Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
Text Part Number: OL-6422-01
Page 2
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT
NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT
ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR
THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION
PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO
LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate
radio-frequency energy. If it is not installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television
reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in
part 15 of the FCC rules. These specifications are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation.
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class
A or Class B digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct
any interference to radio or television communications at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco
equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by
using one or more of the following measures:
• Turn the television or radio antenna until the interference stops.
• Move the equipment to one side or the other of the television or radio.
• Move the equipment farther away from the television or radio.
• Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television
or radio are on circuits controlled by different circuit breakers or fuses.)
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE
PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL
DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR
INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES.
Page 3
CCSP, the Cisco Square Bridge logo, Cisco Unity, Follow Me Browsing, FormShare, and StackWise are trademarks of Cisco Systems, Inc.; Changing
the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP,
CCIE, CCIP, CCNA, CCNP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the
Cisco Systems logo, Empowering the Internet Generation, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, GigaDrive, GigaStack,
HomeLink, Internet Quotient, IOS, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, LightStream, Linksys, MeetingPlace, MGX, the
Networkers logo, Networking Academy, Network Registrar, Packet , PIX, Post-Routing, Pre-Routing, ProConnect, RateMUX, Registrar, ScriptShare,
SlideCast, SMARTnet, StrataView Plus, SwitchProbe, TeleRouter, The Fastest Way to Increase Your Internet Quotient, TransPath, and VCO are
registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (0406R)
Removing Screws from the Switch 2-10
Attaching Brackets to the Catalyst 2970 Switch 2-11
Mounting the Switch in a Rack 2-18
Attaching the Cable Guide 2-19
Wall-Mounting 2-20
Attaching the Brackets to the Switch for Wall-Mounting 2-20
Attaching the RPS Connector Cover 2-20
Installing and Removing SFP Modules 2-23
Installing SFP Modules into SFP Module Slots 2-24
Catalyst 2970 Switch Hardware Installation Guide
vi
Mounting the Switch on a Wall 2-21
Table- or Shelf-Mounting 2-23
OL-6422-01
Page 7
Removing SFP Modules from SFP Module Slots 2-26
Connecting to the 10/100/1000 Ports 2-27
Connecting to SFP Modules 2-30
Connecting to Fiber-Optic SFP Modules 2-30
Connecting to 1000BASE-T SFP Modules 2-31
Where to Go Next 2-34
Contents
CHAPTER
APPENDIX
APPENDIX
3Troubleshooting 3-1
Understanding POST Results 3-1
Diagnosing Problems 3-2
ATechnical Specifications A-1
BConnector and Cable Specifications B-1
Connector Specifications B-1
10/100/1000 Ports B-1
Connecting to 10BASE-T- and 100BASE-TX-Compatible Devices B-2
Connecting to 1000BASE-T Devices B-2
SFP Module Ports B-3
Console Port B-4
Cable and Adapter Specifications B-5
Two Twisted-Pair Cable Pinouts B-5
Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports B-5
Crossover Cable and Adapter Pinouts B-7
APPENDIX
CConfiguring the Switch with the CLI-Based Setup Program C-1
Accessing the CLI C-2
OL-6422-01
Identifying a Crossover Cable B-7
Adapter Pinouts B-7
Catalyst 2970 Switch Hardware Installation Guide
vii
Page 8
I
NDEX
Contents
Accessing the CLI Through Express Setup C-2
Accessing the CLI Through the Console Port C-3
Taking Out What You Need C-4
Connecting to the Console Port C-5
Starting the Terminal Emulation Software C-6
Connecting to a Power Source C-7
Entering the Initial Configuration Information C-8
IP Settings C-8
Completing the Setup Program C-9
Catalyst 2970 Switch Hardware Installation Guide
viii
OL-6422-01
Page 9
Audience
Preface
This guide is for the networking or computer technician responsible for installing
the Catalyst 2970 switch, hereafter known as the switch. We assume that you are
familiar with the concepts and terminology of Ethernet and local area networking.
Purpose
This guide describes the hardware features of the Catalyst 2970 switch. It
describes the physical and performance characteristics of the switch, explains
how to install it, and provides troubleshooting information.
This guide does not describe system messages that you might receive or how to
configure your switch. For more information, refer to the switch software
configuration guide, the switch command reference, and the switch system
message guide on the Cisco.com Product Documentation home page. For
information about the standard Cisco IOS Release 12.1 or 12.2 commands, see
the Cisco IOS documentation set from the Cisco.com home page at Service and Support > Technical Documents. On the Cisco Product Documentation home
page, select Release 12.1 or 12.2 from the Cisco IOS Software drop-down list.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
ix
Page 10
Organization
Organization
This guide is organized into these chapters:
Chapter 1, “Product Overview,” is a physical and functional overview of the
Catalyst 2970 switch. It describes the switch ports, the standards they support,
and the switch LEDs.
Chapter 2, “Switch Installation,” contains the procedures on how to power the
switch, how to install the switch in a rack, on a wall, on a table, or on a shelf, and
how to make port connections.
Chapter 3, “Troubleshooting,” describes how to identify and resolve some of the
problems that might arise when installing the switch.
Appendix A, “Technical Specifications,” lists the physical and environmental
specifications for the switches.
Preface
Appendix B, “Connector and Cable Specifications,” describes the connectors,
cables, and adapters that can be used to connect to the switch.
Appendix C, “Configuring the Switch with the CLI-Based Setup Program,” has
an installation and setup procedure for a standalone switch.
Conventions
This document uses these conventions and symbols for notes, cautions, and
warnings:
NoteMeans reader take note. Notes contain helpful suggestions or references to
materials not contained in this manual.
Catalyst 2970 Switch Hardware Installation Guide
x
OL-6422-01
Page 11
Preface
Conventions
CautionMeans reader be careful. In this situation, you might do something that could
result in equipment damage or loss of data.
Warning
Waarschuwing
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause
bodily injury. Before you work on any equipment, be aware of the hazards
involved with electrical circuitry and be familiar with standard practices for
preventing accidents. Use the statement number provided at the end of each
warning to locate its translation in the translated safety warnings that
accompanied this device.
SAVE THESE INSTRUCTIONS
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat
werken, dient u zich bewust te zijn van de bij elektrische schakelingen
betrokken risico's en dient u op de hoogte te zijn van de standaard praktijken
om ongelukken te voorkomen. Gebruik het nummer van de verklaring
onderaan de waarschuwing als u een vertaling van de waarschuwing die bij
het apparaat wordt geleverd, wilt raadplegen.
BEWAAR DEZE INSTRUCTIES
Varoitus
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia
vammoja. Ennen kuin käsittelet laitteistoa, huomioi sähköpiirien
käsittelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin
ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta
varoitusten lopussa näkyvien lausuntonumeroiden avulla.
SÄILYTÄ NÄMÄ OHJEET
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
xi
Page 12
Conventions
Preface
Attention
Warnung
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées
pour éviter les accidents. Pour prendre connaissance des traductions des
avertissements figurant dans les consignes de sécurité traduites qui
accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la
fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die
zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit
den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur
Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung
angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den
übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät
ausgeliefert wurden.
Avvertenza
BEWAHREN SIE DIESE HINWEISE GUT AUF.
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe
causare infortuni alle persone. Prima di intervenire su qualsiasi
apparecchiatura, occorre essere al corrente dei pericoli relativi ai circuiti
elettrici e conoscere le procedure standard per la prevenzione di incidenti.
Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per
individuare le traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
Catalyst 2970 Switch Hardware Installation Guide
xii
OL-6422-01
Page 13
Preface
Conventions
Advarsel
Aviso
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade
på person. Før du begynner å arbeide med noe av utstyret, må du være
oppmerksom på farene forbundet med elektriske kretser, og kjenne til
standardprosedyrer for å forhindre ulykker. Bruk nummeret i slutten av hver
advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som
fulgte med denne enheten.
TA VARE PÅ DISSE INSTRUKSJONENE
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá
ser causadora de lesões corporais. Antes de iniciar a utilização de qualquer
equipamento, tenha conhecimento dos perigos envolvidos no manuseio de
circuitos elétricos e familiarize-se com as práticas habituais de prevenção de
acidentes. Utilize o número da instrução fornecido ao final de cada aviso para
localizar sua tradução nos avisos de segurança traduzidos que acompanham
este dispositivo.
GUARDE ESTAS INSTRUÇÕES
¡Advertencia!
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física.
Antes de manipular cualquier equipo, considere los riesgos de la corriente
eléctrica y familiarícese con los procedimientos estándar de prevención de
accidentes. Al final de cada advertencia encontrará el número que le ayudará
a encontrar el texto traducido en el apartado de traducciones que acompaña
a este dispositivo.
GUARDE ESTAS INSTRUCCIONES
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
xiii
Page 14
Conventions
Preface
Varning!
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan
leda till personskada. Innan du utför arbete på någon utrustning måste du vara
medveten om farorna med elkretsar och känna till vanliga förfaranden för att
förebygga olyckor. Använd det nummer som finns i slutet av varje varning för
att hitta dess översättning i de översatta säkerhetsvarningar som medföljer
denna anordning.
SPARA DESSA ANVISNINGAR
Catalyst 2970 Switch Hardware Installation Guide
xiv
OL-6422-01
Page 15
Preface
Related Publications
Related Publications
You can order printed copies of documents with a DOC-xxxxxx= number. For
more information, see the “Obtaining Documentation” section on page xvi.
These documents provide complete information about the switch and are available
from this Cisco.com site:
•Catalyst 2970 Switch Getting Started Guide (order number DOC-7816685=)
•Regulatory Compliance and Safety Information for the Catalyst 2970 Switch
(order number DOC-7816686=)
•Release Notes for the Catalyst 2970 Switch (not orderable but available on
Cisco.com)
NoteBefore installing, configuring, or upgrading the switch, refer to the release notes
on Cisco.com for the latest information.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
xv
Page 16
Obtaining Documentation
Preface
•Catalyst 2970 Switch Software Configuration Guide (order number
DOC-7815462=)
•Catalyst 2970 Switch Command Reference (order number DOC-7815464=)
•Catalyst 2970 Switch System Message Guide (order number DOC-7815465=)
•Device manager online help (available on the switch)
•Getting Started with Cisco Network Assistant (not orderable but available on
Cisco.com)
•Catalyst 2970 Switch Hardware Installation Guide (order number
DOC-7815469=)
•Cisco Small Form-Factor Pluggable Modules Installation Notes (order
number DOC-7815160=)
•Cisco Small Form-Factor Pluggable Modules Compatibility Matrix (not
orderable but available on Cisco.com)
•Compatibility Matrix for 1000BASE-T Small Form-Factor Pluggable
Modules (not orderable but available on Cisco.com)
•Cisco CWDM GBIC and CWDM SFP Installation Notes (not orderable but
available on Cisco.com)
Obtaining Documentation
Cisco provides several ways to obtain documentation, technical assistance, and
other technical resources. These sections explain how to obtain technical
information from Cisco Systems.
Cisco.com
You can access the most current Cisco documentation on the World Wide Web at
this URL:
http://www.cisco.com/univercd/home/home.htm
You can access the Cisco website at this URL:
http://www.cisco.com
Catalyst 2970 Switch Hardware Installation Guide
xvi
OL-6422-01
Page 17
Preface
International Cisco websites can be accessed from this URL:
Cisco documentation and additional literature are available in a Cisco
Documentation CD-ROM package, which may have shipped with your product.
The Documentation CD-ROM is updated regularly and may be more current than
printed documentation. The CD-ROM package is available as a single unit or
through an annual or quarterly subscription.
Registered Cisco.com users can order a single Documentation CD-ROM (product
number DOC-CONDOCCD=) through the Cisco Ordering tool:
•Nonregistered Cisco.com users can order documentation through a local
account representative by calling Cisco Systems Corporate Headquarters
(California, USA.) at 408 526-7208 or, elsewhere in North America, by
calling 800 553-NETS (6387).
