enable command. The EXEC prompts you for a
privileged-level password, as follows:
Router> enable
Password:
Step 2 Enter the password (the password is case sensitive). For security purposes, the password is
not displayed on your console.
Step 3 When you enter the correct password and press Return, the system displays the
privileged-mode system prompt (#) as follows:
Router#
Checking the VIP Installation
After you install the VIP and connect cables (using connection procedures in the respective port
adapter subsections), verify the installation by observing the LED states and the console display.
When the system has reinitialized all interfaces, the enabled LED on the VIP and on all interface
processors should go on. One or the other of the MII and RJ-45 LEDs should be on, depending on
your connection, and the link LED should be on if the VIP is receiving a carrier signal from the
network.
Versatile Interface Processor Functions
The console screen will also display a message as the system discovers each interface during its
reinitialization.
When you remove and replace interface processors, the system provides status messages on the
console screen. The messages are for information only.
Note Fast Ethernet interfaces are used in the following examples.
The following sample display shows the events logged by the system as a Fast Ethernet-equipped
VIP was removed from slot 2; the system then reinitialized the remaining interface processors and
marked as down the Fast Ethernet interfaces on the VIP that wasremoved from slot 2. When the VIP
is reinserted, the system automatically brings up the interfaces that were up when the VIP was
removed.
Router#
%OIR-6-REMCARD: Card removed from slot 2, interfaces disabled
%LINK-5-CHANGED: Interface FastEthernet2/0/0, changed state to administratively down
Router#
%OIR-6-INSCARD: Card inserted in slot 2, interfaces administratively shut down
%LINK-5-CHANGED: Interface FastEthernet2/0/0, changed state to up
VIP-FE-TX/4E Installation and Configuration 19
Page 20
Versatile Interface Processor Functions
Note When a new VIP is inserted or when a VIP is moved to a new slot, the system recognizes the
new interfaces, but leaves them in a shutdown state until you configure them and change their state
to up with the configure command.
The following example display shows the events logged by the system as a new VIP is inserted in
slot 3.
Router#
%OIR-6-INSCARD: Card inserted in slot 3, interfaces administratively shut down
%LINK-5-CHANGED: Interface FastEthernet3/0/0, changed state to administratively down
Verify that the VIP is installed correctly as follows:
Step 1 While the system reinitializes each interface, observe the console display messages and
verify that the system discovers the VIP as follows:
• If you installed a newVIP, the system should recognize all new Fast Ethernet interfaces
but leave them configured as down.
• If you replaced a VIP, the system should recognize each interface and place it in the
same state (up or down) each was in when you removed the VIP.
Step 2 When the reinitialization is complete, verify that the enabled LED on each port adapter
goes on and remains on. If it does, proceed to step 5. If it does not, proceed to the next step.
Step 3 If the enabled LED on a port adapter fails to go on, suspect that the VIP board connector is
not fully seated in the backplane. Loosen the captive installation screws, then firmly push
bothejector levers into placeuntil they areapproximately in the same orientationas the VIP
faceplate. Tighten the captive installation screws. After the system reinitializes the
interfaces, the enabled LED on the port adapter should go on. If it does, proceed to step 5.
If it does not, proceed to step 4.
Step 4 If the enabled LED still fails to go on, remove the VIP and try installing it in another
available interface processor slot.
• If the enabled LED goes on when the VIP is installed in the new slot, suspect a failed
backplane port in the original interface processor slot.
• If the enabled LED still fails to go on, but other LEDs on the VIP go on to indicate
activity, proceed to step 5 to resume the installation checkout and suspect that the
enabled LED on the port adapter has failed.
• If no LEDs on the VIP go on, suspect that the VIP is faulty.
• If the enabled LED still does not go on, do not proceed with the installation. Contact a
service representative to report the problem and obtain further instructions.
Step 5 If the VIP is new and not a replacement, you have to configure the new interfaces. Proceed
to the appropriate configuration section for your port adapter. (This does not have to be
done immediately, but new interfaces will not be available until you configure them.)
Step 6 If the VIP is a replacement, use the show interfaces type slot/port adapter/port or show
controllers cbus command to verify the status of the interfaces. (Refer to the section
“Verifying VIP Status Using show Commands” on page 21.)
If you replaced a VIP with a new VIP with a greater number of ports (for example, if you
replaced a one-port VIP with a two-port VIP), the system will recognize the first interface,
but will not recognize the additional interface. The new interface will remain in the
shutdown state until you configure it.
20 VIP-FE-TX/4E Installation and Configuration
Page 21
Step 7 When the interfaces are up, check the activity of each interface by observing the status
LEDs, which are described in the appropriate LED section for your port adapter type.
Step 8 In general, if an interface’s LED fails to go on and a cable is connected to the port, check
the cable connection and make certain it is properly seated in the connector.
If an error message is displayed on the console terminal, refer to the System Error Messages
publication for error message definitions. If you experience other problems that you are unable to
solve, contact a service representative for assistance.
This completes the VIP installation. If you installed a newVIP or if you installed a replacement VIP
with an additional port, you must now configure the new interface as described in the following
section.
Verifying VIP Status Using show Commands
The followingprocedure describes how to use the show commands to verify that the new interfaces
are configured correctly:
Step 1 Use the show version or show hardware commands to display the system hardware
configuration. Ensure that the list includes the new Fast Ethernet interfaces.
Step 2 Display all of the current interface processors and their interfaces with the show
controllers cbus command. Verify that the new VIP appears in the correct slot.
Versatile Interface Processor Functions
Step 3 Specify one of the new VIP interfaces with the show interfaces type slot/port adapter/port
command and verify that the first line of the display specifies the interface with the correct
slot number. Also verify that the interface and line protocol are in the correct state: up or
down.
Step 4 Display the protocols configured for the entire system and specific interfaces with the
command show protocols. If necessary,return tothe Configurationmode to add or remove
protocol routing on the system or specific interfaces.
Step 5 Display the entire system configuration filewith the show configuration command. Verify
that the configuration is accurate for the system and each interface.
If the interface is down and you configured it as up, or if the displays indicate that the hardware is
not functioning properly,ensure that the network interface is properly connected and terminated. If
you still have problems bringing the interface up, contact a service representative for assistance.
VIP-FE-TX/4E Installation and Configuration 21
Page 22
Versatile Interface Processor Functions
The show controllers cbus command displays the internal status of each interface processor,
including the slot location, the card hardware version,and the currently-running microcode version.
It also lists each interface (port) on each interface processor including the logical interface number,
interface type, physical (slot/port adapter/port) address, and hardware (station address) of each
interface. The following example shows a VIP, with Fast Ethernet interfaces, installed in interface
processor slot 3:
Router# show controller cbus
(display text omitted)
slot3: VIP, hw 2.1, sw 200.09, ccb 5800FF70, cmdq 480000A0, vps 8192
software loaded from system
FLASH ROM version 255.255, VPLD version 20.0
FastEthernet3/0/0, addr 0000.0ca5.2380 (bia 0000.0ca5.2380)
gfreeq 48000140, lfreeq 48000238 (1536 bytes), throttled 0
rxlo 4, rxhi 123, rxcurr 16, maxrxcurr 16
txq 48000240, txacc 480000EA (value 77), txlimit 77
(display text omitted)
The show startup-config command displays the contents of the system configuration file stored in
NVRAM.This fileshould reflect allnew configuration changesyou made and wrote tomemory with
the show running-config command. (A Fast Ethernet interface is used in this example.)
Router# show startup-config
Using 1652 out of 130048 bytes
version 11.1(1)
!
hostname Router
!
enable-password hello
!
microcode VIP flash VIP11-0
microcode reload
!
(display text omitted)
!
interface FastEthernet 3/0/0
ip address 1.1.1.1 255.255.255.248
ip route-cache cbus
!
(display text omitted)
The show protocolscommand displays theglobal (system-wide) and interface-specific statusof any
configured Level 3 protocol.
Router# show protocols
Global values:
Internet Protocol routing is enabled
FastEthernet3/1/0 is up, line protocol is up
22 VIP-FE-TX/4E Installation and Configuration
Page 23
Upgrading VIP Microcode
The Cisco 7000 series and the Cisco 7500 series support downloadable microcode, which enables
you to upgrade microcode versions without having to physically replace the microcode Flash
memory device on the board. You can downloadnewmicrocode versions andstore multiple versions
in Flash memory, and you can boot from them just as you can with the system software images.
System software upgrades may also contain upgraded microcode images, which will load
automatically when the new software image is loaded (unless the configuration states otherwise).
Note Software and interface processor microcode images are carefully optimized and bundled to
worktogether.Overridingthe bundlecan result insystem incompatibilities.Werecommendthat you
use the microcode included in the software bundle.
You can downloadmicrocode to Flash memory by copying the TFTP image of a microcode version
to Flash memory. When the microcode image is stored in Flash memory you can use the
microcode reload command to manually load the new microcode file, and the configure command
to instruct the system to load the new image automatically at each system boot.
