CipherLab 36662, 11662 User Manual



DOCVersion2.21 Thisdocumentisspecificallydesignedfortheusertoprinttwopagespersheetofpaperwithoptimal printquality.
Copyright © 2005~ 2008 CIPHERLAB CO., LTD. All rights reserved
The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited.
Due to continued product development this information may change without notice. The information and intellectual property contained herein is confidential between CIPHERLAB and the client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the documentation, please report them to us in writing. CIPHERLAB does not warrant that this document is error-free.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise without the prior written permission of CIPHERLAB CO., LTD.
For product consultancy and technical support, please contact your local sales representative. Also, you may visit our web site for more information.
The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.
Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation in the United States and/or other countries.
Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A.
Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
The editorial use of these names is for identification as well as to the benefit of the owners, with no intention of infringement.
CIPHERLAB CO., LTD.
Website:
http://www.cipherlab.com
VERSION DATE NOTES
RELEASE NOTES
2.21 Jan. 02, 2008 Larger setup barcodes
2.20 Nov. 30, 2007 New Word template applied
New: 3667 Bluetooth Cradle for 1166/1266
Modified: Auto-Sense mode supported on 1100 only.
New: Appendix III – Host Serial Commands
New: Appendix IV – Upgrading Firmware
2.15 Nov.13, 2006
2.14~
Nov. 06, 2006
Modified: Add notice for BT SPP and HID power saving – Please
disable power saving when connecting more than two 1x66 scanners to Bluetooth dongle.
New: Bluetooth HID supports Japanese keyboard.
2.12
2.11 Jan.27, 2006
2.10 Jan.18, 2006
Mar. 03, 2006
Modified: Typo errors corrected.
Modified: Bluetooth HID doesn’t support the following functions on
PDAs running Windows CE – Capital Lock Setting: Auto Detection, Digit Transmission: Numeric Key, and Alt Composing.
Modified: The default Capital Lock setting of Bluetooth HID is
changed from “Auto Detection” to “Capital Lock Off”.
New: Firmware version V4.20
2.00 Dec. 30, 2005
New: Bluetooth HID supported
New: Firmware version V4.10
1.00 Oct. 31, 2005 First release
CONTENTS
RELEASE NOTES .................................................................................................................................. 3
OVERVIEW..................................................
.......................................................................................... 1
BLUETOOTH SETTINGS (1166/1266)................................................................................................. 3
READER SETTINGS .............................................................................................................................. 9
OUTPUT INTERFACES......................................................................................................................... 13
Enter Configuration Mode................................................................................................................. 1
Exit Configuration Mode.................................................................................................................... 1
Update Settings............................................................................................................................ 1
Exit without Changes.................................................................................................................... 1
Restore Defaults................................................................................................................................ 1
List Current Settings.......................................................................................................................... 2
1.1 RF Auto Shutdown (Suspend mode) ......................................................................................... 3
1.2 Power Saving (Sniff Mode)......................................................................................................... 3
1.3 Transmit Buffer Setting .............................................................................................................. 3
1.4 Memory Mode............................................................................................................................. 3
1.4.1 Memory Mode .................................................................................................................... 3
1.4.2 Send Data........................................................................................................................... 4
1.4.3 Clear Data........................................................................................................................... 4
1.4.4 Memory Data Delay............................................................................................................ 4
1.5 Set Connection with 3666 ......................................................................................................... 5
1.6 Set Connection with 3667 or Generic Dongle .......................................................................... 5
1.6.1 Bluetooth Serial Port Parameters ..................................................................................... 5
1.6.2 Bluetooth HID Parameters................................................................................................. 6
2.1 Good Read Notification .............................................................................................................. 9
2.1.1 Buzzer Setting .................................................................................................................... 9
2.1.2 Buzzer Frequency............................................................................................................... 9
2.2 Read Redundancy ...................................................................................................................... 9
2.3 Scan Mode .................................................................................................................................. 9
2.4 Auto-Sense Mode (1100 only) .................................................................................................10
2.5 Scanner Time-Out .....................................................................................................................10
2.6 Delay between Re-read ............................................................................................................ 10
2.7 Negative Barcode Setting ........................................................................................................11
3.1 Keyboard Wedge Parameters.................................................................................................. 13
3.1.1 Activate and Select Keyboard Type................................................................................. 13
3.1.2 Alphabets Layout.............................................................................................................. 14
3.1.3 Digits Layout..................................................................................................................... 14
3.1.4 Capital Lock Type ............................................................................................................. 14
3.1.5 Capital Lock Setting .........................................................................................................14
3.1.6 Alphabets Transmission ..................................................................................................15
Scanner Configuration SmartScan Manual
SYMBOLOGY SETTINGS ..................................................................................................................... 21
DATA OUTPUT FORMAT...................................................................................................................... 43
3.1.7 Digits Transmission..........................................................................................................15
3.1.8 ALT Composing................................................................................................................. 15
3.1.9 Inter-Character Delay ....................................................................................................... 15
3.1.10 Laptop Support ..............................................................................................................15
3.2 RS-232 Parameters..................................................................................................................16
3.2.1 Activate RS-232 Interface ...............................................................................................16
3.2.2 Baud Rate......................................................................................................................... 16
3.2.3 Parity ................................................................................................................................. 16
3.2.4 Data Bits ........................................................................................................................... 17
3.2.5 Flow Control......................................................................................................................17
3.2.6 Inter-Character Delay ....................................................................................................... 17
3.3 WAND Emulation Parameters (1090+/1100/1105/1200) .................................................18
3.3.1 Activate Wand Emulation.................................................................................................18
3.3.2 Normal State ....................................................................................................................18
3.3.3 Bar State...........................................................................................................................18
3.3.4 Module Time.....................................................................................................................18
3.3.5 Margin Time...................................................................................................................... 19
4.1 Select Readable Barcodes.......................................................................................................21
4.2 Codabar Parameters ................................................................................................................25
4.3 Code 25 Parameters ................................................................................................................ 26
4.3.1 Industrial 25 .....................................................................................................................26
4.3.2 Interleaved 25 ..................................................................................................................27
4.3.3 Matrix 25 ..........................................................................................................................28
4.4 Code 39 Parameters ................................................................................................................ 30