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
xvii
Page 18
Obtaining Technical Assistance
Documentation Feedback
You can submit comments electronically on Cisco.com. On the Cisco
Documentation home page, click Feedback at the top of the page.
You can send your comments in e-mail to bug-doc@cisco.com.
You can submit comments by using the response card (if present) behind the front
cover of your document or by writing to the following address:
Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883
We appreciate your comments.
Preface
Obtaining Technical Assistance
For all customers, partners, resellers, and distributors who hold valid Cisco
service contracts, the Cisco Technical Assistance Center (TAC) provides 24-hour,
award-winning technical support services, online and over the phone. Cisco.com
features the Cisco TAC website as an online starting point for technical assistance.
Cisco TAC Website
The Cisco TAC website (http://www.cisco.com/tac) provides online documents
and tools for troubleshooting and resolving technical issues with Cisco products
and technologies. The Cisco TAC website is available 24 hours a day, 365 days a
year.
Accessing all the tools on the Cisco TAC website requires a Cisco.com user ID
and password. If you have a valid service contract but do not have a login ID or
password, register at this URL:
http://tools.cisco.com/RPF/register/register.do
Catalyst 2970 Switch Hardware Installation Guide
xviii
OL-6422-01
Page 19
Preface
Opening a TAC Case
The online TAC Case Open Tool (http://www.cisco.com/tac/caseopen) is the
fastest way to open P3 and P4 cases. (Your network is minimally impaired or you
require product information). After you describe your situation, the TAC Case
Open Tool automatically recommends resources for an immediate solution. If
your issue is not resolved using these recommendations, your case will be
assigned to a Cisco TAC engineer.
For P1 or P2 cases (your production network is down or severely degraded) or if
you do not have Internet access, contact Cisco TAC by telephone. Cisco TAC
engineers are assigned immediately to P1 and P2 cases to help keep your business
operations running smoothly.
To open a case by telephone, use one of the following numbers:
To ensure that all cases are reported in a standard format, Cisco has established
case priority definitions.
Priority 1 (P1)—Your network is “down” or there is a critical impact to your
business operations. You and Cisco will commit all necessary resources around
the clock to resolve the situation.
Priority 2 (P2)—Operation of an existing network is severely degraded, or
significant aspects of your business operation are negatively affected by
inadequate performance of Cisco products. You and Cisco will commit full-time
resources during normal business hours to resolve the situation.
Priority 3 (P3)—Operational performance of your network is impaired, but most
business operations remain functional. You and Cisco will commit resources
during normal business hours to restore service to satisfactory levels.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
xix
Page 20
Preface
Obtaining Additional Publications and Information
Priority 4 (P4)—You require information or assistance with Cisco product
capabilities, installation, or configuration. There is little or no effect on your
business operations.
Obtaining Additional Publications and Information
Information about Cisco products, technologies, and network solutions is
available from various online and printed sources.
•The Cisco Product Catalog describes the networking products offered by
Cisco Systems, as well as ordering and customer support services. Access the
Cisco Product Catalog at this URL:
•Cisco Press publishes a wide range of networking publications. Cisco
suggests these titles for new and experienced users: Internetworking Terms
and Acronyms Dictionary, Internetworking Technology Handbook,
Internetworking Troubleshooting Guide, and the Internetworking Design
Guide. For current Cisco Press titles and other information, go to Cisco Press
online at this URL:
http://www.ciscopress.com
•Packet magazine is the Cisco quarterly publication that provides the latest
networking trends, technology breakthroughs, and Cisco products and
solutions to help industry professionals get the most from their networking
investment. Included are networking deployment and troubleshooting tips,
configuration examples, customer case studies, tutorials and training,
certification information, and links to numerous in-depth online resources.
You can access Packet magazine at this URL:
http://www.cisco.com/go/packet
•iQ Magazine is the Cisco bimonthly publication that delivers the latest
information about Internet business strategies for executives. You can access
iQ Magazine at this URL:
http://www.cisco.com/go/iqmagazine
Catalyst 2970 Switch Hardware Installation Guide
xx
OL-6422-01
Page 21
Preface
Obtaining Additional Publications and Information
•Internet Protocol Journal is a quarterly journal published by Cisco Systems
for engineering professionals involved in designing, developing, and
operating public and private internets and intranets. You can access the
Internet Protocol Journal at this URL:
•Training—Cisco offers world-class networking training. Current offerings in
network training are listed at this URL:
http://www.cisco.com/en/US/learning/index.html
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
xxi
Page 22
Obtaining Additional Publications and Information
Preface
Catalyst 2970 Switch Hardware Installation Guide
xxii
OL-6422-01
Page 23
CHAPTER
1
Product Overview
The Catalyst 2970 switch—also referred to as the switch—is an Ethernet switch
to which you can connect devices like Cisco Wireless Access Point workstations,
Cisco IP Phones, and other network devices such as servers, routers, and other
switches. This chapter provides a functional overview of the Catalyst 2970
switch. These topics are included:
•Features, page 1-1
•Front Panel Description, page 1-3
•Rear Panel Description, page 1-11
•Management Options, page 1-13
Features
The Catalyst 2970 switch can be deployed as a backbone switch, aggregating
10BASE-T, 100BASE-TX, and 1000BASE-T Ethernet traffic from other network
devices. See the switch software configuration guide for examples showing how
you might deploy the switch in your network.
Catalyst 2970G-24TS—24 10/100/1000 Ethernet ports and 4 small
form-factor pluggable (SFP) module slots
•The switches support these SFP modules:
–
1000BASE-SX
–
1000BASE-LX
–
1000BASE-ZX
–
1000BASE-T
–
100BASE-FX
–
CWDM
Chapter 1 Product Overview
NoteWhen installed in Catalyst 2970 switches, 1000BASE-T SFP modules can
operate at 10, 100, or 1000 Mbps in full-duplex mode or at 10 or 100
Mbps in half-duplex mode.
•Configuration
–
10/100/1000 ports autonegotiate speed and support only full-duplex
mode.
•Switches are hot-swappable.
•Power redundancy
–
Connection for optional Cisco RPS 675 redundant power system that
operates on AC input and supplies backup DC power output to the switch.
Catalyst 2970 Switch Hardware Installation Guide
1-2
OL-6422-01
Page 25
Chapter 1 Product Overview
Front Panel Description
The 10/100/1000 ports on the Catalyst 2970G-24T switch are grouped in pairs.
The first member of the pair (port 1) is above the second member (port 2) on the
left, as shown in Figure 1-1. Port 3 is above port 4, and so on.
Figure 1-1Catalyst 2970G-24T Switch Front Panel
SYST
RPS
STAT
DUPLX
SPEED
M
O
D
E
1
2
3
4
5
6
1X
2X
7
8
9
1
0
1
1
1
2
11X
12X
1
1
3
4
1
1
5
6
1
1
7
8
13X
14X
1
2
9
0
2
2
1
2
2
2
3
4
23X
24X
Catalyst 2970
S
E
R
IE
S
Front Panel Description
87618
110/100/1000 ports
1
The 10/100/1000 ports on the Catalyst 2970G-24TS switch are grouped in pairs.
The first member of the pair (port 1) is above the second member (port 2) on the
left, as shown in Figure 1-2. Port 3 is above port 4, and so on. The SFP module
slots are numbered 25 to 28.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-3
Page 26
Front Panel Description
Figure 1-2Catalyst 2970G-24TS Switch Front Panel
SYST
RPS
STAT
DUPLX
SPEED
M
O
D
E
110/100/1000 ports2SFP module slots
1
2
3
4
5
6
1X
7
8
9
1
0
1
1
1
2
11X
12X
1
1
3
4
1
16
5
1
1
7
8
13X
14X
1
2
9
0
2
2
1
2
2
24
3
23X
24X
C
atalyst 2970
SERIES
25
26
27
28
1
2
Chapter 1 Product Overview
97400
10/100/1000 Ports
You can set the 10/100/1000 ports to operate at 10 Mbps, 100 Mbps, or
1000 Mbps in full-duplex mode. You can also set these ports for speed and duplex
autonegotiation in compliance with IEEE 802.3AB. (The default setting is
autonegotiate.) When set for autonegotiation, the port senses the speed and duplex
settings of the attached device and advertises its own capabilities. If the connected
device also supports autonegotiation, the switch port negotiates the best
connection (that is, the fastest line speed that both devices support and full-duplex
transmission if the attached device supports it) and configures itself accordingly.
In all cases, the attached device must be within 328 feet (100 meters).
Catalyst 2970 Switch Hardware Installation Guide
1-4
OL-6422-01
Page 27
Chapter 1 Product Overview
Note100BASE-TX and 1000BASE-T traffic requires Category 5 cable. 10BASE-T
traffic can use Category 3 or Category 4 cables.
When connecting the switch to workstations, servers, routers, and Cisco IP
Phones, be sure that the cable is a straight-through cable. When connecting the
switch to switches or hubs, use a crossover cable. When using a straight-through
or crossover cable for 1000BASE-T connections, be sure to use a twisted
four-pair, Category 5 cable for proper operation. Pinouts for the cables are
described in Appendix B, “Connector and Cable Specifications.”
NoteYou can use the mdix auto interface configuration command in the CLI to enable
the automatic medium-dependent interface crossover (Auto-MDIX) feature.
When the Auto-MDIX feature is enabled, the switch detects the required cable
type for copper Ethernet connections and configures the interfaces accordingly.
Therefore, you can use either a crossover or a straight-through cable for
connections to a copper 10/100/1000 or 1000BASE-T SFP module port on the
switch, regardless of the type of device on the other end of the connection.
Front Panel Description
The Auto-MDIX feature is enabled by default on switches running Cisco IOS
Release 12.2(18)SE or later. For releases between Cisco IOS
Release 12.1(14)EA1 and 12.2(18)SE, the Auto-MDIX feature is disabled by
default. For configuration information for this feature, see the switch software
configuration guide or the switch command reference.
SFP Module Slots
The Catalyst 2970 switch uses Gigabit Ethernet SFP modules to establish
fiber-optic connections. These transceiver modules are field-replaceable,
providing the uplink interfaces when inserted in an SFP module slot. You can use
the SFP modules for Gigabit uplink connections to other switches. You use
fiber-optic cables with LC or MT-RJ connectors to connect to a fiber-optic SFP
module. You use Category 5 cable with RJ-45 connectors to connect to a copper
SFP module.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-5
Page 28
Front Panel Description
LEDs
Chapter 1 Product Overview
The Catalyst 2970 models support these Cisco SFP modules:
•1000BASE-LX
•1000BASE-SX
•1000BASE-ZX
•1000BASE-T
•100BASE-FX
•CWDM
For more information about these SFP modules, see your SFP module
documentation.
You can use the switch LEDs to monitor switch activity and its performance.
Figure 1-3 shows the switch LEDs and the Mode button that you use to select one
of the port modes.
All LEDs are visible through the GUI management applications—the Network
Assistant application for multiple switches and the device manager GUI for a
single switch. The switch software configuration guide describes how to use the
command-line interface (CLI) to configure and to monitor individual switches
and switch clusters.
Catalyst 2970 Switch Hardware Installation Guide
1-6
OL-6422-01
Page 29
Chapter 1 Product Overview
Figure 1-3Catalyst 2970 Switch LEDs
SYST
MODE
RPS
STAT
DUPLX
SPEED
1
2
1X
2X
3
Front Panel Description
7
4
5
6
7
8
9
10
11
12
1X
11X
2X
12X
3654
1
2
1Mode button5RPS LED
2Speed LED6System LED
3Duplex LED7Port LEDs
4Status LED
System LED
The System LED shows whether the system is receiving power and is functioning
properly. Ta ble 1-1 lists the LED colors and their meanings.
Table 1-1System LED
ColorSystem Status
OffSystem is not powered on.
GreenSystem is operating normally.
87619
AmberSystem is receiving power but is not functioning properly.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-7
Page 30
Chapter 1 Product Overview
Front Panel Description
For information on the System LED colors during the power-on self-test (POST),
see the “Connecting to the 10/100/1000 Ports” section on page 2-27.
