DOC Version 2.21
This documentis specifically designed for the user to print twopages per sheet ofpaper with optimal
print quality.
Copyright © 2005~ 2008 CIPHERLAB CO., LTD.
All rights reserved
The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a
license agreement containing restrictions on use and disclosure and is also protected by copyright
law. Reverse engineering of the software is prohibited.
Due to continued product development this information may change without notice. The
information and intellectual property contained herein is confidential between CIPHERLAB and the
client and remains the exclusive property of CIPHERLAB CO., LTD. If you find any problems in the
documentation, please report them to us in writing. CIPHERLAB does not warrant that this
document is error-free.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any
form or by any means, electronic, mechanical, photocopying, recording or otherwise without the
prior written permission of CIPHERLAB CO., LTD.
For product consultancy and technical support, please contact your local sales representative. Also,
you may visit our web site for more information.
The CipherLab logo is a registered trademark of CIPHERLAB CO., LTD.
Microsoft, Windows, and the Windows logo are registered trademarks of Microsoft Corporation in
the United States and/or other countries.
Bluetooth is a trademark of Bluetooth SIG, Inc., U.S.A.
Other product names mentioned in this manual may be trademarks or registered trademarks of their
respective companies and are hereby acknowledged.
The editorial use of these names is for identification as well as to the benefit of the owners, with no
intention of infringement.
CIPHERLAB CO., LTD.
Website:
http://www.cipherlab.com
2.21 Jan. 02, 2008 Larger setup barcodes
2.20 Nov. 30, 2007 New Word template applied
New: 3667 Bluetooth Cradle for 1166/1266
Modified: Auto-Sense mode supported on 1100 only.
New: Appendix III – Host Serial Commands
New: Appendix IV – Upgrading Firmware
2.15 Nov.13, 2006
2.14~
Nov. 06, 2006
Modified: Add notice for BT SPP and HID power saving – Please
disable power saving when connecting more than two 1x66
scanners to Bluetooth dongle.
New: Bluetooth HID supports Japanese keyboard.
2.12
2.11 Jan.27, 2006
2.10 Jan.18, 2006
Mar. 03, 2006
Modified: Typo errors corrected.
Modified: Bluetooth HID doesn’t support the following functions on
PDAs running Windows CE – Capital Lock Setting: Auto Detection,
Digit Transmission: Numeric Key, and Alt Composing.
Modified: The default Capital Lock setting of Bluetooth HID is
changed from “Auto Detection” to “Capital Lock Off”.
New: Firmware version V4.20
2.00 Dec. 30, 2005
New: Bluetooth HID supported
New: Firmware version V4.10
1.00 Oct. 31, 2005 First release
CONTENTS
RELEASE NOTES .................................................................................................................................. 3
OVERVIEW..................................................
.......................................................................................... 1
BLUETOOTH SETTINGS (1166/1266)................................................................................................. 3
READER SETTINGS .............................................................................................................................. 9
OUTPUT INTERFACES......................................................................................................................... 13
Enter Configuration Mode................................................................................................................. 1
Exit Configuration Mode.................................................................................................................... 1
Update Settings............................................................................................................................ 1
Exit without Changes.................................................................................................................... 1
Restore Defaults................................................................................................................................ 1
List Current Settings.......................................................................................................................... 2
1.1 RF Auto Shutdown (Suspend mode) ......................................................................................... 3
1.2 Power Saving (Sniff Mode)......................................................................................................... 3
1.3 Transmit Buffer Setting .............................................................................................................. 3
1.4 Memory Mode............................................................................................................................. 3
1.4.1 Memory Mode .................................................................................................................... 3
1.4.2 Send Data........................................................................................................................... 4
1.4.3 Clear Data........................................................................................................................... 4
1.4.4 Memory Data Delay............................................................................................................ 4
1.5 Set Connection with 3666 ......................................................................................................... 5
1.6 Set Connection with 3667 or Generic Dongle .......................................................................... 5
1.6.1 Bluetooth Serial Port Parameters ..................................................................................... 5
1.6.2 Bluetooth HID Parameters................................................................................................. 6
2.1 Good Read Notification .............................................................................................................. 9
2.1.1 Buzzer Setting .................................................................................................................... 9
2.1.2 Buzzer Frequency............................................................................................................... 9
2.2 Read Redundancy ...................................................................................................................... 9
2.3 Scan Mode .................................................................................................................................. 9
2.4 Auto-Sense Mode (1100 only) .................................................................................................10
2.5 Scanner Time-Out .....................................................................................................................10