4.5 Code 93 Parameters ................................................................................................................ 30
4.6 Code 128 Parameters..............................................................................................................30
4.7 EAN-8 Parameters .................................................................................................................... 31
4.8 EAN-13 Parameters.................................................................................................................. 32
4.9 EAN-128 Parameters................................................................................................................33
4.10 MSI Parameters...................................................................................................................... 34
4.11 Pharmacode Parameters....................................................................................................... 36
4.11.1 French Pharmacode ......................................................................................................36
4.11.2 Italian Pharmacode .......................................................................................................36
4.12 Plessey Parameters ...............................................................................................................37
4.13 RSS Family Parameters .........................................................................................................38
4.13.1 RSS-14............................................................................................................................ 38
4.13.2 RSS Limited....................................................................................................................38
4.13.3 RSS Expanded................................................................................................................ 39
4.14 Telepen Parameters...............................................................................................................40
4.15 UPC-A Parameters ..................................................................................................................41
4.16 UPC-E Parameters ..................................................................................................................42
5.1 Character Substitution ............................................................................................................. 43
5.2 Prefix/Suffix Setting..................................................................................................................43
Scanner Configuration SmartScan Manual
DATA EDITING .................................................................................................................................... 49
NUMERAL SYSTEMS ..........................................................................................................................57
KEYBOARD WEDGE TABLE & ASCII TABLE........................................................................................ 59
HOST SERIAL COMMANDS ................................................................................................................61
UPGRADING FIRMWARE .................................................................................................................... 63
5.3 Code ID Setting .........................................................................................................................43
5.3.1 Clear Code ID Settings..................................................................................................... 43
5.3.2 Select Pre-defined Code ID.............................................................................................. 44
5.3.3 Change Code ID................................................................................................................ 44
5.4 Length Code Setting .................................................................................................................45
6.1 Format Selection ......................................................................................................................49
6.1.1 Activate Editing Formats..................................................................................................49
6.1.2 Exclusive Data Editing...................................................................................................... 49
6.2 Editing Format Parameters ......................................................................................................50
6.2.1 Select Format to Configure.............................................................................................. 50
6.2.2 Restore Default Format ................................................................................................... 50
6.2.3 Define Data Criteria .........................................................................................................50
6.2.4 Divide Data into Fields.....................................................................................................52
6.2.5 Additional Fields............................................................................................................... 55
6.2.6 Field Transmission Sequence .........................................................................................56
Decimal System............................................................................................................................... 57
Hexadecimal System....................................................................................................................... 58
Keyboard Wedge Table ...................................................................................................................59
Key Type......................................................................................................................................59
Key Status ..................................................................................................................................60
ASCII Table.......................................................................................................................................60
Serial Commands............................................................................................................................ 61
Example ...........................................................................................................................................61
How to Upgrade 1166/1266 Firmware.........................................................................................63
Using 3666................................................................................................................................. 63
Using 3667 or Generic Dongle..................................................................................................64
How to Upgrade 3666 Firmware ....................................................................................................65
Find out Firmware Version of 3666 ..........................................................................................65
ENTER CONFIGURATION MODE
EXIT CONFIGURATION MODE
UPDATE SETTINGS
EXIT WITHOUT CHANGES
RESTORE DEFAULTS
OVERVIEW
Serial Command N/A
Enter Setup
Serial Command 9999
Update
Serial Command 9998
Abort
Serial Command 9993
Restore Defaults
Note: The default value (if there is) for each setting is included in a pair of angle brackets “<>”.
Update
1
Scanner Configuration SmartScan Manual
LIST CURRENT SETTINGS
Serial Command 9950
Page 1 Serial Command 9951
Page 2 Serial Command 9952
Page 3 Serial Command 9953
Page 4 Serial Command 9954
Page 5 Serial Command 9955
List settings regarding Interface, Buzzer, and Scanner Parameters
List settings regarding Prefix, Postfix, and Length Code Setting
List settings regarding Code ID
List settings regarding: Readable Symbologies
List settings regarding Symbology Parameters (1/3)
List settings regarding Symbology Parameters (2/3)
Page 6 Serial Command 9956
Page 7 Serial Command 9957
Page 8 Serial Command 9958
Page 9 Serial Command 9959
Page 10
List settings regarding Symbology Parameters (3/3)
List settings regarding Editing Format 1
List settings regarding Editing Format 2
List settings regarding Editing Format 3
2
Enter Setup
1.1 RF AUTO SHUTDOWN (SUSPEND MODE)
1.2 POWER SAVING (SNIFF MODE)
1.3 TRANSMIT BUFFER SETTING
1.4 MEMORY MODE
1.4.1 MEMORY MODE
Chapter 1
BLUETOOTH SETTINGS (1166/1266)
1) Read this label to specify the time interval before the scanner enters suspend mode.
2) Read the “Decimal Value suspend the connection with 3666 after being idle for 15 minutes.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0445
RF Auto Shutdown
” label on page 57. For example, read “1” and “5” for the scanner to
after … minutes
Serial Command 0458
<Enable> Disable
Serial Command 0459
Serial Command 0386
Serial Command 0387
Enable <Disable>
Serial Command 0321
Enable <Disable>
Serial Command 0320
Update
3
Scanner Configuration SmartScan Manual
1.4.2 SEND DATA
1.4.3 CLEAR DATA
1.4.4 MEMORY DATA DELAY
Serial Command 9918
Send Data
1) Read the “Clear Data” label to clear the flash memory.
2) Read the “Confirm” label to confirm the action.
Serial Command 9916
Clear Data Confirm
Serial Command 9917
Serial Command 0322
<None> 250 ms Serial Command 0324
500 ms 1 sec Serial Command 0326
2 sec 3 sec Serial Command 0328
Serial Command 0323
Serial Command 0325
Serial Command 0327
Serial Command 0329
5 sec 8 sec
4
Enter Setup
Chapter 1
1.5 SET CONNECTION WITH 3666
1.6 SET CONNECTION WITH 3667 OR GENERIC DONGLE
1.6.1 BLUETOOTH SERIAL PORT PARAMETERS
DEVICE NAME BROADCASTING
AUTHENTICATION
PIN CODE
Bluetooth Settings (1166/1266)
1) Read this label or the same one at the bottom of the 3666 cradle.
2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds.
3) Proceed to select a desired output interface.
Serial Command
Set Connection
Serial Command 0453
Activate Bluetooth SPP
Serial Command 0450
<Yes> No
Serial Command 0448
Yes <No>
1) Read this label to specify the PIN code.
2) Read the “Hexadecimal Value characters are allowed).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0452
” label on page 58 for the desired character string (max. 6
Serial Command 0451
Serial Command 0449
Enter PIN Code …
Update
5
Scanner Configuration SmartScan Manual
1.6.2 BLUETOOTH HID PARAMETERS
NO. KEYBOARD TYPE NO. KEYBOARD TYPE
RESET CONNECTION
DEVICE NAME BROADCASTING
AUTHENTICATION
1) Read this label to activate Bluetooth HID and select a keyboard type.
2) Read the “
Decimal Value
” label on page 57. Refer to the table below for the number of desired
keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0000
Activate & Select
Keyboard Type …
64 PCAT (US) 70 PCAT (UK)
65 PCAT (French) 71 PCAT (Belgium)
66 PCAT (German) 72 PCAT (Spanish)
67 PCAT (Italian) 73 PCAT (Portuguese)
68 PCAT (Swedish) 74 PS55 A01-2 (Japanese)
69 PCAT (Norwegian)
Read this label when switching connection from one PC to another and re-connection is required.
Serial Command 9972
Reset Connection
Serial Command 0450
Serial Command 0451
<Yes> No
Serial Command 0448
Serial Command 0449
Yes <No>
6
Enter Setup
PIN CODE
ALPHABETS LAYOUT
DIGITS LAYOUT
CAPITAL LOCK TYPE
1) Read this label to specify the PIN code.
