Cisco UCS C240 M4 Server
Installation and Service Guide
August 04, 2015
Cisco Systems, Inc.
www.cisco.com
Cisco has more than 200 offices worldwide.
Addresses, phone numbers, and fax numbers
are listed on the Cisco website at
www.cisco.com/go/offices.
Text Part Number: OL-32474-01
Page 2
THE SPECIFICATIONS AND INFORMATION REGA RDING THE P RODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE W ITH OUT NOT ICE. A LL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILIT Y FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRA NTY FO R THE A CCOMPA NYING PRODUCT A RE SET FORTH IN T HE INFORM ATION P ACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required
to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be
determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV tech nician for help.
Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAI M ALL WARRANTIE S, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICUL AR PURPOS E AND NONINFRINGE MENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING,
WITHOUT LIMITATION, LOS T PROFITS OR LOSS OR DAMAGE TO DATA ARISIN G OUT OF THE US E OR INABILI TY TO USE THIS MA NUAL, EVEN I F CISCO
OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SU CH DAMA GES.
CCDE, CCENT, CCSI, Cisco Eos, Cisco Explorer, Cisco HealthPresence, Cisco IronPort, the Cisco logo, Cisco Nurse Connect, Cisco Pulse, Cisco SensorBase,
Cisco StackPower, Cisco StadiumVision, Cisco TelePresence, Cisco TrustSec, Cisco Unified Computing System, Cisco WebEx, DCE, Flip Channels, Flip for Good, Flip
Mino, Flipshare (Design), Flip Ultra, Flip Video, Flip Video (D esign), Instant Broadband, and Welcome to the Human Network are trademarks; Changi ng the Way We Work,
Live, Play, and Learn, Cisco Capital, Cisco Capital (Design), Cisco:Financed (Stylized), Cisco Store, Flip Gift Card, and One Million Acts of Green are service marks; and
Access Registrar, Aironet, AllTouch, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the
Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Lumin, Cisco Nexus, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity,
Collaboration Without Limitation, Continuum, EtherFast, EtherSwitch, Event Center, Explorer, Follow Me Browsing, GainMaker, iLYNX, IOS, iPhone, IronPort, the
IronPort logo, Laser Link, LightStream, Linksys, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, PCNow, PIX, PowerKEY,
PowerPanels, PowerT V, Po werT V (D esig n), Powe rV u, Pr isma, Pro Connect, ROSA, SenderBase, SMARTnet, Spectrum Expert, StackWise, WebEx, and the WebEx logo are
registered trademarks of Cisco and/or its affiliates in the United States and certain other countries.
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at
www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1005R)
Any Internet Protocol (IP) addresses and phone numbers us ed in th is do cumen t are not in tended to be actual addres ses and phone numbers. Any ex ampl es, co mmand di sp lay
output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in
illustrative content is unintentional and coincidental.
Cisco UCS C240 M4 Server Installation and Service Guide
Cisco UCS C240 M4 Server Installation and Service Guide
iii
Page 4
Contents
System BIOS and Cisco IMC Firmware2-15
Updating the BIOS and Cisco IMC Firmware2-15
Accessing the System BIOS 2-16
CHAPTER
3Maintaining the Server3-1
Server Monitoring and Management Tools3-1
Cisco Integrated Management Interface3-1
Server Configuration Utility3-1
Status LEDs and Buttons3-2
Front Panel LEDs3-2
Rear Panel LEDs and Buttons3-5
Internal Diagnostic LEDs3-8
Preparing for Server Component Installation3-9
Required Equipment 3-9
Shutting Down and Powering Off the Server3-9
Removing and Replacing the Server Top Cover 3-10
Serial Number Location3-12
Hot-Swap or Hot-Plug Replacement3-12
Installing or Replacing Server Components3-13
Replaceable Component Locations 3-14
Replacing Hard Drives or Solid State Drives3-15
Drive Population Guidelines3-15
Drive Replacement Procedure3-16
Replacing Fan Modules 3-18
Replacing DIMMs 3-20
Memory Performance Guidelines and Population Rules 3-20
DIMM Replacement Procedure3-23
Replacing CPUs and Heatsinks 3-24
CPU Configuration Rules3-24
Replacing a CPU and Heatsink3-24
Additional CPU-Related Parts to Order with RMA Replacement Motherboards3-27
Replacing a SATA Interposer Board3-28
Replacing a Cisco Modular RAID Controller Card3-30
Replacing a Modular RAID Controller Transportable Memory Module (TMM)3-32
Replacing the Supercap Power Module (RAID Backup Battery)3-34
Replacing a Software RAID 5 Key Module3-36
Replacing the Motherboard RTC Battery3-38
Replacing an Internal SD Card3-39
Enabling or Disabling the Internal USB Port3-40
iv
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 5
Replacing a PCIe Riser 3-41
Replacing a PCIe Card3-43
PCIe Slots3-43
Replacing a PCIe Card 3-45
Special Considerations for Cisco UCS Virtual Interface Cards3-47
Special Considerations for Cisco UCS Fusion ioDrive3 Storage Accelerator Cards3-48
Installing Multiple PCIe Cards and Resolving Limited Resources3-50
Installing an NVIDIA GPU Card3-52
Overview of Software Requirements3-52
GPU Card Configuration Rules3-52
Requirement For All Supported GPUs: Memory-Mapped I/O Greater than 4 GB3-53
Replacing a GPU Card3-54
Installing an NVIDIA K80 GPU Card and Conversion Kit3-56
Installing Drivers to Support the NVIDIA GPU Cards3-63
Replacing Internal SATA Boot Drives3-64
Replacing an Internal SATA Boot Drive3-64
Installing a Trusted Platform Modul e 3-66
Installing the TPM Hardware3-66
Enabling TPM Support in the BIOS3-67
Enabling the Intel TXT Feature in the BIOS3-68
Replacing Power Supplies 3-69
Wiring a DC Power Supply3-70
Replacing an mLOM Card3-72
Contents
APPENDIX
OL-32474-01
Service DIP Switches3-74
DIP Switch Location on the Motherboard3-74
Using the BIOS Recovery DIP Switch3-75
Procedure 1: Reboot with recovery.cap File3-75
Procedure 2: Use BIOS Recovery DIP switch and recovery.cap File3-76
Using the Clear Password DIP Switch3-77
Using the Clear CMOS DIP Switch3-78
AServer SpecificationsA-1
Physical SpecificationsA-1
Power Specifications A-2
650 W AC Power SupplyA-2
1200 W AC Power SupplyA-3
1400 W AC Power SupplyA-3
930 W DC Power SupplyA-4
Environmental Specifications A-5
Cisco UCS C240 M4 Server Installation and Service Guide
v
Page 6
Contents
APPENDIX
APPENDIX
BPower Cord SpecificationsB-1
Supported Power Cords and PlugsB-1
AC Power Cord IllustrationsB-3
CRAID Controller ConsiderationsC-1
Supported RAID Controllers and Required CablesC-2
Write-Cache Policy for Cisco 12G SAS Modular RAID ControllerC-3
Support Matrix For Cisco UCS C240 M4 Server RAID ControllersC-4
Cisco UCS SAS 9300-8e HBA ConsiderationsC-4
Mixing RulesC-4
Cisco UCS 9300-8e Bad Drive and Predictive Failure BehaviorC-4
Setting the Preferred Boot Device for Cisco UCS 9300-8eC-5
Mixing Drive Types in RAID GroupsC-6
RAID Backup UnitsC-6
RAID Controller CablingC-7
Cable RoutingC-7
Cisco UCS C240 M4 Server RAID Controller Cabling InstructionsC-8
SFF 8-Drive Direct-Connect Backplane, No ExpanderC-8
SFF 16-Drive Backplane with Integrated ExpanderC-8
SFF 24-Drive Backplane with Expander CablingC-9
LFF 12-Drive Backplane with ExpanderC-9
Embedded SATA RAID ControllerC-11
Embedded SATA RAID Controller Requirements For Front-Facing Drive ControlC-11
Embedded SATA RAID: Two SATA ControllersC-12
Embedded SATA RAID Controller ConsiderationsC-13
Installing a SATA Interposer Board For Front-Facing Drive ControlC-13
Installing a Software RAID 5 Key Module for Embedded RAID 5 SupportC-13
Enabling the Embedded RAID Controller in the BIOSC-14
Enabling SATA Mode and Selecting Option ROM ModeC-14
Disabling the Embedded RAID Controller in the BIOSC-16
Launching the LSI Embedded MegaRAID Configuration UtilitiesC-16
Installing LSI MegaSR Drivers For Windows and LinuxC-17
Downloading the LSI MegaSR DriversC-17
Microsoft Windows Driver InstallationC-18
Linux Driver InstallationC-20
Restoring RAID Configuration After Replacing a RAID ControllerC-25
For More Information C-26
vi
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 7
Contents
APPENDIX
DInstallation for Cisco UCS Manager IntegrationD-1
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
vii
Page 8
Contents
viii
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 9
Audience
Preface
This preface describes the audience, organization, and conventions of the Cisco UCS C240 M4 Server
Installation and Service Guide. It also provides information about ho w to obtain related docum entatio n.
This guide is for experienced network administrators who configure and maintain Cisco servers.
Conventions
This document uses the following conventions for notes, cautions, and safety warnings. Notes and
cautions contain important information t hat you sho uld know.
NoteMeans r eader take note. Notes contain helpful suggestions or references to material that are not cov ered
in the publication.
CautionMeans reader be careful . Cautions contain information about something you might do that could result
in equipment damage or loss of data.
Safety warnings appear throughout this guide in procedures that, if performed incorrectly, can cause
physical injuries. A warning symbol precedes each warning statement.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
ix
Page 10
Warning
Waarschuwing
Varoitus
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device.
Statement 1071
SAVE THESE INSTRUCTIONS
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwingssymbool betekent gevaar. U verkeert in een situatie die lichamelijk letsel kan
veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij
elektrische schakelingen betrokken risico's en dient u op de hoogte te zijn van de standaard
praktijken om ongelukken te voorkomen. Gebruik het nummer van de verklaring onderaan de
waarschuwing als u een vertaling van de waarschuwing die bij het apparaat wordt geleverd, wilt
raadplegen.
BEWAAR DEZE INSTRUCTIES
TÄRKEITÄ TURVALLISUUSOHJEITA
Tämä varoitusmerkki merkitsee vaaraa. Tilanne voi aiheuttaa ruumiillisia vammoja. Ennen kuin
käsittelet laitteistoa, huomioi sähköpiirien käsittelemiseen liittyvät riskit ja tutustu
onnettomuuksien yleisiin ehkäisytapoihin. Turvallisuusvaroitusten käännökset löytyvät laitteen
mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien
lausuntonumeroiden avulla.
Attention
Warnung
SÄILYTÄ NÄMÄ OHJEET
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une situation pouvant
entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez
conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures
couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des
avertissements figurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fin de chaque avertissement.
CONSERVEZ CES INFORMATIONS
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr . Sie be finden sich in einer Situation, die zu V erletzungen führen
kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und
den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder
Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
Cisco UCS C240 M4 Server Installation and Service Guide
x
OL-32474-01
Page 11
Avvertenza
Advarsel
Aviso
IMPORTANTI ISTRUZIONI SULLA SICUREZZA
Questo simbolo di avvertenza indica un pericolo. La situazione potrebbe causare infortuni alle
persone. Prima di intervenire su qualsiasi apparecchiatura, occorre essere al corrente dei pericoli
relativi ai circuiti elettrici e conoscere le procedure standard per la prevenzione di incidenti.
Utilizzare il numero di istruzione presente alla fine di ciascuna avvertenza per individuare le
traduzioni delle avvertenze riportate in questo documento.
CONSERVARE QUESTE ISTRUZIONI
VIKTIGE SIKKERHETSINSTRUKSJONER
Dette advarselssymbolet betyr fare. Du er i en situasjon som kan føre til skade på person. Før du
begynner å arbeide med noe av utstyret, må du være oppmerksom på farene forbundet med
elektriske kretser , og kjenn e til standardprosedyrer for å forhindre u lykker. Bruk nu mmeret i slutten
av hver advarsel for å finne oversettelsen i de oversatte sikkerhetsadvarslene som fulgte med denne
enheten.
TA VARE PÅ DISSE INSTRUKSJONENE
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você está em uma situação que poderá ser causadora de
lesões corporais. Antes de iniciar a utilização de qualquer equipamento, tenha conhecimento dos
perigos envolvidos no manuseio de circuitos elétricos e familiarize-se com as práticas habituais de
prevenção de acidentes. Utilize o número da instrução fornecido ao final de cada aviso para
localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo.
¡Advertencia!
Varning!
GUARDE ESTAS INSTRUÇÕES
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes de manipular
cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los
procedimientos estándar de prevención de accidentes. Al final de cada advertencia encontrará el
número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña
a este dispositivo.
GUARDE ESTAS INSTRUCCIONES
VIKTIGA SÄKERHETSANVISNINGAR
Denna varningssignal signalerar fara. Du befinner dig i en situation som kan leda till personskada.
Innan du utför arbete på någon utrustning måste du vara medveten om farorna med elkretsar och
känna till vanliga förfaranden för att förebygga olyckor. Använd det nummer som finns i slutet av
varje varning för att hitta dess översättning i de översatta säkerhetsvarningar som medföljer denna
anordning.
SPARA DESSA ANVISNINGAR
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
xi
Page 12
xii
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 13
Aviso
Advarsel
INSTRUÇÕES IMPORTANTES DE SEGURANÇA
Este símbolo de aviso significa perigo. Você se encontra em uma situação em que há risco de lesões
corporais. Antes de trabalhar com qualquer equipamento, esteja ciente dos riscos que envolvem os
circuitos elétricos e familiarize-se com as práticas padrão de prevenção de acidentes. Use o
número da declaração fornecido ao final de cada aviso para localizar sua tradução nos avisos de
segurança traduzidos que acompanham o dispositivo.
GUARDE ESTAS INSTRUÇÕES
VIGTIGE SIKKERHEDSANVISNINGER
Dette advarselssymbol betyder fare. Du befinder dig i en situation med risiko for
legemesbeskadigelse. Før du begynder arbejde på udstyr, skal du være opmærksom på de
involverede risici, der er ved elektriske kredsløb, og du skal sætte dig ind i standardprocedurer til
undgåelse af ulykker. Brug erklæringsnummeret efter hver advarsel for at finde oversættelsen i de
oversatte advarsler, der fulgte med denne enhed.
GEM DISSE ANVISNINGER
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
xiii
Page 14
xiv
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 15
Related Documentation
The documentation set for the Cisco Unified Computing System (UCS) C-Series rack-mount servers is
described in the roadmap document at the following link:
Cisco UCS C-Series Documentation Roadmap
Documentation Feedback
To provide technical feedback on this document, or to report an error or omission, please send your
comments to ucs-docfeedback@external.cisco.com. We appreciate your feedback.
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a
service request, and gathering additional information, see What’s New in Cisco Product Documenta tion
at: http://www.cisco.com/c/en/us/td/docs/general/whatsnew/whatsnew.html.
Subscribe to What’s New in Cisco Product Documentation, which lists all new and revised
Cisco technical documentation, as an RSS feed and deliver content directly to your desktop using a
reader application. The RSS feeds are a free service.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
xv
Page 16
xvi
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 17
Overview
This chapter provides an overview of the Cisco UCS C240 M4 server features:
• External Features Overview, page 1-1
• Replaceable Component Locations, page 1-7
• Summary of Server Features, page 1-8
External Features Overview
The figures in this chapter show an overview of external server features.
The server is orderable in four different versions, each with one of four different front panel/drive
backplane configurations:
• Cisco UCS C240 M4—Small form-factor (SFF) drives with 24-drive backplane and expander.
This version holds up to 24 2.5-inch hard drives or solid state drives. See Figure 1-1.