RPS LED
The RPS LED shows the RPS status. Table 1-2 lists the LED colors and their
meanings.
Ta b l e 1 - 2RP S L E D
ColorRPS Status
OffRPS is off or not properly connected.
GreenRPS is connected and ready to provide back-up power, if required.
Blinking greenRPS is connected but is unavailable because it is providing power to another device
(redundancy has been allocated to a neighboring device).
AmberThe RPS is in standby mode or in a fault condition. Press the Standby/Active button
on the RPS, and the LED should turn green. If it does not, the RPS fan could have
failed. Contact Cisco Systems.
Blinking amberThe internal power supply in a switch has failed, and the RPS is providing power
to the switch (redundancy has been allocated to this device).
For more information about the Cisco RPS 675, see the Cisco RPS 675 Redundant Power System Hardware Installation Guide.
Port LEDs and Modes
Each RJ-45 port and SFP module slot has a port LED. These port LEDs, as a group
or individually, display information about the switch and about the individual
ports. The port modes determine the type of information displayed through the
port LEDs. Ta ble 1-3 lists the mode LEDs and their associated port mode and
meaning.
To select or change a mode, press the Mode button until the desired mode is
highlighted. When you change port modes, the meanings of the port LED colors
also change. Tab le 1 -4 explains how to interpret the port LED colors in different
port modes.
Catalyst 2970 Switch Hardware Installation Guide
1-8
OL-6422-01
Page 31
Chapter 1 Product Overview
Front Panel Description
Table 1-3Port Mode LEDs
Mode LEDPort ModeDescription
STATPort statusThe port status. This is the default mode.
DUPLX Port duplex modeThe port duplex mode: full duplex or half duplex.
SPEEDPort speedThe port operating speed: 10, 100, or 1000 Mbps.
Table 1-4Meaning of LED Colors in Different Modes on the Switch
Port ModeLED ColorMeaning
STAT
(port status)
DUPLX
(duplex)
OffNo link, or port was administratively shut down.
GreenLink present.
Blinking greenActivity. Port is transmitting or receiving data.
Alternating
green-amber
Link fault. Error frames can affect connectivity, and errors such as
excessive collisions, CRC errors, and alignment and jabber errors
are monitored for a link-fault indication.
AmberPort is blocked by Spanning Tree Protocol (STP) and is not
forwarding data.
NoteAfter a port is reconfigured, the port LED can remain amber
for up to 30 seconds as STP checks the switch for possible
loops.
Blinking amber Port is blocked by STP and is transmitting or receiving packets.
OffPort is operating in half duplex.
GreenPort is operating in full duplex.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-9
Page 32
Chapter 1 Product Overview
Front Panel Description
Table 1-4Meaning of LED Colors in Different Modes on the Switch (continued)
Port ModeLED ColorMeaning
SPEED
10/100/1000 ports
OffPort is operating at 10 Mbps.
GreenPort is operating at 100 Mbps.
Blinking greenPort is operating at 1000 Mbps.
SFP ports
OffPort is operating at 10 Mbps.
GreenPort is operating at 100 Mbps.
Blinking greenPort is operating at 1000 Mbps.
NoteWhen installed in Catalyst 2970 switches, 1000BASE-T
SFP modules can operate at 10, 100, or 1000 Mbps in
full-duplex mode or at 10 or 100 Mbps in half-duplex mode.
Catalyst 2970 Switch Hardware Installation Guide
1-10
OL-6422-01
Page 33
Chapter 1 Product Overview
Rear Panel Description
The Catalyst 2970G-24T switch rear panel has an AC power connector, an RPS
connector, and an RJ-45 console port. (See Figure 1-4.)
Figure 1-4Catalyst 2970G-24T Switch Rear Panel
Rear Panel Description
CONSOLE
DC INPUTS FOR REMOTE
RATING
100-240V ~
1.6A-0.9A, 50-60 HZ
POWER SUPPLY
SPECIFIED IN MANUAL
+12v @13A
1234
1RJ-45 console port3AC power connector
2Fan exhaust4RPS connector
The Catalyst 2970G-24TS switch rear panel has an AC power connector, an RPS
connector, and an RJ-45 console port. (See Figure 1-5.)
87620
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-11
Page 34
Rear Panel Description
Figure 1-5Catalyst 2970G-24TS Switch Rear Panel
DC INPUTS FOR REMOTE
POWER SUPPLY
SPECIFIED IN MANUAL
CONSOLE
1234
1RJ-45 console port3AC power connector
+12v @17a
Chapter 1 Product Overview
97401
2Fan exhaust4RPS connector
Power Connectors
The switch is powered through the internal power supply. You can also connect
the Cisco RPS 675 to provide backup power if the switch internal power supply
should fail.
NoteThe Catalyst 2970 switch and the Cisco RPS 675 should be connected to the same
AC power source.
Internal Power Supply Connector
The internal power supply is an autoranging unit that supports input voltages
between 100 and 240 VAC. Use the supplied AC power cord to connect the AC
power connector to an AC power outlet.
Catalyst 2970 Switch Hardware Installation Guide
1-12
OL-6422-01
Page 35
Chapter 1 Product Overview
Cisco RPS Connector
The Cisco RPS 675 has two output levels: –48 V and 12 V, with a total maximum
output power of 675 W. Use the supplied RPS connector cable to connect the RPS
to the switch.
Management Options
Warning
Console Port
Attach only the Cisco RPS (model PWR675-AC-RPS-N1=) to the RPS receptacle.
The RPS is a redundant power system that can support six external network
devices and provides power to one failed device at a time. It automatically senses
when the internal power supply of a connected device fails and provides power to
the failed device, preventing loss of network traffic. For more information on the
Cisco RPS 675, see the Cisco RPS 675 Redundant Power System Hardware Installation Guide.
You can connect the switch to a PC by means of the console port and the supplied
RJ-45-to-DB-9 female cable. If you want to connect the switch console port to a
terminal, you need to provide an RJ-45-to-DB-25 female DTE adapter. You can
order a kit (part number ACS-DSBUASYN=) containing that adapter from Cisco.
For console port and adapter pinout information, see the “Connector and Cable
Specifications” section on page B-1.
Management Options
The Catalyst 2970 switches offer several management options:
•Network Assistant
Cisco Network Assistant is a PC-based network management GUI
application optimized for LANs of small and medium-sized businesses. Cisco
Network Assistant offers centralized management of Cisco switches ranging
from the Catalyst 2950 switch to the Catalyst 4506 switch. Through a
user-friendly GUI, users can configure and manage switch clusters or
standalone switches.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-13
Page 36
Management Options
Chapter 1 Product Overview
Cisco Network Assistant is available at no cost and can be downloaded from
this URL:
http://www.cisco.com/go/networkassistant
For information on starting the Network Assistant application, see the Getting Started with Cisco Network Assistant guide on Cisco.com.
•Device manager
You can use the device manager, which is in the switch memory, to manage
individual and standalone switches. Device manager is an easy-to-use web
interface that offers quick configuration and monitoring. You can access the
device manager from anywhere in your network through a web browser. For
more information, see the device manager online help.
•Cisco IOS command-line interface (CLI)
The switch CLI is based on Cisco IOS software and is enhanced to support
desktop-switching features. You can fully configure and monitor the switch
and switch cluster members from the CLI. You can access the CLI either by
connecting your management station directly to the switch console port or by
using Telnet from a remote management station. See the Catalyst 2970 Switch Command Reference on Cisco.com for more information.
For setup instructions that use the CLI, go to Appendix C, “Configuring the
Switch with the CLI-Based Setup Program.”
•CiscoView application
The CiscoView device-management application displays the switch image
that you can use to set configuration parameters and to view switch status and
performance information. The CiscoView application, which you purchase
separately, can be a standalone application or part of a Simple Network
Management Protocol (SNMP) platform. See the CiscoView documentation
for more information.
•SNMP network management
You can manage switches from a SNMP-compatible management station that
is running platforms such as HP OpenView or SunNet Manager. The switch
supports a comprehensive set of Management Information Base (MIB)
extensions and four Remote Monitoring (RMON) groups. See the switch
software configuration guide on Cisco.com and the documentation that came
with your SNMP application for more information.
Catalyst 2970 Switch Hardware Installation Guide
1-14
OL-6422-01
Page 37
Chapter 1 Product Overview
Network Configurations
See the switch software configuration guide on Cisco.com for an explanation of
network configuration concepts. The software configuration guide also provides
examples of network configurations that use the switch to create dedicated
network segments that are interconnected through Gigabit Ethernet connections.
Management Options
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
1-15
Page 38
Management Options
Chapter 1 Product Overview
Catalyst 2970 Switch Hardware Installation Guide
1-16
OL-6422-01
Page 39
CHAPTER
2
Switch Installation
This chapter describes how to start your switch and how to interpret the power-on
self-test (POST) that ensures proper operation. It also describes how to install the
switch and how to make connections to the switch. Read the topics and perform
the procedures in this order:
•Preparing for Installation, page 2-1
•Verifying Switch Operation, page 2-8
•Installing the Switch, page 2-9
•Installing and Removing SFP Modules, page 2-23
•Connecting to the 10/100/1000 Ports, page 2-27
•Connecting to SFP Modules, page 2-30
•Where to Go Next, page 2-34
Preparing for Installation
This section covers these topics:
•Warnings, page 2-2
•Installation Guidelines, page 2-5
•Verifying Package Contents, page 2-7
•Verifying Switch Operation, page 2-8
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-1
Page 40
Preparing for Installation
Warnings
Chapter 2 Switch Installation
These warnings are translated into several languages in the Regulatory
Compliance and Safety Information for the Catalyst 2970 Switch document that
shipped with the switch.
Warning
Warning
Warning
Warning
Warning
Attach only the Cisco RPS (model PWR675-AC-RPS-N1) to the RPS receptacle.
Statement 100C
Only trained and qualified personnel should be allowed to install, replace, or
service this equipment.
Statement 1030
Read the installation instructions before connecting the system to the power
source.
Statement 1004
Before working on equipment that is connected to power lines, remove jewelry
(including rings, necklaces, and watches). Metal objects will heat up when
connected to power and ground and can cause serious burns or weld the metal
object to the terminals.
Statement 43
Do not stack the chassis on any other equipment. If the chassis falls, it can
cause severe bodily injury and equipment damage.
Statement 48
Warning
The plug-socket combination must be accessible at all times, because it serves
as the main disconnecting device.
Warning
This equipment is intended to be grounded. Ensure that the host is connected to
earth ground during normal use.
Catalyst 2970 Switch Hardware Installation Guide
2-2
Statement 1019
Statement 39
OL-6422-01
Page 41
Chapter 2 Switch Installation
Preparing for Installation
Warning
Warning
Warning
Warning
When installing or replacing the unit, the ground connection must always be
made first and disconnected last.
Statement 1046
To prevent the switch from overheating, do not operate it in an area that
exceeds the maximum recommended ambient temperature of 113°F (45°C). To
prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance around
the ventilation openings.
Statement 17B
Do not work on the system or connect or disconnect cables during periods of
lightning activity.
Statement 3
Ultimate disposal of this product should be handled according to all national
laws and regulations.
Statement 1040
.
Warning
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
•This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
•When mounting this unit in a partially filled rack, load the rack from the bottom to the
top with the heaviest component at the bottom of the rack.
•If the rack is provided with stabilizing devices, install the stabilizers before mounting
or servicing the unit in the rack.
Statement 1006
If a redundant power system (RPS) is not connected to the switch, install an RPS
connector cover on the back of the switch.
Statement 265
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-3
Page 42
Preparing for Installation
Chapter 2 Switch Installation
Warning
Warning
Warning
Warning
Warning
To comply with safety regulations, mount switches on a wall with the front
panel facing up.
Statement 266
This unit is intended for installation in restricted access areas. A restricted
access area can be accessed only through the use of a special tool, lock and
key, or other means of security.
Statement 1017
Ethernet cables must be shielded when used in a central office environment.