Chapter 1
Bluetooth Settings (1166/1266)
2) Read the “Hexadecimal Value
” label on page 58 for the desired character string (max. 6
characters are allowed).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0452
Enter PIN Code …
Serial Command 0312
Serial Command 0313
<Default Layout> AZERTY Serial Command 0314
QWERTZ
Serial Command 0007
Serial Command 0008
<Default Layout> Upper Row Serial Command 0009
Lower Row
Serial Command 0010
Serial Command 0011
<Default> Shift Lock Serial Command 0012
Capital Lock
7
Update
Scanner Configuration SmartScan Manual
CAPITAL LOCK SETTING
ALPHABETS TRANSMISSION
DIGITS TRANSMISSION
ALT COMPOSING
Serial Command 0002
Serial Command 0003
Auto Detection Capital Lock ON Serial Command 0004
<Capital Lock OFF>
Serial Command 0005
Serial Command 0006
Ignore Case <Case-Sensitive>
Serial Command 0013
Serial Command 0014
Numeric Key <Alphanumeric
Key>
Serial Command 0335
Serial Command 0334
Yes <No>
8
Enter Setup
2.1 GOOD READ NOTIFICATION
2.1.1 BUZZER SETTING
2.1.2 BUZZER FREQUENCY
2.2 READ REDUNDANCY
2.3 SCAN MODE
Chapter 2
READER SETTINGS
Serial Command 0318
<Enable Buzzer> Disable Buzzer
Serial Command 0319
Serial Command 0046
8 kHz <4 kHz> Serial Command 0048
2 kHz 1 kHz
Serial Command 0047
Serial Command 0049
Serial Command 0201
Serial Command 0202
<No Redundancy> One Time Serial Command 0203
Two Times Three Times
Serial Command 0204
Serial Command 0066
<Auto Off Mode>
(Default for 1000/1090+)
Serial Command 0067
Continuous Mode
Update
9
Scanner Configuration SmartScan Manual
2.4 AUTO-SENSE MODE (1100 ONLY)
2.5 SCANNER TIME-OUT
2.6 DELAY BETWEEN RE-READ
Serial Command 0068
Auto Power Off Mode Alternate Mode Serial Command 0070
Momentary Mode Repeat Mode Serial Command 0072
<Laser Mode>
(Default for 1100/1105/1166/1200/1266)
Serial Command 0069
Serial Command 0071
Serial Command 0073
Test Mode
Serial Command 0333
Enable <Disable>
Serial Command 0332
1) Read this label to specify the time interval before the scan engine times out in Laser, Auto Off, or Auto Power Off mode.
2) Read the “Decimal Value automatically shut down after being idle for 10 seconds.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0207
Scanner Time-
” label on page 57. For example, read “1” and “0” for the scanner to
Out
after … seconds
Serial Command 0336
100 ms 200 ms
Serial Command 0337
10
Enter Setup
Chapter 2 Reader Settings
2.7 NEGATIVE BARCODE SETTING
Serial Command 0338
<400 ms> 800 ms Serial Command
0340
1 sec 2 sec Serial Command 0342
3 sec 5 sec
Serial Command 0339
Serial Command 0341
Serial Command 0343
Serial Command 0199
Enable <Disable>
Serial Command 0200
Update
11
Scanner Configuration SmartScan Manual
12
Enter Setup
3.1 KEYBOARD WEDGE PARAMETERS
3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE
NO. KEYBOARD TYPE NO. KEYBOARD TYPE
Chapter 3
OUTPUT INTERFACES
1) Read this label to activate Keyboard Wedge and select a keyboard type.
2) Read the “ keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0000
Activate & Select
1 PCAT (US) 15 PS55 001-81
2 PCAT (French) 16 PS55 001-2
3 PCAT (German) 17 PS55 001-82
4 PCAT (Italian) 18 PS55 001-3
5 PCAT (Swedish) 19 PS55 001-8A
6 PCAT (Norwegian) 20 PS55 002-1, 003-1
7 PCAT (UK) 21 PS55 002-81, 003-81
Decimal Value
” label on page 57. Refer to the table below for the number of desired
Keyboard Type …
8 PCAT (Belgium) 22 PS55 002-2, 003-2
9 PCAT (Spanish) 23 PS55 002-82, 003-82
10 PCAT (Portuguese) 24 PS55 002-3, 003-3
11 PS55 A01-1 25 PS55 002-8A, 003-8A
12 PS55 A01-2 (Japanese) 26 IBM 3477 Type 4 (Japanese)
13 PS55 A01-3 27 PS2-30
14 PS55 001-1 28 IBM 34XX/319X, Memorex Telex 122 Keys
13
Update
Scanner Configuration SmartScan Manual
3.1.2 ALPHABETS LAYOUT
3.1.3 DIGITS LAYOUT
3.1.4 CAPITAL LOCK TYPE
3.1.5 CAPITAL LOCK SETTING
Serial Command 0312
<Default Layout> AZERTY Serial Command 0314
QWERTZ
Serial Command 0313
Serial Command 0007
<Default Layout> Upper Row Serial Command 0009
Lower Row
Serial Command 0008
Serial Command 0010
<Default> Shift Lock Serial Command 0012
Capital Lock
Serial Command 0011
Serial Command 0002
Auto Detection Capital Lock ON Serial Command 0004
<Capital Lock OFF>
Serial Command 0003
14
Enter Setup
3.1.6 ALPHABETS TRANSMISSION
3.1.7 DIGITS TRANSMISSION
3.1.8 ALT COMPOSING
3.1.9 INTER-CHARACTER DELAY
3.1.10 LAPTOP SUPPORT
Chapter 3 Output Interfaces
Serial Command 0005
Ignore Case <Case-Sensitive>
Serial Command 0006
Serial Command 0013
Numeric Key <Alphanumeric
Serial Command 0014
Key>
Serial Command 0335
Yes <No>
Serial Command 0334
1) Read this label to specify the inter-character delay.
2) Read the “
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0015
Inter-Character
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
Delay …
Serial Command 0389
Enable <Disable>
Serial Command 0388
Update
15
Scanner Configuration SmartScan Manual
3.2 RS-232 PARAMETERS
3.2.1 ACTIVATE RS-232 INTERFACE
3.2.2 BAUD RATE
3.2.3 PARITY
Serial Command 0001
Activate RS-232
Interface
Serial Command 0023
115200 bps 38400 bps Serial Command 0017
19200 bps <9600 bps> Serial Command 0019
4800 bps 2400 bps Serial Command 0021
1200 bps 600 bps
Serial Command 0016
Serial Command 0018
Serial Command 0020
Serial Command 0022
(for 1200 only)
Serial Command 0028
Serial Command 0029
<No Parity> Even Serial Command 0030
Odd
16
Enter Setup
3.2.4 DATA BITS
3.2.5 FLOW CONTROL
3.2.6 INTER-CHARACTER DELAY
Chapter 3 Output Interfaces
Serial Command 0034
<8 bits> 7 bits
Serial Command 0035
Serial Command 0042
<None> Scanner Ready Serial Command 0044
Data Ready Invert Data Ready
Serial Command 0043
Serial Command 0045
1) Read this label to specify the inter-character delay.
