4 Installation Instructions
4.1 Choose Your Mounting Location
A good mounting location is important to getting the best performance out
of your MR30H access point. Keep the following in mind:
1. The device should have unobstructed line of sight to most coverage
areas. For example, if installing in an office filled with workspaces divided
by mid-height cubicle walls, installing on the ceiling or high on a wall would
be ideal.
2. Power over Ethernet supports a maximum cable length of 300 ft (100 m).
3. If being used in a mesh deployment, the MR30H should have line of
sight to at least two other Meraki devices. For more detailed instructions
regarding access point location selection, reference the Meraki Network
Design Guide (https://documentation.meraki.com/SM/Deployment_Guides).
4.2 Install the MR30H
For most mounting scenarios, the MR30H mount plate provides a quick,
simple, and flexible means of mounting your device. The installation should
be done in two steps. First, install the mount plate to your selected location.
Then attach the MR30H to the mount plate.
4.2.1 Attach the Mount Plate
The MR30H mount plate can be used to install your access point in a range
of scenarios, and has been designed to fit single-gang outlet boxes and
European outlet boxes.
4.2.2 Mount the MR30H
Insert the posts on the mount plate into the attachment slots on the access
point and hinge downward until locked.
4.2.2.1 Powering the MR30H with an 802.3at Power over
Ethernet Switch
Route Ethernet cable from a port on an active 802.3at PoE switch to the
Ethernet port in the bay of the MR30H.
The MR30H is Gigabit Ethernet-capable. To maximize device performance,
a Gigabit Ethernet-capable switch should be used.
4.3 Removing the Mount Plate from the Access Point