Statement 171
Avoid direct exposure to the laser beam.
Statement 1012
Invisible laser radiation may be emitted from disconnected fibers or
connectors. Do not stare into beams or view directly with optical instruments.
Statement 1051
2-4
Warning
Catalyst 2970 Switch Hardware Installation Guide
Class 1 laser product.
Statement 1008
OL-6422-01
Page 43
Chapter 2 Switch Installation
Installation Guidelines
When determining where to place the switch, be sure to observe these
requirements:
•For 10/100/1000 ports, including 1000BASE-T SFP module ports, cable
lengths from the switch to connected devices are up to 328 feet (100 meters).
•Table 2- 1 lists the cable specifications for 1000BASE-SX, 1000BASE-LX,
and 1000BASE-ZX fiber-optic SFP module connections. Each port must
match the wave-length specifications on the other end of the cable, and the
cable must not exceed the stipulated cable length for reliable
communications.
Table 2-1Fiber-Optic SFP Module Port Cabling Specifications
Modal
SFP Module
Wavelength
(nanometers)Fiber Type
Core Size
(micron)
Bandwidth
(MHz/km)Cable Distance
Preparing for Installation
1000BASE-SX850MMF62.5
62.5
50
50
1000BASE-LX/LH1300MMF
1
62.5
50
SMF
50
9/10
160
200
400
500
500
400
500
—
722 feet (220 m)
902 feet (275 m)
1640 feet (500 m)
1804 feet (550 m)
1804 feet (550 m)
1804 feet (550 m)
1804 feet (550 m)
32,810 feet (10 km)
1000BASE-ZX1550SMF9/10—43.4 to 62 miles (70
2
100BASE-FXMin.: 1270
Typical: 1300
MMF50/125
62.5/125
to 100 km)
5006,562 feet (2 km)
Max.: 1380
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-5
Page 44
Preparing for Installation
Table 2-1Fiber-Optic SFP Module Port Cabling Specifications
Modal
SFP Module
Wavelength
(nanometers)Fiber Type
Core Size
(micron)
Bandwidth
(MHz/km)Cable Distance
Chapter 2 Switch Installation
CWDM1470, 1490,
SMF9/125—62 miles (100 km)
1510, 1530,
1550, 1570,
1590, 1610
1. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and
a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH
SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the SFP module
and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is required for link
distances greater than 984 feet (300 m).
2. 1000BASE-ZX SFP modules can reach up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF;
the distance depends on the fiber quality, the number of splices, and the connectors.
NoteWhen using shorter lengths of single-mode fiber cable, you might need to
insert an inline optical attenuator in the link to avoid overloading the
receiver.
When the fiber-optic cable span is less than 15.43 miles (25 km), you
should insert a 5-decibel (dB) or 10-dB inline optical attenuator between
the fiber-optic cable plant and the receiving port on the 1000BASE-ZX
SFP module at each end of the link.
•Operating environment is within the ranges listed in Appendix A, “Technical
Specifications.”
•Clearance to front and rear panels is such that
–
Front-panel indicators can be easily read.
–
Access to ports is sufficient for unrestricted cabling.
–
Rear-panel power connector is within reach of an AC power receptacle.
•Cabling is away from sources of electrical noise, such as radios, power lines,
and fluorescent lighting fixtures. Make sure the cabling is safely away from
other devices that might damage the cables.
Catalyst 2970 Switch Hardware Installation Guide
2-6
OL-6422-01
Page 45
Chapter 2 Switch Installation
•Airflow around the switch and through the vents is unrestricted.
•Temperature around the unit does not exceed 113°F (45°C).
NoteIf the switch is installed in a closed or multirack assembly, the
temperature around it might be greater than normal room temperature.
Verifying Package Contents
NoteCarefully remove the contents from the shipping container, and check each item
for damage. If any item is missing or damaged, contact your Cisco representative
or reseller for support. Return all packing material to the shipping container, and
save it.
Preparing for Installation
The switch is shipped with these items:
•Catalyst 2970 Switch Getting Started Guide
•Regulatory Compliance and Safety Information for the Catalyst 2970 Switch
•AC power cord (AC-powered switches)
•One RJ-45-to-DB-9 adapter cable
•Mounting kit containing:
–
Four rubber feet for mounting the switch on a table
–
Two 19-inch rack-mounting brackets (also used for wall mounting)
–
Six Phillips flat-head screws for attaching the brackets to the switch
–
Four Phillips machine screws for attaching the brackets to a rack
–
One cable guide and one black Phillips machine screw for attaching the
cable guide to one of the mounting brackets
–
One Redundant Power System (RPS) connector cover (for wall
mounting)
–
Two Phillips pan-head screws (for attaching the RPS cover)
–
Four Phillips truss-head screws (for wall-mounting brackets)
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-7
Page 46
Preparing for Installation
Verifying Switch Operation
Before installing the switch in a rack, on a wall, or on a table or shelf, you should
power the switch and verify that the switch passes POST.
If your configuration has an RPS, connect the switch and the RPS to the same AC
power source. See the “Power Connectors” section on page 1-12, and see the
Cisco RPS documentation for more information.
NoteAlways put the RPS in standby mode when you are connecting devices to it and
in active mode during normal operation.
To power on the switch, connect one end of the AC power cord to the AC power
connector on the switch, and connect the other end of the power cord to an AC
power outlet.
Chapter 2 Switch Installation
Warning
Attach only the Cisco RPS 675 (model PWR675-AC-RPS-N1=) to the RPS
receptacle.
As the switch powers on, it begins the power-on self test (POST), a series of tests
that runs automatically to ensure that the switch functions properly. POST lasts
approximately 1 minute. When the switch begins POST, the System, RPS, Status,
Duplex, and Speed LEDs turn green. The System LED blinks green, and the other
LEDs remain solid green.
When the POST completes successfully, the System LED remains green. The RPS
LED remains green for some time and then reflects the switch operating status.
The other LEDs turn off and then reflect the switch operating status. If a switch
fails POST, the System LED turns amber.
NotePOST failures are usually fatal. Call Cisco Systems if your switch does not pass
POST.
After a successful POST, disconnect the power cord from the switch. Install the
switch in a rack, on a wall, on a table, or on a shelf as described in the “Installing
the Switch” section on page 2-9.
Catalyst 2970 Switch Hardware Installation Guide
2-8
OL-6422-01
Page 47
Chapter 2 Switch Installation
Installing the Switch
This section describes these installation procedures:
•Rack-Mounting, page 2-9
•Wall-Mounting, page 2-20
•Table- or Shelf-Mounting, page 2-23
Rack-Mounting
Installing the Switch
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
•This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
•When mounting this unit in a partially filled rack, load the rack from the bottom to the
top with the heaviest component at the bottom of the rack.
•If the rack is provided with stabilizing devices, install the stabilizers before mounting
or servicing the unit in the rack.
Statement 1006
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-9
Page 48
Installing the Switch
To install the switch in a 19-inch or 24-inch rack (24-inch racks require optional
mounting hardware), follow the instructions described in these procedures:
•Removing Screws from the Switch, page 2-10
•Attaching Brackets to the Catalyst 2970 Switch, page 2-11
•Mounting the Switch in a Rack, page 2-18
•Attaching the Cable Guide, page 2-19
NoteInstalling the switch in a 24-inch rack requires an optional bracket kit not included
with the switch. You can order a kit containing the 24-inch rack-mounting
brackets and hardware from Cisco. The kit part number is RCKMNT-1RU=.
Removing Screws from the Switch
Chapter 2 Switch Installation
If you plan to install the switch in a rack, you must first remove screws in the
switch chassis so that mounting brackets can be attached. Figure 2-1 shows how
to remove the chassis screws in a Catalyst 2970G-24T switch.
Figure 2-1Removing Screws from the Catalyst 2970G-24T Switch
13
14
15
16
17
13X
14X
18
19
20
21
22
23
24
23X
24X
Catalyst 2970
S
E
R
IE
S
Figure 2-2 shows how to remove the chassis screws in a Catalyst 2970G-24TS
switch.
87642
Catalyst 2970 Switch Hardware Installation Guide
2-10
OL-6422-01
Page 49
Chapter 2 Switch Installation
Figure 2-2Removing Screws from the Catalyst 2970G-24TS Switch
Catalyst 2970
SER
IE
24
23
2
4
25
26
27
S
28
Attaching Brackets to the Catalyst 2970 Switch
Installing the Switch
97402
The bracket orientation and the brackets that you use depend on whether you are
attaching the brackets for a 19-inch or a 24-inch rack. For 19-inch racks, use
bracket part number 700-8209-01; for 24-inch racks, use bracket part number
700-13248-01. Figure 2-3 through Figure 2-14 show how to attach each type of
bracket to one side of the switch. Follow the same steps to attach the second
bracket to the opposite side.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-11
Page 50
Chapter 2 Switch Installation
Installing the Switch
Figure 2-3Attaching Brackets for 19-Inch Racks to a Catalyst 2970G-24T Switch, Front Panel
Forward
1
SYST
MODE
RPS
STAT
DUPLX
SPEED
1
2
3
4
5
1X
2X
6
7
8
9
10
11
12
1X
11X
2X
12X
87626
1Phillips flat-head screws
Figure 2-4Attaching Brackets for 19-Inch Racks to a Catalyst 2970G-24TS Switch, Front Panel
Forward
1
SYST
RP
MODE
STA
D
U
SPEED
S
T
PLX
1
2
3
4
5
1X
6
7
8
9
10
11
12
11X
12X
97403
1Phillips flat-head screws
Catalyst 2970 Switch Hardware Installation Guide
2-12
OL-6422-01
Page 51
Chapter 2 Switch Installation
Installing the Switch
Figure 2-5Attaching Brackets for 24-Inch Racks to a Catalyst 2970G-24T Switch, Front Panel
Forward
1
SYST
MODE
RPS
STAT
DUPLX
SPEED
1
2
3
4
5
1X
2X
6
7
8
9
10
11
12
1X
11X
2X
12X
87627
1Phillips flat-head screws
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-13
Page 52
Chapter 2 Switch Installation
Installing the Switch
Figure 2-6Attaching Brackets for 24-Inch Racks to a Catalyst 2970G-24TS Switch, Front Panel
Forward
1
SYST
MODE
RPS
STAT
DUPLX
SPEED
1
2
3
4
5
1X
6
7
8
9
10
11
12
11X
12X
97404
1Phillips flat-head screws
Figure 2-7Attaching Brackets for 19-Inch Racks to a Catalyst 2970G-24T Switch, Rear Panel
Forward
DC INPUTS FOR REMOTE
POWER SUPPLY
SPECIFIED IN MANUAL
+12v @13A
1
87628
1Phillips flat-head screws
Catalyst 2970 Switch Hardware Installation Guide
2-14
OL-6422-01
Page 53
Chapter 2 Switch Installation
Installing the Switch
Figure 2-8Attaching Brackets for 19-Inch Racks to a Catalyst 2970G-24TS Switch, Rear Panel
Forward
DC INPUTS FOR REMOTE
POWER SUPPLY
SPECIFIED IN MANUAL
+12v @17a
1
97405
1Phillips flat-head screws
Figure 2-9Attaching Brackets for 24-Inch Racks to a Catalyst 2970G-24T Switch, Rear Panel
Forward
D
C
IN
P
U
TS
F
O
R
R
E
PO
M
O
W
TE
E
R
S
U
S
P
P
P
E
LY
C
IFIE
D
IN
M
A
N
U
+12v @
A
L
1
3A
1
87629
1Phillips flat-head screws
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-15
Page 54
Chapter 2 Switch Installation
Installing the Switch
Figure 2-10Attaching Brackets for 24-Inch Racks to a Catalyst 2970G-24TS Switch, Rear Panel
Forward
DC INPUTS FOR REMOTE
POWER SUPPLY
SPECIFIED IN MANUAL
+12v @17a
1
1Phillips flat-head screws
Figure 2-11Attaching Brackets for 19-Inch Telco Racks to a Catalyst 2970G-24T Switch
13
14
15
16
17
13X
14X
18
19
20
21
22
23
24
23X
24X
Catalyst 2970
S
E
R
IE
S
1
87630
1Phillips flat-head screws
97406
Catalyst 2970 Switch Hardware Installation Guide
2-16
OL-6422-01
Page 55
Chapter 2 Switch Installation
Installing the Switch
Figure 2-12Attaching Brackets for 19-Inch Telco Racks to a Catalyst 2970G-24TS Switch
Catalyst 2970
24
23
24
2
5
2
6
1Phillips flat-head screws
SERIES
97407
2
7
2
8
1
Figure 2-13Attaching Brackets for 24-Inch Telco Racks to a Catalyst 2970G-24T Switch
13
14
15
16
17
13X
14X
18
19
20
21
22
23
24
23X
24X
Catalyst 2970
S
E
R
IES
1Phillips flat-head screws
1
87625
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-17
Page 56
Chapter 2 Switch Installation
Installing the Switch
Figure 2-14Attaching Brackets for 24-Inch Telco Racks to a Catalyst 2970G-24TS Switch
Catalyst 2970
SER
IE
24
23
24
2
5
26
S
2
7
2
8
1Phillips flat-head screws
Mounting the Switch in a Rack
After the brackets are attached to the switch, use the four supplied number-12
Phillips machine screws to securely attach the brackets to the rack, as shown in
Figure 2-15.