2) Read the “
3) Read the “Validate” label on the same page to complete this setting.
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
Serial Command 0015
Inter-Character
Delay …
Update
17
Scanner Configuration SmartScan Manual
3.3 WAND EMULATION PARAMETERS (1090+/1100/1105/1200)
3.3.1 ACTIVATE WAND EMULATION
3.3.2 NORMAL STATE
3.3.3 BAR STATE
3.3.4 MODULE TIME
Serial Command 0306
Activate Wand
Emulation
Serial Command 0302
High <Low>
Serial Command 0303
Serial Command 0304
<High> Low
Serial Command 0305
Serial Command 0362
250 μs 500 μs
Serial Command 0364
Serial Command 0363
Serial Command 0365
<1 ms> 1.5 ms Serial Command 0366
2 ms 3 ms Serial Command 0368
4 ms 5 ms
Serial Command 0367
Serial Command 0369
18
Enter Setup
3.3.5 MARGIN TIME
Chapter 3 Output Interfaces
Serial Command 0370
5 ms 10 ms Serial Command 0372
<20 ms> 30 ms Serial Command 0374
40 ms 60 ms Serial Command 0376
80 ms 100 ms
Serial Command 0371
Serial Command 0373
Serial Command 0375
Serial Command 0377
Update
19
Scanner Configuration SmartScan Manual
20
Enter Setup
4.1 SELECT READABLE BARCODES
CODABAR
CODE 39
CODE 93
CODE 128
EAN-128
EAN-13
Chapter 4
SYMBOLOGY SETTINGS
Serial Command 0086
<Enable> Disable
Serial Command 0074
<Enable> Disable
Serial Command 0088
Serial Command 0087
Serial Command 0075
Serial Command 0089
<Enable> Disable
Serial Command 0090
<Enable> Disable
Serial Command 0104
Enable <Disable>
Serial Command 0106
<Enable No Addon> Disable No Addon
Serial Command 0091
Serial Command 0105
Serial Command 0107
Update
21
Scanner Configuration SmartScan Manual
EAN-8
FRENCH PHARMACODE
ITALIAN PHARMACODE
INDUSTRIAL 25
Serial Command 0108
Serial Command 0109
Enable Addon 2 <Disable Addon 2> Serial Command 0110
Serial Command 0111
Enable Addon 5 <Disable Addon 5>
Serial Command 0098
Serial Command 0099
<Enable No Addon> Disable No Addon Serial Command 0100
Serial Command 0101
Enable Addon 2 <Disable Addon 2> Serial Command 0102
Serial Command 0103
Enable Addon 5 <Disable Addon 5>
Serial Command 0078
Serial Command 0079
Enable <Disable>
Serial Command 0076
Serial Command 0077
Enable <Disable>
Serial Command 0080
Serial Command 0081
<Enable> Disable
22
Enter Setup
Chapter 4 Symbology Settings
INTERLEAVED 25
MATRIX 25
MSI
PLESSEY
RSS-14 & EXPANDED
RSS LIMITED
TELEPEN
Serial Command 0082
Serial Command 0083
<Enable> Disable
Serial Command 0084
Serial Command 0085
Enable <Disable>
Serial Command 0112
Serial Command 0113
Enable <Disable>
Serial Command 0114
Serial Command 0115
Enable <Disable>
Serial Command 0412
Enable RSS-14 & RSS
Serial Command 413
<Disable Both>
Expanded
Serial Command 0414
Serial Command 0415
Enable <Disable>
Serial Command 0436
Serial Command 0437
Enable <Disable>
Update
23
Scanner Configuration SmartScan Manual
UPC-A
UPC-E
Serial Command 0291
Serial Command 0292
<Enable No Addon> Disable No Addon Serial Command 0293
Serial Command 0294
Enable Addon 2 <Disable Addon 2> Serial Command 0295
Serial Command 0296
Enable Addon 5 <Disable Addon 5>
Serial Command 0092
Serial Command 0093
<Enable No Addon> Disable No Addon Serial Command 0094
Serial Command 0095
Enable Addon 2 <Disable Addon 2> Serial Command 0096
Serial Command 0097
Enable Addon 5 <Disable Addon 5>
24
Enter Setup
4.2 CODABAR PARAMETERS
START / STOP CHARACTERS SELECTION
START / STOP TRANSMISSION
CLSI CONVERSION
Chapter 4 Symbology Settings
Serial Command 0086
Serial Command 0087
<Enable> Disable
Serial Command 0151
Serial Command 0152
<abcd/abcd> abcd/tn*e Serial Command 0153
Serial Command 0154
ABCD/ABCD ABCD/TN*E
Serial Command 0155
Serial Command 0156
Enable <Disable>
Serial Command 0157
Serial Command 0158
Enable <Disable>
Update
25
Scanner Configuration SmartScan Manual
4.3 CODE 25 PARAMETERS
4.3.1 INDUSTRIAL 25
START / STOP PATTERN SELECTION
CHECKSUM VERIFICATION
CHECKSUM TRANSMISSION
CODE LENGTH QUALIFICATION
Serial Command 0080
Serial Command 0081
<Enable> Disable
Serial Command 0130
Serial Command 0131
<Industrial 25> Interleaved 25 Serial Command 0132
Matrix 25
Serial Command 0139
Serial Command 0140
Enable <Disable>
Serial Command 0141
Serial Command 0142
<Enable> Disable
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command 0208
Enable Max./Min. Length …
26
Enter Setup
Chapter 4 Symbology Settings
4.3.2 INTERLEAVED 25
START / STOP PATTERN SELECTION
CHECKSUM VERIFICATION
CHECKSUM TRANSMISSION
Serial Command 0210
Serial Command 0211
Max. Length Min. Length
Serial Command 0209
Enable Fixed Length … Serial Command 0210
Serial Command 0211
Fixed Length 1 Fixed Length 2
Serial Command 0082
<Enable> Disable
Serial Command 0083
Serial Command 0133
Serial Command 0134
Industrial 25 <Interleaved 25> Serial Command 0135
Matrix 25
Serial Command 0143
Serial Command 0144
Enable <Disable>
Serial Command 0145
Serial Command 0146
<Enable> Disable
Update
27
Scanner Configuration SmartScan Manual
CODE LENGTH QUALIFICATION
4.3.3 MATRIX 25
START / STOP PATTERN SELECTION
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “
4) Read the “Validate” label on the same page to complete this setting.