CHA PTER
1
• Cisco UCS C240 M4—SFF drives, with 16-drive backplane and integrated expander.
This version holds up to 16 2.5-inch hard drives or solid state drives. See Figure 1-2.
• Cisco UCS C240 M4—SFF drives, with 8-drive direct-connect backplane and no expander.
This version holds up to 8 2.5-inch hard drives or solid state drives. See Figure 1-3.
• Cisco UCS C240 M4—Large form-factor (LFF) drives, with 12-drive backplane and integrated
expander. This version holds up to 12 3.5-inch hard drives. See Figure 1-4.
• The rear panel features are the same for all four versions of the server. See Figure 1-5.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
1-1
Page 18
Chapter 1 Overview
Figure 1-1 shows the front panel features of the SFF drives, 24-drive version of the server. This version
of the server has a 24-drive backplane and an integrated expander.
Figure 1-1Cisco UCS C240 M4 Server (SFF Drives, 24-Drive) Front Panel Features
1
2
HDD01
HDD03
HDD04
HDD05
HDD02
HDD06
HDD07
HDD08
HDD09
HDD12
HDD14
HDD15
HDD16
HDD18
HDD19
HDD20
HDD22
HDD23
HDD10
HDD11
HDD13
HDD17
HDD21
HDD24
352943
3
4
5
6
7
8
9
1Drive bays 1–24 (up to 24 2.5-inch drives)7Temperature status LED
2Operations panel buttons and LEDs8Power supply status LED
3Power button/LED9Network link activity LED
4Unit Identification button/LED10 Pull-out asset tag
5System status LED11 KVM connector
(used with KVM cable that provides two
USB 2.0, one VGA, and one serial
connector)
6Fan status LED
10
11
1-2
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 19
Chapter 1 Overview
Figure 1-2 shows the front-panel features of the SFF driv es, 16- drive version of the server. This version
of the server has a 16-drive backplane and an integrated expander.
Figure 1-2Cisco UCS C240 M4 Server (SFF Drives, 16-Drive) Front Panel Features
32468
975
HDD01
1
HDD03
HDD05
HDD07
HDD02
HDD04
HDD06
HDD08
HDD09
HDD11
HDD13
HDD15
HDD10
HDD12
HDD14
HDD16
10
11
352944
1Drive bays 1–16 (up to 16 2.5-inch drives)7Temperature status LED
2Operations panel buttons and LEDs8Power supply status LED
3Power button/LED9Network link activity LED
4Unit Identification button/LED10 KVM connector
(used with KVM cable that provides two
USB 2.0, one VGA, and one serial
connector)
5System status LED11 Pull-out asset tag
6Fan status LED
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
1-3
Page 20
Chapter 1 Overview
Figure 1-3 shows the front-panel features of the SFF drives, 8-drive version of the server. This version
of the server has a direct-connect, 8-drive backplane (no expander).
Figure 1-3Cisco UCS C240 M4 Server (SFF Drives, 8-Drive) Front Panel Features
32468
975
HDD01
1
HDD03
HDD05
HDD07
HDD02
HDD04
HDD06
HDD08
10
11
352945
1Drive bays 1–16 (up to 16 2.5-inch drives)7Temperature status LED
2Operations panel buttons and LEDs8Power supply status LED
3Power button/LED9Network link activity LED
4Unit Identification button/LED10 KVM connector
(used with KVM cable that provides two
USB 2.0, one VGA, and one serial
connector)
5System status LED11 Pull-out asset tag
6Fan status LED
1-4
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 21
Chapter 1 Overview
Figure 1-4 shows the front panel features of the LFF drives, 12-drive version of the server. This version
of the server has a 12-drive backplane with an integrated expander.
Figure 1-4Cisco UCS C240 M4 Server (LFF Drives, 12-Drive) Front Panel Features
1
2
HDD 01
HDD 05
HDD 09
HDD 02
HDD 06
HDD 10
HDD 03
HDD 07
HDD 11
HDD 04
HDD 08
HDD 12
3
4
5
6
7
8
9
1Drive bays 1–16 (up to 16 2.5-inch drives)7Temperature status LED
2Operations panel buttons and LEDs8Power supply status LED
3Power button/LED9Network link activity LED
4Unit Identification button/LED10 Pull-out asset tag
5System status LED11 KVM connector
(used with KVM cable that provides two
USB 2.0, one VGA, and one serial
connector)
6Fan status LED
352946
10
11
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
1-5
Page 22
Chapter 1 Overview
352947
PCIe 01
PCIe 03
PCIe 02
mLOM
PCIe 04
PCIe 06
PCIe 05
PSU 01
PSU 02
4
567910
11
12
3
8
Figure 1-5 shows the rear panel features of the server (identical for all versions of the server).
Figure 1-5Cisco UCS C240 M4 Server Rear Panel Features
1PC Ie rise r 1 (slot s 1, 2, 3*)
7Serial port (RJ-45 connector)
*Slot 3 not present in all versions. See
Replacing a PCIe Card, page 3-43 for riser
options and slot specifications.
2PC Ie rise r 2 (slot s 4, 5, 6)8Dual 1-Gb Ethernet ports (LAN1, LAN2)
3Power supplies (DC power supplies shown)
9VGA video port (DB-15 connector)
See Power Specifications, page A-2 for
specifications and options.
4Modular LAN-on-motherboard (mLOM)
10 Rear Unit Identification button/LED
card slot
5USB 3.0 ports (two)11 Grounding-lug holes (for DC power supplies)
61-Gb dedicated management port
1-6
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 23
Chapter 1 Overview
Replaceable Component Locations
Figure 1-6 shows the locations of the field-replaceable components. The view shown is from the top
down with the top covers and air baffle removed.
Figure 1-6Replaceable Component Locations
3
2
FAN 06
FAN 05
FAN 0 4
1
FAN 03
FAN 02
FAN 01
1 Drives (SAS/SATA drives are hot-swappable
and accessed through the front panel)
4
CPU 2
CPU 1
17
5
6
SD2
SD1
Riser 2
Riser 1
16
1415
10 PCIe riser 1 (PCIe slots 1, 2, 3*)
*Slot 3 not present in all versions. See
13
7
8
9
10
11
12
Replacing a PCIe Card, page 3-43 for riser
options and slot specifications.
2 Fan modules (six, hot-swappable)11 SATA boot drives (two sockets available only
on PCIe riser 1 option 1C)
3 DIMM sockets on motherboard (up to 24
DIMMs)
12 mLOM card socket on motherboard under
PCIe riser 1
4 CPUs and heatsinks (two)13 Socket for embedded RAID interposer board
5 Cisco SD card slots on motherboard (two)14 Cisco modular RAID controller PCIe slot
(dedicated slot and bracket)
6 USB 3.0 slot on motherboard15 RTC battery on motherboard
7 Power supplies (hot-swappable, accessed
16 Embedded RAID header for RAID 5 key
through rear panel)
8 Trusted platform module (TPM) socket on
motherboard, under PCIe riser 2
17 Supercap power module (RAID backup)
mounting location on air baffle (not shown)
9 PCIe riser 2 (PCIe slots 4, 5, 6)
352948
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
1-7
Page 24
Summary of Server Features
Table 1-1 lists a summary of server features.
.
Table 1-1Cisco UCS C240 M4 Server Features
ChassisTwo ra ck-unit (2RU) chassis.
ProcessorsUp to two Intel Xeon E5-2600 v3 Series processors.
Memory24 DDR4 DIMM
Multi-bit error
Multi-bit error protection is supported.
protection
Baseboard
management
BMC, running Cisco Integrated Management Controller (Cisco IMC) firmware.
Depending on your Cisco IMC settings, Cisco IMC can be accessed through the
1-Gb dedicated management port, the 1-Gb Ethernet LOM ports, or a Cisco virtual
interface card.
Network and
The server provides these connectors:
management I/O
Modular I/OA dedicated socket can be used to add an mLOM card for additional rear-panel
connectivity (up to four 1-Gb or 10-Gb Ethernet ports).
WoL1-Gb BASE-T Ethernet LAN ports support the wake-on-LAN (WoL) standard.
PowerTwo power supplies:
Chapter 1 Overview
1
sockets on the motherboard (12 each CPU).
• One 1-Gb Ethernet dedicated management port
• Two 1-Gb BASE-T Ethernet LAN ports
• One RS-232 serial port (RJ-45 connector)
• One 15-pin VGA
• Two U SB
• One front-panel KVM connector that is used with the KVM cable, which
3
provides two USB 2.0, one VGA, and one serial (DB-9) connector.
• AC power supplies optionally 650 W AC, 1200 W AC, or 1400 W AC each.
2
connector
3.0 connectors
1-8
• DC power supplies 930 W DC each.
Do not mix power supply types or wattages in the server.
Redundant as 1+1. See also Power Specifications, page A-2.
ACPIThe advanced configuration and power interface (ACPI) 4.0 standard is supported.
CoolingSix hot-swappable fan modules for front-to-rear cooling.
PCIe I/OUp to six horizontal PCIe
Riser 1 can be ordered as one of three different versions:
• With slots 1, 2, and 3.
• With slots 1 and 2, and a blank slot to accommodate GPU card width.
• With slots 1 and 2, plus two connectors for SATA boot drives.
Riser 2 contains slots 4, 5, and 6.
See Replacing a PCIe Card, page 3-43 for specifications of the slots.
InfiniBandThe InfiniBand architecture is supported by the bus slots.
Cisco UCS C240 M4 Server Installation and Service Guide
4
expansion slots on two risers.
OL-32474-01
Page 25
Chapter 1 Overview
Table 1-1Cisco UCS C240 M4 Server Features (continued)
StorageDrives are installed into front-panel drive bays that provide hot-swappable access
for SAS/SATA drives. The server is orderable in four different versions, each with
one of four different front panel/backplane configurations
• Cisco UCS C240 M4—Small form-factor (SFF) drives with 24-drive
backplane and expander. This version holds up to 24 2.5-inch hard drives or
solid state drives.
• Cisco UCS C240 M4—SFF drives with 16-drive backplane and integrated
expander . This v ersion holds up to 16 2 .5-inch hard dri v es or solid stat e dri ves.
• Cisco UCS C240 M4—SFF drives with 8-drive direct-connect backplane and
no expander. This version holds up to 8 2.5-inch hard drives or solid state
drives.
• Cisco UCS C240 M4—Large form-factor (LFF) drives with 12-drive
backplane and integrated expander. This version holds up to 12 3.5-inch hard
drives.
Note You cannot change the backplane type after-factory. To change a front
panel/backplane configuration, a chassis replacement is required.
Internal USBOne internal USB 3.0 port on the motherboard that you can use with a USB thumb
drive for additional storage.
SD cardsTwo internal bays on the motherboard for up to two SD cards.
The two flash drives can be configured in a RAID 1 configuration.
Disk
Management
(RAID)
Dedicated internal socket for a PCIe-style RAID controller card.
The server can optionally use its own embedded SATA RAID controller with the
installation of a SATA interposer board. You can optionally add a RAID 5 key to
upgrade this SATA RAID.
For a list of RAID
5
controller options and required cabling, see RAID Controller
Considerations, page C-1.
RAID BackupMounting point on the air baffle for the supercap power module that is used with
the Cisco modular RAID controller card.
VideoVGA video resolution up to 1920 x 1200, 16 bpp at 60 Hz, and up to 256 MB of
Cisco UCS C240 M4 Server Installation and Service Guide
1-9
Page 26
Chapter 1 Overview
1-10
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 27
CHA PTER
2
Installing the Server
This chapter describes how to install the server, and it includes the following sections:
• Unpacking and Inspecting the Server, page 2-2
• Preparing for Server Installation, page 2-3
• Installing the Server In a Rack, page 2-5
• Initial Server Setup, page 2-10
• NIC Modes and NIC Redundancy Settings, page 2-14
• System BIOS and Cisco IMC Firmware, page 2-15
• Updating the BIOS and Cisco IMC Firm ware, page 2-15
NoteBefore you install, operate, or service a server, review the Regulatory Compliance and Safety
Information for Cisco UCS C-Series Servers for important safety information.
OL-32474-01
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this device.
Statement 1071
Cisco UCS C240 M4 Server Installation and Service Guide
2-1
Page 28
Unpacking and Inspecting the Server
Unpacking and Inspecting the Server
CautionWhen handling internal server components, wear an ESD strap and handl e modules b y the carrier edges
only.
TipKeep the shipping container in case the server requires shipping in the future.
NoteThe chassis is thoroughly inspected before shipment. If any damage occurred during transportation or
any items are missing, contact your customer service representative immediately.
Step 1Remove the server from its cardboard container and save all packaging material.
Step 2Compare the shipment to the equipment list provided by your customer service representative. Verify
that you have all items.
Step 3Check for damage and report any discrepancies or damage to your customer service repr esentativ e. Have
the following information ready:
• Invoice number of shipper (see the packing slip)
Chapter 2 Installing the Se rver
• Model and serial number of the damaged uni t
• Description of damage
• Effect of damage on the installation
2-2
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 29
Chapter 2 Installing the Server
Preparing for Server Installation
This section provides information about preparing for server installation, and it includes the following
topics:
• Installation Guidelines, page 2-3
• Rack Requirements, page 2-4
• Equipment Requirements, page 2-4
• Slide Rail Adjustment Range and Cable Management Arm Dimensions, page 2-4
Installation Guidelines
Preparing for Server Installation
Warning
Warning
Warning
Warning
CautionTo ensure proper airflow it is necessary to rack the servers using rail kits. Physically placing the units
To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of: 35° C (95° F).
Statement 1047
The plug-socket combination must be accessible at all times, because it serves as the main
disconnecting device.
Statement 1019
This product relies on the building’ s installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than: 250 V, 15 A.
Statement 1005
Installation of the equipment must comply with local and national electrical codes.
Statement 1074
on top of one another or “stacking” without the use of the rail kits blocks the air vents on top of the
servers, which could result in overheating, higher fan speeds, and higher power consumption. We
recommend that you mount your servers on rail kits when you are installing them into the rack because
these rails provide the minimal spacing required between the servers. No additional spacing between the
servers is required when you mount the units using rail kits.
OL-32474-01
CautionAvoid UPS types that use ferroresonant technology. These UPS types can become unstable with systems
such as the Cisco UCS, which can have substantial current draw fluctuations from fluct uating data traff ic
patterns.
Cisco UCS C240 M4 Server Installation and Service Guide
2-3
Page 30
Preparing for Server Installation
When you are installing a server, use the following guidelines:
• Plan your site configuration and prepare the site before install ing the server. See the Cisco UCS Site
Preparation Guide for the recommended site planning tasks.
• Ensure that there is adequate space around the server to allow for servicing the server and for
adequate airflow. The airflow in this server is from front to back.
• Ensure that the air-conditioning meets the thermal requirements listed in the Server Specifications,
page A-1.
• Ensure that the cabinet or rack meets the requirements li sted in the “Rack Requirements” section on
page 2-4.
• Ensure that the site power meets the power requirements listed in the Server Specifications,
page A-1. If available, you can use an uninterruptible power supply (UPS) to protect against power
failures.
Rack Requirements
This section provides the requirements for the standard open racks.
The rack must be of the following type:
• A standard 19-in. (48.3-cm) wide, four -post EIA rack, with mou nting p osts that con form t o English
universal hole spacing, per section 1 of ANSI/EIA-310-D-1992.
Chapter 2 Installing the Se rver
• The rack post holes can be square 0.38-inch (9.6 mm), round 0.28-inch (7.1 mm), #12-24 UNC, or
#10-32 UNC when you use the supplied slide rails.
• The minimum vertical rack space per server must be two RUs, equal to 3.5 in. (88.9 mm).
Equipment Requirements
The slide rails supplied by Cisco Systems for this server do not require tools for installati on if you install
them in a rack that has square 0.38-inch (9.6 mm), round 0.28-inch (7.1 mm), or #12-24 UNC threaded
holes.