Figure 2-15Mounting the Catalyst 2970 Switch in a Rack
97408
1
SYST
RPS
STAT
DUPLX
SPEED
M
O
D
E
1
2
3
4
5
6
1X
2X
7
8
9
1
0
1
1
1
2
11X
12X
1
1Phillips machine screws
Catalyst 2970 Switch Hardware Installation Guide
2-18
1
1
3
4
1
1
5
6
1
1
7
8
13X
14X
1
2
9
0
2
2
1
2
2
2
3
4
23X
24X
Catalyst 2970
S
E
R
IE
S
87631
OL-6422-01
Page 57
Chapter 2 Switch Installation
After the switch is mounted in the rack, you need to do these tasks to complete the
installation:
•Power on the switch. See the “Verifying Switch Operation” section on
page 2-8.
•Connect to a 10/100 or 10/100/1000 port and run Express Setup. See the
Catalyst 2970 Switch Getting Started Guide for instructions
•Connect to the front-panel ports. See the “Connecting to the 10/100/1000
Ports” section on page 2-27 and the “Connecting to SFP Modules” section on
page 2-30 to complete the installation.
For configuration instructions about using the CLI setup program, go to
Appendix C, “Configuring the Switch with the CLI-Based Setup Program.”
Attaching the Cable Guide
Installing the Switch
We recommend attaching the cable guide to prevent the cables from obscuring the
front panel of the switch and the other devices installed in the rack. Use the
supplied black screw shown in Figure 2-16 to attach the cable guide to the left or
right bracket.
Figure 2-16Attaching the Cable Guide on the Catalyst 2970 Switch
S
Y
S
T
R
P
S
S
T
A
T
D
U
P
L
X
S
P
E
E
D
MODE
1
1
2
3
4
5
6
1X
7
8
9
10
11
12
11
2
X
X
12
X
13
14
15
16
17
18
13
X
19
20
21
22
23
24
2
1
4X
3X
24
X
C
atalyst 2970
S
E
R
IE
S
1Cable guide screw
87632
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-19
Page 58
Installing the Switch
Wall-Mounting
To install the switch on a wall, follow the instructions in these procedures:
•Attaching the Brackets to the Switch for Wall-Mounting, page 2-20
•Attaching the RPS Connector Cover, page 2-20
•Mounting the Switch on a Wall, page 2-21
Attaching the Brackets to the Switch for Wall-Mounting
Figure 2-17 shows how to attach a 19-inch bracket to one side of the switch.
Follow the same steps to attach the second bracket to the opposite side.
Figure 2-17Attaching the 19-inch Brackets for Wall-Mounting
Chapter 2 Switch Installation
13
14
15
16
17
13X
14X
18
19
20
21
22
23
24
23X
24X
Catalyst 2970
S
ERIES
1Phillips truss-head screws
Attaching the RPS Connector Cover
If you are not using an RPS with your switch, use the two Phillips pan-head
screws to attach the RPS connector cover to the back of the switch, as shown in
Figure 2-18.
Warning
If an RPS is not connected to the switch, install an RPS connector cover on the
back of the switch.
1
87636
Catalyst 2970 Switch Hardware Installation Guide
2-20
OL-6422-01
Page 59
Chapter 2 Switch Installation
Figure 2-18Attaching the RPS Connector Cover on the Catalyst 2970 Switch
CONSOLE
DC INPUTS FOR REMOTE
RATING
100-200V ~
1.6A-0.9A, 50-60 HZ
213
1Phillips pan-head screws3RPS connector
POWER SUPPLY
SPECIFIED IN MANUAL
+12v @13A
Installing the Switch
87634
2RPS connector cover
Mounting the Switch on a Wall
For the best support of the switch and cables, make sure the switch is attached
securely to wall studs or to a firmly attached plywood mounting backboard.
Mount the switch with the front panel facing up, as shown in Figure 2-19.
Warning
To comply with safety regulations, mount the switches on a wall with the front
panel facing up.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-21
Page 60
Installing the Switch
Figure 2-19Mounting the Switch on a Wall
S
E
I
R
E
S
0
5
7
3
t
s
y
l
a
t
a
C
X
24
X
23
4
2
23
2
2
1
2
0
2
19
8
1
17
6
1
5
X
4
1
4
1
X
3
1
13
1
Chapter 2 Switch Installation
1
X
12
1X
1
2
1
1
1
10
9
8
7
X2
6
5
4
3
2
X
1
1
K
C
A
D
E
T
E
D
S
E
X
O
P
L
M
S
P
U
T
D
R
A
T
T
S
S
A
M
S
P
T
R
S
Y
S
1User-supplied screws
After the switch is mounted on the wall, you need to do these tasks to complete
the installation:
•Power on the switch. See the “Verifying Switch Operation” section on
•Connect to a 10/100 or 10/100/1000 port and run Express Setup. See the
•Connect to the front-panel ports. See the “Connecting to the 10/100/1000
1
87633
page 2-8.
Catalyst 2970 Switch Getting Started Guide for instructions
Ports” section on page 2-27 and the “Connecting to SFP Modules” section on
page 2-30 to complete the installation.
Catalyst 2970 Switch Hardware Installation Guide
2-22
OL-6422-01
Page 61
Chapter 2 Switch Installation
For configuration instructions about using the CLI setup program, go to
Appendix C, “Configuring the Switch with the CLI-Based Setup Program.”
Table- or Shelf-Mounting
Follow these steps to install the switch on a table or shelf:
Step 1Locate the adhesive strip with the rubber feet in the mounting-kit envelope. Attach
the four rubber feet to the recessed areas on the bottom of the unit.
Step 2Place the switch on the table or shelf near an AC power source.
After the switch is mounted on the table, you need to do these tasks to complete
the installation:
•Power on the switch. See the “Verifying Switch Operation” section on
page 2-8.
Installing and Removing SFP Modules
•Connect to a 10/100 or 10/100/1000 port and run Express Setup. See the
Catalyst 2970 Switch Getting Started Guide for instructions
•Connect to the front-panel ports. See the “Connecting to the 10/100/1000
Ports” section on page 2-27 and the “Connecting to SFP Modules” section on
page 2-30 to complete the installation.
For configuration instructions about using the CLI setup program, go to
Appendix C, “Configuring the Switch with the CLI-Based Setup Program.”
Installing and Removing SFP Modules
These sections describe how to install and remove SFP modules. The modules are
inserted into the SFP module slots on the front of the Catalyst 2970G-24TS
switch. These field-replaceable modules provide uplink interfaces.
You can use any combination of SFP modules. See the Catalyst 2970 release notes
for the list of SFP modules that the Catalyst 2970G-24TS switch supports. Each
port must match the wave-length specifications on the other end of the cable, and
the cable must not exceed the stipulated cable length for reliable communications.
See the “Installation Guidelines” section on page 2-5 for cable stipulations for
SFP connections.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-23
Page 62
Installing and Removing SFP Modules
Use only Cisco SFP modules on the Catalyst 2970 switch. Each SFP module has
an internal serial EEPROM that is encoded with security information. This
encoding provides a way for Cisco to identify and validate that the SFP module
meets the requirements for the switch.
For detailed instructions on installing, removing, and cabling the SFP module, see
your SFP module documentation.
Installing SFP Modules into SFP Module Slots
Figure 2-20 shows an SFP module that has a bale-clasp latch.
CautionWe strongly recommend that you do not install or remove fiber-optic SFP modules
with cables attached because of the potential damage to the cables, the cable
connector, or the optical interfaces in the SFP module. Disconnect all cables
before removing or installing an SFP module.
Chapter 2 Switch Installation
Removing and installing an SFP module can shorten its useful life. Do not remove
and insert SFP modules more often than is absolutely necessary.
Figure 2-20SFP Module with a Bale-Clasp Latch
86575
To insert an SFP module into the module slot, follow these steps:
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface on
the chassis.
Step 2Find the send (TX) and receive (RX) markings that identify the top side of the SFP
module.
Catalyst 2970 Switch Hardware Installation Guide
2-24
OL-6422-01
Page 63
Chapter 2 Switch Installation
NoteOn some SFP modules, the send and receive (TX and RX) markings might
Step 3Align the SFP module in front of the slot opening.
Step 4Insert the SFP module into the slot until you feel the connector on the module snap
into place in the rear of the slot.
Figure 2-21Installing an SFP Module into an SFP Module Slot
Installing and Removing SFP Modules
be replaced by arrows that show the direction of the connection, either
send or receive (TX or RX).
Catalyst 2970
SERIE
24
23
24
25
26
27
S
28
Step 5For fiber-optic SFP modules, remove the dust plugs from the optical ports, and
store them for later use.
CautionDo not remove the dust plugs from the fiber-optic SFP module port or the rubber
caps from the fiber-optic cable until you are ready to connect the cable. The plugs
and caps protect the SFP module ports and cables from contamination and
ambient light.
97409
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-25
Page 64
Installing and Removing SFP Modules
Step 6Insert the cable connector into the SFP module:
–
For fiber-optic SFP modules, insert the LC or MT-RJ cable connector
into the SFP module.
–
For copper SFP modules, insert the RJ-45 cable connector into the SFP
module.
NoteWhen connecting to 1000BASE-T SFP modules, be sure to use a twisted
four-pair, Category 5 cable.
Removing SFP Modules from SFP Module Slots
Chapter 2 Switch Installation
To remove an SFP module from a module receptacle, follow these steps:
Step 1Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface on
the chassis.
Step 2Disconnect the cable from the SFP module.
TipFor reattachment, note which cable connector plug is send (TX) and which is
receive (RX).
Step 3Unlock and remove the SFP module, as shown in Figure 2-22.
If the module has a bale-clasp latch, pull the bale out and down to eject the
module. If the bale-clasp latch is obstructed and you cannot use your index finger
to open it, use a small, flat-blade screwdriver or other long, narrow instrument to
open the bale-clasp latch.
Catalyst 2970 Switch Hardware Installation Guide
2-26
OL-6422-01
Page 65
Chapter 2 Switch Installation
Figure 2-22Removing a Bale-Clasp Latch SFP Module by Using a Flat-Blade
Connecting to the 10/100/1000 Ports
Screwdriver
Catalyst 2970
S
ER
24
23
24
25
26
27
IES
28
97410
1
1Bale clasp
Step 4
Grasp the SFP module between your thumb and index finger, and carefully
remove it from the module slot.
Step 5For fiber-optic SFP modules, insert a dust plug into the optical ports of the SFP
module to keep the optical interfaces clean.
Step 6Place the removed SFP module in an antistatic bag or other protective
environment.