2.6 Delay between Re-read ............................................................................................................ 10
2.7 Negative Barcode Setting ........................................................................................................11
3.1 Keyboard Wedge Parameters.................................................................................................. 13
3.1.1 Activate and Select Keyboard Type................................................................................. 13
3.1.2 Alphabets Layout.............................................................................................................. 14
3.1.3 Digits Layout..................................................................................................................... 14
3.1.4 Capital Lock Type ............................................................................................................. 14
3.1.5 Capital Lock Setting .........................................................................................................14
3.1.6 Alphabets Transmission ..................................................................................................15
Scanner Configuration SmartScan Manual
SYMBOLOGY SETTINGS ..................................................................................................................... 21
DATA OUTPUT FORMAT...................................................................................................................... 43
3.1.7 Digits Transmission..........................................................................................................15
3.1.8 ALT Composing................................................................................................................. 15
3.1.9 Inter-Character Delay ....................................................................................................... 15
3.1.10 Laptop Support ..............................................................................................................15
3.2 RS-232 Parameters..................................................................................................................16
3.2.1 Activate RS-232 Interface ...............................................................................................16
3.2.2 Baud Rate......................................................................................................................... 16
3.2.3 Parity ................................................................................................................................. 16
3.2.4 Data Bits ........................................................................................................................... 17
3.2.5 Flow Control......................................................................................................................17
3.2.6 Inter-Character Delay ....................................................................................................... 17
3.3 WAND Emulation Parameters (1090+/1100/1105/1200) .................................................18
3.3.1 Activate Wand Emulation.................................................................................................18
3.3.2 Normal State ....................................................................................................................18
3.3.3 Bar State...........................................................................................................................18
3.3.4 Module Time.....................................................................................................................18
3.3.5 Margin Time...................................................................................................................... 19
4.1 Select Readable Barcodes.......................................................................................................21
4.2 Codabar Parameters ................................................................................................................25
4.3 Code 25 Parameters ................................................................................................................ 26
4.3.1 Industrial 25 .....................................................................................................................26
4.3.2 Interleaved 25 ..................................................................................................................27
4.3.3 Matrix 25 ..........................................................................................................................28
4.4 Code 39 Parameters ................................................................................................................ 30
4.5 Code 93 Parameters ................................................................................................................ 30
4.6 Code 128 Parameters..............................................................................................................30
4.7 EAN-8 Parameters .................................................................................................................... 31
4.8 EAN-13 Parameters.................................................................................................................. 32
4.9 EAN-128 Parameters................................................................................................................33
4.10 MSI Parameters...................................................................................................................... 34
4.11 Pharmacode Parameters....................................................................................................... 36
4.11.1 French Pharmacode ......................................................................................................36
4.11.2 Italian Pharmacode .......................................................................................................36
4.12 Plessey Parameters ...............................................................................................................37
4.13 RSS Family Parameters .........................................................................................................38
4.13.1 RSS-14............................................................................................................................ 38
4.13.2 RSS Limited....................................................................................................................38
4.13.3 RSS Expanded................................................................................................................ 39
4.14 Telepen Parameters...............................................................................................................40
4.15 UPC-A Parameters ..................................................................................................................41