Supported Slide Rail Kits
This server supports one rail kit option: Cisco part UCSC-RAILB-M4= (ball-bearing rail kit).
Do not attempt to use a rail kit that was for the Cisco UCS C240 M3 server; the rail kit for the Cisco
UCS C240 M4 server has been designed specifically for i t.
Slide Rail Adjustment Range and Cable Management Arm Dimensions
The slide rails for this server have an adjustment range of 26 to 36 inches (660 to 914 mm).
The optional cable management arm (CMA) adds additional length requirements:
• The additional distance from the rear of the server to the rear of th e C MA is 5.4 inches (137.4 mm)
2-4
• The total length of the server including the CMA is 34.4 inches (874 mm).
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 31
Chapter 2 Installing the Server
353365
1
2
Installing the Server In a Rack
This section contains the following sections:
• Installing the Slide Rails, page 2-5
• Installing the Cable Management Arm (Optional), page 2-8
• Reversing the Cable Management Arm (Optional), page 2-9
Installing the Slide Rails
This section describes how to install the server in a rack using the rack kits that are sold by Cisco.
Installing the Server In a Rack
Warning
Step 1Attach the inner rails to the sides of the server:
To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provid ed to ensure
your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component
at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.
Statement 1006
a. Align an inner rail with one side of the server so that the three keyed slots in the rail align with the
three pegs on the side of the server (see Figure 2-1).
b. Set the keyed slots over the pegs, and then slide the rail toward the front to lock it in place on the
pegs. The front slot has a metal clip that locks ove r the front peg.
c. Install the second inner rail to the opposite side of the server.
Figure 2-1Attaching Inner Rail to Side of Server
1Front of server2Locking clip on inner rail
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
2-5
Page 32
Installing the Server In a Rack
1
2
3
Step 2Open the front securing plate on both slide-rail assemblies. The front end of the slide-rail assembly has
a spring-loaded securing plate that must be open before you can insert the mounting pegs into the
rack-post holes (see Figure 2-2).
On the outside of the assembly, push the green arrow button toward the rear to open the securing plate.
Figure 2-2Front Securing Mechanism, Inside of Front End
Chapter 2 Installing the Se rver
Step 3
1Front mounting pegs3Securing plate shown pulled back to open
position
2Rack post
Install the slide rails into the rack:
a. Align one slide-rail assembly front end with the front rack-post holes that you want to use.
The slide rail front-end wraps around the outside of the rack post and the mounting pegs enter the
rack-post holes from the outside-front (see Figure 2-2).
NoteThe rack post must be between the mounting pegs and the open securing plate.
b. Push the mounting pegs into the rack-post holes from the outside-front.
c. Press the securing plate release button, marked “PUSH.” The spring-loaded securing plate closes to
lock the pegs in place.
d. Adjust the slide-rail length, and then push the rear mounting pegs into the corresponding rear
rack-post holes. The slide rail must be level front-to-rear.
The rear mounting pegs enter the rear rack-post holes from the inside of the rack post.
e. Attach the second slide-rail assembly to the opposite side of the rack. Ensure that the two slide-rail
assemblies are at the same height with each other and are level front-to-back.
f. Pull the inner slide rails on each assembly out toward the rack front until they hit the internal stops
and lock in place.
2-6
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 33
Chapter 2 Installing the Server
Step 4Insert the server into the slide rails:
CautionThis server can weigh up to 67 pounds (59 kilograms) when fully loaded with components. We
recommend that you use a minimum of two people or a mechanical lift when lifting the server.
Attempting this procedure alone could result in personal injury or equipment damage.
a. Align the rear of the inner rails that are attached to the server sides with the front ends of the empty
b. Push the inner rails into the slide rails on the rack until they stop at the internal stops.
c. Slide the release clip toward the rear on both inner rails (Figure 2-3), and then continue pushing t he
Figure 2-3Inner Rail Release Clip
Installing the Server In a Rack
slide rails on the rack.
server into the rack until its front slam latches engage with the rack posts.
123
1Inner rail release clip3Ou ter rail attached to rack post
2Inner rail attached to server
Step 5(Optional) Secure the server in the rack more permanently by using the two screws that are provided with
the slide rails. Perform this step if you plan to move the rack with servers installed.
With the server fully p ushed into the slid e rails, open a hinged slam latch lever on the front of the server
and insert the screw through the hole th at is under the lever. The screw threads into the static part of the
rail on the rack post and prevents the server from being pulled out. Repeat for the opposite slam latch.
353366
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
2-7
Page 34
Installing the Server In a Rack
352584
1
4
2
3
Chapter 2 Installing the Se rver
Installing the Cable Management Arm (Optional)
NoteThe CMA is reversible left to right. To reverse the CMA, see Reversing the Cable Management
Arm (Optional), page 2-9 before installation.
Step 1With the server pushed fully into the rack, slide the CMA tab of the CMA arm that is farthest from the
server onto the end of the station ary sl ide r ail that is attached to the rack po st ( see Figure 2-4). Slide the
tab over the end of the rail until it clicks and locks.
Step 2Slide the CMA tab that is closest to the server over the end of the inner rail that is attached to the server
(see Figure 2-4). Slide the tab over the end of the rail until it clicks and locks.
Step 3Pull out the width-adjustment slider that is at the opposite end of the CMA assembly until it matches the
width of your rack (see Figure 2-4).
Step 4Slide the CMA tab that is at the end of the width-adjustment slider onto the end of the stationary slide
rail that is attached to the rack post (see Figure 2-4). Slide the tab over the end of the rail until it clicks
and locks.
Step 5Open the hinged flap at the top of each plastic cable guide and route your cables through the cable guides
as desired.
Figure 2-4Attaching the Cable Management Arm to the Rear of the Slide Rails
1CMA tab on arm farthest from server and end
of stationary outer slide rail
Cisco UCS C240 M4 Server Installation and Service Guide
2CMA tab on arm closest to the server and end
of inner slide rail attached to server
2-8
3CMA tab on width-adjustment slider and end
of stationary outer slide rail
4Rear of server
OL-32474-01
Page 35
Chapter 2 Installing the Server
Installing the Server In a Rack
Reversing the Cable Management Arm (Optional)
Step 1Rotate the entire CMA assembly 180 degrees. The plastic cable guides must remain pointing upward.
Step 2Flip the tabs at the end of each CMA arm so that they point toward the rear of the server.
Step 3Pivot the tab that is at the end of the width-adjustment slider. Depress and hold the metal button on the
outside of the tab and pivot the tab 180 degrees so that it points toward the rear of the server.
Figure 2-5Reversing the CMA
PUSH
352585
12
1CMA tab on end of width-adjustment slider2Metal button for rotating
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
2-9
Page 36
Initial Server Setup
Initial Server Setup
Connecting and Powering On the Server (Standalone Mode)
NoteThis section describes how to power on the server, assign an IP address, and connect to server
management when using the server in standalone mode. To use the server in UCS integration, specific
cabling and settings are required. See Installation for Cisco UCS Manager Integration, page D-1.
The server is shipped with these default settings:
• The NIC mode is Shared LOM EXT.
Shared LOM EXT mode enables the 1-Gb Ethernet ports and the ports on an y installed Cisco virtual
interface card (VIC) to access Cisco Integrated Management Interface (Cisco IMC). If you want to
use the 10/100/1000 dedicated management ports to access Cisco IMC, you can connect to the server
and change the NIC mode as described in Step 1 of the following procedure.
• The NIC redundancy is active-active. All Ethernet ports are utilized simultaneously.
• DHCP is enabled.
• IPv4 is enabled. You can change this to IPv6.
Chapter 2 Installing the Se rver
There are two methods for connecting to the system for initial setup:
• Local setup—Use this procedure if you want to connect a keyboard and monitor to the system for
setup. This procedure requires a KVM cable (Cisco PID N20-BKVM). See Local Connection
Procedure, page 2-10.
• Remote setup—Use this procedure if you want to perform setup through your dedicated
management LAN. See Remote Connection Procedure, page 2-11.
NoteTo configure the system remotely, you must have a DHCP server on the same network as the
system. Your DHCP server must be preconfigured with the range of MAC addresses for this
server node. The MAC address is printed on a label that is on the pull-out asset tag on the front
panel (see Figure 1-1 through Figure 1-4). This server node has a range of six MAC addresses
assigned to the Cisco IMC. The MAC address printed on the label is the beginning of the range
of six contiguous MAC addresses.
Local Connection Procedure
Step 1Attach a power cord to each power supply in your server, and then attach each power cord to a grounded
AC power outlet. See Power Specifications, page A-2 for power specifications.
Wait for approximately two minutes to let the server boot in standby power during the first bootup.
You can verify system power status by looking at the system Power Status LED on the front pa nel (se e
External Features Overview, page 1-1). The system is in standby power mode when the LED is amber.
Step 2Connect a USB keyboard and VGA monitor to the server using one of the following methods:
• Connect a USB keyboard and VGA monitor to the corresponding connectors on the rear panel (see
External Features Overview, page 1-1).
2-10
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 37
Chapter 2 Installing the Server
• Connect an optional KVM cable (Cisco PID N20-BKVM) to the KVM connector on the front panel
(see External Features Overview, page 1-1 for the connector location). Connect your USB keyboard
and VGA monitor to the KVM cable.
Step 3Open the Cisco IMC Configuration Utility:
a. Press and hold the front panel power button for four seconds to boot the server.
b. During bootup, press F8 when prompted to op en the Cisco IMC Configuration Utility.
This utility has two windows that you can switch between by pressing F1 or F2.
Step 1Attach a power cord to each power supply in your serv er, and then attach each power cord to a grounded
AC power outlet. See Power Specifications, page A-2 for power specifications.
Wait for approximately two minutes to let the server boot in standby power during the first bootup.
You can verify system power status by looking at the system Power Status LED on the front pa nel (se e
External Features Overview, page 1-1). The system is in standby power mode when the LED is amber.
Step 2Plug your management Ethernet cable into the dedicated management port on the rear panel (see
External Features Overview, page 1-1).
Initial Server Setup
Step 3Allow your preconfigured DHCP server to assign an IP address to the server node.
Step 4Use the assigned IP address to access and log in to the Cisco IMC for the server node. Consult with your
DHCP server administrator to determine the IP address.
NoteThe default user name for the server is admin. The default password is password.
Step 5From the Cisco IMC Server Summary page, click Launch KVM Console. A separate KVM console
window opens.
Step 6From the Cisco IMC Summary page, click Power Cycle Server. The system reboots.
Step 7Select the KVM console window.
NoteThe KVM console window must be the active window for the following keyboard actions to
work.
Step 8When prompted, press F8 to enter the Cisco IMC Configurati on Utility. This utility opens in the KVM
console window.
This utility has two windows that you can switch between by pressing F1 or F2.
Cisco UCS C240 M4 Server Installation and Service Guide
2-11
Page 38
Initial Server Setup
Cisco IMC Configuration Utility Setup
The following procedure is performed after you connect to the system and open the Cisco IMC
Configuration Utility.
Step 1Set NIC mode and NIC redundancy:
a. Set the NIC mode to choose wh ich ports to u se to access Cisco IMC for server management (see
Figure 1-5 for identification of the ports):
• Shared LOM EXT (default)—This is the shared LOM extended mode, the factory-default setting.
With this mode, the shared LOM and Cisco Card interfaces are both enabled.
In this mode, DHCP replies are returned to both the shared LOM ports and the Cisco card ports. If
the system determines that the Cisco card connection is not getting its IP address from a Cisco UCS
Manager system because the server is in standalone mode, further DHCP requests from the Cisco
card are disabled. Use the Cisco Card NIC mode if you want to connect to Cisco IMC through a
Cisco card in standalone mode.
• Dedicated—The dedicated management port is used to access Cisco IMC. You must select a NIC
redundancy and IP setting.
• Shared LOM—The 1-Gb Ethernet ports are used to access Cisco IMC. You must select a NIC
redundancy and IP setting.
• Cisco Card—The ports on an installed Cisco UCS virtual interface card (VIC) are used to access
Cisco IMC. You must select a NIC redundancy and IP setting.
Chapter 2 Installing the Se rver
See also the required VIC Slot setting below.
• VIC Slot—If you use the Cisco Card NIC mode, you must select this setting to match where your
VIC is installed. The choices are Riser1, Riser2, or Flex-LOM (the mLOM slot).
–
If you select Riser1, slot 2 is the primary slot, but you can use slot 1.
–
If you select Riser2, slot 5 is the primary slot, but you can use slot 4.
–
If you select Flex-LOM, you must use an mLOM -style VIC in th e mLOM s lot.
b. Use this utility to change the NIC redundancy to your preference. This server has three possible NIC
redundancy settings:
–
None—The Ethernet ports operate independently and do not fail o ver if there is a problem. Th is
setting can be used only with the Dedicated NIC mode.
–
Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
–
Active-active—All Ethernet ports are utilized simultaneously. Shared LOM EXT mode can
have only this NIC redundancy setting. Shared LOM and Cisco Card modes can have both
Active-standby and Active-active settings.
Step 2Choose whether to enable DHCP for dynamic network settings, or to enter static network settings.
NoteBefore you enable DHCP, you must preconfigure your DHCP server with the range of MAC
addresses for this server. The MAC address is printe d on a labe l on the rear of the se rver. This
server has a range of six MAC addresses assigned to Cisco IMC. The MAC address printed on
the label is the beginning of the range of six contiguous MAC addresses.
2-12
The static IPv4 and IPv6 settings include the following:
• The Cisco IMC IP address.
• The prefix/subnet.
For IPv6, valid values are 1–127.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 39
Chapter 2 Installing the Server
• The gateway.
• The preferred DNS server address.
Step 3(Optional) Use this utility to make VLAN settings.
Step 4Press F1 to go to the second settings window, then continue with the next step.
From the second window, you can press F2 to switch back to the first window.
Step 5(Optional) Set a hostname f or the se rver.
Step 6(Optional) Enable dynamic DNS and set a dynamic DNS (DDNS) domain.
Step 7(Optional) If you check the Factory Default check box, the server reverts to the factory defaults.
Step 8(Optional) Set a default user password.
Step 9(Optional) Enable auto-negotiation of port settings or set the port speed and duplex mode manually.
NoteAuto-negotiation is applicable only when you use the Dedicated NIC mode. Auto-negotiation
Initial Server Setup
For IPv6, if you do not know the gateway, you can set it as none by entering :: (two colons).
For IPv6, you can set this as none by entering :: (two colons).
sets the port speed and duplex mode automatically based on the switch port to which the server
is connected. If you disable auto-negotiation, you must set the port speed and duplex mode
manually.
Step 10(Optional) Reset port profiles and the port name .
Step 11Press F5 to refresh the settings that you made. You might have to wait about 45 seconds until the new
settings appear and the message, “Network settings configured” is displayed before you reboot the server
in the next step.
Step 12Press F10 to save your settings and reboot the server.
NoteIf you chose to enable DHCP, the dynamically assigned IP and MAC add resses are displayed on
the console screen during bootup.
Use a browser and the IP address of the Cisco IMC to connect to the Cisco IMC management interface.
The IP address is based upon the settings that you made (either a static address or the address assigned
by your DHCP server).
NoteThe default username for the server is admin. The default password is password.
T o manage the s erver, see the Cisco UCS C-Series Rack-Mount Server Configuration Guid e or the Cisco UCS C-Series Rack-Mount Server CLI Configuration Guide for instructions on using those interfaces.
The links to these documents are in the C-Series documentation roadmap:
Cisco UCS C240 M4 Server Installation and Service Guide
2-13
Page 40
NIC Modes and NIC Redundancy Settings
NIC Modes and NIC Redundancy Settings
NIC Modes
This server has the following NIC mode settings that you can choose from:
• Shared LOM EXT (default)—This mode is the shared LOM extended mode that is the
factory-default setting. W ith this mode, the shared LOM and Cisco Card interfaces are both enabled.