To compare the size of the microcode image and the amount of Flash memory available, you must
know the size of the new microcode image. The image size is specified in the README file that is
included on the floppy disk with the new image.
Versatile Interface Processor Functions
Note Note the size of the new image before proceeding to ensure that you have sufficient available
Flash memory for the new image.
Caution Before you copy a file to system Flash memory, be sure there is ample space available in
Flash memory. Compare the size of the file you want to copy to the amount of available Flash
memory shown. If the space available is less than the space required by the file you want to copy,
the copy process will continue, but the entire file will not be copied into Flash memory.
VIP-FE-TX/4E Installation and Configuration 23
Page 24
Versatile Interface Processor Functions
Follow these steps to download (copy) a microcode version from a TFTP server to Flash memory.
Step 1 To display the total amount of Flash memory present, its location, any files that currently
exist in Flash memory and their size, and the amount of Flash memory remaining, use the
show flash command. Following is an example of the output that is displayed:
Router# show flash
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. FFFFFFFF B4A18E0B 3F6494 30 4023316 Jun 26 1994 19:44:29 image/file/1
2 .. FFFFFFFF 8075AA5D 4118B4 23 111518 Jun 29 1994 11:05:57 image/file/2
12044568 bytes available (8533736 bytes used)
Step 2 Compare the amount of available Flash memory (last line in the preceding example) to the
size of the new microcode image on the floppy disk. If you attempt to copy in a new image,
and the size of the new image exceeds the available space in Flash, only part of the new
image will be copied, and the following error message will be displayed:
buffer overflow - xxxx/xxxx
where xxxx/xxxx is the number of bytes read in/number of bytes available.
Step 3 After you verify that there is sufficient space availablein Flash memory for the newimage,
use the command copy tftp:filename [ flash | slot0 | slot1 ]:filename to copy an image to
Flash memory. (tftp:filename is the file’s source, and [ flash | slot0 | slot1 ]:filename is the
destination in onboard Flash memory or on either of the Flash memory cards.)
An example of the copy tftp:filename command follows:
Router# copy tftp:vip11-1 slot0:vip11-1
20575008 bytes available on device slot0, proceed? [confirm]
Address or name of remote host [1.1.1.1]?
Loading new.image from 1.1.1.1 (via Ethernet1/0): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!![OK - 7799951/15599616 bytes]
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
CCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCC
Router#
Step 4 Use the show flash command to verify that the microcode has been copied to Flash. The
output should display the filename of the image you copied to Flash (vip11-1 in the
following example):
Router# show flash
-#- ED --type-- --crc--- -seek-- nlen -length- -----date/time------ name
1 .. FFFFFFFF B4A18E0B 3F6494 30 4023316 Jun 26 1994 19:44:29 image/file/1
2 .. FFFFFFFF 8075AA5D 4118B4 23 111518 Jun 29 1994 11:05:57 image/file/2
3 .. FFFFFFFF EEA1FEEB 8436E8 22 4398516 Oct 10 1995 19:35:25 vip11-1
7646052 bytes available (16179788 bytes used)
24 VIP-FE-TX/4E Installation and Configuration
Page 25
Versatile Interface Processor Functions
Step 5 To ensure that the new microcode is used when you reboot the system, add the appropriate
commands to the configuration file. To modify the configuration file, enter the configure
terminal command, as follows:
Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#
Step 6 Specify that you are changing the microcode for the VIP (microcode vip), and that it will
load from Flash memory (flash). Then add the filename of the new microcode image to be
loaded from Flash:
Router(config)# microcode vip flash slot0:vip11-1
Step 7 To save the configuration file, press Ctrl-Z.
Step 8 Copy the new configuration to nonvolatile random-access memory (NVRAM):
Router# copy running-config startup-config
The microcode reload command is automatically added to your running configuration.
The new VIP microcode image will load automatically the next time the system boots or
reinitializes.
Step 9 To loadthe new microcodeimmediately,youcan issuethe microcode reloadconfiguration
command (you must be in Configuration mode to enter this command):
Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)# microcode reload
Immediately after you enter the microcode reloadcommand andpress Return,the system
reloads all microcode. Configuration mode remains enabled; after the reload is complete,
press Ctrl-Z to exit from Configuration mode and return to the system prompt.
Step 10 To verify that the VIP is using the correct microcode, issue the show startup-config or
show controllers cbus command, which indicates the currently loaded and running
microcode version for each interface processor and the SP or SSP in the Cisco 7000 series
routers.
Router# show controllers cbus
This completes the procedure for downloading microcode to Flash memory.
VIP-FE-TX/4E Installation and Configuration 25
Page 26
Versatile Interface Processor Functions
Upgrading and Replacing DRAM SIMMs
VIPs are shipped with 8 MB of DRAMas the default memory configuration. Depending on memory
requirements, you might need to upgrade the amount of DRAM by replacing the DRAM SIMMs on
the VIP. You also might need to replace a single SIMM in the case of a diagnosed DRAM SIMM
failure.
Note DRAM SIMMs should be upgraded or replaced in the field by a Cisco-certified maintenance
provider. Both DRAM SIMMs are replaced for all upgrades.
Caution SIMMs are sensitive components that are susceptible to ESD damage. Handle SIMMs by
the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the
connector edge of the SIMM). (See Figure 10.)
Figure 10 Handling a DRAM SIMM—Example Only
H2326
26 VIP-FE-TX/4E Installation and Configuration
Page 27
Versatile Interface Processor Functions
Following is the procedure for replacing or upgrading DRAM SIMMs.
Step 1 Attach an ESD-preventive wrist strap between you and an unpainted chassis or VIP surface.
Step 2 Disconnect all cables from the VIP and remove it from the chassis using the procedure in
the section “Removing a VIP” on page 16.
Step 3 Place the VIP on a flat surface (preferably an antistatic mat or foam), and turn it so the face
plate is away from you and the connector edge is toward you. (approximately opposite of
the orientation shown in Figure 11).
Step 4 Locate the DRAM SIMMs in U1 and U2. (See Figure 11.)
Figure 11 Orientation of DRAM SIMMs (U1 and U2) on VIP Motherboard (VIP-1FE-TX/4E Shown)
Bus connector
Microcode
Flash U17
DRAM
SIMMs
FE-TX in
port adapter
slot 0
U2
MII
U1
0
LINK
FAST ETHERNET
RJ45
Port adapter
handles not shown
4E in port
adapter
slot 1
0
1
2
3
LINK
1
3
0
2
ETHERNET-10BT
H4711
VIP-FE-TX/4E Installation and Configuration 27
Page 28
Versatile Interface Processor Functions
Step 5 Remove a SIMM by pulling outward on the connectors to unlatch it, as shown in the
enlargement in Figure 12. Be careful not to break the holders on the SIMM connector.
Figure 12 Removing and Replacing DRAM SIMMs
Faceplate edge of
the system card
Pull the tabs away with
your thumbs, bracing your
forefingers against the
posts. Raise the SIMM
to a vertical position.
Polarization notch
DRAM SIMM
Step 6
Using the SIMM orientation shown in Figure 12, position the new SIMM so that the
polarization notch is located at the right end of the SIMM socket.
Step 7 Insert the new SIMM by sliding the end with the metal fingers into the SIMM connector
socket at approximately a 45-degree angle to the system card. Gently rock the SIMM back
into place until the latch on either side snaps into place. (See Figure 12.)
Caution Do not use excessiveforce, or the connector could break. Toprevent damage, do not push
on the center of the SIMMs. Handle each SIMM with care.
Step 8 As required, repeat Steps 5 through 7 for the second SIMM.
Step 9 Reinstall the VIP in the chassis using the procedure in the section “Installing a VIP” on
page 18.
H2017
If error messages relating to memory are displayed once power to the chassis is turned back on, or
the VIP card is installed in a chassis that is already on, repeat Steps 1 through 8, taking care to firmly
reseat each SIMM in its socket.
This completes the procedure for upgrading or replacing DRAM SIMMs on your VIP.
28 VIP-FE-TX/4E Installation and Configuration
Page 29
VIP Port Adapter Functions
The following sections discuss the port adapters used with the VIP:
• FE-TX Port Adapter
• 4E Port Adapter, page 44
FE-TX Port Adapter
The following sections discuss the FE-TX port adapter, which is shown in Figure 13.