4.16 UPC-E Parameters ..................................................................................................................42
5.1 Character Substitution ............................................................................................................. 43
5.2 Prefix/Suffix Setting..................................................................................................................43
Scanner Configuration SmartScan Manual
DATA EDITING .................................................................................................................................... 49
NUMERAL SYSTEMS ..........................................................................................................................57
KEYBOARD WEDGE TABLE & ASCII TABLE........................................................................................ 59
HOST SERIAL COMMANDS ................................................................................................................61
UPGRADING FIRMWARE .................................................................................................................... 63
5.3 Code ID Setting .........................................................................................................................43
5.3.1 Clear Code ID Settings..................................................................................................... 43
5.3.2 Select Pre-defined Code ID.............................................................................................. 44
5.3.3 Change Code ID................................................................................................................ 44
5.4 Length Code Setting .................................................................................................................45
6.1 Format Selection ......................................................................................................................49
6.1.1 Activate Editing Formats..................................................................................................49
6.1.2 Exclusive Data Editing...................................................................................................... 49
6.2 Editing Format Parameters ......................................................................................................50
6.2.1 Select Format to Configure.............................................................................................. 50
6.2.2 Restore Default Format ................................................................................................... 50
6.2.3 Define Data Criteria .........................................................................................................50
6.2.4 Divide Data into Fields.....................................................................................................52
6.2.5 Additional Fields............................................................................................................... 55
6.2.6 Field Transmission Sequence .........................................................................................56
Decimal System............................................................................................................................... 57
Hexadecimal System....................................................................................................................... 58
Keyboard Wedge Table ...................................................................................................................59
Key Type......................................................................................................................................59
Key Status ..................................................................................................................................60
ASCII Table.......................................................................................................................................60
Serial Commands............................................................................................................................ 61
Example ...........................................................................................................................................61
How to Upgrade 1166/1266 Firmware.........................................................................................63
Using 3666................................................................................................................................. 63
Using 3667 or Generic Dongle..................................................................................................64
How to Upgrade 3666 Firmware ....................................................................................................65
Find out Firmware Version of 3666 ..........................................................................................65
EXIT CONFIGURATION MODE
UPDATE SETTINGS
Serial Command
N/A
Enter Setup
Serial Command
9999
Update
Serial Command
9998
Abort
Serial Command
9993
Restore Defaults
Note: The default value (if there is) for each setting is included in a pair of angle brackets “<>”.
Update
1
Scanner Configuration SmartScan Manual
Serial Command
9950
Page 1
Serial Command
9951
Page 2
Serial Command
9952
Page 3
Serial Command
9953
Page 4
Serial Command
9954
Page 5
Serial Command
9955
List settings regarding Interface, Buzzer, and
Scanner Parameters
List settings regarding Prefix, Postfix, and
Length Code Setting
List settings regarding Code ID
List settings regarding: Readable Symbologies
List settings regarding Symbology Parameters
(1/3)
List settings regarding Symbology Parameters
(2/3)
Page 6
Serial Command
9956
Page 7
Serial Command
9957
Page 8
Serial Command
9958
Page 9
Serial Command
9959
Page 10
List settings regarding Symbology Parameters
(3/3)
List settings regarding Editing Format 1
List settings regarding Editing Format 2
List settings regarding Editing Format 3
2
Enter Setup
1.1 RF AUTO SHUTDOWN (SUSPEND MODE)
1.2 POWER SAVING (SNIFF MODE)
1.3 TRANSMIT BUFFER SETTING
1.4 MEMORY MODE
1.4.1 MEMORY MODE
Chapter 1
BLUETOOTH SETTINGS (1166/1266)
1) Read this label to specify the time interval before the scanner enters suspend mode.
2) Read the “Decimal Value
suspend the connection with 3666 after being idle for 15 minutes.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0445
RF Auto Shutdown
” label on page 57. For example, read “1” and “5” for the scanner to
after … minutes
Serial Command
0458
<Enable> Disable
Serial Command
0459
Serial Command
0386
Serial Command
0387
Enable <Disable>
Serial Command
0321
Enable <Disable>
Serial Command
0320
Update
3
Scanner Configuration SmartScan Manual
Serial Command
9918
Send Data
1) Read the “Clear Data” label to clear the flash memory.
2) Read the “Confirm” label to confirm the action.