In this mode, DHCP replies are returned to both the shared LOM ports and the Cisco card ports. If
the system determines that the Cisco card connection is not getting its IP address from a Cisco UCS
Manager system because the server is in standalone mode, further DHCP requests from the Cisco
card are disabled. If the system determines that the Cisco card connection is getting its IP address
from a Cisco UCS Manager syst em , the reply has parameters that automatically move the server to
UCSM mode.
• Dedicated—The dedicated management port is used to access Cisco IMC. You must select a NIC
redundancy and IP setting.
• Shared LOM—The 1-Gb Ethernet ports are used to access Cisco IMC. You must select a NIC
redundancy and IP setting.
• Cisco Card—The ports on an installed Cisco UCS virtual interface card (VIC) are used to access
Cisco IMC. You must select a NIC redundancy and IP setting.
See also the required VIC Slot setting below.
Chapter 2 Installing the Se rver
• VIC Slot—If you use the Cisco Card NIC mode, you select this setti ng to match where your VIC is
NIC Redundancy
This server has the following NIC redundancy settings that you can choose from:
installed. The choices are Riser1, Riser2, or Flex-LOM (the mLOM slot).
–
If you select Riser1, slot 2 is the primary slot, but you can also use slot 1.
–
If you select Riser2, slot 5 is the primary slot, but you can also use slot 4.
–
If you select Flex-LOM, you must use an mLOM -style VIC in th e mLOM s lot.
–
None—The Ethernet ports operate independently and do not fail o ver if there is a problem. Th is
setting can be used only with the Dedicated NIC mode.
–
Active-standby—If an active Ethernet port fails, traffic fails over to a standby port.
–
Active-active—All Ethernet ports are utilized simultaneously. Shared LOM EXT mode can
have only this NIC redundancy setting. Shared LOM and Cisco Card modes can have both
Active-standby and Active-active settings.
The active/activ e setting uses Mode 5 or Balance-TLB (adaptive transmit load balancing). This
is channel bonding that does not require any special switch support. The outgoing traffic is
distributed according to the current load (computed relative to the speed) on each slave.
Incoming traffic is recei v ed by the current sla v e. If the recei ving sla v e f ails, another sla v e takes
over the MAC address of the failed receiving slave.
2-14
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 41
Chapter 2 Installing the Server
System BIOS and Cisco IMC Firmware
This section includes information about the system BIOS and it includes the following sections:
• Updating the BIOS and Cisco IMC Firm ware, page 2-15
• Accessing the System BIOS, page 2-16
Updating the BIOS and Cisco IMC Firmware
CautionWhen you upgrade the BIOS firmware, you must also upgrade Cisco IMC firmware to the same ve rsion
or the server will not boot. Do not power on the server until the BIOS and Cisco IMC firmware are
matching or the server does not boot.
Cisco provides the Cisco Host Upgrade Utility to assist with simu ltaneously upgradi ng the BIOS, Cisco
IMC, and other firmware to compatible levels.
System BIOS and Cisco IMC Firmware
The server uses firmware obtained from and certified by Cisco. Cisco provides release notes with each
firmware image. There are several methods for updating the firmware:
• Recommended method for system components firmware update: Use the Cisco Host Upgrade
Utility to simultaneously upgrade Cisco IMC, BIOS, LOM, LSI storage controller, and Cisco UCS
VIC firmware to compatible levels.
See the Cisco Host Upgrade Utility Quick Reference Guide for your firmware level at the
documentation roadmap link below.
• You can upgrade the BIO S using the EFI in terface, or upgrade from a Windows or Linux platform.
See the Cisco UCS C-Series Rack-Mount Server BIOS Upgrade Guide.
• You can upgrade C isco IMC an d BIOS firmware by us ing the Ci sco IMC GUI in terface.
See the Cisco UCS C-Series Rack-Mount Server Configuration Guide.
• You can upgrade C isco IMC an d BIOS firmware by usin g the Cisco IMC CLI interface.
See the Cisco UCS C-Series Rack-Mount Server CLI Configuration Guide.
For links to the documents listed above, see the documentation roadmap at the following URL:
Cisco UCS C240 M4 Server Installation and Service Guide
2-15
Page 42
System BIOS and Cisco IMC Firmware
Chapter 2 Installing the Se rver
Accessing the System BIOS
You can change the BIOS settings for your server. Detailed instructions are also printed on the BIOS
screens.
Step 1Enter the BIOS setup utility by pressing the F2 key when prompted during bootup.
NoteThe version and build of the current BIOS are displayed on the Main page of the utility.
Step 2Use the arrow keys to select the BIOS menu page.
Step 3Highlight the field to be modified by using the arrow keys.
Step 4Press Enter to select the field that you want to change, and then modify the value in the field.
Step 5Press the right arrow key until the Exit menu screen is displayed.
Step 6Follow the instructions on the Exit menu screen to save your changes and exit the setup utility (or Press
F10). You can exit without saving changes by pressing Esc.
2-16
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 43
CHA PTER
Maintaining the Server
This chapter describes how to diag nose server system problems using LEDs. It also provid es information
about how to install or replace hardware components, and it includes the following sections:
• Server Monitoring and Management Tools, page 3-1
• Status LEDs and Buttons, page 3-2
• Preparing for Server Component Installation, page 3-9
• Installing or Replacing Server Components, page 3-13
• Service DIP Switches, page 3-74
Server Monitoring and Management Tools
3
Cisco Integrated Management Interface
Y ou can monitor the serv er inv entory , health, and system event lo gs by using the built-in Cisco Inte grated
Management Controller (Cisco IMC) GUI or CLI interfaces. See the user documentation for your
firmware release at the following URL:
Cisco UCS C240 M4 Server Installation and Service Guide
3-1
Page 44
Status LEDs and Buttons
Status LEDs and Buttons
This section describes the location and meaning of LEDs and buttons and includes the following topics
• Front Panel LEDs, page 3-2
• Rear Panel LEDs and Buttons, page 3-5
• Internal Diagnostic LEDs, page 3-8
Front Panel LEDs
Figure 3-1 shows the front panel LEDs. Table 3-1 defines the LED states.
The small form factor (SFF) drives, 24-drive version and the SFF drives, 16-drive version are shown.
Chapter 3 Maintaining the Server
Figure 3-1Front Panel LEDs
12
3
4
HDD01
HDD03
HDD04
HDD05
5
HDD02
HDD06
HDD07
HDD08
HDD09
HDD12
HDD14
HDD15
HDD16
HDD18
HDD19
HDD20
HDD22
HDD23
HDD10
HDD11
HDD13
HDD17
HDD21
HDD24
6
7
8
9
3468
975
21
HDD01
HDD03
HDD05
HDD07
HDD02
HDD04
HDD06
HDD08
HDD09
HDD11
HDD13
HDD15
HDD10
HDD12
HDD14
HDD16
352950
3-2
1Hard drive fault LED (on each drive tray)6Fan status LED
2Hard drive activity LED (on each drive tray)7Temperature status LED
3Power button/power status LED8Power supply status LED
4Unit Identification button/LED9Network link activity LED
5System status LED
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 45
Chapter 3 Maintaining the Server
Table 3-1Front Panel LEDs, Definitions of States
LED NameState
1Hard drive fault
Note: If your controller is a Cisco
UCS RAID SAS 9300-8i or
9300-8e HBA, see Cisco UCS
SAS 9300-8e HBA
• Off—The hard drive is operating properly.
• Amber—Drive fault detected.
• Amber, blinking—The device is rebuilding.
• Amber, blinking with one-second interval—Drive locate function activated.
Considerations, page C-4 for
differing LED behavior.
2Hard drive activity
3Power button/LED
• Off—There is no hard drive in the hard drive tray (no access, no fault).
• Green—The hard drive is ready.
• Green, blinking—The hard drive is reading or writing data.
• Off—There is no AC power to the server.
• Amber—The server is in standby power mode. Power is supplied only to the
Cisco IMC and some motherboard functions.
Status LEDs and Buttons
4Unit Identification
5System status
6Fan stat u s
• Green—The server is in main power mode. Power is supplied to all server
components.
• Off—The unit identification function is not in use.
• Blue—The unit identification function is activated.
• Green—The server is running in a normal operating condition.
• Green, blinking—The server is performing system initialization and memory
check.
• Amber, steady—The server is in a degraded operational state. For example:
–
Power supply redundancy is lost.
–
CPUs are mismatched.
–
At least one CPU is faulty.
–
At least one DIMM is faulty.
–
At least one drive in a RAID configuration failed.
• Amber, blinking—The server is in a critical fault state. For example:
–
Boot failed.
–
Fatal CPU and/or bus error is detected.
–
Server is in an over-temperature condition.
• Green—All fan modules are operating properly.
• Amber, steady—One or more fan modules breached the critical threshold.
OL-32474-01
• Amber, blinking—One or more fan modules breached the non-recoverable
threshold.
Cisco UCS C240 M4 Server Installation and Service Guide
3-3
Page 46
Chapter 3 Maintaining the Server
Status LEDs and Buttons
Table 3-1Front Panel LEDs, Definitions of States (continued)
LED NameState
7Temperature status• Green—The server is operating at normal temperature.
• Amber, steady—One or more temperature sensors breached the critical
threshold.
• Amber, blinking—One or more temperature sensors breached the
non-recoverable threshold.
8Power supply status
9Network link activity
• Green—All power supplies are operating normally.
• Amber, st eady—One or more power supplies are in a degraded operational stat e.
• Amber, blinking—One or more power supplies are in a critical fault state.
• Off—The Ethernet link is idle.
• Green—One or more Ethernet LOM ports are link-active, but there is no activity.
• Green, blinking—One or more Ethernet LOM ports are lin k-acti v e, w ith activity.
3-4
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 47
Chapter 3 Maintaining the Server
Rear Panel LEDs and Buttons
Figure 3-2 shows the rear panel LEDs and buttons. Table 3-2 defines the LED states.
Figure 3-2Rear Panel LEDs and Buttons
Status LEDs and Buttons
1
2
PCIe 03
PCIe 02
PCIe 01
mLOM
3685
1Power supply fault LED51-Gb Ethernet dedicated management link
2Power supply AC status LED61-Gb Ethernet link speed LED
3Optional mLOM card LEDs
(not shown, see Table 3-2)
41-Gb Ethernet dedicated management link
speed LED
Table 3-2Rear Panel LEDs, Definitions of States
LED NameState
1Power supply fault
This is a summary; for advanced
power supply LED information,
see Table 3-3.
• Off—The power supply is operating normally.
• Amber, blinking—An event warning threshold has been reached, but the power
supply continues to operate.
• Amber, solid—A critical fault threshold has been reached, causing the power
supply to shut down (for example, a fan failure or an over-temperature
condition).
2Power supply status
AC power supplies:
PCIe 06
PCIe 05
PCIe 04
4
7
PSU 02
PSU 01
352951
status LED
71-Gb Ethernet link status LED
8Un it Identification button/LED
This is a summary; for advanced
power supply LED information,
see Table 3-3.
OL-32474-01
• Off—There is no AC powe r to the power supply.
• Green, blinking—AC power OK; DC output not enabled.
• Green, solid—AC power OK; DC outputs OK.
DC power supplies:
• Off—There is no DC power to the power supply.
• Green, blinking—DC power OK; DC output not enabled.
• Green, solid—DC power OK; DC outputs OK.
Cisco UCS C240 M4 Server Installation and Service Guide
3-5
Page 48
Status LEDs and Buttons
Table 3-2Rear P anel LEDs, Definitions of States (continued)
LED NameState
3Optional mLOM 10-Gb SFP+
(there is a single status LED)
3Optional mLOM 10-Gb BASE-T
link speed
3Optional mLOM 10-Gb BASE-T
link status
41-Gb Ethernet dedica ted
management link speed
51-Gb Ethernet dedica ted
management link status
61-Gb Ethernet link speed
• Off—No link is present.
• Green, steady—Link is active.
• Green, blinking—Traffic is present on the active link.
• Off—Link speed is 10 Mbps.
• Amber—Link speed is 100 Mbps/1 Gbps.
• Green—Link speed is 10 Gbps.
• Off—No link is present.
• Green—Link is active.
• Green, blinking—Traffic is present on the active link.
• Off—Link speed is 10 Mbps.
• Amber—Link speed is 100 Mbps.
• Green—Link speed is 1 Gbps.
• Off—No Link is present.
• Green—Link is active.
• Green, blinking—Traffic is present on the active link.
• Off—Link speed is 10 Mbps.
Chapter 3 Maintaining the Server
71-Gb Ethernet link status
8Unit Identification
• Amber—Link speed is 100 Mbps.
• Green—Link speed is 1 Gbps.
• Off—No link is present.
• Green—Link is active.
• Green, blinking—Traffic is present on the active link.
• Off—The unit identification function is not in use.
• Blue—The unit identification function is activated.
3-6
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 49
Chapter 3 Maintaining the Server
In Table 3-3, read the status and fault LED states together in each row to determine the event that cause
this combination.
Table 3-3Rear Power Supply LED States
Green PSU Status LED State A mber PSU Fault LED State Event
• Solid on• Off12V main on (main power mode)
• Blinking• Off12Vmain off (standby power mode)
• Off• OffNo AC power input (all PSUs present)
• Off• OnNo AC power input (redundant supply active)
• Blinking• Off12V main off (CR slave PSU is in sleep mode)
Status LEDs and Buttons
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-7
Page 50
Status LEDs and Buttons
352952
FAN 0 6
1
2
3
FAN 05
FAN 04
FAN 0 3
FAN 02
FAN 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
465
Internal Diagnostic LEDs
The server is equipped with a supercap voltage source that can activate internal component fault LEDs
up to 30 minutes after AC power is removed. The server has internal fault LEDs for CPUs, DIMMs, fan
modules, SD cards, the RTC battery, and the mLOM card.
To use thes e LED s to identify a failed component, press the front or rear Unit Identification button (see
Figure 3-1orFigure 3-2) with AC power removed. An LED lights amber to in dicate a faulty componen t.
See Figure 3-3 for the locations of these internal LEDs.
Figure 3-3I nternal Diagnostic LED Locations
Chapter 3 Maintaining the Server
3-8
1Fan module fault LEDs (one on each fan
module)
2DIMM fault LEDs (one directly in front of
each DIMM socket on the motherboard)
3CP U fault LEDs6mLO M card faul t LED (un der PCIe riser 1)
Table 3-4Internal Diagnostic LEDs, Definition of States
LED NameState
Internal diagnostic LEDs (all)
Cisco UCS C240 M4 Server Installation and Service Guide
4SD card fault LEDs
5RTC battery fault LED (under PCIe riser 1)
• Off—Component is functioning normally.
• Amber—Component has a fault.
OL-32474-01
Page 51
Chapter 3 Maintaining the Server
Preparing for Server Component Installation
This section describes how to prepare for component installation, and it includes the following topics:
• Required Equipment, page 3-9
• Shutting Down and Powering Off the Server, page 3-9
• Removing and Replacing the Server Top Cover, page 3-10
• Serial Number Location, page 3-12
• Hot-Swap or Hot-Plug Replacement, page 3-12
Required Equipment
The following equipment is used to perform the procedures in this chapter:
• Number 2 Phillips-head screwdriver
• Electrostatic discharge (ESD) strap or other grounding equipment such as a grounded mat
Preparing for Server Component Installation
Shutting Down and Powering Off the Server
The server can run in two power modes:
• Main power mode—Power is supplied to all server components and any operating system on your
drives can run.
• Standby power mode—Power is supplied only to the service processor and the cooling fans and it
is safe to power off the server from this mode.
You can invoke a graceful shutdown or a hard shutdown by using either of the following methods:
• Use the Cisco IMC management interface.
• Use the Power button on the server front panel. To use the Power button, follow these steps:
Step 1Check the color of the Power Status LED (see the “Front Panel LEDs” section on page 3-2).