• Fast Ethernet Overview
• FE-TX Port Adapter Description and Fast Ethernet Specifications, page 31
• FE-TX Port Adapter LEDs, page 32
• FE-TX Port Adapter Receptacles, Cables, and Pinouts, page 33
• Attaching FE-TX Port Adapter Interface Cables, page 36
• Configuring the FE-TX Interface, page 37
VIP Port Adapter Functions
Figure 13 FE-TX Port Adapter, Faceplate View
Fast Ethernet Overview
The VIP configured with two FE-TX port adapters provides up to two 100-Mbps, 100BASE-T, Fast
Ethernet interfaces. Each 100BASE-T port on the FE-TX port adapter has an RJ-45 connector to
attach to Category 5 unshielded twisted-pair (UTP) for 100BASE-TX, and a MII connector that
permits connection through external transceivers to multimode fiber for 100BASE-FX, or to
Category 3, 4, and 5 UTP or shielded twisted-pair (STP) for 100BASE-T4 physical media. Both
full-duplex and half-duplex operation are supported.The term Ethernet is commonly used for all
carrier sense multiple access/collision detection (CSMA/CD), local-area networks (LANs) that
generally conform to Ethernet specifications, including IEEE 802.3u.
Note 100BASE-TX is intended for Environment A and 100BASE-FX is intended for
Environment B.
ENABLED
FAST ETHERNET
MII
LINK
RJ45
0
H4495
IEEE 802.3u is well suited to applications where a local communication medium must carry
sporadic,occasionally heavy trafficathigh peak datarates. Stations ona CSMA/CD LAN can access
the network at any time. Before sending data, the station listens to the network to see if it is already
in use. If it is, the station waits until the network is not in use, then transmits; this is half-duplex
operation. A collision occurs when two stations listen for network traffic, hear none, and transmit
very close to simultaneously.When this happens, both transmissions are damaged, and the stations
must retransmit.
VIP-FE-TX/4E Installation and Configuration 29
Page 30
VIP Port Adapter Functions
The stations detect the collision and use backoff algorithms to determine when they should
retransmit. Both Ethernetand IEEE802.3u are broadcast networks, whichmeans that all stations see
all transmissions. Each station must examinereceivedframes to determine whether it is the intended
destination and, if it is, pass the frame to a higher protocol layer for processing.
Each physical layer protocol has a name that summarizes it characteristics in the format
speed/signaling method/segment length where speed is the LAN speed in megabits per second
(Mbps), signaling methodis the signaling method used (either basebandor broadband),and segment
length is typically the maximum length between stations in hundreds of meters. Therefore,
100BASE-Tspecifies a 100-Mbps, baseband LAN with maximum network segments of 100 meters
(or 400 meters for 100BASE-FX).
IEEE 802.3u specifies the following different physical layers for 100BASE-T:
• 100BASE-TX—100BASE-T, half and full duplex over Category 5 unshielded twisted-pair
(UTP), Electronics Industry Association/Telecommunications Industry Association
[EIA/TIA]–568-compliant cable
• 100BASE-FX—100BASE-T, half and full duplex over optical fiber
• 100BASE-T4—100BASE-T, half and full duplex over Category 3, 4, or 5 UTP or shielded
twisted-pair (STP) cabling with four pairs; also called 4T+ or T2, which is 2-pair UTP over
Category 3 cable.
30 VIP-FE-TX/4E Installation and Configuration
Page 31
FE-TX Port Adapter Description and Fast Ethernet Specifications
The FE-TX port adapter is available in the following VIP configurations: FE-TX/blank, FE-TX/4E,
or FE-TX/FE-TX. (For a description of the 4E port adapter, refer to the section “4E Port Adapter”
on page 44.) Figure 14 shows VIP-FE-TX/4E. The FE-TX and 4E port adapters have a handle
attached, but this handle is not shown to allow a full view of detail on each port adapter’s faceplate.
Figure 14 VIP with One FE-TX and One 4E Port Adapter Installed (Horizontal Orientation Shown)
Bus connector
VIP Port Adapter Functions
Microcode
Flash U17
U2
DRAM
SIMMs
U1
FE-TX in
port adapter
slot 0
Caution
FAST ETHERNET
0
MII
LINK
RJ45
To prevent system problems, do not remove port adapters from the VIP motherboard, or
0
attempt to install other port adapters on the VIP motherboard.
Port adapter
handles not shown
4E in port
adapter
slot 1
1
2
3
LINK
1
3
0
2
ETHERNET-10BT
H4711
VIP-FE-TX/4E Installation and Configuration 31
Page 32
VIP Port Adapter Functions
Table 1 lists the cabling specifications for 100-Mbps Fast Ethernet transmission over UTP and STP
cables. Table 2 summarizes IEEE 802.3u 100BASE-T physical characteristics.
Table 1Specifications and Connection Limits for 100-Mbps 100BASE-T Transmission
ParameterRJ-45MII
1
Cable specificationCategory 5
Maximum cable length–0.5 m (1.64 ft.) (MII-to-MII cable
Maximum segment length100 m (328 ft.) for 100BASE-TX1 m (3.28 ft.)5 or 400 m (1,312 ft.) for 100BASE-FX
Maximum network length200 m (656 ft)5.(with 1 repeater)–
1. EIA/TIA-568 or EIA-TIA-568 TSB-36 compliant.
2. Cisco Systems does not supply Category 5 UTP RJ-45 or 150-ohm STP MII cables. Both are available commercially.
3. AWG = American Wire Gauge. This gauge is specified by the EIA/TIA-568 standard.
4. This is the cable between the MII port on the FE-TX port adapter and the appropriate transceiver.
5. This length is specifically between any two stations on a repeated segment.
Table 2IEEE 802.3u Physical Characteristics
UTP2, 22 to 24 AWG
3
Category 3, 4, or 5, 150-ohm UTP or STP, or multimode optical fiber
4
)
Parameter100BASE-T
Data rate (Mbps)100
Signaling methodBaseband
Maximum segment length (meters) 100 m between DTE
MediaRJ-45: Category 5 UTP
TopologyStar/Hub
1. DTE = data terminal equipment.
FE-TX Port Adapter LEDs
The FE-TX port adapter contains theenabled LED, standard on all port adapters, and a bank of three
status LEDs for the ports. After system initialization, the enabled LED goes on to indicate that the
FE-TX port adapter has been enabled for operation. (The LEDs are shown in Figure 15.) The
following conditions must be met before the enabled LED goes on:
• The FE-TX interface is correctly connected to the backplane and receiving power.
• The FE-TX-equipped VIP contains a valid microcode version that has been downloaded
successfully.
• The bus recognizes the FE-TX-equipped VIP.
If any of these conditions is not met, or if the initialization fails for other reasons, the enabled LED
does not go on.
1
and repeaters
MII: Category 3, 4, or 5, 150-ohm UTP or STP, with appropriate transceiver
32 VIP-FE-TX/4E Installation and Configuration
Page 33
VIP Port Adapter Functions
The bank of three status LEDs indicates the following:
• MII—On when the MII port is selected as the active port by the controller.
• Link—When the RJ-45 port is active, this LED is on when the FE-TX port adapter is receiving
a carrier signal from the network. When the MII port is active, this LED is an indication of
network activity, and it flickers on and off proportionally to this activity.
• RJ-45—On when the RJ-45 port is selected as the active port by the controller.
Either the MII LED or the RJ-45 LED should be on at any one time; never both.
Figure 15 LEDs on the FE-TX Port Adapter (Horizontal Orientation Shown)
H4710
Note The VIP isoriented horizontally in the Cisco 7010 andCisco 7505,and vertically inthe Cisco
7000, the Cisco 7507, and the Cisco 7513.
FE-TX Port Adapter Receptacles, Cables, and Pinouts
The two interface receptacles on the FE-TX port adapter are a single MII, 40-pin, D-shell type, and
a single RJ-45.You canuse eitherone or the other.Only onereceptacle can be used atone time.Each
connection supports IEEE 802.3u interfaces compliant with the 100BASE-X and 100BASE-T
standards. The RJ-45 connection does not require an external transceiver. The MII connection
requires an external physical sublayer (PHY) and an external transceiver.
Figure 16 shows the RJ-45 connectors. Table 3 lists the pinouts and signals for the FE-TX RJ-45
connectors.
Figure 16 FE-TX RJ-45 Connections, Plug and Receptacle
8 7 6 5 4 3 2 1
-
H2936
Warning
The ports labeled “Ethernet,” “10BaseT,” “Token Ring,” “Console,” and “AUX” are
safety extra-low voltage (SELV) circuits. SELV circuits should only be connected to other SELV
circuits. Because the BRI circuits are treated like telephone-network voltage, avoid connecting the
SELV circuit to the telephone network voltage (TNV) circuits. (For translated versions of this
warning, refer to the section “SELV Circuit Warning Translations” on page 57.)
1Receive Data + (RxD+)
2RxD–
3Transmit Data + (TxD+)
6TxD–
Note Referring to the RJ-45 pinout in Table 3, proper common-mode line terminations should be
used for the unused Category 5, UTP cable pairs 4/5 and 7/8. Common-mode termination reduces
the contributions to electromagnetic interference (EMI) and susceptibility to common-mode
sources. Wire pairs 4/5 and 7/8 are actively terminated in the RJ-45, 100BASE-TX port circuitry in
the FE-TX port adapter.
Depending on your RJ-45 interface cabling requirements, use the pinouts in Figure 17 and
Figure 18.