Serial Command 0212
Enable Max./Min. Length … Serial Command 0214
Max. Length Min. Length
Serial Command 0213
Enable Fixed Length … Serial Command 0214
Fixed Length 1 Fixed Length 2
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
Serial Command 0215
Serial Command 0215
Serial Command 0084
Enable <Disable>
Serial Command 0136
Industrial 25 Interleaved 25 Serial Command 0138
<Matrix 25>
Serial Command 0085
Serial Command 0137
28
Enter Setup
Chapter 4 Symbology Settings
CHECKSUM VERIFICATION
CHECKSUM TRANSMISSION
CODE LENGTH QUALIFICATION
Serial Command 0147
Serial Command 0148
Enable <Disable>
Serial Command 0149
Serial Command 0150
<Enable> Disable
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command 0216
Enable Max./Min. Length … Serial Command 0218
Serial Command 0219
Max. Length Min. Length
Serial Command 0217
Enable Fixed Length … Serial Command 0218
Serial Command 0219
Fixed Length 1 Fixed Length 2
Update
29
Scanner Configuration SmartScan Manual
4.4 CODE 39 PARAMETERS
START / STOP TRANSMISSION
CHECKSUM VERIFICATION
CHECKSUM TRANSMISSION
STANDARD / FULL ASCII CODE 39
4.5 CODE 93 PARAMETERS
4.6 CODE 128 PARAMETERS
Serial Command 0074
<Enable> Disable
Serial Command 0116
Enable <Disable>
Serial Command 0118
Enable <Disable>
Serial Command 0120
Serial Command 0075
Serial Command 0117
Serial Command 0119
Serial Command 0121
<Enable> Disable
Serial Command 0122
Full ASCII <Standard>
Serial Command 0123
Serial Command 0088
<Enable> Disable
Serial Command 0089
Serial Command 0090
<Enable> Disable
Serial Command 0091
30
Enter Setup
4.7 EAN-8 PARAMETERS
CONVERT TO EAN-13
CHECKSUM TRANSMISSION
Chapter 4 Symbology Settings
Serial Command 0098
<Enable No Addon> Disable No Addon Serial Command 0100
Enable Addon 2 <Disable Addon 2> Serial Command 0102
Enable Addon 5 <Disable Addon 5>
Serial Command 0195
Enable <Disable>
Serial Command 0187
Serial Command 0099
Serial Command 0101
Serial Command 0103
Serial Command 0196
Serial Command 0188
<Enable> Disable
Update
31
Scanner Configuration SmartScan Manual
4.8 EAN-13 PARAMETERS
ISBN CONVERSION
ISSN CONVERSION
CHECKSUM TRANSMISSION
Serial Command 0106
Serial Command 0107
<Enable No Addon> Disable No Addon Serial Command 0108
Serial Command 0109
Enable Addon 2 <Disable Addon 2> Serial Command 0110
Serial Command 0111
Enable Addon 5 <Disable Addon 5>
Serial Command 0179
Serial Command 0180
Enable <Disable>
Serial Command 0181
Serial Command 0182
Enable <Disable>
Serial Command 0189
Serial Command 0190
<Enable> Disable
32
Enter Setup
4.9 EAN-128 PARAMETERS
CODE ID TRANSMISSION
FIELD SEPARATOR
Chapter 4 Symbology Settings
Serial Command 0104
Enable <Disable>
Serial Command 0434
Enable <Disable>
Serial Command 0301
Enable Field Separator …
1) Read this label to enable field separator.
2) Read the “
3) Read the “Validate” label on the same page to complete this setting.
Hexadecimal Value
” label on page 58 for the desired character string.
Serial Command 0105
Serial Command 0435
Update
33
Scanner Configuration SmartScan Manual
4.10 MSI PARAMETERS
CHECKSUM VERIFICATION
CHECKSUM TRANSMISSION
CODE LENGTH QUALIFICATION
Serial Command 0112
Serial Command 0113
Enable <Disable>
Serial Command 0167
Serial Command 0168
<Single Modulo 10> Double Modulo 10 Serial Command 0169
Modulo 10 & 11
Serial Command 0170
<Last Digit Not
Transmitted>
Serial Command 0171
Both Digits
Transmitted Serial Command 0172
Both Digits Not
Transmitted
1) Read the label to enable either Max. /Min. length qualification or fixed length qualification.
2) Read the labels for Max. /Min or fixed length separately.
3) Read the “
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
4) Read the “Validate” label on the same page to complete this setting.
Serial Command 0220
Enable Max./Min. Length …
34
Enter Setup
Chapter 4 Symbology Settings
Serial Command 0222
Max. Length Min. Length
Serial Command 0221
Enable Fixed Length … Serial Command 0222
Fixed Length 1 Fixed Length 2
Serial Command 0223
Serial Command 0223
Update
35
Scanner Configuration SmartScan Manual
4.11 PHARMACODE PARAMETERS
4.11.1 FRENCH PHARMACODE
CHECKSUM TRANSMISSION
4.11.2 ITALIAN PHARMACODE
CHECKSUM TRANSMISSION
Serial Command 0078
Enable <Disable>
Serial Command 0128
<Enable> Disable
Serial Command 0079
Serial Command 0129
Serial Command 0076
Enable <Disable>
Serial Command 0126
Serial Command 0077
Serial Command 0127
<Enable> Disable
36
Enter Setup
4.12 PLESSEY PARAMETERS
CONVERT TO UK PLESSEY
CHECKSUM TRANSMISSION
Chapter 4 Symbology Settings
Serial Command 0114
Enable <Disable>
Serial Command 0165
Enable <Disable>
Serial Command 0163
<Enable> Disable
Serial Command 0115
Serial Command 0166
Serial Command 0164
Update
37
Scanner Configuration SmartScan Manual
4.13 RSS FAMILY PARAMETERS
CODE ID SELECTION
4.13.1 RSS-14
CODE ID TRANSMISSION
APPLICATION ID TRANSMISSION
CHECKSUM TRANSMISSION
4.13.2 RSS LIMITED
Serial Command 0432
]C1 <]e0>
Serial Command 0433
Serial Command 0412
Enable RSS-14 & RSS
Expanded
Serial Command 0418
<Enable> Disable
Serial Command 0424
<Enable> Disable
Serial Command 0428
Serial Command 413
<Disable Both>
Serial Command 0419
Serial Command 0425
Serial Command 0429
<Enable> Disable
Serial Command 0414
Enable <Disable>
Serial Command 0415
38
Enter Setup
Chapter 4 Symbology Settings
CODE ID TRANSMISSION
APPLICATION ID TRANSMISSION
CHECKSUM TRANSMISSION
4.13.3 RSS EXPANDED
CODE ID TRANSMISSION
Serial Command 0420
Serial Command 0421
<Enable> Disable
Serial Command 0426
Serial Command 0427
<Enable> Disable
Serial Command 0430
Serial Command 0431
<Enable> Disable
Serial Command 0412
Enable RSS-14 & RSS
Expanded
Serial Command 0422
<Enable> Disable
Serial Command 413
<Disable Both>
Serial Command 0423
Update
39
Scanner Configuration SmartScan Manual
4.14 TELEPEN PARAMETERS
TELEPEN OUTPUT
APPLY ALL 3 EDITING FORMATS
Serial Command 0436
Enable <Disable>
Serial Command 0440
Original Telepen
(Numeric)
Serial Command 0443
<Apply All to Telepen> Disable All
Serial Command 0437
Serial Command 0441
<AIM Telepen>
Serial Command 0444
40
Enter Setup
4.15 UPC-A PARAMETERS
CONVERT TO EAN-13
SYSTEM NUMBER TRANSMISSION
CHECKSUM TRANSMISSION
Chapter 4 Symbology Settings
Serial Command 0291
Serial Command 0292
<Enable No Addon> Disable No Addon Serial Command 0293
Serial Command 0294
Enable Addon 2 <Disable Addon 2> Serial Command 0295
Serial Command 0296
Enable Addon 5 <Disable Addon 5>
Serial Command 0177
Serial Command 0178
<Enable> Disable
Serial Command 0193
Serial Command 0194
<Enable> Disable
Serial Command 0185
Serial Command 0186
<Enable> Disable
Update
41
Scanner Configuration SmartScan Manual
4.16 UPC-E PARAMETERS
SYSTEM NUMBER SELECTION
CONVERT TO UPC-A
SYSTEM NUMBER TRANSMISSION
CHECKSUM TRANSMISSION
Serial Command 0092
Serial Command 0093
<Enable No Addon> Disable No Addon Serial Command 0094
Serial Command 0095
Enable Addon 2 <Disable Addon 2> Serial Command 0096
Serial Command 0097
Enable Addon 5 <Disable Addon 5>
Serial Command 0287
System Number 0 & 1
Serial Command 0288
<System Number 0
Only>
Serial Command 0175
Serial Command 0176
Enable <Disable>
Serial Command 0191
Serial Command 0192
Enable <Disable>
Serial Command 0183
Serial Command 0184
<Enable> Disable
42
Enter Setup
5.1 CHARACTER SUBSTITUTION
5.2 PREFIX/SUFFIX SETTING
5.3 CODE ID SETTING
5.3.1 CLEAR CODE ID SETTINGS
Chapter 5
DATA OUTPUT FORMAT
1) Read the label to enable either character substitution by set.