• Green—The server is in main power mode and must be shut down before it can be safely powered
off. Go to Step 2.
• Amber—The server is already in standby mode and can be safely powered off. Go to Step 3.
Step 2Invoke either a graceful shutdown or a hard shutdown:
CautionTo avoid data loss or damage to your operating system, you should always invoke a graceful shutdown
of the operating system.
OL-32474-01
• Graceful shutdown—Press and release the Power button. The operating system performs a graceful
shutdown and the server goes to standby mode, which is indicated by an amber Power Status LED.
• Emergency shutdown—Press and hold the Power button for 4 seconds to force the main power off
and immediately enter standby mode.
Step 3Disconnect the power cords from the power supplies in your server to completely power off the server.
Cisco UCS C240 M4 Server Installation and Service Guide
3-9
Page 52
Preparing for Server Component Installation
Removing and Replacing the Server Top Cover
Step 1Remove t h e to p c over ( s ee Figure 3-4).
a. If the cover latch is locked, use a screwdriver to turn the lock 90-degrees counterclockwise to unlo ck
it. See Figure 3-4.
b. Lift on the end of the latch that has the green finger grip. The cover is pushed back to the open
position as you lift the latch.
c. Lift the top cover straight up from the server and set it aside.
Step 2Replace the top cover:
NoteThe latch must be in the fully open position when you set the cover back in place, which allows
the opening in the latch to sit over a peg that is on the fan tray.
a. With the latch in the fully open position, place the cover on top of the server about one-half inch
(1.27 cm) behind the lip of the front cover panel. The opening in the latch should fit over the peg
that sticks up from the fan tray.
b. Press the cover latch down to the closed posi tion. The co ver is pushed forwar d to the closed posit ion
as you push down the latch.
c. If desired, lock the latch by using a screwdriver to turn the lock 90-degrees clockwise.
Chapter 3 Maintaining the Server
3-10
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 53
Chapter 3 Maintaining the Server
352953
12
3
Figure 3-4Removing the Top Cover
Preparing for Server Component Installation
1Front cover panel3Locking cover latch
2Top cover
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-11
Page 54
Preparing for Server Component Installation
Serial Number Location
The serial number (SN) for the server is printed on a label on the top of the server, near the front.
Hot-Swap or Hot-Plug Replacement
Some components can be removed and replaced without powering off and removing AC po wer from the
server.
• Hot-swap replacement—You do not have to precondition or shut down the component in the
software before you remove it for the following components:
–
SAS/SATA drives
–
Cooling fan modules
–
Power supplies (when 1+1 redundant)
Chapter 3 Maintaining the Server
3-12
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 55
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Installing or Replacing Server Components
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place.
Statement 1029
CautionWhen handling server components, wear an ESD strap to avoid damage.
TipYou can press the Unit Identification button on the front panel or rear panel to turn on a flashing Unit
Identification LED on the front and rear panels of the serv er . This button allo ws you to locate the specific
server that you are servicing when you go to the opposite side of the rack. You can also activate these
LEDs remotely by using the Cisco IMC interface.See the “Status LEDs and Buttons” section on page 3-2
for locations of these LEDs.
This section describes how to install and replace serv er components, and it includes the follo wing topics:
• Replaceable Component Locations, page 3-14
• Replacing Hard Drives or Solid State Drives, page 3-15
• Replacing Fan Modules, page 3-18
• Replacing DIMMs, page 3-20
• Replacing CPUs and Heatsinks, page 3-24
• Replacing a SATA Interposer Board, page 3-28
• Replacing a Cisco Modular RAID Controller Card, page 3-30
• Replacing the Supercap Power Module (RAID Backup Battery), page 3-34
• Replacing a Software RAID 5 Key Module, page 3-36
• Replacing the Motherboard RTC Battery, page 3-38
• Replacing an Internal SD Card, page 3-39
• Enabling or Disabling the Internal USB Port, page 3-40
• Replacing a PCIe Riser, page 3-41
• Replacing a PCIe Card, page 3-43
• Installing an NVIDIA GPU Card, page 3-52
• Replacing Internal SATA Boot Drives, page 3-64
• Installing a Trusted Platform Module, page 3-66
• Replacing Power Supplies, page 3-69
• Replacing an mLOM Card, page 3-72
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-13
Page 56
Installing or Replacing Server Components
Replaceable Component Locations
Figure 3-5 shows the locations of the components that are supported as field-replace able. The view
shown is from the top down, with the top covers and air baffle removed.
Figure 3-5Replaceable Component Locations
Chapter 3 Maintaining the Server
3
2
FAN 06
FAN 05
FAN 0 4
1
FAN 03
FAN 02
FAN 01
1 Drives (hot-swappable, accessed through fron t
panel)
4
CPU 2
CPU 1
17
5
6
SD2
SD1
Riser 2
Riser 1
16
1415
10 PCIe riser 1 (PCIe slots 1, 2, 3*)
*Slot 3 not present in all versions. See
13
7
8
9
10
11
12
Replacing a PCIe Card, page 3-43 for riser
options and slot specifications.
2 Fan modules (six, hot-swappable)11 SATA boot drives (two sockets, available only
on PCIe riser 1 option 1C)
3 DIMM sockets on motherboard (up to 24
DIMMs)
12 mLOM card socket on motherboard under PCIe
riser 1
4 CPUs and heatsinks (two)13 Socket for embedded RAID interposer board
5 SD card slots on motherboard (two)14 Cisco modular RAID controller PCIe slot
(dedicated slot and bracket)
6 USB 3.0 slot on motherboard15 RTC battery on motherboard
7 Power supplies (hot-swappable, accessed
16 Embedded RAID header for RAID 5 key
through rear panel)
8 Trusted platform module (TPM) socket on
motherboard, under PCIe riser 2
17 Supercap power module (RAID backup)
mounting location on air baffle (not shown)
9 PCIe riser 2 (PCIe slots 4, 5, 6)
352948
3-14
The Technical Specifications Sheets for all versions of this server, which include supported component
part numbers, are at Cisco UCS Servers Technical Specifications Sheets.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 57
Chapter 3 Maintaining the Server
352954
HDD01
HDD02
HDD03
HDD04
HDD05
HDD06
HDD07
HDD08
HDD09
HDD10
HDD11
HDD12
HDD13
HDD14
HDD15
HDD16
HDD17
HDD18
HDD19
HDD20
HDD21
HDD22
HDD23
HDD24
HDD01
HDD03
HDD05
HDD07
HDD02
HDD04
HDD06
HDD08
HDD09
HDD11
HDD13
HDD15
HDD10
HDD12
HDD14
HDD16
352955
Replacing Hard Drives or Solid State Drives
This section includes the following information:
• Drive Population Guidelines, page 3-15
• Drive Replacement Procedure, page 3-16
Drive Population Guidelines
The server is orderable in four different versions, each with one of four different front panel/backplane
configurations:
• Cisco UCS C240 M4—Small form-factor (SFF) drives with 24-drive backplane and expander.
This version holds up to 24 2.5-inch hard drives or solid state drives.
• Cisco UCS C240 M4—SFF drives, with 16-drive backplane and integrated expander.
This version holds up to 16 2.5-inch hard drives or solid state drives.
• Cisco UCS C240 M4—SFF drives, with 8-drive direct-connect backplane and no expander.
This version holds up to 8 2.5-inch hard drives or solid state drives.
Installing or Replacing Server Components
• Cisco UCS C240 M4—Large form-factor (LFF) drives, with 12-drive backplane and integrated
expander. This version holds up to 12 3.5-inch hard drives.
NoteYou cannot change the backplane type after-factory. To change a front panel/backplane configuration, a
chassis replacement is required.
The drive-bay numbering for all server versions is shown in Figure 3-6 through Figure 3-9.
Figure 3-6Drive Numbering, SFF Drive s, 24-Drive Version
Figure 3-7Drive Numbering, SFF Drive s, 16-Drive Version
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-15
Page 58
Installing or Replacing Server Components
HDD01
HDD03
HDD05
HDD07
HDD02
HDD04
HDD06
HDD08
352956
Chapter 3 Maintaining the Server
Figure 3-8Drive Numbering, SFF Drives, 8-Drive Version
Figure 3-9Drive Numbering, LFF Drives, 12-Drive Version
HDD 01
HDD 05
HDD 09
Observe these drive population guidelines for optimal performance:
• When populating drives, add drives in the lowest numbered bays first.
• Keep an empty drive blanking tray in any unused bays to ensure optimal airflow and cooling.
HDD 02
HDD 06
HDD 10
HDD 03
HDD 07
HDD 11
HDD 04
HDD 08
HDD 12
352957
• You can mix hard drives and solid state drives in the same server. However, you cannot configure a
logical volume (virtual drive) that contains a mix of hard drives and SSDs. That is, when you create
a logical volume, it must contain all hard drives or all SSDs.
Drive Replacement Procedure
TipYou do not have to shut down or power off the server to replace SAS/SATA hard drives or solid state
drives (SSDs) because they are hot-swappable.
Step 1Remove the drive that you are replacing or remove a blank drive tray from an empty bay:
a. Press the release button on the face of the drive tray. See Figure 3-10.
b. Grasp and open the ejector lever and then pull the drive tray out of the slot.
c. If you are replacing an existing drive, remove the four drive-tray screws that secure the drive to the
tray and then lift the drive out of the tray.
Step 2Install a new drive:
a. Place a new drive in the empty drive tray and replace the four drive-tray screws.
b. With the ejector lever on the drive tray open, insert the drive tray into the empty drive bay.
c. Push the tray into the slot until it touches the backplane, and then close the ejector lever to lock the
drive in place.
3-16
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 59
Chapter 3 Maintaining the Server
Figure 3-10Replacing Drives
Installing or Replacing Server Components
HDD02
21
HDD03
HDD04
HDD05
3
HDD06
HDD07
3
HDD08
HDD09
HDD12
HDD14
HDD15
HDD16
HDD18
HDD19
HDD20
HDD22
HDD23
HDD10
HDD11
HDD13
3
HDD17
3
HDD21
HDD24
1Release button3Drive tray securing screws (four)
2Ejec tor lever–
352958
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-17
Page 60
Installing or Replacing Server Components
Replacing Fan Modules
The six hot-swappable fan modules in the server ar e numbered as follows when you are facing the front
of the server.
Figure 3-11Fan Module Numbering
FAN 6FAN 5FAN 4FAN 3FAN 2FAN 1
TipA fault LED is on the top of each fan module that lights amber if the fan module fails. To operate these
LEDs from the supercap power source, remove AC power cords and then press the Unit Identification
button. S e e a l s o Internal Diagnostic LEDs, page 3-8.
CautionYou do not have to shut down or power off the server to replace fan modules because they are hot-
swappable. Howe ver , to maintain proper cooling, do not oper ate the server for more than one minute with
any fan module removed.
Chapter 3 Maintaining the Server
Step 1Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 2Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 3Identify a faulty fan module by looking for a fan fault LED that is lit amber (see Figure 3-12).
Step 4Remove a fan module that you are replacing (see Figure 3-12):
a. Grasp the top of the fan and pinch the green plastic latch toward the center.
b. Lift straight up to remove the fan module from the server.
Step 5Install a new fan module:
a. Set the new fan module in place, aligning the connector on the bottom of the fan module with the
connector on the motherboard.
NoteThe arrow label on the top of the fan module, which indicates the direction of airflow, should
point toward the rear of the server.
b. Press down gently on the fan module until the latch clicks and locks in place.
Step 6Replace the top cover.
Step 7Replace the server in the rack.
3-18
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 61
Chapter 3 Maintaining the Server
Figure 3-12Fan Modules Latch and Fault LED
12
Installing or Replacing Server Components
SD2
SD1
FAN 05
FAN 04
FAN 0 3
FAN 02
FAN 01
CPU 2
Riser 2
CPU 1
Riser 1
352959
1Finger latch (on each fan module)2Fan module fault LED (on each fan module)
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-19
Page 62
Installing or Replacing Server Components
Replacing DIMMs
This section includes the following topics:
• Memory Performance Guidelines and Population Rules, page 3-20
• DIMM Replacement Procedure, page 3-23
CautionDIMMs and their sockets are fragile and must be handled with care to avoid damage during installation.
CautionCisco does not support third-party DIMMs. Using non-Cisco DIMMs in the server might result in system
problems or damage to the motherboard.
NoteTo ensure the best server performance, it is important that you are familiar with memory performance
guidelines and population rules before you install or replace the memory.
Chapter 3 Maintaining the Server
Memory Performance Guidelines and Population Rules
This section describes the type of memory that the server requires and its effect on performance. The
section includes the following topics:
• DIMM Socket Numbering, page 3-21
• DIMM Population Rules, page 3-21
• Memory Mirroring and RAS, page 3-22
• Lockstep Channel Mode, page 3 -22
3-20
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 63
Chapter 3 Maintaining the Server
DIMM Socket Numbering
Figure 3-13 shows the numbering of the DIMM sockets and CPUs.
Installing or Replacing Server Components
DIMM Population Rules
Figure 3-13CPUs and DIMM Socket Numbering on Motherboard
CPU 1
B3
G1
G2
G3H1H2
H3
CPU 2
F3F2F1
E3
E2
E1
C1C2C3
D1D2D3
Front of Server
Observe the following guidelines when installing or replacing DIMMs:
• Each CPU supports four memory channels.
–
CPU1 supports channels A, B, C, and D.
–
CPU2 supports channels E, F, G, and H.
• Each channel has three DIMM sockets (for example, channel A = slots A1, A2, and A3).
–
A channel can operate with one, two, or three DIMMs installed.
–
If a channel has only one DIMM, populate slot 1 first (the blue slot).
B2
B1
A3
A2
A1
352815
• When both CPUs are installed, populate the DIMM sockets of each CPU identically.
–
Fill blue #1 slots in the channels first: A1, E1, B1, F1, C1, G1, D1, H1
–
Fill black #2 slots in the channels second: A2, E2, B2, F2, C2, G2, D2, H2
–
Fill white #3 slots in the channels third: A3, E3, B3, F3, C3, G3, D3, H3
• Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized. In a
single-CPU configuration, populate the channels for CPU1 only (A, B, C, D).
• Memory mirroring reduces the amount of memory available by 50 percent because only one of the
two populated channels provides data. When memory mirroring is enabled, you mu st install DIMMs
in sets of 4, 6, 8, or 12 as described in Memory Mirroring and RAS, page 3-22.
• NVIDIA GPUs can support only less than 1 TB of memory in the server. Therefore, do not install
more than fourteen 64-GB DIMMs when using an NVIDIA GPU card in this server.
• Observe the DIMM mixing rules shown in Table 3-5.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-21
Page 64
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Table 3-5DIMM Mixing Rules for C240 M4 Servers
DIMM ParameterDIMMs in the Same ChannelDIMMs in the Same Bank
DIMM Capacity:
RDIMM = 8 or 16 GB
LRDIMM = 32 or 64 GB
DIMM Speed:
2133 or 2400 MHz
DIMM Type:
RDIMMs or LRDIMMs
Memory Mirroring and RAS
The Intel E5-2600 CPUs within the server support memory mirroring only when an even number of
channels are populated with DIMMs. If one or three channels are populated with DIMMs, memory
mirroring is automatically disabled. Furthermore, if memory mirroring is used, DRAM size is reduced
by 50 percent for reasons of reliability.
For details on populating recommended memory mirroring conf igurations, see the specif ication sheet for
the server:
• Cisco UCS C240 M4 High Density Rack Server (Small Form-Factor Disk Drive Model)
• Cisco UCS C240 M4 High Density Rack Server (Large Fo rm-Factor Disk Drive Model)
• You can mix different capacity
DIMMs in the same channel (for
example, A1, A2, A3).
Y ou can mix speeds, but DIMMs will run at
the speed of the slowest DIMMs/CPUs
installed in the channel.