Connecting to the 10/100/1000 Ports
The switch 10/100/1000 ports configure themselves to operate at the speed of
attached devices. If the attached ports do not support autonegotiation, you can
explicitly set the speed and duplex parameters. Connecting devices that do not
autonegotiate or that have their speed and duplex parameters manually set can
reduce performance or result in no linkage.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-27
Page 66
Connecting to the 10/100/1000 Ports
To maximize performance, choose one of these methods for configuring the
Ethernet ports:
•Let the ports autonegotiate both speed and duplex.
•Set the port speed and duplex parameters on both ends of the connection.
Follow these steps to connect to 10BASE-T, 100BASE-TX or 1000BASE-T
devices:
CautionTo prevent electrostatic-discharge (ESD) damage, follow your normal board and
component handling procedures.
Step 1When connecting to workstations, servers, routers, and Cisco IP Phones, connect
a straight-through cable to an RJ-45 connector on the front panel. (See
Figure 2-23.) When connecting to switches or repeaters, use a crossover cable.
(See the “Cable and Adapter Specifications” section on page B-5 for cable-pinout
descriptions.)
Chapter 2 Switch Installation
NoteWhen connecting to 1000BASE-T-compatible devices, be sure to use a twisted
four-pair, Category 5 cable.
NoteYou can use the mdix auto interface configuration command in the CLI to enable
the automatic medium-dependent interface crossover (Auto-MDIX) feature.
When the Auto-MDIX feature is enabled, the switch detects the required cable
type for copper Ethernet connections and configures the interfaces accordingly.
Therefore, you can use either a crossover or a straight-through cable for
connections to a copper 10/100/1000 or 1000BASE-T SFP module port on the
switch, regardless of the type of device on the other end of the connection.
The Auto-MDIX feature is enabled by default on switches running Cisco IOS
Release 12.2(18)SE or later. For releases between Cisco IOS
Release 12.1(14)EA1 and 12.2(18)SE, the Auto-MDIX feature is disabled by
default. For configuration information for this feature, see the switch software
configuration guide or the switch command reference.
Catalyst 2970 Switch Hardware Installation Guide
2-28
OL-6422-01
Page 67
Chapter 2 Switch Installation
Step 2Connect the other end of the cable to an RJ-45 connector on the other device. The
port LED turns on when both the switch and the connected device have
established link.
The port LED is amber while Spanning Tree Protocol (STP) discovers the
topology and searches for loops. This takes about 30 seconds, and then the port
LED turns green. If the port LED does not turn on, the device at the other end
might not be turned on, or there might be a cable problem or a problem with the
adapter installed in the attached device. See Chapter 3, “Troubleshooting,” for
solutions to cabling problems.
Step 3Reconfigure and reboot the connected device if necessary.
Step 4Repeat Steps 1 through 3 to connect each device.
Figure 2-23Connecting to an Ethernet Port
Connecting to the 10/100/1000 Ports
OL-6422-01
MODE
SYST
RPS
STAT
DUPLX
SPEED
1
2
3
4
5
1X
2X
6
7
8
9
10
11
12
1X
11X
2X
12X
Catalyst 2970 Switch Hardware Installation Guide
87637
2-29
Page 68
Connecting to SFP Modules
Connecting to SFP Modules
This section describes how to connect to SFP modules. For instructions on how to
connect to fiber-optic SFP modules, see the “Connecting to Fiber-Optic SFP
Modules” section. For instructions on how to connect to copper 1000BASE-T SFP
modules, see the “Connecting to 1000BASE-T SFP Modules” section.
For instructions about how to install or remove an SFP module, see the “Installing
and Removing SFP Modules” section on page 2-23.
Connecting to Fiber-Optic SFP Modules
Follow these steps to connect a fiber-optic cable to an SFP module:
Chapter 2 Switch Installation
Warning
CautionDo not remove the rubber plugs from the SFP module port or the rubber caps from
Step 1Remove the rubber plugs from the module port and fiber-optic cable, and store
Step 2Insert one end of the fiber-optic cable into the SFP module port (see Figure 2-24).
Step 3Insert the other cable end into a fiber-optic receptacle on a target device.
Step 4Observe the port status LED.
Class 1 laser product.
the fiber-optic cable until you are ready to connect the cable. The plugs and caps
protect the SFP module ports and cables from contamination and ambient light.
Before connecting to the SFP module, be sure that you understand the port and
cabling stipulations in the “Installation Guidelines” section on page 2-5 and in the
“SFP Module Slots” section on page 1-5. See Appendix B, “Connector and Cable
Specifications” for information about the LC on the SFP module.
them for future use.
Statement 1008
The LED turns green when the switch and the target device have an established
link.
The LED turns amber while the STP discovers the network topology and searches
for loops. This process takes about 30 seconds, and then the port LED turns green.
Catalyst 2970 Switch Hardware Installation Guide
2-30
OL-6422-01
Page 69
Chapter 2 Switch Installation
97411
If the LED is off, the target device might not be turned on, there might be a cable
problem, or there might be problem with the adapter installed in the target device.
See Chapter 3, “Troubleshooting,” for solutions to cabling problems.
Figure 2-24Connecting to a Fiber-Optic SFP Module Port
Connecting to SFP Modules
Catalyst 2970
SERIES
24
23
24
25
26
27
28
1
1
1LC connector
Step 5
If necessary, reconfigure and restart the switch or target device.
Connecting to 1000BASE-T SFP Modules
Follow these steps to connect a Category 5 cable to a 1000BASE-T SFP module:
CautionTo prevent ESD damage, follow your normal board and component handling
procedures.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-31
Page 70
Connecting to SFP Modules
Step 1When connecting to servers, workstations, and routers, insert a four twisted-pair,
straight-through cable in the RJ-45 connector. When connecting to switches or
repeaters, insert a four twisted-pair, crossover cable.
NoteWhen connecting to a 1000BASE-T device, be sure to use a four twisted-pair,
Category 5 cable.
NoteYou can use the mdix auto interface configuration command in the CLI to enable
the automatic medium-dependent interface crossover (Auto-MDIX) feature.
When the Auto-MDIX feature is enabled, the switch detects the required cable
type for copper Ethernet connections and configures the interfaces accordingly.
Therefore, you can use either a crossover or a straight-through cable for
connections to a copper 10/100/1000 or 1000BASE-T SFP module port on the
switch, regardless of the type of device on the other end of the connection.
Chapter 2 Switch Installation
The Auto-MDIX feature is enabled by default on switches running Cisco IOS
Release 12.2(18)SE or later. For releases between Cisco IOS
Release 12.1(14)EA1 and 12.2(18)SE, the Auto-MDIX feature is disabled by
default. For configuration information for this feature, see the switch software
configuration guide or the switch command reference.
Catalyst 2970 Switch Hardware Installation Guide
2-32
OL-6422-01
Page 71
Chapter 2 Switch Installation
Figure 2-25Connecting to a 1000BASE-T SFP Module
Connecting to SFP Modules
Catalyst 2970
SERIE
24
23
24
25
26
27
1
1
S
28
97412
1RJ-45 connector
Step 2Insert the other cable end in an RJ-45 connector on a target device.
Step 3Observe the port status LED.
The LED turns green when the switch and the target device have an established
link.
The LED turns amber while the STP discovers the network topology and searches
for loops. This process takes about 30 seconds, and then the port LED turns green.
If the LED is off, the target device might not be turned on, there might be a cable
problem, or there might be problem with the adapter installed in the target device.
See Chapter 3, “Troubleshooting,” for solutions to cabling problems.
Step 4If necessary, reconfigure and restart the switch or target device.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
2-33
Page 72
Where to Go Next
Where to Go Next
If the default configuration is satisfactory, the switch does not need further
configuration. You can use any of these management options to change the default
configuration:
•Start the device manager, which is in the switch memory, to manage
individual and standalone switches. The device manager is an easy-to-use
web interface that offers quick configuration and monitoring. You can access
the device manager from anywhere in your network through a web browser.
For more information, see the device manager online help.
•Start the Network Assistant application, which is described in the Getting
Started with Cisco Network Assistant guide. Through this GUI, you can
configure and monitor a switch cluster or an individual switch.
•Use the CLI from the console to configure the switch as a member of a cluster
or as an individual switch. See the Catalyst 2970 Switch Software
Configuration Guide and the Catalyst 2970 Switch Command Reference on
Cisco.com for information on using the CLI with a Catalyst 2970 switch.
Chapter 2 Switch Installation
•Start an SNMP application such as the CiscoView application.
Catalyst 2970 Switch Hardware Installation Guide
2-34
OL-6422-01
Page 73
CHAPTER
3
Troubleshooting
The LEDs on the front panel provide troubleshooting information about the
switch. They show failures in the power-on self-test (POST), port-connectivity
problems, and overall switch performance. For a full description of the switch
LEDs, see the “LEDs” section on page 1-6.
You can also get statistics from the browser interface, from the command-line
interface (CLI), or from a Simple Network Management Protocol (SNMP)
workstation. See the software configuration guide, the switch command reference
guide on Cisco.com, or the documentation that came with your SNMP application
for details.
This chapter describes these topics for troubleshooting problems:
•Understanding POST Results, page 3-1
•Diagnosing Problems, page 3-2
Understanding POST Results
As the switch powers on, it begins POST, a series of tests that runs automatically
to ensure that the switch functions properly. When the switch begins POST, the
System, RPS, Status, Duplex, and Speed LEDs turn green. The System LED
blinks green, and the other LEDs are solid green.
When the POST completes successfully, the System LED remains green. The RPS
LED remains green for some time and then reflects the RPS operating status. The
other LEDs turn off and then reflect the switch operating status.
Catalyst 2970 Switch Hardware Installation Guide
OL-6422-01
3-1
Page 74
Diagnosing Problems
If a switch fails POST, the System LED turns solid amber. The RPS LED is either
solid or blinking amber. The other LEDs are off.
NotePOST failures are usually fatal. Call Cisco Systems if your switch does not pass
POST.
Diagnosing Problems
The LEDs on the front panel provide troubleshooting information about the
switch. They show POST failures, port-connectivity problems, and overall switch
performance. For a full description of the switch LEDs, see the “LEDs” section
on page 1-6.
You can also get statistics from the browser interface, from the CLI, or from an
SNMP workstation. See the software configuration guide, the switch command
reference guide on Cisco.com, or the documentation that came with your SNMP
application for details.
Chapter 3 Troubleshooting
You can access the Technical Support Website (http://www.cisco.com/tac) for a
list of known hardware problems and extensive troubleshooting documentation
including:
•Field notices
•Security advisories
•Troubleshooting resources
•Factory defaults
•Password recovery
Catalyst 2970 Switch Hardware Installation Guide
3-2
OL-6422-01
Page 75
Chapter 3 Troubleshooting
Common switch problems fall into these categories:
Table 3- 1 describes how to detect and resolve these problems.
Diagnosing Problems
•Recovery from corrupted or missing software
•Switch port problems
•Network interface cards
•Troubleshooting tools
•Poor performance
•No connectivity
•Corrupted software
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
3-3
Page 76
Diagnosing Problems
Table 3-1Common Problems and Their Solutions
SymptomPossible CauseResolution
Chapter 3 Troubleshooting
Poor performance or excessive
errors
Duplex autonegotiation mismatch.See the switch software
configuration guide for
information on identifying
autonegotiation mismatches.
Cabling distance exceeded
•
Port statistics show excessive
frame check sequence (FCS),
late-collision, or alignment
errors.
•For 10/100/1000BASE-T
•See the switch software
configuration guide for
information on displaying
port statistics.
connections:
–
The distance between the
port and the attached device
exceeds 328 feet (100
•Reduce the cable length to
within the recommended
distances.
meters).
–
If the switch is attached to a
repeater, the total distance
between the two end
•See your repeater
documentation for cabling
guidelines.
stations exceeds the cabling
guidelines.
Bad adapter in attached device
Catalyst 2970 Switch Hardware Installation Guide
3-4
•For SFP module port
connections:
–
The distance between the
SFP module port and the
attached device exceeds the
SFP module cabling
guidelines.