Figure 17 Straight-Through Cable Pinout, FE-TX RJ-45 Connection to a Hub or Repeater
EIP
TxD+
TxD–
RxD+
RxD–
Hub or repeater
5 RxD+
6 RxD–
3 TxD+
4 TxD–
H3137
Figure 18 Crossover Cable Pinout, FE-TX RJ-45 Connections between Hubs and Repeaters
b or LAN switch
3 TxD+
6 TxD–
1 RxD+
2 RxD–
Hub or LAN switch
3 TxD+
6 TxD–
1 RxD+
2 RxD–
H3138
Depending on the type of media you use between the MII connection on the port adapter and your
switch or hub, the network side of your 100BASE-T transceiver should be appropriately equipped:
with ST-type connectors (for optical fiber), BNC connectors, and so forth. Figure 19 shows the pin
orientation of the female MII connector on the port adapter. The port adapters are field-replacable
units (FRUs).
34 VIP-FE-TX/4E Installation and Configuration
Page 35
VIP Port Adapter Functions
The MII receptacle uses 2-56 screw-type locks, called jackscrews (shown in Figure 19), to secure
the cable or transceiver to the MII port. MII cables and transceivers have knurled thumbscrews
(screws you can tighten with your fingers) that you fasten to the jackscrews on the FE-TX port
adapter’sMII connector. Use the jackscrews to provide strain relief for your MII cable. (The RJ-45
modular plug has strain relief functionality incorporated into the design of its standard plastic
connector.) Figure 19 shows the MII female connector.
Figure 19 FE-TX MII Connection, Receptacle
Pin 21
H2943
ckscrewPin 1
Table 4 lists the MII connector pinout and signals. MII cables are available commercially.
Table 4FE-TX MII Connector Pinout
1
Pin
InOutIn/OutDescription
14–17–Yes–Transmit Data (TxD)
12Yes––Transmit Clock (Tx_CLK)
2
11–Yes–Transmit Error (Tx_ER)
13–Yes–Transmit Enable (Tx_EN)
3–Yes–MII Data Clock (MDC)
4–7Yes––Receive Data (RxD)
9Yes––Receive Clock (Rx_CLK)
10Yes––Receive Error (Rx_ER)
8Yes––Receive Data Valid (Rx_DV)
18Yes––Collision (COL)
19Yes––Carrier Sense (CRS)
2––YesMII Data Input/Output (MDIO)
22–39–––Common (ground)
1, 20, 21, 40–––+5.0 volts (V)
1. Any pins not indicated are not used.
2. Tx_CLK and Rx_CLK are generated by the external transceiver.
VIP-FE-TX/4E Installation and Configuration 35
Page 36
VIP Port Adapter Functions
Attaching FE-TX Port Adapter Interface Cables
On a single 100BASE-T port adapter, you can use either the RJ-45 connection or the MII
connection. If you have two FE-TX, 100BASE-T port adapters on your VIP, you can use the RJ-45
connection on one and the MII connection on the other.
Note RJ-45 and MII cables are not available from Cisco Systems; they are available from outside
commercial cable vendors.
Connect RJ-45 and MII cables as follows:
Step 1 If you have RJ-45 connections, attach the Category 5 UTP cable directly to the RJ-45 port
on the FE-TX port adapter. (See Figure 20.)
If you haveMII connections, attach anMII cable directly to the MII port on the FE-TX port
adapter or attach a 100BASE-Ttransceiver,with the media appropriate to yourapplication,
to the MII port on the FE-TX port adapter. (See Figure 20.)
The FE-TX port adapter is an end station device and not a repeater. You must connect the
FE-TX port adapter to a repeater or hub.
Note The FE-TX and 4E port adaptershave a handle attached, but this handle is not shown to allow
a full view of detail on each port adapter’s faceplate.
Figure 20 Connecting FE-TX MII and RJ-45 Cables (Horizontal Orientation—Shown without Handles)
0
To transceiver,
repeater, or DTE
FAST ETHERNET
or
To repeater
RJ-45 cableMII cable
or DTE
0
1
2
3
To transceiver,
repeater, or DTE
LINK
1
3
0
2
ETHERNET-10BT
H6088
RJ-45 cable (up to four)
36 VIP-FE-TX/4E Installation and Configuration
Page 37
VIP Port Adapter Functions
Step 2 Attach the ferrite bead to the RJ-45 cable (at either end), as shown in Figure 21.
Caution The ferrite bead prevents electromagnetic interference (EMI) from affecting the
FE-TX-equipped system and is a required component for proper system operation.
Figure 21 Attaching the Ferrite Bead around the RJ-45 Cable
Caution To prevent problems on your FE-TX port adapter and network, do not simultaneously
connect RJ-45 and MII cables to one 100BASE-T port adapter. On a single 100BASE-T port
adapter,only one network connection can be used at one time.Only connect cables that comply with
EIA/TIA-568 standards. (Refer to Table 1 and Table 2 on page 32 for cable recommendations and
specifications.)
Step 3 Attach the networkend ofyour RJ-45 or MII cable to your 100BASE-T transceiver,switch,
hub, repeater, DTE, or other external 100BASE-T equipment.
This completes the FE-TX installation. Proceed to the section “Checking the VIP Installation.”
Configuring the FE-TX Interface
If you installed a new FE-TX interface or if you want to change the configuration of an existing
interface, you must enter Configuration mode, using the configuration command. If you replaced
an interface that was previously configured, the system will recognize the new interface and bring it
up in its existing configuration.
After you verify that the new FE-TX is installed correctly (the enabled LED goes on), use the
privileged-level configure command to configure the new interfaces. Be prepared with the
information you will need, such as the following:
Ferrite beadRJ-45 cable
with ferrite bead
H4202
• Protocols you plan to route on each new interface.
• Internet protocol (IP) addresses if you plan to configure the interfaces for IP routing.
• Whether the new interfaces will use bridging.
Note For a summary of the configuration options available and instructions for configuring the
FE-TX interfaces on the VIP, refer to the publications listed in the section “If You Need More
Information” on page 2.
VIP-FE-TX/4E Installation and Configuration 37
Page 38
VIP Port Adapter Functions
Note The configurecommand requires privileged-level access to the EXEC command interpreter,
which usually requires a password. Contact your system administrator, if necessary, to obtain
EXEC-level access.
Selecting Chassis Slot, Port Adapter, and Fast Ethernet Interface Port Numbers
The following section describeshow to identifychassis slot, port adapter, and FastEthernet interface
port numbers.
Note Although the processor slots in the seven-slot Cisco 7000 and 13-slot Cisco 7513 are
verticallyoriented and those in the five-slotCisco 7010 andCisco 7505 are horizontally oriented, all
models use the same method for slot and port numbering. (Refer to Figure 2, Figure 3, Figure 4,
Figure 5, or Figure 6 for interface processor slot orientation in your chassis.)
In the router, physical port addresses specify the actual physical location of each interface port on
the router interface processor end. (See Figure 22.) This address is composed of a three-part number
in the format chassis slot number/port adapter number/interface port number.
The first number identifies the chassis slot in which the VIP is installed (as shown in the example
system in Figure 22). The secondnumber identifies the physical port adapter numberon the VIP, and
is either 0 or 1. The interface ports on each FE-TX port adapter are always numbered as interface 0.
Interface ports on the VIP maintain the same address regardless of whether other interface
processors are installed or removed. However, when you move a VIP to a different slot, the first
number in the address changes to reflect the new slot number.
38 VIP-FE-TX/4E Installation and Configuration
Page 39
VIP Port Adapter Functions
Figure 22 shows some of the slot port adapter and interface ports of a sample Cisco 7505 system.
For example, on a FE-TX/FE-TX VIP in slot 3, the address of the first Fast Ethernet port adapter is
3/0/0 (chassis slot 3, port adapter slot 0, and interface port 0), and the address of the second Fast
Ethernet port adapter is 3/1/0 (chassis slot 3, port adapter slot 1, and interface port 0).
The individual port adapter numbers are always 0 and 1. The individual interface port numbers
always begin with 0. For example, the FE-TX port adapters in the first and second port adapter slots
in chassis slot 3 would havethefollowing addresses: 3/0/0 and 3/1/0.The numberof additional ports
depends on the number of ports on a port adapter.
Note If you remove the VIP from slot 3 and install it in slot 2, the addresses of those same ports
become 2/0/0 and 2/1/0.
Figure 22 Fast Ethernet Interface Port Number Example (Cisco 7505 Shown)
3/0/0 (FE-TX port adapter)
ROUTE SWITCH PROCESSOR
AUX.
CONSOLE
ETHERNET 10BT
LINK
3
2
1
3
2
0
Slot 3
Slot 2
Slot 1
Interface
processor
slots
NORMAL
ENABLE
EJECT
SLOT 1
SLOT 0
CPU HALT
RESET
1
0
Slot 0
H5922
Note: The MII and RJ-45 interface ports on the first port adapter are both
numbered as interface port 0. Only one of them can be used on each port adapter,
at one time.