You cannot mix DIMM types in a channel. You cannot mix DIMM types in a bank.
Specification Sheet
Specification Sheet
• You can mix different capacity DIMMs
in the same bank. However, for optimal
performance DIMMs in the same bank
(for example, A1, B1, C1, D1) should
have the same capacity.
You can mix speeds, but DIMMs will run at
the speed of the slowest DIMMs/CPUs
installed in the bank.
Lockstep Channel Mode
Cisco UCS C240 M4 Server Installation and Service Guide
3-22
When you enable lockstep channel mode, each memory access is a 128-bit data access that spans four
channels.
Lockstep channel mode requires that all f our memory channels on a CPU must be populated identically
with regard to size and organization. DIMM sock et popu lations within a channel (for example, A1, A2,
A3) do not have to be identical but the same DIMM slot loca tion across all four channels must be
populated the same.
For example, DIMMs in sockets A1, B1, C1, and D1 must be identical. DIMMs in sockets A2, B2, C2,
and D2 must be identical. However, the A1-B1-C1-D1 DIMMs do not have to be identical with the
A2-B2-C2-D2 DIMMs.
OL-32474-01
Page 65
Chapter 3 Maintaining the Server
DIMM Replacement Procedure
This section includes the following topics:
• Identifying a Faulty DIMM, page 3-23
• Replacing DIMMs, page 3-23
Identifying a Faulty DIMM
Each DIMM socket has a corresponding DIMM fault LED, directly in front of the DIMM socket. See
Figure 3-3 for the locations of these LEDs. The LEDs light amber to indicate a faulty DIMM. To operate
these LEDs from the SuperCap power source, remove AC power cords and then press the Unit
Identification button.
Replacing DIMMs
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
Installing or Replacing Server Components
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the air baffle that sits over the DIMM sockets and set it aside.
Step 5Identify the faulty DIMM by observing the DIMM socket fault LEDs on the motherboard (see
Figure 3-3).
Step 6Remove the DIMMs that you are replacing. Open the ejector levers at both ends of the DIMM socket,
and then lift the DIMM out of the socket.
Step 7Install a new DIMM:
NoteBefore installing DIMMs, see the population guidelines. See Memory Performance Guidelines
and Population Rules, page 3-20.
a. Align the new DIMM with the empty socket on the motherboard. Use the alignment key in the
DIMM socket to correctly orient the DIMM.
b. Push down evenly on the top corners of the DIMM until it is fully seated and the ejector levers on
both ends lock into place.
Step 8Replace the air baffle.
Step 9Replace the top cover.
Step 10Replace the server in the rack, replace cables, and then power on the server by pressi ng the Power button.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-23
Page 66
Installing or Replacing Server Components
Replacing CPUs and Heatsinks
This section contains the following topics:
• CPU Configuration Rules, page 3-24
• Replacing a CPU and Heatsink, page 3-24
• Additional CPU-Related Parts to Order with RMA Replacement Motherboards, page 3-27
CPU Configuration Rules
This server has two CPU sockets. Each CPU supports four DIMM channels (12 DIMM sockets). See
Figure 3-13.
• The server can operate with one CPU or with two identical CPUs installed.
• The minimum configuration is that the server must have at least CPU1 installed. Install CPU1 first,
and then CPU2.
• The following restrictions apply when using a single-CPU configuration:
–
The maximum number of DIMMs is 12 (only CPU1 channels A, B, C, and D).
–
PCIe riser 2, which contains PCIe slots 4, 5, and 6 is unavailable.
Chapter 3 Maintaining the Server
Replacing a CPU and Heatsink
CautionCPUs and their motherboard sockets are fragile and must be handled with care to avoid damaging pins
during installation. The CPUs must be installed with heatsinks and their thermal grease to ensure proper
cooling. Failure to install a CPU correctly might result in damage to the server.
NoteThis server uses the new independent loading mechanism (ILM) CPU sockets, so no Pick-and-Place
tools are required for CPU handling or installation. Always grasp the plastic frame on the CPU when
handling.
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the plastic air baffle that sits over the CPUs.
Step 5Remove the heatsink that you are replacing:
a. Use a Number 2 Phillips-head screwdriv er to loosen the four captive screws that secure the heatsink.
3-24
NoteAlternate loosening each screw evenly to avoid damaging the heatsink or CPU.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 67
Chapter 3 Maintaining the Server
1
2
4
3
5
352941
b. Lift the heatsink off of the CPU.
Step 6Open the CPU retaining mechanism:
a. Unclip the first retaining latch labeled with the icon, and then unclip the second retaining
latch labeled with the icon. See Figure 3-14.
b. Open the hinged CPU cover plate.
Figure 3-14CPU Socket
Installing or Replacing Server Components
1CPU retaining latch 4Hinged CPU seat
2CPU retaining latch 5Finger-grips on plastic CPU frame
3Hinged CPU cover plate
Step 7Remove any existing CPU:
a. With the latches and hinged CPU cover plate open, swing the CPU in its hinged seat up to the open
position, as shown in Figure 3-14.
b. Grasp the CPU by the finger-grips on its plastic frame an d l ift it up and out of the hinged CPU seat.
c. Set the CPU aside on an antistatic surface.
Step 8Install a new CPU:
a. Grasp the new CPU by the finger-grips on its plastic frame and align the tab on the frame that is
labeled “ALIGN” with the hinged seat, as shown in Figure 3-15.
b. Insert the tab on the CPU frame into the seat until it stops and is held firmly.
The line below the word “ALIGN” should be level with the edge of the seat, as shown in Figure 3-15.
c. Swing the hinged seat with the CPU down until the CPU frame clicks in place and holds flat in the
socket.
d. Close the hinged CPU cover plate.
e. Clip down the CPU retaining latch with the icon, and then clip down the CPU retaining latch
with the icon. See Figure 3-14.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-25
Page 68
Installing or Replacing Server Components
2
1
352942
Figure 3-15CPU and Socket Alignment Features
1SLS mechanism on socket2Tab on CPU frame (labeled ALIGN)
Chapter 3 Maintaining the Server
Step 9
CautionThe heat sink must have new thermal grease on the heat sink-to-CPU surface to ensure proper cooling.
Install a heat sink:
If you are reusing a heat sink, you must remove the old thermal grease from the heatsink and the CPU
surface. If you are installing a new heat sink, skip to Step c.
a. Apply the cleaning solution, which is included with the heatsink cleaning kit (UCSX-HSCK=,
shipped with spare CPUs), to the old thermal grease on the heatsink and CPU and let it soak for a
least 15 seconds.
b. Wipe all of the old thermal grease off the old heat sink and CPU using the soft cloth that is included
with the heatsink cleaning kit. Be careful to not scratch the heat sink surface.
NoteNew heatsinks come with a pre-applied pad of ther mal grease. If you are reusing a heatsink, you
must apply thermal grease from a syringe (UCS-CPU-GREASE3=).
c. Align the four heatsink captive screws with the motherboard standoffs, and then use a Number 2
Phillips-head screwdriver to tighten the captive screws evenly.
NoteAlternate tightening each screw evenly to avoid damaging the heatsink or CPU.
Step 10Replace the air baffle.
Step 11Replace the top cover.
Step 12Replace the server in the rack, replace cables, and then power on the server by pressi ng the Power button.
3-26
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 69
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Additional CPU-Related Parts to Order with RMA Replacement Motherboards
When a return material authorization (RMA) of the motherboard or CPU is done on a Cisco UCS
C-series server, additional parts might not be included with the CPU or motherboard spare bill of
materials (BOM). The TAC engineer might need to add the additional parts to the RMA to help ensure
a successful replacement.
NoteThis server uses the new independent loading mechanism (ILM) CPU sockets, so no Pick-and-Place
tools are required for CPU handling or installation. Always grasp the plastic frame on the CPU when
handling.
• Scenario 1—You are reusing the existing heatsinks:
–
Heat sink cleaning kit (UCSX-HSCK=)
–
Thermal grease kit for C240 M4 (UCS-CPU-GREASE3=)
• Scenario 2—You are replacing the existing heatsinks:
–
Heat sink (UCSC-HS-C240M4=)
–
Heat sink cleaning kit (UCSX-HSCK=)
A CPU heatsink cleaning kit is good for up to four CPU and heatsi nk cleanings. The cleaning kit con tains
two bottles of solution, one to clean the CPU an d heatsink of old ther mal interface materi al and the other
to prepare the surface of the heatsink.
New heatsink spares come with a pre-applied pad of thermal grease. It is important to clean the old
thermal grease off of the CPU prior to installing the heatsinks. Therefore, when you are ordering new
heatsinks, you must order the heatsink cleaning kit.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-27
Page 70
Installing or Replacing Server Components
Replacing a SATA Interposer Board
The server uses a SATA interposer board and cable to connect the embedded RAID (PCH SATA)
controller on the motherboard to the drive backplane. See Figure 3-16 for the socket location.
NoteThe SATA interposer board and embedded RAID can be used only with the SFF, 8-drive backplane
version of the server. It does not operate with an expander. You cannot use the embedded RAID
controller and a hardware RAID controller card at the same time.
See Embedded SATA RAID Controller, page C-11 for more information about using the embedded
RAID controller and options.
Step 1Power off the server as described in the Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
Chapter 3 Maintaining the Server
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the plastic air baffle that sits over the CPUs to gain access to the interposer cables.
Step 5Remove PCIe riser 1 from the server to provide clearance. See Replacing a PCIe Riser, page 3-41.
Step 6Remove any existing PCH SATA interposer board:
a. Disconnect both ca ble conne ctors from the interposer board.
b. Lift straight up on the board to remove it from its motherboard socket.
Step 7Install a new interposer board and cables:
NoteThe required Y-cable and SATA interposer board are bundled as UCSC-IP-PCH-C240M4=.
a.
Align the board with the socket, and then gently press down on both top corners to seat it evenly.
b. Connect the single mini-SAS HD cable connector to the single connector on the backplane.
c. Route the cables through the plastic clips on the chassis wall.
d. Connect PORT A and PORT B cable connectors to their corresponding connectors on the new
interposer board.
Step 8Replace PCIe riser 1 to the server.
Step 9Replace the air baffle.
3-28
Step 10Replace the top cover.
Step 11Replace the server in the rack, replace cables, and then power on the server by pressi ng the Power button.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 71
Chapter 3 Maintaining the Server
352960
FAN 05
FAN 04
FAN 03
FAN 02
FAN 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
1
Figure 3-16SATA Interposer Board Socket Location
Installing or Replacing Server Components
1SATA interposer board socket on motherboard
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-29
Page 72
Installing or Replacing Server Components
Replacing a Cisco Modular RAID Controller Card
The server has an internal, dedicated PCIe slot on the motherboard for a Cisco modular RAID controller
card (see Figure 3-17).
• Replacing the Supercap Power Module (RAID Backup Battery), page 3-34
NoteYou cannot use a hardware RAID controller card and the embedded RAID controller at the same time.
See RAID Controller Considerations, page C-1 for details about RAID support.
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
Chapter 3 Maintaining the Server
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove an existing RAID controller card:
a. Disconnect the data cable from the card. Depress the tab on the c able connector and pull.
b. Disconnect the supercap power module cable from the transportable memory module (TMM), if
present.
c. Lift straight up on the metal bracket that holds the card. The bracket lifts off of two pegs on the
chassis wall.
d. Loosen the two thumbscrews that hold the card to the metal bracket and then lift the card from the
bracket.
Step 5Install a new RAID controller card:
a. Set the new card on the metal bracket, aligned so that the thumbscrews on the card enter the thre aded
standoffs on the bracket. Tighten the thumbscrews to secure the card to the bracket.
b. Align the two slots on the back of the bracket with the two pegs on the chassis wall.
The two slots on the bracket must slide down over the pegs at the same time that you push the card
into the motherboard socket.
c. Gently press down on both top corners of the metal bracket to seat the card into the socket on the
motherboard.
d. Connect the supercap power module cable to its connector on the TM M, if present.
3-30
e. Connect the single data cable to the card.
Step 6Replace the top cover.
Step 7Replace the server in the rack, replace cables, and then power on the serv er by pressing the Power button.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 73
Chapter 3 Maintaining the Server
352961
FAN 05
FAN 04
FAN 03
FAN 02
FAN 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
2
1
Installing or Replacing Server Components
1Thumbscrews on card2Cisco modular RAID controller bracket
Figure 3-17Modular RAID Controller Card Location
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-31
Page 74
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Replacing a Modular RAID Controller Transportable Memory Module (TMM)
The transportable memory module (TMM) that attaches to the modular RAID controller card can be
installed or replaced after-factory.
See also:
• Replacing a Cisco Modular RAID Controller Card, page 3-30
• Replacing the Supercap Power Module (RAID Backup Battery), page 3-34
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the modular RAID controller card from the server:
a. Lift straight up on the metal bracket that holds the card. The bracket lifts off of two pegs on the
chassis wall (see Figure 3-17).
b. Disconnect the supercap power module cable from the TMM that is attached to the card.
Step 5Remove the TMM from the modular RAID controller card (see Figure 3-18):
a. The plastic bracket on the card has a securing plastic clip at each end of the TMM. Gently spread
each clip away from the TMM.
b. Pull straight up on the TMM to lift it off the two plastic guide pegs and the socket on the card.
Step 6Install a TMM to the modular RAID controller card (see Figure 3-18):
a. Align the TMM over the bracket on the card. Align th e connector on the underside of th e TMM with
the socket on the card. Align the two guide holes on the TMM over the two guide pegs on the card.
CautionIn the next step, keep the TMM level and parallel with the surface of the card to avoid damaging the
connector or socket.
b. Gently lower the TMM so that the guide holes on the TMM go over the guide pegs on the card.
c. Press down on the TMM until the plastic clips on the bracket close over each end of the TMM.
d. Press down on the TMM to fully seat its connector with the socket on the card.
Step 7Install the modular RAID controller card back into the server:
NoteIf this is a first-time installation of your TMM, you must also install a supercap po wer module (SCPM).
The SCPM cable attaches to a connector on the TMM. See Replacing the Supercap Power Module
(RAID Backup Battery), page 3-34.
3-32
a. Connect the cable from the supercap power module (RAID battery) to the connector on the TMM
(see Figure 3-18).
b. Align the two slots on the back of the RAID card bracket with the two pegs on the chassis wall.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 75
Chapter 3 Maintaining the Server
304945
4
1
657
3
2
8
11
2
The two slots on the bracket must slide down over the pegs at the same time that you push the card
into the motherboard socket.
c. Gently press down on both top corners of the metal bracket to seat the card into the socket on the
motherboard.
Installing or Replacing Server Components
Figure 3-18TMM on Modular RAID Controller Card
1TMM on modular RAID card5Side view, guide peg
2Securing bracket clips6Side view, socket on modular RAID card
3Guide pegs on bracket protruding through
4SCPM ca ble connector on TMM8Side view, securing clips
guide holes on TMM
7Side vi ew, connector on underside of TMM
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-33
Page 76
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Replacing the Supercap Power Module (RAID Backup Battery)
This server supports installation of one supercap power module (SCPM). The unit mounts to a clip on
the removable air baffle (see Figure 3-19). The SCPM requires that you have a transportable memory
module (TMM) attached to your RAID controller card because the connector for the SCPM cable is on
the TMM.
See also:
• Replacing a Cisco Modular RAID Controller Card, page 3-30
The SCPM provides approximately three years of backup for the disk write-back cache DRAM in the
case of a sudden power loss by offloading the cache to the NAND flash.
Warning
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
There is danger of explosion if the battery is replaced incorrectly. Replace the battery only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according to
the manufacturer’s instructions.
Statement 1015
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove an existing SCPM:
a. Disconnect the existing SCPM cable from the transportable memory module (TMM) that is attached
to the modular RAID controller card.
b. Pull back the plastic clip that closes over the SCPM slightly, and then slide the SCPM free of the
clips on the air baffle mounting point (see Figure 3-19).