•
Excessive errors found in port
statistics.
•STP checking for possible
loops.
•See your SFP module
documentation for cabling
guidelines.
•Run adapter card diagnostic
utility.
•Wait 30 seconds for the port
LED to turn green.
OL-6422-01
Page 77
Chapter 3 Troubleshooting
Table 3-1Common Problems and Their Solutions (continued)
SymptomPossible CauseResolution
No connectivityIncorrect or bad cable
These are results of no link at both
ends:
Diagnosing Problems
Unreadable characters on the
management console
Amber system LED
•A crossover cable was used
when a straight-through was
required, or vice-versa.
•For the correct pinouts and
the proper application of
crossover vs.
straight-through cables, see
the “Two Tw ist ed- Pai r
Cable Pinouts” section on
page B-5.
•The cable is wired incorrectly.
•Replace with a tested good
cable.
•A crossover or straight-through
cable is wired incorrectly.
•For 1000BASE-T
connections, be sure to use
a twisted four-pair,
Category 5 cable.
•STP checking for possible
loops.
•Wait 30 seconds for the port
LED to turn green.
Incorrect baud rate.Reset the emulation software to
9600 baud.
Fatal POST error detected.Contact Cisco Systems.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
3-5
Page 78
Diagnosing Problems
Table 3-1Common Problems and Their Solutions (continued)
SymptomPossible CauseResolution
Chapter 3 Troubleshooting
The switch port is placed in
error-disabled state after SFP
module is inserted
Switch does not recognize the
SFP module
Bad or non-Cisco-approved SFP
module.
The SFP module might be installed
upside down.
The SFP module does not snap into
the slot.
Remove the SFP module from
the switch, and replace it with a
Cisco-approved module. Use the
errdisable recovery cause
gbic-invalid global
configuration command to
verify the port status, and enter a
time interval to recover from the
error-disable state.
See the switch command
reference guide for information
on the errdisable recovery
command.
Verify that the SFP module is
not installed upside down.
Remove the SFP module.
Inspect for physical damage to
the connector, the module, and
the module slot.
3-6
Replace the SFP module with a
known good SFP module.
Catalyst 2970 Switch Hardware Installation Guide
OL-6422-01
Page 79
APPENDIX
A
Technical Specifications
This appendix lists the switch technical specifications in Tabl e A -1 and
Table A- 2.
Table A-1Technical Specifications for the Catalyst 2970G-24T Switch
Environmental Ranges
Operating temperature32 to 113°F (0 to 45°C)
Storage temperature–13 to 158°F (–25 to 70°C)
Relative humidity10 to 85% (noncondensing)
OL-6422-01
Operating altitudeUp to 10,000 ft (3049 m)
Storage altitudeUp to 15,000 ft (4573 m)
Power Requirements
AC input voltage100 to 240 VAC (autoranging)
1.6 A/0.9 A, 50 to 60 Hz
DC input voltage for RPS
675
Power consumption160 W, 545 BTUs per hour
Physical Dimensions
Weight10 lb (4.55 kg)
Dimensions (H x D x W) 1.73 x 12.83 x 17.5 in. (4.39 x 32.59 x 44.45 cm)
+ 12 V@13 A
Catalyst 2970 Switch Hardware Installation Guide
A-1
Page 80
Appendix A Technical Specifications
Table A-2Specifications for the Catalyst 2970G-24TS Switch
Environmental Ranges
Operating temperature32 to 113°F (0 to 45°C)
Storage temperature–13 to 158°F (–25 to 70°C)
Relative humidity10 to 85% (noncondensing)
Operating altitudeUp to 10,000 ft (3049 m)
Storage altitudeUp to 15,000 ft (4573 m)
Power Requirements
AC input voltage100 to 240 VAC (autoranging)
2.3 A/1.5 A, 50 to 60 Hz
DC input voltages for
+ 12 V@17 A
RPS 675
Power consumption190 W, 650 BTUs per hour
Power rating0.190 kVA
Physical Dimensions
Weight12.5 lb (5.68 kg)
Dimensions (H x D x W)2.59 x 11.60 x 17.5 in. (6.59 x 29.46 x 44.45 cm)
Catalyst 2970 Switch Hardware Installation Guide
A-2
OL-6422-01
Page 81
Connector and Cable Specifications
This appendix describes the Catalyst 2970 switch ports and the cables and
adapters that you use to connect the switch to other devices.
Connector Specifications
These sections describe the connectors used with the Catalyst 2970 switch.
APPENDIX
B
10/100/1000 Ports
The 10/100/1000 Ethernet ports on the Catalyst 2970 switch use standard RJ-45
connectors. Figure B-1 shows the pinout.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
B-1
Page 82
Connector Specifications
NoteYou can use the mdix auto interface configuration command in the CLI to enable
Appendix B Connector and Cable Specifications
the automatic medium-dependent interface crossover (Auto-MDIX) feature.
When the Auto-MDIX feature is enabled, the switch detects the required cable
type for copper Ethernet connections and configures the interfaces accordingly.
Therefore, you can use either a crossover or a straight-through cable for
connections to a copper 10/100/1000 or 1000BASE-T SFP module port on the
switch, regardless of the type of device on the other end of the connection.
The Auto-MDIX feature is enabled by default on switches running Cisco IOS
Release 12.2(18)SE or later. For releases between Cisco IOS
Release 12.1(14)EA1 and 12.2(18)SE, the Auto-MDIX feature is disabled by
default. For configuration information for this feature, refer to the switch software
configuration guide or the switch command reference.
Connecting to 10BASE-T- and 100BASE-TX-Compatible Devices
When connecting the ports to 10BASE-T- and 100BASE-TX-compatible devices,
such as servers, workstations, and routers, you can use a two or four twisted-pair,
straight-through cable wired for 10BASE-T and 100BASE-TX. Figure B-4 shows
the two twisted-pair, straight-through cable schematics. Figure B-6 shows the
four twisted-pair, straight-through cable schematics.
When connecting the ports to 10BASE-T- and 100BASE-TX-compatible devices,
such as switches or repeaters, you can use a two or four twisted-pair, crossover
cable. Figure B-5 shows the two twisted-pair, crossover cable schematics.
Figure B-7 shows the four twisted-pair, crossover cable schematics.
You can use Category 3, 4, or 5 cabling when connecting to
10BASE-T-compatible devices. You must use Category 5 cabling when
connecting to 100BASE-TX-compatible devices.
Connecting to 1000BASE-T Devices
When connecting the ports to 1000BASE-T devices, such as servers,
workstations, and routers, you must use a four twisted-pair, Category 5,
straight-through cable wired for 10BASE-T, 100BASE-TX, and 1000BASE-T.
Figure B-6 shows the straight-through cable schematics.
Catalyst 2970 Switch Hardware Installation Guide
B-2
OL-6422-01
Page 83
Appendix B Connector and Cable Specifications
When connecting the ports to other devices, such as switches or repeaters, you
must use a four twisted-pair, Category 5, crossover cable. Figure B-7 shows the
crossover cable schematics.
NoteBe sure to use a four twisted-pair, Category 5 cable when connecting to a
1000BASE-T-compatible device.
NoteUse a straight-through cable to connect two ports only when one port is
designated with an X. Use a crossover cable to connect two ports when both ports
are designated with an X or when both ports do not have an X.
Figure B-110/100/1000 Port Pinouts
Connector Specifications
SFP Module Ports
The Catalyst 2970 switch uses SFP modules for fiber-optic and copper uplink
ports. Refer to the Catalyst 2970 release notes for a list of supported SFP modules.
23145678PinLabel
1
2
3
4
5
6
7
8
TP0+
TP0-
TP1+
TP2+
TP2-
TP1-
TP3+
TP3-
60915
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
B-3
Page 84
Connector Specifications
Appendix B Connector and Cable Specifications
Figure B-2Fiber-Optic SFP Module LC Connector
58476
Warning
Invisible laser radiation may be emitted from disconnected fibers or
connectors. Do not stare into beams or view directly with optical instruments.
Figure B-3Copper SFP Module RJ-45 Connector
23145678PinLabel
1
2
3
4
5
6
7
8
TP0+
TP0-
TP1+
TP2+
TP2-
TP1-
TP3+
TP3-
60915
Console Port
The console port uses an 8-pin RJ-45 connector, which is described in Ta bl e B -1
and Tab le B-2. The supplied RJ-45-to-DB-9 adapter cable is used to connect the
console port of the switch to a console PC. You need to provide a RJ-45-to-DB-25
female DTE adapter if you want to connect the switch console port to a terminal.
You can order a kit (part number ACS-DSBUASYN=) containing that adapter
from Cisco. For console port and adapter pinout information, see Ta ble B-1 and
Table B- 2.
Catalyst 2970 Switch Hardware Installation Guide
B-4
OL-6422-01
Page 85
Appendix B Connector and Cable Specifications
Cable and Adapter Specifications
These sections describe the cables and adapters used with Catalyst 2970 switches.
Two Twisted-Pair Cable Pinouts
Figure B-4 and Figure B-5 show the schematics of two twisted-pair cables for
connecting to 10BASE-T- and 100BASE-TX-compatible devices.
Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports
Figure B-6 and Figure B-7 show the schematics of four twisted-pair cables for
10/100/1000 ports on Catalyst 2970 switches.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
B-5
Page 86
Cable and Adapter Specifications
Figure B-6Four Twisted-Pair Straight-Through Cable Schematic for
SwitchRouter or PC
Appendix B Connector and Cable Specifications
10/100/1000 Ports
1 TPO+
2 TPO-
3 TP1+
6 TP1-
4 TP2+
5 TP2-
7 TP3+
8 TP3-
1 TP1+
2 TP1-
3 TPO+
6 TPO-
4 TP3+
5 TP3-
7 TP2+
8 TP2-
65272
Figure B-7Four Twisted-Pair Crossover Cable Schematics for 10/100/1000
Ports
SwitchSwitch
1 TPO+
2 TPO-
3 TP1+
1 TP0+
2 TP0-
3 TP1+
B-6
6 TP1-
4 TP2+
5 TP2-
7 TP3+
8 TP3-
Catalyst 2970 Switch Hardware Installation Guide
6 TP1-
4 TP2+
5 TP2-
7 TP3+
8 TP3-
65274
OL-6422-01
Page 87
Appendix B Connector and Cable Specifications
Crossover Cable and Adapter Pinouts
This section describes how to identify a crossover cable and also describes the
adapter pinouts.
Identifying a Crossover Cable
To identify a crossover cable, compare the two modular ends of the cable. Hold
the cable ends side-by-side, with the tab at the back. The wire connected to the
pin on the outside of the left plug should be the same color as the wire connected
to the pin on the outside of the right plug. (See Figure B-8.)
Figure B-8Identifying a Crossover Cable
Pin 1 on one connector and
pin 8 on the other connector
should be the same color.
Cable and Adapter Specifications
Adapter Pinouts
Pin 1
Pin 8
H10632
Table B- 1 lists the pinouts for the console port, the RJ-45-to-DB-9 adapter cable,
and the console device.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
B-7
Page 88
Cable and Adapter Specifications
Table B-1Console Port Signaling Using a DB-9 Adapter
Switch
Console
Port (DTE)
SignalDB-9 PinSignal
RTS8CTS
DTR6DSR
TxD2RxD
GND5GND
GND5GND
RxD3TxD
RJ-45-to-DB-9
Terminal Adapter
Appendix B Connector and Cable Specifications
Console
Device
DSR4DTR
CTS7RTS
Table B- 2 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE
adapter, and the console device.
NoteThe RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can
order a kit (part number ACS-DSBUASYN=) containing this adapter from Cisco.