You can identify interface ports by physically checking the slot/port adapter/interface port location
on the back of the router or by using software commands to display information about a specific
interface or all interfaces in the router.
To display information about a specific interface, use the show interfaces command with the
interface type and port address in the format show interfaces [type slot/port adapter/port].
Following is an example of how the show interfaces command displays status information
(including the physical slot and port address) for the interface you specify. In this example, most of
the status information for each interface is omitted, and a Fast Ethernet interface in slot 3 is used.
Router# sh int fa 3/0/0
FastEthernet3/0/0 is administratively down, line protocol is down
Hardware is cyBus FastEthernet Interface, address is 0000.0ca5.2380 (bia 0000)
MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec), hdx, 100BaseTX
(display text omitted)
VIP-FE-TX/4E Installation and Configuration 39
Page 40
VIP Port Adapter Functions
Fast Ethernet interface port adapters are numbered from 0 and 1 because VIPs support up to two
100BASE-T ports. The MII and RJ-45 ports on a port adapter each have the same port number
because only one of them can be used at one time.
Refer to Table 5, Table 6, Table 7, Table 8, and Table 9 for the FE-TX port numbers associated with
the interface processor slots in your chassis. If you install a VIP with two FE-TX port adapters, you
can configure both ports; if you install a VIP with one FE-TX port adapter, you need configure only
that port.
Note Table 5, Table 6, Table 7, Table 8, and Table 9 indicate FE-TX interface port numbers based
on the slots in which they can be installed; they do not represent examples of maximum FE-TX
configurations.
Table 5FE-TX Slot, Port Adapter, and Port Numbers in a Cisco 7000
Slot 0/
1. The FE-TX port adapters are installed in port adapter slot 0 on VIP-FE-TX(=) and VIP-FE-TX/4E(=), and in port adapter slots 1 and 2 on the
VIP-FE-TX/FE-TX (=).
Withthe show interfaces type slot/port adapter/port command, use arguments such as the interface
type (fastethernet, and so forth) and the port number (slot/port) to display information about a
specific interface only.The followingexampleof the showinterfaces fastethernet commandshows
information specific to the Fast Ethernet interface on the first FE-TX port adapter in slot 3:
Router# show interfaces fastethernet 3/0/0
FastEthernet3/0/0 is administratively down, line protocol is down
Hardware is cyBus FastEthernet Interface, address is 0000.0ca5.2380 (bia 0000)
MTU 1500 bytes, BW 100000 Kbit, DLY 100 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec), hdx, 100BaseTX
ARP type: ARPA, ARP Timeout 4:00:00
Last input 3:08:43, output 3:08:42, output hang never
Last clearing of "show interface" counters 2:58:36
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
0 watchdog, 0 multicast
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets, 0 restarts
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
Configuring the FE-TX Port Adapters—Descriptions and Examples
Followingare descriptions and examples of the commands for configuring the VIP FE-TX interface
3/0/0 (slot 3, port adapter 0, Fast Ethernet interface port 0). If a second Fast Ethernet interface is
present, configure it the same way except that the port adapter number is port adapter 1 (3/1/0).
Descriptions are limited to fields that are relevant for establishing and verifying the configuration.
After configuring the new FE-TX interface, use show commands to display the status of the new
interface or all interfaces, or to verify changes you have made.
Depending on the requirementsfor your system configuration andthe protocols you plan toroute on
the interface, you might also need to enter other configuration subcommands. For complete
descriptionsof configuration subcommands and theconfiguration options availableforFastEthernet
interfaces, refer to the publications listed in the section “If You Need More Information” on page 2.
VIP-FE-TX/4E Installation and Configuration 41
Page 42
VIP Port Adapter Functions
FE-TX half-duplex operation is the default. To change to full-duplex operation, use the following
series of commands:
Router# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)#
Using the showinterfaces fastethernetcommand, youcan seethat the3/0/0 FastEthernet interface
is now configured for full-duplex operation, as follows:
Router# sh int fa 3/0/0
FastEthernet 3/0/0 is administratively up, line protocol is up
(display text omitted)
Encapsulation ARPA, loopback not set, keepalive not set, fdx, 100BaseTX
To return the interface to half-duplex operation, use the no full-duplex configuration command, as
follows:
Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)# int fa 3/0/0
Router(config-if)# no full-duplex
Router(config-if)# ^Z
Router#
Using the showinterfaces fastethernetcommand, youcan seethat the3/0/0 FastEthernet interface
is now configured for half-duplex operation, as follows:
Router# sh int fa 3/0/0
FastEthernet3/0/0 is administratively up, line protocol is up
(display text omitted)
Encapsulation ARPA, loopback not set, keepalive not set, hdx, 100BaseTX
(display text omitted)
The RJ-45 connection is the default. To change to an MII connection and then verify it, use the
following series of commands, including the media-type configuration command:
Router# config t
Enter configuration commands, one per line. End with CNTL/Z.
Router(config)# int fa 3/0/0
Router(config-if)# media-type mii
Router(config-if)# ^Z
Router# sh int fa 3/0/0
FastEthernet3/0/0 is administratively up, line protocol is up
(display text omitted)
Encapsulation ARPA, loopback not set, keepalive not set, hdx, MII
(display text omitted)
Use the media-type 100BaseTX configuration command to return the interface to its default state
for RJ-45 connections.
42 VIP-FE-TX/4E Installation and Configuration
Page 43
VIP Port Adapter Functions
The show version (or show hardware) command displays the configuration of the system hardware
(the number of each interface processor type installed), the software version, the names and sources
of configuration files, and the boot images. Following is an example of the show version command
used with a Cisco 7500 series system:
Router# show version
Cisco Internetwork Operating System Software
IOS (tm) GS Software (RSP-A), Version 11.1(1) [mpo 105]
Copyright (c) 1986-1995 by cisco Systems, Inc.
Compiled Fri 06-Oct-95 12:22 by mpo
Image text-base: 0x600088A0, data-base: 0x605A4000
ROM: System Bootstrap, Version 5.3(16645) [biff 571], INTERIM SOFTWARE
ROM: GS Bootstrap Software (RSP-BOOT-M), Version 11.0(1.2), MAINTENANCE INTERIME
honda uptime is 4 hours, 22 minutes
System restarted by reload
System image file is "slot0:rsp-a111-1", booted via slot0
cisco RSP2 (R4600) processor with 32768K bytes of memory.
R4600 processor, Implementation 32, Revision 2.0
Last reset from power-on
G.703/E1 software, Version 1.0.
Bridging software.
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.
Chassis Interface.
1 RVIP controllers (1 FastEthernet)(4 Ethernet).
4 Ethernet/IEEE 802.3 interfaces.
1 FastEthernet/IEEE 802.3 interfaces.
125K bytes of non-volatile configuration memory.
20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
8192K bytes of Flash internal SIMM (Sector size 256K).
No slave installed in slot 6.
Configuration register is 0x2
Note For complete VIP command descriptions and examples, refer to the publications listed in the
section “If You Need More Information” on page 2.
VIP-FE-TX/4E Installation and Configuration 43
Page 44
VIP Port Adapter Functions
4E Port Adapter
The following sections discuss the 4E port adapter, which is shown in Figure 23.
• Ethernet 10BASE-T Overview
• 4E Port Adapter Description and 10BASE-T Specifications, page 45
• 4E Port Adapter LEDs, page 47
• 4E Port Adapter Receptacles, Cables, and Pinouts, page 47
• Attaching 4E Port Adapter Interface Cables, page 49
• Configuring the 4E Interfaces, page 50
Figure 23 4E Port Adapter, Faceplate View
ENABLED
Ethernet 10BASE-T Overview
The VIP 4E port adapter provides up to four IEEE 802.3 Ethernet 10BASE-T interfaces on the VIP.
Each Ethernet 10BASE-T interface allows a maximum bandwidth of 10-Mbps, for a maximum
aggregate bandwidth of 40 Mbps. All four ports run at line speed.
The term Ethernet is commonly used for all carrier sense multiple access/collision detection
(CSMA/CD) local-area networks (LANs) that generally conform to Ethernet specifications,
including IEEE 802.3. Ethernet Version 2 and IEEE 802.3 were based on, and developed shortly
after,Ethernet Version 1. The slight differencesbetween Ethernet and IEEE 802.3 are implemented
in hardware, and both are supported automatically by the 4E without any hardware configuration
changes. Together, Ethernet and IEEE 802.3 are the most widely used LAN protocols. They are well
suited to applications where a local communication medium must carry sporadic, occasionally
heavy traffic at high peak data rates.
Stations on a CSMA/CD LAN can access the network at any time. Before sending data, the station
listens to the network to see of it is already in use. If it is, the station waits until the network is not
in use, then transmits. A collision occurs when two stations listen for network traffic, hear none, and
transmit simultaneously. When this happens, both transmissions are damaged, and the stations must
retransmit. The stations detect the collision and use backoff algorithms to determine when they
should retransmit.