2) Read the “Hexadecimal Value
read “3”, “0”, “2” and “D” for the scanner to replace the character [0] with a dash [-].
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0309
Set 1 Set 2 Serial Command
0311
Set 3
” label on page 58 for the desired character string. For example,
Serial Command 0310
1) Read the label to apply prefix code or suffix code separately.
2) Read the “
read “2” and “B” for the scanner to prefix or suffix the character [+].
3) Read the “Validate” label on the same page to complete this setting.
Hexadecimal Value
” label on page 58 for the desired character string. For example,
Serial Command 0273
Prefix Code Suffix Code
Serial Command 0274
Serial Command 9960
Clear All Code ID
Settings
Update
43
Scanner Configuration SmartScan Manual
5.3.2 SELECT PRE-DEFINED CODE ID
5.3.3 CHANGE CODE ID
Serial Command 9961
Code ID Set 1 Code ID Set 2 Serial Command 9963
Code ID Set 3 Code ID Set 4 Serial Command 9965
Code ID Set 5
Serial Command 9962
Serial Command 9964
1) Read the label of a specific symbology to change its code ID.
2) Read the “
read “4” and “4” for applying the character [D] for Code ID.
3) Read the “Validate” label on the same page to complete this setting.
Hexadecimal Value
” label on page 58 for the desired character string. For example,
Serial Command 0262
Codabar Code 39 Serial Command 0263
Code 93 Code 128 Serial Command 0266
EAN-8 EAN-13 Serial Command 0258
French Pharmacode Italian Pharmacode Serial Command 0259
Industrial 25 Interleaved 25
Serial Command 0256
Serial Command 0264
Serial Command 0267
Serial Command 0257
Serial Command 0260
44
Enter Setup
Chapter 5 Data Output Format
5.4 LENGTH CODE SETTING
CODABAR
CODE 39
CODE 93
CODE 128
EAN-128 & RSS FAMILY
Serial Command 0261
Serial Command 0268
Matrix 25 MSI Serial Command 0269
Serial Command 0442
Plessey Telepen Serial Command 0270
Serial Command 0265
UPC-A UPC-E
Serial Command 0236
Enable Length Code <Disable Length Code>
Serial Command 0237
Serial Command 0224
Serial Command 0225
Enable Length Code <Disable Length Code>
Serial Command 0238
Serial Command 0239
Enable Length Code <Disable Length Code>
Serial Command 0240
Serial Command 0241
Enable Length Code <Disable Length Code>
Serial Command 0299
Serial Command 0300
Enable Length Code <Disable Length Code>
45
Update
Scanner Configuration SmartScan Manual
EAN-8
EAN-13
FRENCH PHARMACODE
ITALIAN PHARMACODE
INDUSTRIAL 25
INTERLEAVED 25
MATRIX 25
Serial Command 0244
Serial Command 0245
Enable Length Code <Disable Length Code>
Serial Command 0246
Serial Command 0247
Enable Length Code <Disable Length Code>
Serial Command 0228
Serial Command 0229
Enable Length Code <Disable Length Code>
Serial Command 0226
Serial Command 0227
Enable Length Code <Disable Length Code>
Serial Command 0230
Serial Command 0231
Enable Length Code <Disable Length Code>
Serial Command 0232
Serial Command 0233
Enable Length Code <Disable Length Code>
Serial Command 0234
Serial Command 0235
Enable Length Code <Disable Length Code>
46
Enter Setup
Chapter 5 Data Output Format
MSI
PLESSEY
TELEPEN
UPC-A
UPC-E
Serial Command 0248
Serial Command 0249
Enable Length Code <Disable Length Code>
Serial Command 0250
Serial Command 0251
Enable Length Code <Disable Length Code>
Serial Command 0438
Serial Command 0439
Enable Length Code <Disable Length Code>
Serial Command 0289
Serial Command 0290
Enable Length Code <Disable Length Code>
Serial Command 0242
Serial Command 0243
Enable Length Code <Disable Length Code>
Update
47
Scanner Configuration SmartScan Manual
48
Enter Setup
6.1 FORMAT SELECTION
6.1.1 ACTIVATE EDITING FORMATS
FORMAT 1
FORMAT 2
FORMAT 3
APPLY ALL 3 EDITING FORMATS TO TELEPEN
6.1.2 EXCLUSIVE DATA EDITING
Chapter 6
DATA EDITING
Serial Command 0281
Enable Editing Format 1 <Disable
Serial Command 0283
Serial Command 0282
Editing Format 1>
Serial Command 0284
Enable Editing Format 2 <Disable
Editing Format 2>
Serial Command 0285
Enable Editing Format 3 <Disable
Serial Command 0443
<Apply All to Telepen> Disable All
Serial Command 0286
Editing Format 3>
Serial Command 0444
Serial Command 0279
Reject Non-conforming Data <Normal>
Serial Command 0280
Update
49
Scanner Configuration SmartScan Manual
6.2 EDITING FORMAT PARAMETERS
6.2.1 SELECT FORMAT TO CONFIGURE
START FORMAT PROGRAMMING
END FORMAT PROGRAMMING
6.2.2 RESTORE DEFAULT FORMAT
6.2.3 DEFINE DATA CRITERIA
APPLICABLE CODE TYPE
Serial Command 9981
Configure Format 1 Configure Format 2 Serial Command 9983
Configure Format 3
Serial Command 9980
Serial Command 9982
End Format Programming
Serial Command 9990
Restore Default Format
Serial Command 9992
<Apply to All Code Types> Clear All Serial Command 0512
Codabar Code 39 Serial Command 0514
Serial Command 9991
Serial Command 0500
Serial Command 0516
Code 93 Code 128
50
End Format Programming
Chapter 6 Data Editin
g
DATA LENGTH
Serial Command 0524
EAN-8 No Addon EAN-8 Addon 2 Serial Command 0528
EAN-8 Addon 5 EAN-13 No Addon Serial Command 0534
EAN-13 Addon 2 EAN-13 Addon 5 Serial Command 0590
EAN-128 / RSS French Pharmacode Serial Command 0502
Italian Pharmacode Industrial 25 Serial Command 0508
Serial Command 0526
Serial Command 0532
Serial Command 0536
Serial Command 0504
Serial Command 0506
Serial Command 0510
Interleaved 25 Matrix 25 Serial Command 0538
MSI Plessey Serial Command 0584
UPC-A No Addon UPC-A Addon 2 Serial Command 0588
UPC-A Addon 5 UPC-E No Addon Serial Command 0520
UPC-E Addon 2 UPC-E Addon 5
1) Read the labels for Max. /Min length separately.