Table B-2Console Port Signaling Using a DB-25 Adapter
Switch
Console
Port (DTE)
SignalDB-25 PinSignal
RJ-45-to-DB-25
Terminal Adapter
Console
Device
RTS5CTS
DTR6DSR
TxD3RxD
GND7GND
GND7GND
Catalyst 2970 Switch Hardware Installation Guide
B-8
OL-6422-01
Page 89
Appendix B Connector and Cable Specifications
Table B-2Console Port Signaling Using a DB-25 Adapter (continued)
Switch
Console
Port (DTE)
SignalDB-25 PinSignal
RJ-45-to-DB-25
Terminal Adapter
RxD2TxD
DSR20DTR
CTS4RTS
Cable and Adapter Specifications
Console
Device
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
B-9
Page 90
Cable and Adapter Specifications
Appendix B Connector and Cable Specifications
Catalyst 2970 Switch Hardware Installation Guide
B-10
OL-6422-01
Page 91
APPENDIX
C
Configuring the Switch with the
CLI-Based Setup Program
This appendix provides a command-line interface (CLI)-based setup procedure
for a standalone switch. For product overview information, see Chapter 1,
“Product Overview.” Before connecting the switch to a power source, review the
safety warnings in Chapter 2, “Switch Installation.” For installation procedures
on rack-mounting your switch, connecting to the switch ports, or connecting to
the small form-factor pluggable (SFP) modules, see Chapter 2, “Switch
Installation.”
These steps describe how to do a simple installation:
OL-6422-01
1.Accessing the CLI, page C-2
2.Taking Out What You Need, page C-4
3.Connecting to the Console Port, page C-5
4.Starting the Terminal Emulation Software, page C-6
5.Connecting to a Power Source, page C-7
6.Entering the Initial Configuration Information, page C-8
Catalyst 2970 Switch Hardware Installation Guide
C-1
Page 92
Appendix C Configuring the Switch with the CLI-Based Setup Program
Accessing the CLI
Accessing the CLI
For an unconfigured switch, you can access the CLI through Express Setup or
through the console port.
Accessing the CLI Through Express Setup
NoteExpress Setup is supported on switches running Cisco IOS Release 12.1(14)EA1
or later. If you are installing a new switch, refer to the Cisco IOS release label on
the rear panel of the switch to determine the release.
For switches running releases earlier than Cisco IOS Release 12.1(14)EA1, go to
the “Taking Out What You Need” section on page C-4.
You can access the CLI on an unconfigured switch by placing the switch in
Express Setup mode and then connecting an Ethernet port of the switch to the
Ethernet port of your PC or workstation. To put the switch into Express Setup
mode, follow the steps described in the Catalyst 3750 Switch Getting Started Guide for powering on the switch and using Express Setup.
After the switch is in Express Setup mode, open a Telnet session to the switch by
using the IP address 10.0.0.1, and enter the setup user EXEC command. See these
sections in this chapter to then configure the switch by using the CLI:
•Entering the Initial Configuration Information, page C-8
•Completing the Setup Program, page C-9
After you have entered the configuration information for the switch, save it to
flash memory by using the write memory privileged EXEC command.
NoteWhile in Express Setup mode, the IP address 10.0.0.1 remains active on the switch
until you enter the write memory
entering the write memory command.
For more information about using the CLI, refer to the command reference for this
release.
command. You lose the Telnet connection after
Catalyst 2970 Switch Hardware Installation Guide
C-2
OL-6422-01
Page 93
Appendix C Configuring the Switch with the CLI-Based Setup Program
Accessing the CLI Through the Console Port
You can access the CLI on a configured or unconfigured switch by connecting the
console port of the switch to the serial port on your PC or workstation and
accessing the switch through a Telnet session.
To access the switch through the console port, follow these steps:
•“Taking Out What You Need” section on page C-4.
•“Connecting to the Console Port” section on page C-5
•“Starting the Terminal Emulation Software” section on page C-6
•“Connecting to a Power Source” section on page C-7
•“Entering the Initial Configuration Information” section on page C-8
Accessing the CLI
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
C-3
Page 94
Appendix C Configuring the Switch with the CLI-Based Setup Program
Taking Out What You Need
Taking Out What You Need
Remove the items shown in Figure C-1 from the shipping container:
Figure C-1The Catalyst 2970 Switch, Adapter Cable, and AC Power Cord
1
S
Y
S
T
R
P
S
S
T
A
T
D
U
P
L
X
S
P
E
E
D
M
O
D
E
1
2
3
4
5
6
1X
7
8
9
1
0
1
1
1
2
11X
1
1
3
4
1
1
5
6
1
1
7
8
13X
1
2
9
0
2
2
1
2
2
2
3
12X
14X
4
Catalyst 2970
S
2
3X
2
4X
ERIES
2
5
2
6
2
7
2
8
2
3
1Catalyst 2970 switch3AC power cord
2RJ-45-to-DB-9 adapter cable
97461
NoteYou need to provide the Category 5 straight-through cables to connect the switch
ports to other Ethernet devices.
Catalyst 2970 Switch Hardware Installation Guide
C-4
OL-6422-01
Page 95
Appendix C Configuring the Switch with the CLI-Based Setup Program
NoteYou can use the mdix auto interface configuration command in the CLI to enable
the automatic medium-dependent interface crossover (Auto-MDIX) feature.
When the Auto-MDIX feature is enabled, the switch detects the required cable
type for copper Ethernet connections and configures the interfaces accordingly.
Therefore, you can use either a crossover or a straight-through cable for
connections to a copper 10/100/1000 or 1000BASE-T SFP module port on the
switch, regardless of the type of device on the other end of the connection.
The Auto-MDIX feature is enabled by default on switches running Cisco IOS
Release 12.2(18)SE or later. For releases between Cisco IOS
Release 12.1(14)EA1 and 12.2(18)SE, the Auto-MDIX feature is disabled by
default. For configuration information for this feature, refer to the switch software
configuration guide or the switch command reference.
Connecting to the Console Port
Connecting to the Console Port
You can use the console port to perform the initial configuration. To connect the
switch console port to a PC, use the supplied RJ-45-to-DB-9 adapter cable.
Follow these steps to connect the PC or terminal to the switch:
Step 1Using the supplied RJ-45-to-DB-9 adapter cable, insert the RJ-45 connector into
the console port on the rear of a switch, as shown in Figure C-2.
Step 2Attach the DB-9 female DTE of the adapter cable to a PC serial port, or attach an
appropriate adapter to the terminal.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
C-5
Page 96
Starting the Terminal Emulation Software
Figure C-2Connecting a Switch to a PC
CONSOLE
Appendix C Configuring the Switch with the CLI-Based Setup Program
Before you power on the switch, start the terminal emulation session so that you
can see the output display from the power-on self-test (POST).
97460
The terminal-emulation software—frequently a PC application such as
Hyperterminal or ProcommPlus—makes communication between the switch and
your PC or terminal possible.
Step 1Start the terminal-emulation program if you are using a PC or terminal.
Step 2Start a terminal-emulation session.
Catalyst 2970 Switch Hardware Installation Guide
C-6
OL-6422-01
Page 97
Appendix C Configuring the Switch with the CLI-Based Setup Program
Step 3Configure the baud rate and character format of the PC or terminal to match these
console port default characteristics:
•9600 baud
•8 data bits
•1 stop bit
•No parity
•None (flow control)
Connecting to a Power Source
Connecting to a Power Source
Follow these steps to connect to a power source:
Step 1Connect one end of the supplied AC power cord to the power connector on a
switch rear panel. See Figure C-2.
Step 2Connect the other end of the power cable to a grounded AC outlet.
NoteIf you are connecting the switch to a Cisco redundant power system (RPS), refer
to the documentation that shipped with your RPS.
As the switch powers on, it begins the power-on self test (POST), a series of tests
that runs automatically to ensure that the switch functions properly. POST lasts
approximately 1 minute. When the switch begins POST, the System, RPS, Status,
Duplex, and Speed LEDs turn green. The System LED blinks green, and the other
LEDs remain solid green.
When the POST completes successfully, the System LED remains green. The RPS
LED remains green for some time and then reflects the switch operating status.
The other LEDs turn off and then reflect the switch operating status. If a switch
fails POST, the System LED turns amber.
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
C-7
Page 98
Appendix C Configuring the Switch with the CLI-Based Setup Program
Entering the Initial Configuration Information
NotePOST failures are usually fatal. Call Cisco Systems if your switch does not pass
POST.
If you started the terminal emulation program before you powered on your switch,
the PC or terminal displays the bootloader sequence. You need to press Enter to
display the setup program prompt.
Entering the Initial Configuration Information
To set up the switch, you need to complete the setup program, which runs
automatically after the switch is powered up. You must assign an IP address and
other configuration information necessary for the switch to communicate with the
local routers and the Internet. This information is also required if you plan to use
the Network Assistant to configure and manage the switch.
IP Settings
You will need this information from your network administrator before you
complete the setup program:
•Switch IP address
•Subnet mask (IP netmask)
•Default gateway (router)
•Enable secret password
•Enable password
•Telnet password
Catalyst 2970 Switch Hardware Installation Guide
C-8
OL-6422-01
Page 99
Appendix C Configuring the Switch with the CLI-Based Setup Program
Completing the Setup Program
Follow these steps to complete the setup program and to create an initial
configuration for the switch:
Step 1Enter Yes at these two prompts.
Would you like to enter the initial configuration dialog? [yes/no]:
yes
At any point you may enter a question mark '?' for help.
Use ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets '[]'.
Basic management setup configures only enough connectivity
for management of the system, extended setup will ask you
to configure each interface on the system.
Entering the Initial Configuration Information
Would you like to enter basic management setup? [yes/no]: yes
Step 2Enter a host name for the switch, and press Return.
On a command switch, the host name is limited to 28 characters; on a member
switch to 31 characters. Do not use -n, where n is a number, as the last character
in a host name for any switch.
Enter host name [Switch]: host_name
Step 3Enter an enable secret password, and press Return.
The password can be from 1 to 25 alphanumeric characters, can start with a
number, is case sensitive, allows spaces, but ignores leading spaces. The secret
password is encrypted and the enable password is in plain text.
Enter enable secret: secret_password
Step 4Enter an enable password, and press Return.
Enter enable password: enable_password
Step 5Enter a virtual terminal (Telnet) password, and press Return.
The password can be from 1 to 25 alphanumeric characters, is case sensitive,
allows spaces, but ignores leading spaces.
Enter virtual terminal password: terminal-password
OL-6422-01
Catalyst 2970 Switch Hardware Installation Guide
C-9
Page 100
Entering the Initial Configuration Information
Step 6(Optional) Configure Simple Network Management Protocol (SNMP) by
responding to the prompts. You can also configure SNMP later through the CLI,
the device manager, or the Network Assistant application. To configure SNMP
later, enter no.
Configure SNMP Network Management? [no]: no
Step 7Enter the interface name (physical interface or VLAN name) of the interface that
connects to the management network, and press Return. For this release, always
use vlan1 as that interface.
Enter interface name used to connect to the
management network from the above interface summary: vlan1
Step 8Configure the interface by entering the switch IP address and subnet mask and
pressing Return. The IP address and subnet masks shown below are examples.
Configuring interface vlan1:
Configure IP on this interface? [yes]: yes
IP address for this interface: 10.4.120.106
Subnet mask for this interface [255.0.0.0]: 255.0.0.0
Appendix C Configuring the Switch with the CLI-Based Setup Program
Step 9Enter Y to configure the switch as the cluster command switch. Enter N to
configure it as a member switch or as a standalone switch.
If you enter N, the switch appears as a candidate switch in the Network Assistant
GUI. You can configure the switch as a command switch later through the CLI,
the device manager, or the Network Assistant application. To configure it later,
enter no.
Would you like to enable as a cluster command switch? [yes/no]: no
You have now completed the initial configuration of the switch, and the switch
displays its initial configuration. This is an example of output that appears:
The following configuration command script was created:
hostname switch1
enable secret 5 $1$Ulq8$DlA/OiaEbl90WcBPd9cOn1
enable password enable_password
line vty 0 15
password terminal-password
no snmp-server
!
no ip routing
!
interface Vlan1
no shutdown
Catalyst 2970 Switch Hardware Installation Guide
C-10
OL-6422-01
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.