0
1
2
3
LINK
1
3
0
2
ETHERNET 10BT
4497
44 VIP-FE-TX/4E Installation and Configuration
Page 45
Both Ethernet and IEEE 802.3 are broadcast networks, which means that all stations see all
transmissions. Each station must examine received frames to determine whether it is the intended
destination and, if it is, pass the frame to a higher protocollayer forprocessing. IEEE802.3 specifies
several different physical layers, and Ethernet defines only one. Each IEEE 802.3 physical layer
protocol has a name that summarizes its characteristics in the format speed/signalingmethod/segment length where speed is the LAN speed in Mbps, signaling method is the signaling
method used (either Baseband or Broadband), and segment length is the maximum length between
stations in hundreds of meters.
4E Port Adapter Description and 10BASE-T Specifications
The 4E port adapter is currently only available on the VIP-FE-TX/4E, which has a single Fast
Ethernet (FE-TX) port adapter in port adapter slot 0, and a single Ethernet 10BASE-T (4E) port
adapter in port adapter slot 1. (For a description of the FE-TX port adapter, refer to the section
“FE-TX Port Adapter” on page 29.) Figure 24 shows the VIP-FE-TX/4E.
Note VIP configurations using only one 4E port adapter and a port adapter blank, or two 4E port
adapters, are currently not supported. The FE-TX and 4E port adapters have a handle attached, but
this handle is not shown to allow a full view of detail on each port adapter’s faceplate.
VIP Port Adapter Functions
Figure 24 VIP with One FE-TX and One 4E Port Adapter Installed, Horizontal Orientation Shown
Bus connector
Microcode
Flash U17
DRAM
SIMMs
FE-TX in
port adapter
slot 0
U2
MII
U1
0
LINK
FAST ETHERNET
RJ45
0
1
2
Port adapter
handles not shown
3
LINK
1
3
0
2
4E in port
adapter
slot 1
ETHERNET-10BT
H4711
Caution
To prevent system problems, do not remove port adapters from the VIP motherboard, or
attempt to install other port adapters on the VIP motherboard.
VIP-FE-TX/4E Installation and Configuration 45
Page 46
VIP Port Adapter Functions
Table 10 summarizes the characteristics of IEEE 802.3 Ethernet and Ethernet Version 2 for
10BASE-T.
Table 10IEEE 802.3 and 10BASE-T Ethernet Version 2 Physical Characteristics
ParameterIEEE 802.3 Ethernet10BaseT Ethernet Version 2
Table 11 lists the cabling specifications for 10-Mbps transmission over UTP and STP cables.
Table 11Cable Specifications for 10-Mbps 10BASE-T
ParameterRJ-45
Cable specificationCategory 5 UTP
Maximum segment length100 m (328 ft.) for 10BASE-T
Maximum network length200 m (656 ft) (with 1 repeater)
1. Cisco Systems does not supply Category 5 UTP RJ-45 cables; these cablesare
available commercially.
2. AWG = American Wire Gauge. This gauge is specified by the EIA/TIA-568
standard.
1
, 22 to 24 AWG
2
The Ethernet specifications call the 4E device a transceiver,and it is connected to the station with a
transceiver cable. The 4E port adapter is not an end station. The IEEE 802.3 specifications refer to
the same type of device as a media attachment unit (MAU) and to the cable as an attachment unitinterface (AUI). Only transceiver cables can connect to the 4E ports directly.
46 VIP-FE-TX/4E Installation and Configuration
Page 47
4E Port Adapter LEDs
The 4E port adapter contains the enabled LED, standard on all port adapters, and a one status LED
for each port. After system initialization, the enabled LED goes on to indicate that the 4E port
adapter has been enabled for operation. (The LEDs are shown in Figure 25.) The following
conditions must be met before the enabled LED goes on:
• The 4E interface is correctly connected to the backplane and receiving power.
• The 4E-equipped VIP containsa validmicrocode versionthat has been downloaded successfully.
• The bus recognizes the 4E-equipped VIP.
If any of these conditions is not met, or if the initialization fails for other reasons, the enabled LED
does not go on.
When an RJ-45 port is active, its link LED is on when the 4E port adapter is receivinga carriersignal
from the network.
Figure 25 LEDs on the 4E Port Adapter (Horizontal Orientation Shown)
ENABLED
VIP Port Adapter Functions
3
LINK
1
3
0
4E Port Adapter Receptacles, Cables, and Pinouts
The interface connectors on the 4E port adapter are four individual RJ-45 receptacles. You can use
all four simultaneously. Each connection supports IEEE 802.3 and Ethernet 10BASE-T interfaces
compliant with appropriate standards. The RJ-45 connections require external transceivers.
Figure 26 shows the RJ-45 connectors. Table 12 lists the pinouts and signals for the RJ-45
connectors.
Figure 26 4E RJ-45 Connections, Plug and Receptacle
8 7 6 5 4 3 2 1
-
Warning
The ports labeled “Ethernet,” “10BaseT,” “Token Ring,” “Console,” and “AUX” are
safety extra-low voltage (SELV) circuits. SELV circuits should only be connected to other SELV
circuits. Because the BRI circuits are treated like telephone-network voltage, avoid connecting the
SELV circuit to the telephone network voltage (TNV) circuits. (For translated versions of this
warning, refer to the section “SELV Circuit Warning Translations” on page 57.)
2
H4492
H2936
VIP-FE-TX/4E Installation and Configuration 47
Page 48
VIP Port Adapter Functions
Table 124E RJ-45 Connector Pinout
PinDescription
1Receive Data + (RxD+)
2RxD–
3Transmit Data + (TxD+)
6TxD–
Note Referring to the RJ-45 pinout in Table 12, proper common-mode line terminations should be
used for the unused Category 5, UTP cable pairs 4/5 and 7/8. Common-mode termination reduces
the contributions to electromagnetic interference (EMI) and susceptibility to common-mode
sources. Wire pairs 4/5 and 7/8 are actively terminated in the RJ-45 port circuitry in the 4E port
adapter.
Depending on your 4E, RJ-45 interface cabling requirements, use the pinouts in Figure 27 and
Figure 28.
Figure 27 Straight-Through Cable Pinout, 4E RJ-45 Connection to a Hub or Repeater
EIP
TxD+
TxD–
RxD+
RxD–
Hub or repeater
5 RxD+
6 RxD–
3 TxD+
4 TxD–
H3137
Figure 28 Crossover Cable Pinout, 4E RJ-45 Connections Between Hubs and Repeaters
b or LAN switch
3 TxD+
6 TxD–
1 RxD+
2 RxD–
Hub or LAN switch
3 TxD+
6 TxD–
1 RxD+
2 RxD–
H3138
48 VIP-FE-TX/4E Installation and Configuration
Page 49
Attaching 4E Port Adapter Interface Cables
On a single 4E port adapter, you can use up to four RJ-45 connections.
Note RJ-45 cables are not available from Cisco Systems; they are available from outside
commercial cable vendors.
Connect RJ-45 cables to the 4E port adapter as follows:
Step 1 Attach the Category 5 UTP cable directly to the RJ-45 port on the 4E port adapter. (See
Figure 29.)
The 4E port adapter is an end station device and not a repeater. You must connect the 4E
port adapter to a repeater or hub.
Figure 29 Connecting 4E RJ-45 Cables (Horizontal Orientation—Shown without Handles)
VIP Port Adapter Functions
FAST ETHERNET
0
0
1
2
3
LINK
1
3
0
2
ETHERNET-10BT
H4713
RJ-45 cable (up to four)
To transceiver,
repeater, or DTE
Note VIP configurations using only one 4E port adapter and a port adapter blank, or two 4E port
adapters, are currently not supported. The FE-TX and 4E port adapters have a handle attached, but
this handle is not shown to allow a full view of detail on each port adapter’s faceplate.
VIP-FE-TX/4E Installation and Configuration 49
Page 50
VIP Port Adapter Functions
Step 2 Attach the ferrite bead to the RJ-45 cable (at either end), as shown in Figure 30.
Caution The ferrite bead prevents electromagnetic interference (EMI) from affecting the
4E-equipped system and is a required component for proper system operation.
Figure 30 Attaching the Ferrite Bead around the RJ-45 Cable
Step 3
This completes the 4E installation. Proceed to the section “Checking the VIP Installation” on
page 19, then to the section “Configuring the 4E Interfaces,” which follows.
Configuring the 4E Interfaces
If you installed a new 4E port adapter or if you want to change the configuration of an existing
interface, you must enter Configuration mode using the configure command. If you replaced a 4E
port adapter that was previously configured, the system will recognize the new 4E interfaces and
bring them up in their existing configuration.
After you verify that the new 4E port adapter is installed correctly (the enabled LED goes on), use
the privileged-level configure command to configure the new interfaces. Be prepared with the
information you will need, such as the following:
• Protocols you plan to route on each new interface.