Serial Command 0540
Serial Command 0586
Serial Command 0518
Serial Command 0522
51
Update
Scanner Configuration SmartScan Manual
MATCHING STRING
LOCATION OF MATCHING STRING
6.2.4 DIVIDE DATA INTO FIELDS
TOTAL NUMBER OF FIELDS
2) Read the “Decimal Value
” label on page 57 for the desired length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0548
Serial Command 0549
Max. Length Min. Length
1) Read the label to specify a matching string.
2) Read the “
Hexadecimal Value
” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0550
Matching String …
1) Read the label to specify the location of the matching string.
2) Read the “Decimal Value
” label on page 57 for the desired location.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0551
Location of Matching String …
Serial Command 0578
<One Field> Two Fields Serial Command 0580
Three Fields Four Fields Serial Command 0582
Serial Command 0579
Serial Command 0581
Serial Command 0583
Five Fields Six Fields
52
End Format Programming
g
FIELD 1 SETTING
FIELD 2 SETTING
1) Read the label to divide field by a specified terminating string.
Chapter 6 Data Editin
2) Read the “Hexadecimal Value
” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0555
Select Field Terminating String … Serial Command 0552
Serial Command 0553
Include String Discard String
1) Read the label to divide field by field length.
2) Read the “Decimal Value
” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0554
Divide Field by Field Length …
1) Read the label to divide field by a specified terminating string.
2) Read the “
Hexadecimal Value
” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0559
Select Field Terminating String … Serial Command 0556
Serial Command 0557
Include String Discard String
1) Read the label to divide field by field length.
2) Read the “
Decimal Value
” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
53
Update
Scanner Configuration SmartScan Manual
FIELD 3 SETTING
FIELD 4 SETTING
Serial Command 0558
Divide Field by Field Length …
1) Read the label to divide field by a specified terminating string.
2) Read the “
Hexadecimal Value
” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0563
Select Field Terminating String … Serial Command 0560
Serial Command 0561
Include String Discard String
1) Read the label to divide field by field length.
2) Read the the “
Decimal Value
” label on page 57 for the desired field length.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0562
Divide Field by Field Length …
1) Read the label to divide field by a specified terminating string.
2) Read the “Hexadecimal Value
” label on page 58 for the desired character string.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0567
Select Field Terminating String … Serial Command 0564
Serial Command 0565
Include String Discard String
1) Read the label to divide field by field length.
2) Read the “
Decimal Value
” label on page 57 for the desired field length.
54
End Format Programming
Chapter 6 Data Editin
g
FIELD 5 SETTING
6.2.5 ADDITIONAL FIELDS
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0566
Divide Field by Field Length …
1) Read the label to divide field by a specified terminating string.
2) Read the “
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0571
Select Field Terminating String … Serial Command 0568
Include String Discard String
1) Read the label to divide field by field length.
2) Read the “Decimal Value
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0570
Divide Field by Field Length …
Hexadecimal Value
” label on page 58 for the desired character string.
Serial Command 0569
” label on page 57 for the desired field length.
1) Read the label to specify an additional field, one at a time.
2) Read the “Hexadecimal Value
3) Read the “Validate” label on the same page to complete this setting.
Serial Command 0572
Additional Field 1… Additional Field 2… Serial Command 0574
Additional Field 3… Additional Field 4…
” label on page 58 for the desired additional field.
Serial Command 0573
Serial Command 0575
55
Update
Scanner Configuration SmartScan Manual
6.2.6 FIELD TRANSMISSION SEQUENCE
Serial Command 0576
Additional Field 5…
1) Read the “Start” label to begin with programming the field transmission sequence.
2) Program the transmission sequence by reading the desired fields as well as additional fields.
3) Read the “End” label on the same page to complete this setting.
Serial Command 0577
Start (Programming) …
Serial Command 9901
Field 1 Field 2 Serial Command 9903
Field 3 Field 4 Serial Command 9905
Field 5 Field 6 Serial Command 9907
Additional Field 1 Additional Field 2 Serial Command 9909
Additional Field 3 Additional Field 4 Serial Command 9911
Serial Command 9902
Serial Command 9904
Serial Command 9906
Serial Command 9908
Serial Command 9910
Additional Field 5
Serial Command 9994
End (Programming)
56
End Format Programming
DECIMAL SYSTEM
DECIMAL
VALIDATE THE VALUES
Appendix I
NUMERAL SYSTEMS
Serial Command 9900
0 1 Serial Command 9902
2 3 Serial Command 9904
4 5 Serial Command 9906
Serial Command 9901
Serial Command 9903
Serial Command 9905
Serial Command 9907
6 7 Serial Command 9908
8 9
Serial Command 9994
Validate
Serial Command 9909
Update
57
Scanner Configuration SmartScan Manual
HEXADECIMAL SYSTEM
HEXADECIMAL
VALIDATE THE VALUES
Serial Command 9900
0 1 Serial Command 9902
2 3 Serial Command 9904
4 5 Serial Command 9906
Serial Command 9901
Serial Command 9903
Serial Command 9905
Serial Command 9907
6 7 Serial Command 9908
8 9 Serial Command 9910
A B Serial Command 9912
C D Serial Command 9914
E F
Serial Command 9994
Serial Command 9909
Serial Command 9911
Serial Command 9913
Serial Command 9915
Validate
58
Enter Setup
KEYBOARD WEDGE TABLE
KEY TYPE
Appendix II
KEYBOARD WEDGE TABLE & ASCII TABLE
0 12345678
0 F2 SP 0 @ P ` p
1 INS F3 ! 1 A Q a q
2 DLT F4 " 2 B R b r
3 Home F5 # 3 C S c s
4 End F6 $ 4 D T d t
5 Up F7 % 5 E U e u
6 Down F8 & 6 F V f v
7 Left F9 ' 7 G W g w
8 BS F10 ( 8 H X h x
9 HT F11 ) 9 I Y i y
A LF F12 * : J Z j z
B Right ESC + ; K [ k {
C PgUp Exec , < L \ l |
D CR CR* - = M ] m }
E PgDn . > N ^ n ~
b
c
d
e
f
g
h
i
j
k
F F1 / ? O _ o Dly ENTER*
Note: (1) b~k: Digits of numeric keypad.