Serial Command
9916
Clear Data Confirm
Serial Command
9917
Serial Command
0322
<None> 250 ms
Serial Command
0324
500 ms 1 sec
Serial Command
0326
2 sec 3 sec
Serial Command
0328
Serial Command
0323
Serial Command
0325
Serial Command
0327
Serial Command
0329
5 sec 8 sec
4
Enter Setup
Chapter 1
1.5 SET CONNECTION WITH 3666
1.6 SET CONNECTION WITH 3667 OR GENERIC DONGLE
1.6.1 BLUETOOTH SERIAL PORT PARAMETERS
Bluetooth Settings (1166/1266)
1) Read this label or the same one at the bottom of the 3666 cradle.
2) Read the “Serial Number” label at the bottom of the cradle within 5 seconds.
3) Proceed to select a desired output interface.
Serial Command
Set Connection
Serial Command
0453
Activate Bluetooth SPP
Serial Command
0450
<Yes> No
Serial Command
0448
Yes <No>
1) Read this label to specify the PIN code.
2) Read the “Hexadecimal Value
characters are allowed).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0452
” label on page 58 for the desired character string (max. 6
Serial Command
0451
Serial Command
0449
Enter PIN Code …
Update
5
Scanner Configuration SmartScan Manual
1.6.2 BLUETOOTH HID PARAMETERS
NO. KEYBOARD TYPE NO. KEYBOARD TYPE
1) Read this label to activate Bluetooth HID and select a keyboard type.
2) Read the “
Decimal Value
” label on page 57. Refer to the table below for the number of desired
keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0000
Activate & Select
Keyboard Type …
64 PCAT (US) 70 PCAT (UK)
65 PCAT (French) 71 PCAT (Belgium)
66 PCAT (German) 72 PCAT (Spanish)
67 PCAT (Italian) 73 PCAT (Portuguese)
68 PCAT (Swedish) 74 PS55 A01-2 (Japanese)
69 PCAT (Norwegian)
Read this label when switching connection from one PC to another and re-connection is required.
Serial Command
9972
Reset Connection
Serial Command
0450
Serial Command
0451
<Yes> No
Serial Command
0448
Serial Command
0449
Yes <No>
6
Enter Setup
1) Read this label to specify the PIN code.
Chapter 1
Bluetooth Settings (1166/1266)
2) Read the “Hexadecimal Value
” label on page 58 for the desired character string (max. 6
characters are allowed).
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0452
Enter PIN Code …
Serial Command
0312
Serial Command
0313
<Default Layout> AZERTY
Serial Command
0314
QWERTZ
Serial Command
0007
Serial Command
0008
<Default Layout> Upper Row
Serial Command
0009
Lower Row
Serial Command
0010
Serial Command
0011
<Default> Shift Lock
Serial Command
0012
Capital Lock
7
Update
Scanner Configuration SmartScan Manual
Serial Command
0002
Serial Command
0003
Auto Detection Capital Lock ON
Serial Command
0004
<Capital Lock OFF>
Serial Command
0005
Serial Command
0006
Ignore Case <Case-Sensitive>
Serial Command
0013
Serial Command
0014
Numeric Key <Alphanumeric
Key>
Serial Command
0335
Serial Command
0334
Yes <No>
8
Enter Setup
2.1 GOOD READ NOTIFICATION
2.1.1 BUZZER SETTING
Chapter 2
READER SETTINGS
Serial Command
0318
<Enable Buzzer> Disable Buzzer
Serial Command
0319
Serial Command
0046
8 kHz <4 kHz>
Serial Command
0048
2 kHz 1 kHz
Serial Command
0047
Serial Command
0049
Serial Command
0201
Serial Command
0202
<No Redundancy> One Time
Serial Command
0203
Two Times Three Times
Serial Command
0204
Serial Command
0066
<Auto Off Mode>
(Default for 1000/1090+)
Serial Command
0067
Continuous Mode
Update
9
Scanner Configuration SmartScan Manual
2.4 AUTO-SENSE MODE (1100 ONLY)
2.6 DELAY BETWEEN RE-READ
Serial Command
0068
Auto Power Off Mode Alternate Mode
Serial Command
0070
Momentary Mode Repeat Mode
Serial Command
0072
<Laser Mode>
(Default for
1100/1105/1166/1200/1266)
Serial Command
0069
Serial Command
0071
Serial Command
0073
Test Mode
Serial Command
0333
Enable <Disable>
Serial Command
0332
1) Read this label to specify the time interval before the scan engine times out in Laser, Auto Off, or
Auto Power Off mode.