• Internet protocol (IP) addresses if you plan to configure the interfaces for IP routing.
• Whether the new interfaces will use bridging.
For a summary of the configuration options available and instructions for configuring the 4E
interfaces on the VIP, refer to the Router Products Configuration Guide.
Ferrite beadRJ-45 cable
with ferrite bead
Attach the network end of your RJ-45 cable to your 10BASE-T hub or repeater, DTE, or
other external 10BASE-T equipment.
H4202
The configure command requires privileged-levelaccess to the EXEC command interpreter, which
usually requires a password. Contact your system administrator if necessary to obtain EXEC-level
access. The 4E interfaces on a VIP can both be configured at 10 Mbps, half duplex (HDX) or full
duplex (FDX), for a maximum aggregate bandwidth of 40 Mbps.
50 VIP-FE-TX/4E Installation and Configuration
Page 51
Selecting Chassis Slot, Port Adapter, and Ethernet 10BASE-T Interface Port Numbers
The following section describes how to identify chassis slot, port adapter, and Ethernet 10BASE-T
interface port numbers.
Note Although the processor slots in the seven-slot Cisco 7000 and 13-slot Cisco 7513 are
verticallyoriented and those in the five-slotCisco 7010 andCisco 7505 are horizontally oriented, all
models use the same method for slot and port numbering. (Refer to Figure 2, Figure 3, Figure 4,
Figure 5, or Figure 6 for interface processor slot orientation in your chassis.)
In the router, physical port addresses specify the actual physical location of each interface port on
the router interface processor end. (See Figure 22.) This address is composed of a three-part number
in the format chassis slot number/port adapter number/interface port number.
The first number identifies the chassis slot in which the VIP is installed (as shown in the example
system in Figure 31). The secondnumber identifies the physical port adapter numberon the VIP, and
is either 0 or 1. The interface ports on each 4E port adapter are always numbered in sequence as
interface 0 through 3.
Interface ports on the VIP maintain the same address regardless of whether other interface
processors are installed or removed. However, when you move a VIP to a different slot, the first
number in the address changes to reflect the new slot number.
VIP Port Adapter Functions
VIP-FE-TX/4E Installation and Configuration 51
Page 52
VIP Port Adapter Functions
Figure 22 shows some of the slot port adapter and interface ports of a sample Cisco 7505 system.
For example, on a FE-TX/4E VIP in slot 3, the address of the first Fast Ethernet port adapter is 3/0/0
(chassis slot 3, port adapter slot 0, and interface port 0—see the section “Selecting Chassis Slot, Port
Adapter, and Fast Ethernet Interface Port Numbers” on page 38 for the Fast Ethernet numbering
scheme), and the addresses for the Ethernet 10BASE-T interface ports on the second port adapter
(which is a 4E) are 3/1/0 through 3/1/3 (chassis slot 3, port adapter slot 1, and interface ports 0
through 3).
The first port adapter slot number is always 0. The second port adapter slot number is always 1. The
individual interface port numbers always begin with 0. The number of additional ports depends on
the number of ports on a port adapter. For example, the four 10BaseT interface ports on a 4E port
adapter in the second port adapter slot in chassis slot 3, would have the following addresses: 3/1/0,
3/1/1, 3/1/2, and 3/1/3. (See Figure 31.)
Note If you remove the 4E-equipped VIP from slot 3 and install it in slot 2, the addresses of those
same 10BASE-T ports become 2/1/0 through 2/1/3.
Figure 31 10BASE-T Interface Port Number Example (Cisco 7505 Shown)
4E port adapter
(port numbers 3/1/0, 3/1/1,
3/1/2, 3/1/3, from left to right)
ROUTE SWITCH PROCESSOR
CONSOLE
ETHERNET 10BT
LINK
3
1
3
2
0
Slot 3
Slot 2
Slot 1
Interface
processor
slots
NORMAL
EJECT
SLOT 1
SLOT 0
MII
LINK
RJ-45
0
FAST ETHERNET
CPU HALT
RESET
2
1
0
Slot 0
H4722
Note VIP configurations using only one 4E port adapter, and a port adapter blank, or two 4E port
adapters, are currently not supported.
You can identify interface ports by physically checking the slot/port adapter/interface port location
on the back of the router or by using software commands to display information about a specific
interface or all interfaces in the router.
To display information about a specific interface, use the show interfaces command with the
interface type and port address in the format show interfaces [type slot/port adapter/port].
52 VIP-FE-TX/4E Installation and Configuration
Page 53
VIP Port Adapter Functions
Followingisan example of howtheshowinterfaces [typeslot/port adapter/port] command displays
status information (including the physical slot and port address) for the interfaces you specify. In
these examples, most of the status information for each interface is omitted, and the four Ethernet
10BASE-T interfaces (0–3) are in chassis slot 3, in port adapter slot 1. (Interfaces are
administratively shut down until you enable them.)
Router# sh int e 3/1/0
Ethernet3/1/1 is administratively down, line protocol is down
Hardware is cyBus Ethernet, address is 0000.0ca5.2300 (bia 0000.0ca5.2389)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
Router# sh int e 3/1/1
Ethernet3/1/2 is administratively down, line protocol is down
Hardware is cyBus Ethernet, address is 0000.0ca5.2300 (bia 0000.0ca5.238a)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
Router# sh int e 3/1/2
Ethernet3/1/3 is administratively down, line protocol is down
Hardware is cyBus Ethernet, address is 0000.0ca5.2300 (bia 0000.0ca5.238b)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
Router# sh int e 3/1/3
Ethernet3/1/3 is administratively down, line protocol is down
Hardware is cyBus Ethernet, address is 0000.0ca5.2300 (bia 0000.0ca5.238b)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
Ethernet 10BASE-T interface port adapters are always numbered as port adapter 1 because VIPs
currently support onlyone 4E port adapter withthe FE-TX/4Econfiguration, and the 4E portadapter
is always in the second port adapter slot location (port adapter slot 1). With this VIP configuration,
a FE-TX port adapter is always in port adapter slot 0.
Note Refer to the section “Selecting Chassis Slot, Port Adapter, and Fast Ethernet Interface Port
Numbers,” on page 38, for your FE-TX interface.
VIP-FE-TX/4E Installation and Configuration 53
Page 54
VIP Port Adapter Functions
Refer to Table 13, Table 14, Table 15, Table 16, and Table 17 for the 4E port numbers associated
with the interface processor slots in your chassis.
Note Table 13, Table 14, Table 15, Table 16, and Table 17 indicate 4E interface port numbers
based on the slots in which they can be installed; they do not represent examples of maximum 4E
configurations.
Table 134E Slot, Port Adapter, and Port Numbers in a Cisco 7000
Slot 0/
1. The 4E port adapter is always installed in port adapter slot 1 on the VIP.
Withthe show interfaces type slot/port adapter/port command, use arguments such as the interface
type (ethernet, and so forth) and the slot, port adapter, and port numbers (slot/port adapter/port) to
display information about a specific Ethernet 10BASE-T interface only.
The following example of the show interfaces ethernet slot/port adapter/port command shows all
of the information specific to the first 4E interface port (interface port 0) in chassis slot 3, port
adapter slot 1:
Router# sh int e 3/1/0
Ethernet3/1/0 is administratively down, line protocol is down
Hardware is cyBus Ethernet, address is 0000.0ca5.2300 (bia 0000.0ca5.2388)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec, rely 255/255, load 1/255
Encapsulation ARPA, loopback not set, keepalive set (10 sec)
ARP type: ARPA, ARP Timeout 4:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters 2:56:26
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
0 input packets with dribble condition detected
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets, 0 restarts
0 output buffer failures, 0 output buffers swapped out
Note For complete VIP command descriptions and examples, refer to the publications listed in the
section “If You Need More Information” on page 2.
VIP-FE-TX/4E Installation and Configuration 55
Page 56
VIP Port Adapter Functions
The show version(or show hardware)command displays the configuration of the system hardware
(the number of each interface processor type installed), the software version, the names and sources
of configuration files, and the boot images. Following is an example of the show version command
used with a Cisco 7500 series system:
Router# show version
Cisco Internetwork Operating System Software
IOS (tm) GS Software (RSP-A), Version 11.1(1) [mpo 105]
Copyright (c) 1986-1995 by cisco Systems, Inc.
Compiled Fri 06-Oct-95 12:22 by mpo
Image text-base: 0x600088A0, data-base: 0x605A4000
ROM: System Bootstrap, Version 5.3(16645) [biff 571], INTERIM SOFTWARE
ROM: GS Bootstrap Software (RSP-BOOT-M), Version 11.0(1.2), MAINTENANCE INTERIME
honda uptime is 4 hours, 22 minutes
System restarted by reload
System image file is "slot0:rsp-a111-1", booted via slot0
cisco RSP2 (R4600) processor with 32768K bytes of memory.