Step 5Install a new SCPM:
a. Slide the new backup unit into the holder on the air baffle mounting point until the clip clicks over
the top edge of the SCPM.
3-34
b. Connect the cable from the SCPM to the TMM that is attached to the modular RAID controller card.
NotePut the cable through the opening on the rear of the air baffle (rather than over the air baffle) to
keep the cable from interfering with the top cover of the server.
Step 6Replace the top cover.
Step 7Replace the server in the rack, replace cables, and then power on the serv er by pressing the Power button.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 77
Chapter 3 Maintaining the Server
Figure 3-19SCPM (RAID Backup Unit) Mounting Point and Cable Path
FAN 05
FAN 0 4
CPU 2
SD2
Installing or Replacing Server Components
SD1
FAN 03
FAN 02
FAN 01
CPU 1
1
1SCPM mounting point on removable air baffle
(air baffle not shown)
Riser 2
Riser 1
352962
2
2SCPM cable routing path (the red line)
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-35
Page 78
Installing or Replacing Server Components
352963
FAN 05
FAN 0 4
FAN 03
FAN 02
FAN 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
1
Replacing a Software RAID 5 Key Module
The server has a two-pin header on the motherboard for a RAID 5 key module. This module upgrades
the embedded SATA RAID controller options (see Embedded SATA RAID Control ler, page C-11).
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove any existing software RAID key module:
a. Locate the module on the motherboard (see Figure 3-20).
b. Hold the retention clips on the header open while you grasp the RAID key board and pull straight
up (see Figure 3-21).
Chapter 3 Maintaining the Server
Figure 3-20RAID 5 Key Header Location on Motherboard
1Software RAID 5 key header (adds RAID 5
support)
3-36
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 79
Chapter 3 Maintaining the Server
303691
3
4
2
1
1
2
Step 5Install a new software RAID key module:
a. Align the module with the pins in the motherboard header.
b. Gently press down on the module until it is seated and the retention clip lo cks over the module (see
1Printed circuit board on module3Motherboard header
2Retention clip on motherboard header4Retention clip in installed position
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-37
Page 80
Installing or Replacing Server Components
Replacing the Motherboard RTC Battery
Chapter 3 Maintaining the Server
Warning
There is danger of explosion if the battery is replaced incorrectly. Replace the battery only with the
same or equivalent type recommended by the manufacturer. Dispose of used batteries according to
the manufacturer’s instructions.
[Statement 1015]
The real-time clock (RT C) battery retains system settings when the server is disconnected from power.
The RTC battery is on the motherboard near the RAID controller card socket (see Figure 3-22).
The battery type is Panasonic CR2032 or equivalent.
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the battery from its holder on the motherboard (see Figure 3-22):
a. Use a small screwdriver or pointed object to press inward on the battery at the prying point (see
Figure 3-22).
b. Lift up on the battery and remove it from the holder.
Step 5Install an RTC battery. Insert the battery into its holder and press down until it clicks in place.
NoteThe positive side of the battery marked “3V+” should face upward.
Step 6Replace the top cover.
Step 7Replace the server in the rack, replace cables, and power on the server by pressing the Power butt o n .
3-38
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 81
Chapter 3 Maintaining the Server
352964
FAN 05
FAN 0 4
FAN 03
FAN 02
FAN 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
12
Figure 3-22RTC Battery Location and Prying Point
Installing or Replacing Server Components
1RTC battery holder on motherboard 2Prying point
Replacing an Internal SD Card
The server has two internal SD card bays on the motherboard.
Dual SD cards are supported. RAID 1 support can be configured through the Cisco IMC interface.
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove an SD card (see Figure 3-23).
a. Push on the top of the SD card, and then release it to allow it to spring out from the slot.
b. Remove the SD card from the slot.
Step 5Install an SD card:
a. Insert the SD card into the slot with the label side facing up.
b. Press on the top of the card until it clicks in the slot and stays in place.
Step 6Replace the top cover.
OL-32474-01
Step 7Replace the server in the rack, replace cables, and then power on the serv er by pressing the Power button.
Cisco UCS C240 M4 Server Installation and Service Guide
3-39
Page 82
Installing or Replacing Server Components
Figure 3-23SD Card Bay Location and Numbering on the Motherboard
FAN 05FAN 06
FAN 04
CPU 2
Chapter 3 Maintaining the Server
1
SD2
SD1
FAN 03
FAN 02
FAN 01
CPU 1
1SD card bays SD1 and SD2
Enabling or Disabling the Internal USB Port
CautionWe do not recommend that you Hot-swap the internal USB drive while the server is powered on.
The factory default is for all USB ports on the server to be en able d. However, the internal USB port can
be enabled or disabled in the server BIOS. See Figure 3-5 for the location of the internal USB 3.0 slot
on the motherboard.
Riser 2
Riser 1
352969
3-40
Step 1Enter the BIOS Setup Utility by pressing the F2 key when prompted during bootup.
Step 2Navigate to the Advanced tab.
Step 3On the Advanced tab, select USB Configuration.
Step 4On the USB Configuration page, choose USB Ports Configuration.
Step 5Scroll to USB Port: Internal, press Enter, and then choose either Enabled or Disabled from the dialog
box.
Step 6Press F10 to save and exit the utility.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 83
Chapter 3 Maintaining the Server
Replacing a PCIe Riser
The server contains two toolless PCIe risers for horizontal installation of PCIe cards. See Replacing a
PCIe Card, page 3-43 for the specifications of the PCIe slots on the risers.
Step 1Power off the server as described in Shutting Down and Powering Off the Server, page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the PCIe riser that you are replacing (see Figure 3-24):
a. Grasp the top of the riser and lift straight up on both ends to disengage its circuit board from the
socket on the motherboard. Set the riser on an antistatic mat.
b. If the riser has a card installed, remove the card from the riser. SeeReplacing a PCIe Card,
page 3-43.
Installing or Replacing Server Components
Step 5Install a new PCIe riser:
a. If you removed a card from the old PCIe riser , i nstall the card to the n e w riser (seeReplacing a PCIe
Card, page 3-43).
b. Position the PCIe riser over its socket on the motherboard and ov er it s alignment slots in the chassis
(see Figure 3-24). There are also two alignment pegs on the motherboard for each riser.
NoteThe PCIe risers are not interchangeable. If you plug a PCIe riser into the wrong socket, the server
will not boot. Riser 1 must plug into the motherboard socket labeled “RISER1.” Riser 2 must
plug into the motherboard socket labeled “RISER2.”
c. Carefully push down on both ends of the PCIe riser to fully engage its circuit board connector with
the socket on the motherboard.
Step 6Replace the top cover.
Step 7Replace the server in the rack, replace cables, and then power on the serv er by pressing the Power button.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-41
Page 84
Installing or Replacing Server Components
352970
FAN 05FAN 06
FAN 04
FAN 0 3
FAN 02
FAN 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
1
2
Figure 3-24PCIe Riser Alignment Features
Chapter 3 Maintaining the Server
1Alignment peg locations on motherboard
(two for each riser)
2Alignme nt channel locations on chassis
(two for each riser)
3-42
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 85
Chapter 3 Maintaining the Server
Replacing a PCIe Card
CautionCisco supports all PCIe cards qualified and sold by Cisco. PCI e cards not quali fied or sold by Cisco are
the responsibility of the customer. Although Cisco will always stand behind and support the C-Series
rack-mount servers, customers using standard, off-the -shelf, third-p arty card s must go to the t hird-party
card vendor for support if any issue with that particular third-party card occurs.
This section includes the following topics:
• PCIe Slots, page 3-43
• Replacing a PCIe Card, page 3-45
• Special Considerations for Cisco UCS Virtual Interface Cards, page 3-47
• Special Considerations for Cisco UCS Fusion ioDrive3 Storage Accelerator Cards, page 3-48
4
5Gen-3 x16x24 connectorFull length Full height Yes
Lane WidthConnector LengthCard Length Card Height NCSI Support
Gen-3 x8x24 connector 3/4 length Full height Yes
1
6Gen-3 x8x16 connectorFull lengthFull height No
1. NCSI is supported in only one slot at a time in this riser version. If a GPU card is present in slot 5, NCSI support automatically moves to slot 4.
3-44
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 87
Chapter 3 Maintaining the Server
Replacing a PCIe Card
The Technical Specifications Sheets for all versions of this server, which include supported component
part numbers, are at Cisco UCS Servers Technical Specifications Sheets.
NoteIf you are installing a Cisco UCS Virtual Interface Card, there are prerequisite considerations. See
Special Considerations for Cisco UCS Virtual Interface Cards, page 3-47.
NoteIf you are installing a Fusion ioDrive2 card, there are prerequisite considerations. See Special
NoteIf you are installing a RAID controller card, see RAID Controller Considerations, page C-1 for more
information about supported cards and cabling.
Step 1Shut down and power off the server as described in Shutting Down and Powering Off the Server,
page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
Installing or Replacing Server Components
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove a PCIe card (or a blanking panel) from the PCIe riser:
a. Lift straight up on both ends of the riser to disengage its circuit board from the socket on the
motherboard. Set the riser on an antistatic mat.
b. On the bottom of the riser, loosen the single thumbscrew that holds the securing plate (see
Figure 3-26).
c. Swing open the securing plate and remove it from the riser to provide access.
d. Swing open the card-tab retainer that secures the back-panel tab of the card (see Figure 3-26).
e. Pull evenly on both ends of the PCIe card to disengage it from the socket on the PCIe riser (or
remove a blanking panel) and then set the card aside.
Step 5Install a PCIe card:
a. Align the new PCIe card with the empty socket on the PCIe riser.
b. Push down evenly on both ends of the card until it is fully seated in the socket.
Ensure that the card rear panel tab sits flat against the PCIe riser rear panel opening.
c. Close the card-tab retainer (see Figure 3-26).
d. Return the securing plate to the riser. Insert the two hinge-tabs into the two slots on the riser, and
then swing the securing plate closed.
OL-32474-01
e. Tighten the single thumbscrew on the bottom of the securing plate.
f. Position the PCIe riser over its socket on the motherboard and over its alignment features in the
chassis (see Figure 3-24).
Cisco UCS C240 M4 Server Installation and Service Guide
3-45
Page 88
Installing or Replacing Server Components
353239
4
3
2
1
g. Carefully push down on both ends of the PCIe riser to fully engage its circuit board connector with
the socket on the motherboard.
Step 6Replace the top cover.
Step 7Replace the server in the rack, replace cables, and then power on the serv er by pressing the Power button.
Step 8If you replaced a RAID controller card, continue with Restoring RAID Configuration After Replacing a
RAID Controller, page C-25.
Chapter 3 Maintaining the Server
Figure 3-26PCIe Riser Securing Features (Three-Slot Riser Shown)
1Securing plate hinge-tabs3GPU card power connector
2Securing plate thumbscrew (knob not visible
4Card-tab retainer in open position
on underside of plate)
Cisco UCS C240 M4 Server Installation and Service Guide
3-46
OL-32474-01
Page 89
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Special Considerations for Cisco UCS Virtual Interface Cards
Table 3-10 describes the requirements for the supported Cisco UCS virtual interface cards (VICs).
The server can support up to two PCIe-style VIC s plus one mL OM-style V IC.
NoteIf you use the Cisco Card NIC mode, you must also make a VIC Slot setting that matches where your
VIC is installed. The options are Riser1, Riser2, or Flex-LOM. See NIC Modes and NIC Redundancy
Settings, page 2-14.
If you want to use the Cisco UCS VIC card for Cisco UCS Manager integr ation, also see the Cisco UCS
C-Series Server Integration with UCS Mana ger Gu ides for details about supported configurations,
cabling, and other requirements.
Table 3-10Cisco UCS C240 M4 Requirements for Virtual Interface Cards
1. For riser PID UCSC-PCI-1B-240M4: slot 2 is the only slot that supports a VIC in riser version 1B. In this riser version, slot 2 is an 8x lan e, so if yo u are using
Cisco UCS VIC1385, give it priority on slot 5 instead for best performance.
2. Although all slots support standby power, we recommend that you use an mLOM card for Cisco UCS Manager integration. Slot 2 is the primary
PCIe slot for integration, but if an mLOM-style card is present it takes priority over the PCIe slot for integration.
3. Although all slots support standby power , we recommend that you use an mLOM card for Cisco UCS Manager integration. Slot 2 is the primary
PCIe slot for integration, but if an mLOM-style card is present it takes priority over the PCIe slot for integration.
4. For Cisco UCS VIC1385, always use the primary slots 2 and 5 for optimal performance. You can use the other supported slots , but you might see
degraded performance. If multiple VIC cards are present, give the Cisco UCS VIC1385 priority on the primary slots 2 and 5 for best performance.
Primary Slot for
Cisco UCS
Manager
Integration
Riser 1: PCIE 2
See footnote.
See footnote.
1
this time
Primary Slot for
Cisco Card NIC
Mode
Riser 1: PCIE 2
2
Riser 2: PCIE 5
Riser 1: PCIE 2
3
Riser 2: PCIE 5
Riser 1: PCIE 2
Riser 2: PCIE 5
Minimum
Cisco IMC
Firmware
Minimum VIC
Firmware
1.4(6)2.1(0)
1.5(1)2.1(1)
2.0(4)4.0(4b)
OL-32474-01
NoteThe Cisco UCS VIC 1227 (UCSC-MLOM-CSC-02) is not compatible to use in Cisco Card NIC mode
with a certain Cisco SFP+ module. Do not use a Cisco SFP+ module part number 37-0961-01 that has a
serial number in the range MOC1238xxxx to MOC1309xxxx. If you use the Cisco UCS VIC 1227 in
Cisco Card NIC mode, use a different part number Cisco SFP+ module, or you can use this part number
37-0961-01 if the serial number is not included in the range above. See the data sheet for this adapter for
other supported SFP+ modules: Cisco UCS VIC 1227 Data Sheet
Cisco UCS C240 M4 Server Installation and Service Guide
3-47
Page 90
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
Special Considerations for Cisco UCS Fusion ioDrive3 Storage Accelerator Cards
Table 3-11 describes the requirements for the supported Cisco UCS Fusion ioDrive3 cards.
1. PCIe riser 1 versions UCSC-PCI-1A-240M4 and UCSC-PCI-1C-240M4 have only two slots and therefore, when using those versions only five cards are
supported in the server.
2. All slots can be enabled to provide more than the default 25 W power draw for higher performance on some cards. S e eEnabling Higher Power-Draw for
Fusion ioDrive3 Cards, page 3-48.
3. A rear-panel tab adapter is required to fit the half-height cards in full-height slots.
6All Not
applicable
6All Not
applicable
6All Not
applicable
Minimum
Cisco IMC
Firmware
Card Height
(rear-panel
tab)
2.0(2)Full height
2.0(2)Half height
2.0(2)Half height
2.0(2)Half height
3
Enabling Higher Power-Draw for Fusion ioDrive3 Cards
Some Fusion ioDrive3 accelerator cards such as the 5800 GB card draw 25 W by default b ut can achie v e
higher performance when the PCIe slot is configured to provide more than 25 W for the device.
PCIe Slots That Can Be Configured to Support More Than 25 W Power Draw: All.
All slots can support the higher device po wer dra w of 55 W (75 W maximum) when conf ig ured with the
override parameter in the IO Accelerator VSL software.
NoteSee the UCS power calculator to determine the total power draw for your exact server configuration at
How to Enable Higher Power Draw for a Device with the IO Accelerator Override Parameter
The override parameter in the IO Accelerator VSL software (in the
/usr/modprove.d/iomemory-vsl.conf file) overrides the setting that prevents devices from drawing
more than 25 W from the PCIe slot. The paramete r is enabled by device, by using the device serial
numbers.
NoteThe override parameter persists in the server and enables full power draw on an enabled device even if
the device is removed and then placed in a different slot within the same system. If the device is moved
to a slot that is not rated to provide 55 W of power, the server hardware could experience a power drag.