2) Read the “Decimal Value
automatically shut down after being idle for 10 seconds.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0207
Scanner Time-
” label on page 57. For example, read “1” and “0” for the scanner to
Out
after … seconds
Serial Command
0336
100 ms 200 ms
Serial Command
0337
10
Enter Setup
Chapter 2 Reader Settings
2.7 NEGATIVE BARCODE SETTING
Serial Command
0338
<400 ms> 800 ms
Serial Command
0340
1 sec 2 sec
Serial Command
0342
3 sec 5 sec
Serial Command
0339
Serial Command
0341
Serial Command
0343
Serial Command
0199
Enable <Disable>
Serial Command
0200
Update
11
Scanner Configuration SmartScan Manual
12
Enter Setup
3.1 KEYBOARD WEDGE PARAMETERS
3.1.1 ACTIVATE AND SELECT KEYBOARD TYPE
NO. KEYBOARD TYPE NO. KEYBOARD TYPE
Chapter 3
OUTPUT INTERFACES
1) Read this label to activate Keyboard Wedge and select a keyboard type.
2) Read the “
keyboard type.
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0000
Activate & Select
1 PCAT (US) 15 PS55 001-81
2 PCAT (French) 16 PS55 001-2
3 PCAT (German) 17 PS55 001-82
4 PCAT (Italian) 18 PS55 001-3
5 PCAT (Swedish) 19 PS55 001-8A
6 PCAT (Norwegian) 20 PS55 002-1, 003-1
7 PCAT (UK) 21 PS55 002-81, 003-81
Decimal Value
” label on page 57. Refer to the table below for the number of desired
Keyboard Type …
8 PCAT (Belgium) 22 PS55 002-2, 003-2
9 PCAT (Spanish) 23 PS55 002-82, 003-82
10 PCAT (Portuguese) 24 PS55 002-3, 003-3
11 PS55 A01-1 25 PS55 002-8A, 003-8A
12 PS55 A01-2 (Japanese) 26 IBM 3477 Type 4 (Japanese)
13 PS55 A01-3 27 PS2-30
14 PS55 001-1 28 IBM 34XX/319X, Memorex Telex 122 Keys
13
Update
Scanner Configuration SmartScan Manual
3.1.5 CAPITAL LOCK SETTING
Serial Command
0312
<Default Layout> AZERTY
Serial Command
0314
QWERTZ
Serial Command
0313
Serial Command
0007
<Default Layout> Upper Row
Serial Command
0009
Lower Row
Serial Command
0008
Serial Command
0010
<Default> Shift Lock
Serial Command
0012
Capital Lock
Serial Command
0011
Serial Command
0002
Auto Detection Capital Lock ON
Serial Command
0004
<Capital Lock OFF>
Serial Command
0003
14
Enter Setup
3.1.6 ALPHABETS TRANSMISSION
3.1.7 DIGITS TRANSMISSION
3.1.9 INTER-CHARACTER DELAY
Chapter 3 Output Interfaces
Serial Command
0005
Ignore Case <Case-Sensitive>
Serial Command
0006
Serial Command
0013
Numeric Key <Alphanumeric
Serial Command
0014
Key>
Serial Command
0335
Yes <No>
Serial Command
0334
1) Read this label to specify the inter-character delay.
2) Read the “
3) Read the “Validate” label on the same page to complete this setting.
Serial Command
0015
Inter-Character
Decimal Value
” label on page 57 for the desired inter-character delay (millisecond).
Delay …
Serial Command
0389
Enable <Disable>
Serial Command
0388
Update
15