R4600 processor, Implementation 32, Revision 2.0
Last reset from power-on
G.703/E1 software, Version 1.0.
Bridging software.
X.25 software, Version 2.0, NET2, BFE and GOSIP compliant.
Chassis Interface.
1 RVIP controllers (1 FastEthernet)(4 Ethernet).
4 Ethernet/IEEE 802.3 interfaces.
1 FastEthernet/IEEE 802.3 interfaces.
125K bytes of non-volatile configuration memory.
20480K bytes of Flash PCMCIA card at slot 0 (Sector size 128K).
8192K bytes of Flash internal SIMM (Sector size 256K).
No slave installed in slot 6.
Configuration register is 0x2
For complete descriptions of interface subcommands and the configuration options available for
VIP-related interfaces, and which support VIP functionality, refer to the publications listed in the
section “If You Need More Information” on page 2.
This configuration note is available on UniverCD,Cisco’s online library of product documentation,
or in print, and is located in the Cisco 7000, Cisco 7010, Cisco 7505, Cisco 7507, and Cisco 7513
Configuration Notes subdatabases, within the Cisco Product Documentation and Core/High-End
Routers databases.
56 VIP-FE-TX/4E Installation and Configuration
Page 57
SELV Circuit Warning Translations
Warning The ports labeled “Ethernet,” “10BaseT,” “Token Ring,” “Console,” and “AUX” are
safety extra-low voltage (SELV) circuits. SELV circuits should only be connected to other SELV
circuits. Because the BRI circuits are treated like telephone-network voltage, avoid connecting the
SELV circuit to the telephone network voltage (TNV) circuits.
Waarschuwing De poorten die "Ethernet", "10BaseT", "Token Ring", "Console" en "AUX" zijn
gelabeld, zijn veiligheidscircuits met extra lage spanning (genaamd SELV = Safety Extra-Low
Voltage). SELV-circuits mogen alleen met andere SELV-circuits verbonden worden. Omdat de
BRI-circuits op dezelfde manier als telefoonnetwerkspanning behandeld worden, mag u het
SELV-circuit niet verbinden met de telefoonnetwerkspanning (TNV) circuits.
Varoitus Portit, joissa on nimet "Ethernet", "10BaseT", "Token Ring", "Console" ja "AUX", ovat
erityisen pienen jännityksen omaavia turvallisuuspiirejä (SELV-piirejä). Tällaiset SELV-piirit tulee
yhdistääainoastaan muihinSELV-piireihin. Koskaperusluokan liitäntöjen (BasicRate Interface- eli
BRI-liitännät) jännite vastaa puhelinverkoston jännitettä, vältä SELV-piirin yhdistämistä
puhelinverkoston jännitepiireihin (TNV-piireihin).
Attention Les ports étiquetés « Ethernet », « 10BaseT », « Token Ring », « Console » et « AUX » sont
des circuits de sécurité basse tension (Safety Extra-Low Voltage ou SELV). Les circuits SELV ne
doivent être interconnectés qu'avec d'autres circuits SELV. Comme les circuits BRI sont considérés
comme des sources de tension de réseau téléphonique, éviter de connecter un circuit SELV à un
circuit de tension de réseau téléphonique (telephone network voltage ou TNV).
SELV Circuit Warning Translations
Warnung Die mit "Ethernet", "10BaseT", "Token Ring", "Console" und "AUX" beschrifteten
Buchsen sind Sicherheitskreise mit Sicherheitskleinspannung (Safety Extra-Low Voltage, SELV).
SELV-Kreise sollten ausschließlich an andere SELV-Kreise angeschlossen werden. Da die
BRI-Kreise wie Telefonnetzspannungen behandelt werden, ist der SELV-Kreis nicht an
Telefonnetzspannungskreise (TNV) anzuschließen.
Avvertenza Le porte contrassegnate da "Ethernet", "10BaseT", "TokenRing", "Console" e "AUX"
sono circuiti di sicurezza con tensione molto bassa (SELV). Icircuiti SELV devonoessere collegati
solo ad altri circuiti SELV. Dato che i circuiti BRI vengono trattati come tensioni di rete telefonica,
evitare di collegare il circuito SELV ai circuiti in cui è presente le tensione di rete telefonica (TNV).
Advarsel Utgangene merket "Ethernet", "10BaseT", "Token Ring", "Console" og "AUX" er
lavspentkretser (SELV) for ekstra sikkerhet. SELV-kretser skal kun kobles til andre SELV-kretser.
Fordi BRI-kretsene håndteres som telenettspenning, unngå å koble SELV-kretsen til kretser for
telenettspenning (TNV).
Aviso As portas "Ethernet", "10BaseT", "Token Ring", "Console", and "AUX" são circuitos de
segurança de baixa tensão (SELV). Estes circuitos deverão ser apenas ligados a outros circuitos
SELV. Devido ao facto de os circuitos BRI (Interface de Ritmo Básico) serem tratados como sendo
de tensão equivalenteà da rede telefónica, evite ligar o circuito SELV aos circuitos TNV (tensão de
rede telefónica).
¡Advertencia! Los puertos "Ethernet", "10BaseT", "Token Ring", "Console" y "AUX" son
circuitos de muy baja señal que garantizan ausencia de peligro (Safety Extra-LowVoltage = SELV).
Estos circuitos SELV deben ser conectados exclusivamentecon otros también de tipo SELV. Puesto
que los circuitos tipo BRI se comportan como aquéllos con voltajes de red telefónica, debe evitarse
conectar circuitos SELV con circuitos de voltaje de red telefónica (TNV).
Varning! Deportar som är märkta "Ethernet", "10BaseT", "Token Ring", "Console" och "AUX"är
SELV-kretsar, d.v.s. skyddskretsar med extra låg spänning (SELV: Safety Extra-Low Voltage =
skyddsklenspänning). SELV-kretsar får endast anslutas till andra SELV-kretsar. Eftersom
BRI-kretsar behandlas liksom telefonnätsspänning bör SELV-kretsen inte anslutas till
telefonnätsspänningskretsar (TNV-kretsar).
VIP-FE-TX/4E Installation and Configuration 57
Page 58
Cisco Information Online
Cisco Information Online
Cisco Information Online (CIO) is Cisco Systems’ primary, real-time support channel. Maintenance
customers and partners can self-register on CIO to obtain additional content and services.
Available 24 hours a day,7days a week, CIO providesa wealth of standard and value-added services
to Cisco’s customers and business partners. CIO services include product information, software
updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures,
descriptions of service offerings, and download access to public and authorized files.
CIO serves a wide variety of users through two interfaces that are updated and enhanced
simultaneously—a character-based version anda multimediaversion that resides on theWorldWide
Web (WWW). The character-based CIO (called “CIO Classic”) supports Zmodem, Kermit,
Xmodem, FTP, Internet e-mail, and fax download options, and is excellent for quick access to
information over lower bandwidths. The WWW version of CIO provides richly formatted
documents with photographs, figures, graphics, and video, as well as hyperlinks to related
information.
You can access CIO in the following ways:
• WWW: http://www.cisco.com
• Telnet: cio.cisco.com
• Modem: From North America, 408 526-8070; from Europe, 33 1 64 46 40 82. Use the
following terminal settings: VT100 emulation; data bits: 8; parity: none; stop bits: 1; and baud
rates up to 14.4 kbps.
For a copy of CIO’s Frequently Asked Questions (FAQ), contact cio-help@cisco.com. For
additional information, contact cio-team@cisco.com.
Note If you are a network administrator and need personal technical assistance with a Cisco
product that is under warranty or covered by a maintenance contract, contact Cisco’s Technical
Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general
information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387,
408 526-7208, or cs-rep@cisco.com.
This document is to be used in conjunction with the Cisco 7000 Hardware Installation and Maintenance, Cisco 7010 Hardware Installation and Maintenance, Cisco 7505 HardwareInstallation and Maintenance, Cisco 7507 Hardware Installation and Maintenance,and Cisco 7513 Hardware Installation and Maintenance publications. (2879fe4e.fm)
AtmDirector,Catalyst,CD-PAC, CiscoFusion, Cisco IOS, the Cisco IOS logo, CiscoPro, Cisco Systems, CiscoView,CiscoVision, CiscoWorks,ClickStart,ControlStream,EtherChannel,
HubSwitch,LAN
SwitchBank, SwitchProbe, SwitchVision, SynchroniCD, The Cell, TokenSwitch, TrafficDirector, VirtualStream, VlanDirector, WNIC, Workgroup Director, Workgroup Stack, and XCI
are trademarks, Access by Cisco and Bringing the power of internetworking to everyone are service marks, and Cisco, the Cisco Systems logo, EtherSwitch, IGRP, Kalpana, the Kalpana
logo, LightStream, and UniverCD are registered trademarks of Cisco Systems, Inc. All other trademarks, service marks, registered trademarks, or registered service marks mentioned in
this document are the property of their respective owners.