3-48
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 91
Chapter 3 Maintaining the Server
NoteThe override parameter is a setting for the IO Accelerator VSL software by server and is not stored in
the device. When moved to a new server, the device defaults to the 25 W power limit until an external
power cable is added or the override parameter is enabled for that device in the new server.
Step 1Determine the serial number of the installed Fusion de vi ce by usin g the fio-status command in the IO
Accelerator VSL software. Sample output is shown here:
Resolving Insufficient Memory Space to Execute Option ROMs
The system has very limited memory to execute PCIe legacy option ROMs, so when a large number of
PCIe add-on cards are installed in the server, the system BIOS might not able to e xecute all of the option
ROMs. The system BIOS loads and executes the option ROMs in the order that the PCIe cards are
enumerated (slot 1, slot 2, slot 3, and so on).
If the system BIOS does not have suf ficient memory sp ace to load any PCIe option R OM, it skips load ing
that option ROM, reports a system event log (SEL) event to the Cisco IMC controller and reports the
following error in the Error Manager page of the BIOS Setup utility:
ERROR CODE SEVERITYINSTANCEDESCRIPTION
146MajorN/APCI out of resources error.
Major severity requires user
intervention but does not
prevent system boot.
Chapter 3 Maintaining the Server
To resolve this issue, disable the Option ROMs that are not needed for system booting. The BIOS Setup
Utility provides the setup options to enable or disable the Option ROMs at the PCIe slot level for the
PCIe expansion slots and at the port level for the onboard NICs. These options can be found in the BIOS
Setup Utility Advanced PCI Configuration page.
• Guidelines for RAID controller booting
If the server is configured to boot primarily from RAID storage, make sure that the option ROMs
for the slots where your RAID controllers installed are enabled in the BIOS, depending on your
RAID controller configuration.
If the RAID controller does not appear in the system boot order ev en with the option R OMs for those
slots are enabled, the RAID controller option ROM might not have sufficient memory space to
execute. In that case, disable other op tion ROMs that are not needed for the system configuration to
free up some memory space for the RAID controller option ROM.
• Guidelines for onboard NIC PXE booting
If the system is configured to primarily perform PXE boot from onboard NICs, make sure that the
option ROMs for the onboard NICs to be booted from are enabled in the BIOS Setup Utility. Disable
other option ROMs that are not needed to create sufficient memory space for the onboard NICs.
3-50
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 93
Chapter 3 Maintaining the Server
Resolving Insufficient 16-Bit I/O Space
The system has only 64 KB of legacy 16-bit I /O resources available. This 64 KB of I/O space is divided
between the CPUs in the system because the PCIe contr oller is in tegrated into the CPUs . This server
BIOS has the capability to dynamically detect the 16-bit I/O resource requirement for each CPU and then
balance the 16-bit I/O resource allocation between the CPUs during the PCI bus enumeration phase of
the BIOS POST.
When a large number of PCIe cards are installed in the system, the system BIOS might not have
sufficient I/O space for some PCIe devices. If the system BIOS is not able to allocate the required I/O
resources for any PCIe devices, the following symptoms have been observed:
• The system might get stuck in an infinite reset loop.
• The BIOS might appear to hang while initializing PCIe devices.
• The PCIe option ROMs might tak e excessi v e time to complete, which appears t o lock up the system.
• PCIe boot devices might not be accessible from the BIOS.
• PCIe option ROMs might report initialization errors. These errors are seen before the BIOS passes
control to the operating system.
• The keyboard might not work.
To work around this problem, rebalance the 16-bit I/O load using the following methods:
1. Physically remove any unused PCIe cards.
Installing or Replacing Server Components
2. If the system has one or more Cisco virtual interface cards (VICs) installed, disable the PXE boot
on the VICs that are not required for the system boot configuration by using the Network Adapters
page in Cisco IMC Web UI to free up some 16-bit I/O resources. Each VIC uses a minimum 16 KB
of 16-bit I/O resource, so disabling PXE boot on Cisco VICs would free up some 16-bit I/O
resources that can be used for other PCIe cards that are installed in the system.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-51
Page 94
Installing or Replacing Server Components
Chapter 3 Maintaining the Server
Installing an NVIDIA GPU Card
This section contains the following topics:
• Overview of Software Requirements, page 3-52
• GPU Card Configuration Rules, page 3-52
• Requirement For All Supported GPUs: Memory-Mapped I/O Greater than 4 GB, page 3-53
• Replacing a GPU Card, page 3-54
• Installing an NVIDIA K80 GPU Card and Conversion Kit, page 3-56
• Installing Drivers to Support the NVIDIA GPU Cards, page 3-63
Overview of Software Requirements
Table 3-12 lists the minimum server firmware versions for the GPU cards.
Table 3-12Server Firmware Minimum Versions
GPUCisco IMC/BIOS Minimum Version
NVIDIA GRID K12.0(3 a)
NVIDIA GRID K22.0(3 a)
NVIDIA Tesla K102.0(3e)
NVIDIA Tesla K202.0(3e)
NVIDIA Tesla K20X2.0(3 e)
NVIDIA Tesla K402.0(3a)
NVIDIA Tesla K802.0(6)
GPU Card Configuration Rules
The rules for configuring the server with GPUs differ , depending on the server version and other factors.
Observe the following rules when populating GPUs in the server:
• For riser 1, use version 1A (slot 2) for GPU cards. This server can be ordered with one of three PCIe
riser 1 versions. GPU cards are not supported in version 1B (UCSC-PCI-1B-240M4) or 1C
(UCSC-PCI-1C-240M4).
• GPU cards are also supported in PCIe riser 2, slot 5.
CautionCisco C240 M4 LFF and C240 M4 SFF 24-drive servers only: When using NVIDIA GPU cards, you
must preserve at least 10 mm of space between servers to ensure adequate air flow. When using GPU
cards with this version of the server, the operating temperature range is 32° to 95° F (0° to 35° C).
• Mixing rules:
–
You can mix GRID K1 and K2 GPU cards in the same server.
–
Do not mix GRID GPU cards with Tesla GPU cards in the same server.
–
Do not mix different models of Tesla GPU cards in the same server.
• All GPU cards require two CPUs and two minimum 1400 W power supplies in the server.
• NVIDIA GPUs can support only less than 1 TB of memory in the server. Therefore, do not install
more than fourteen 64-GB DIMMs when using an NVIDIA GPU card in this server.
3-52
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 95
Chapter 3 Maintaining the Server
Installing or Replacing Server Components
• Table 3-13 shows the rules for populating GPU cards in the server.
Table 3-13NVIDIA GPU Population Rules
Single GPU Other Than K80Single K80 GPUDual GPUs (A l l )
Riser 1A, slot 2
or
Riser 2, slot 5
NoteWhen you install a GPU card in slot 2, NCSI support in riser 1A automatically moves to slot 1. When
Riser 1A, slot 2Riser 1A, slot 2
and
Riser 2, slot 5
you install a GPU card in slot 5, NCSI support in riser 2 automatically moves to slot 4. Therefore, you
can install a GPU card and a Cisco UCS VIC in the same riser.
Requirement For All Supported GPUs: Memory-Mapped I/O Greater than 4 GB
All supported GPU cards require enablement of the BIOS setting that allows greater than 4 GB of
memory-mapped I/O (MMIO).
Standalone Server
If the server is used in standalone mode, this BIOS setting is enabled by default:
If you need to change this from a different setting, enter the BIOS Setup Utility by pressing F2 when
prompted during bootup.
Cisco UCS Manager Controlled Server
If the server is inte grat ed with Ci sco UCS Manag er and co ntrolled by a ser vice prof ile, this setting is not
enabled by default in the service profile. You must enable it with a BIOS policy in your service profile.
Step 1Refer to the Cisco UCS Manager configuration guide (GUI or CLI) for your release for instructions on
configuring service profiles:
Cisco UCS Manager Configuration Guides
Step 2Refer to the chapter on Configuring Server-Related Policies > Configuring BIOS Settings.
Step 3In the section of your profile for PCI Configuration BIOS Settings, set Memory Mapped IO Above 4GB
Config
to one of the following:
• Enabled—Maps I/O of 64-bit PCI devices to 64 GB or greater address space.
• Platform Default—The policy uses the value for this attribute contained in the BIOS defaults for
the server. Use this only if you know that the server BIOS is set to use the default enabled setting
for this item.
Step 4Reboot the server.
NoteCisco UCS Manager pushes BIOS configuration changes through a BIOS policy or default BIOS
settings to the Cisco Integrated Management Controller (CIMC) buffer. These changes remain
in the buffer and do not take effect until the server is rebooted.
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-53
Page 96
Installing or Replacing Server Components
Replacing a GPU Card
NoteThe NVIDIA K80 GPU card requires a special conversion kit to be installed to this server. Use the
procedure in Installing an NVIDIA K80 GPU Card and Conversion Kit, page 3-56 rather than the
procedure below.
Step 1Shut down and power off the server as described in Shutting Down and Powering Off the Server,
page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4Remove the PCIe risers and any existing GPU card:
a. Lift straight up on both ends of the riser to disengage its circuit board from the socket on the
motherboard. Set the riser on an antistatic mat.
Chapter 3 Maintaining the Server
b. On the bottom of the riser, loosen the single thumbscrew that holds the securing plate. See
Figure 3-26.
c. Swing open the securing plate and remove it from the riser to provide access.
d. Swing open the card-tab retainer that secures the back-panel tab of the card (see Figure 3-26).
e. Pull evenly on both ends of the GPU card to disengage it from the socket on the PCIe riser (or
remove a blanking panel) and then set the card aside.
NoteSee GPU Card Configuration Rules, page 3-52 before you install the GPU cards to the risers. Slot
population restrictions apply.
Step 5Install your first GPU card into PCIe slot 2 or slot 5. See Figure 3-25 for the riser and slot locations.
NoteGPU cards are not supported in PCIe riser 1 version 1B (UCSC-PCI-1B-240M4) or 1C
(UCSC-PCI-1C-240M4). Use riser 1 version 1A (slot 2) or riser 2 (slot 5) for GPU cards.
a. Align the GPU card with the socket on the riser, and then gently push the card’s edge connector into
the socket. Press evenly on both corners of the card to avoid damaging the connector.
b. Connect the GPU card power cable into the GPU card and into the GPU POWER connector on the
PCIe riser (see Figure 3-26).
c. Return the securing plate to the riser. Insert the two hinge-tabs into the two slots on the riser, and
then swing the securing plate closed.
d. Tighten the single thumbscrew that holds the securing plate.
e. Close the card-tab retainer (see Figure 3-26).
3-54
f. Position the PCIe riser over its socket on the motherboard and over its alignment features in the
chassis (see Figure 3-24).
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 97
Chapter 3 Maintaining the Server
g. Carefully push down on both ends of the PCIe riser to fully engage its circuit board connector with
the socket on the motherboard.
Step 6Replace the top cover.
Step 7Replace the server in the rack, replace cables, and then power on the serv er by pressing the Power button.
Step 8Continue with Installing Drivers to Support the NVIDIA GPU Cards, page 3-63.
Installing or Replacing Server Components
OL-32474-01
Cisco UCS C240 M4 Server Installation and Service Guide
3-55
Page 98
Installing or Replacing Server Components
Installing an NVIDIA K80 GPU Card and Conversion Kit
The NVIDIA K80 GPU card requires a special conversion kit for the Cisco UCS C240 M4 server.
NVIDIA K80 GPU Card Conversion Kit
The contents of the conversion kit are as follows:
• Replacement fan-module fan cage
• CPU cleaning kit
• Low-profile CPU heatsinks (two)
• Replacement air baffle (includes base, bridge, and filler panel)
• NVIDIA K80 GPU card
• NVIDIA K80 GPU card front support bracket
• NVIDIA K80 GPU card power cable
Installing the NVIDIA K80 GPU Card
Chapter 3 Maintaining the Server
Step 1Shut down and power off the server as described in Shutting Down and Powering Off the Server,
page 3-9.
Step 2Slide the server out the front of the rack far enou gh so that you can remov e the top co ver. Y ou might ha ve
to detach cables from the rear panel to provide clearance.
CautionIf you cannot safely view and access the component, remove the server from the rack.
Step 3Remove t h e to p c over a s d e s c ri b ed i n Removing and Replacing the Server Top Cover, page 3-10.
Step 4If the server has a SuperCap power module (RAID battery unit) in the holder on the air baffl e, disconnect
the cable from the module and then remove it from the clips on the air baffle and set it aside
(Figure 3-27).
Step 5Remove the plastic air-baffle that covers the CPUs and DIMMs.
Step 6Remove the existing server fan cage (see Figure 3-27):
a. Open the plastic locking-lever at each end of the existing fan cage to the upright 90-degree position.
b. Lift the existing fan cage with fan modules from the server. Set the fan cage with fan modules aside.
Step 7Install the new empty server fan cage from the conversion kit:
a. Open the plastic locking-lever at each end of the new fan cage to the upright 90-degree position.
b. Set the new fan cage into the guides on the chassis walls and then lower the cage evenly.
c. Close the plastic locking-lever at each end of the fan cage to the flat, locked position.
3-56
Step 8Move the six fan modules from the old fan cage to the new fan cage that you just installed:
a. Pinch the two finger latches on each fan module together, then lift up on the module to remove it
from the cage (see Figure 3-27).
b. Set the fan module in an open slot in the new fan cage, aligning the connector on the bottom of the
fan module with the connector on the motherboard.
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Page 99
Chapter 3 Maintaining the Server
FAN 05
FAN 04
FA N 0 3
FA N 0 2
FA N 01
CPU 1
CPU 2
SD1
SD2
Riser 2
Riser 1
305091
12
23
NoteThe arrow label on the top of the fan module, which indicates the direction of airflow, should
c. Press down gently on the fan module until the latch clicks and locks in place.
d. Repeat until you have moved all fan modules into the new fan cage.
Figure 3-27Fan Cage and Fan Modules
Installing or Replacing Server Components
point toward the rear of the server.
OL-32474-01
1Finger latches (on each fan module)3SuperCap power module position on
removable air baffle (air baffle not shown)
Step 9
Step 10Use the heatsink cleaning kit that comes with the conversion kit to cl ean the existing thermal grease from
Step 11Install the low-profile replacement heatsinks that come with the conversion kit:
2Fan cage plastic locking-levers
Remove the existing heatsink from each CPU.
a. Use a Number 2 Phillips-head screwdriv er to loosen the four capti v e screws that secure the heatsink.
NoteAlternate loosening each screw evenly to avoid damaging the heatsink or CPU.
b. Lift the heatsink off of the CPU and set it aside.
the top surface of each CPU.
a. Remove the protective tape from the pre-applied pad of thermal grease that is on the underside of
the new heatsink.
Cisco UCS C240 M4 Server Installation and Service Guide
3-57
Page 100
Installing or Replacing Server Components
305092
1
3
4
5
2
b. Align the four heatsink captive screws with the motherboard standoffs, and then use a Number 2
Phillips-head screwdriver to tighten the captive screws evenly.
NoteAlternate tightening each screw evenly to avoid damaging the heatsink or CPU.
Step 12Set the base of the replacement air baffle into the server (see Figure 3-28).
Figure 3-28Air Baffle Base
Chapter 3 Maintaining the Server
1Fan cage4GPU front support bracket latches
2Air baffle base5PCIe risers
Step 13
3Holder for RAID battery on air baffle
Install the NVIDIA K80 GPU card front support bracket to the GPU card (see Figure 3-29):
a. Remove the three thumbscrews from the front end of the GPU card.
b. Set the three holes in the GPU card front support bracket over the three screw holes.
c. Insert and tighten the three thumbscrews into the three scre w holes to secu re the front brack et to the
GPU card.
Cisco UCS C240 M4 Server Installation and Service Guide
3-58
OL-32474-01
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.