(2) CR*/Send/ENTER*: ENTER key on the numeric keypad.
Serial Command 9926
<Normal> Scan Code
Note: If "Keyboard Wedge" is configured for interface, Key Type and Key Status will then become
applicable.
Serial Command 9936
59
Scanner Configuration SmartScan Manual
KEY STATUS
ASCII TABLE
Serial Command 9930
Add Shift Add Left Ctrl Serial Command 9932
Add Left Alt Add Right Ctrl Serial Command 9934
Add Right Alt
Note: Decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.
Serial Command 9931
Serial Command 9933
0 1234567
0 DLE SP 0 @ P ` p
1 SOH DC1 ! 1 A Q a q
2 STX DC2 " 2 B R b r
3 ETX DC3 # 3 C S c s
4 EOT DC4 $ 4 D T d t
5 ENQ NAK % 5 E U e u
6 ACK SYN & 6 F V f v
7 BEL ETB ' 7 G W g w
8 BS CAN ( 8 H X h x
9 HT EM ) 9 I Y i y
A LF SUB * : J Z j z
B VT ESC + ; K [ k {
C FF FS , < L \ l |
D CR GS - = M ] m }
E SO RS . > N ^ n ~
F SI US / ? O _ o DEL
60
SERIAL COMMANDS
#@nnnn<CR>
#@ - - - -<CR>
#@ . . . . <CR>
#@////<CR>
EXAMPLE
Appendix III
HOST SERIAL COMMANDS
Purpose To configure the scanner.
Remarks nnnn – the four digits of command parameters. For example, “9952” is to list the
current Code ID settings.
“0x23” + “0x40” + “0x39” + “0x39” + “0x35” + “0x32” + “0x0d”
Purpose To halt the scanner.
Remarks “0x23” + “0x40” + “0x2d” + “0x2d” + “0x2d” + “0x2d” + “0x0d”
Purpose To resume operation.
Remarks “0x23” + “0x40” + “0x2e” + “0x2e” + “0x2e” + “0x2e” + “0x0d”
Purpose To respond with a beep.
Remarks “0x23” + “0x40” + “0x2f” + “0x2f” + “0x2f” + “0x2f” + “0x0d”
Send the serial commands via RS-232 interface or Bluetooth SPP. For example, run HyperTerminal on the host computer.
For the scanner to change the buzzer frequency to 2 kHz and beep –
#@0048<CR>
#@////<CR>
For the scanner to change the buzzer frequency to 8 kHz and beep –
#@0046<CR>
#@////<CR>
61
Scanner Configuration SmartScan Manual
For the scanner to change the buzzer frequency to 4 kHz and beep –
#@0047<CR>
#@////<CR>
For the scanner to change the buzzer frequency to 1 kHz and beep –
#@0049<CR>
#@////<CR>
62
HOW TO UPGRADE 1166/1266 FIRMWARE
USING 3666
Appendix IV
UPGRADING FIRMWARE
You can only upgrade firmware of one scanner at a time. You must remove the battery of each of the rest scanners when there is more than one scanner connected to your computer, either via (1) the 3666 cradle or (2) the 3667 cradle or any generic Bluetooth dongle.
Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with a
fully charged battery.
1) Connect the power supply cord from the 3666 cradle to a proper power outlet.
2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port.
3) Refer to section 1.5 for the target scanner to set connection with the 3666 cradle.
Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds.
Both labels can be located at the bottom of the cradle.
4) Read the following labels in sequence to configure the scanner to use RS-232 as output interface.
Enter Setup
Activate RS-232 Interface
115200 bps
Update
5) Read the following labels in sequence for the scanner to enter the download mode.
The scanner will respond with beeps to indicate it is ready for downloading.
63
Scanner Configuration SmartScan Manual
USING 3667 OR GENERIC DONGLE
Enter Setup
Download
6) Run the download utility “ProLoad.exe” or “Download.exe” on your computer.
(Download.exe requires version 2.3 or later!)
Open the firmware update “1x66-xx.shx”, and select the correct COM port.
Baud rate – 115,200 bps
Data bit – 8
Parity – None
Flow control – None
7) The scanner will automatically restart itself when upgrading firmware is completed successfully.
1) Connect the 3667 cradle or any Bluetooth dongle to your computer via the USB port.
2) Refer to section 1.6.1 for the target scanner to establish a connection with your computer via
the 3667 cradle or a dongle.
Read the following labels in sequence to configure the scanner to use Bluetooth Serial Port as output interface.
Enter Setup
Activate Bluetooth SPP (and read labels for PIN code…)
Update
3) Same as steps 5 ~ 7 above.
64
Appendix IV Upgrading Firmware
HOW TO UPGRADE 3666 FIRMWARE
FIND OUT FIRMWARE VERSION OF 3666
1) Connect the power supply cord from the 3666 cradle to a proper power outlet.
2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port.
3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle.
Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds.
Both labels can be located at the bottom of the cradle.
4) Read the following labels in sequence for the 3666 cradle to enter the download mode.
The LED of the cradle will be flashing red and green to indicate it is ready for downloading.
Enter Setup
3666 Download
5) Run the download utility “ProgLoad.exe” or “Download.exe” on your computer.
(Download.exe requires version 2.3 or later!)
Open the firmware update “3666*.shx”, and select the correct COM port.
Baud rate – 38,400 bps
Data bit – 8
Parity – None
Flow control – None
6) The 3666 cradle will automatically restart itself when upgrading firmware is completed
successfully.
7) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).
Update
1) Connect the power supply cord from the 3666 cradle to a proper power outlet.
2) Connect the serial cable between the 3666 cradle and your computer via the RS-232 port.
3) Refer to section 1.5 for a scanner to set connection with the 3666 cradle.
Read the “Set Connection” label first, and then the “Serial Number” label within 5 seconds.
Both labels can be located at the bottom of the cradle.
65
Scanner Configuration SmartScan Manual
4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in
sequence for the scanner to get the firmware version of the 3666 cradle.
If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.
Enter Setup
Version
5) The current version information of the 3666 cradle will be displayed. For example,
Version = V1.06 Oct 01 2003
SN: SW3000014
6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).
Update
66
Scanner Configuration SmartScan Manual
4) If RS-232 is selected for output interface, run “HypterTerminal” and read the following labels in
sequence for the scanner to get the firmware version of the 3666 cradle.
If Keyboard Wedge or USB HID is selected for output interface, run “WordPad” instead.
Enter Setup
Version
5) The current version information of the 3666 cradle will be displayed. For example,
Version = V1.06 Oct 01 2003
SN: SW3000014
6) Read the “Update” label for the scanner to resume its operation (exit the configuration mode).
Update
66
Loading...