Installing Plastic Motherboard Insulator in an MGX 8850 System

Installing Backplane Plastic Insulating Cover

Use the following procedure to install the insulating cover over a system’s backplane. This procedure may be done without powering down the system.
Step 1 Open the plastic grill on the front side of the intake plenum, located directly underneath the card cage
or the fan space, using a flat blade screw driver to loosen the two recessed screws. Tilt the plastic grill forward about 45 degrees, then lift out and set it aside.
Step 2 Hold the plastic cover, shown in the drawing below, so that the 16 short tabs are facing towards you.
Short tabs
3 Tabs
43776
Corporate Headquarters: Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706. USA
Copyright © 2000. Cisco Systems, Inc. All rights reserved.
78-10389-01
Step 3 The next illustration shows the clear plastic backplane cover viewed from the bottom toward the top of
the cabinet.
43777
Underside of chassis
Step 4 Slide the clear plastic backplane cover underneath the card cage and toward the bottom of the
backplane; the flange with the 3 tabs and 2 cutouts will face the backplane.
Installing Plastic Motherboard Insulator in an MGX 8850 System
2
78-10389-01