CHINO KR3000 Specifications

KR3000 SERIES
GRAPHIC RECORDER
KR3000 Series are network-compatible paperless recorders with high performance and high operating function employed high visibility 12.1” TFT color LCD display and touch panel operation system. High speed of sampling rate 100ms for 48 points and high accuracy of ±0.1% were realized, and measured data is stored into internal memory and maximum 2GB compact flash card (CF card). As it can be monitored by a web browser display on several computers on intranet or internet, FTP transfer of data file and E-mail notification are also available.
FEA TURES
zLarge sized 12.1” TFT color LCD display
x Large-sized high visibility display with various display
functions. Real time/Historical trend screen, Bar-graph screen, Data screen are selectable for various applications.
x Combination display for selected 4 screens is available. It is
easy to switch to individual screen by touching panel.
zLarge capacity of data memory and various recording
method
x Compact flash card (CF card) slot is equipped as standard
external memory. Large capacity storage of maximum 2GB is available.
x Various data storing methods are selectable such as schedule
programming by time of day and time of date, recording start-up by external signal and event, and data logging of before and after trigger points for alarm.
zMulti points recording with high speed/high accuracy
x High-speed recording of approximately 100ms for 48 points
and high accuracy of ±0.1% were realized. Stable measuring and recording are possible with high speed.
x High withstand voltage of 1000V AC between input channels.
zEasy operating and programming without manuals
x Easy operating by dedicated keys for each function and touch
panel.
x USB port is prepared in front compartment. Setting file and
data file are stored in USB memory stick.
zLAN network capability
x Various networked environment such as remote monitoring by
browser, FTP server, FTP client and E-mail notification are applied as Ethernet is equipped as standard.
zAnalyzing/data acquisition application software
x It is easy to replay and edit the recorded data file. Replay
display has functions of vertical/horizontal trend, circular trend, and also wave-analyzing and marking by using the cursor.
MODELS
KR31□□-□□A
Measuring points/sampling rate 20: 12 points/100ms 40: 24 points/100ms 60: 36 points/100ms 80: 48 points/100ms 21: 12 points/1s 41: 24 points/1s 61: 36 points/1s 81: 48 points/1s Communications interface (option) N: None R: High-order (RS232C) S: High-order (RS422A/RS485) Digital input/alarm output (option) 0: None 1: Alarm output 12 points (a contact) 2: Alarm output 6 points (c contact) 3: Alarm output 24 points (a contact) 4: Alarm output 12 points (c contact) 5: Alarm output 12 points (a contact)
+ 6 points (c contact) A: Digital input 8 points B: Digital input 8 points
+ alarm output 12 points (a contact) C: Digital input 8 points
+ alarm output 6 points (c contact) D: Digital input 8 points
+ alarm output 24 points (a contact) E: Digital input 8 points
+ alarm output 12 points (c contact)
F: Digital input 8 points + alarm output 12 points (a contact) + alarm output 6 points (c contact)
1
PSE-354B
SCREENS
zReal-time trend screen
Displays data (measured and virtual) of selected group. Vertical trend and horizontal trend selectable.
zData screen
Displays data (measured and virtual) of selected group. Simultaneous display of alarm status.
zBar-graph screen
Displays data (measured and virtual) of selected group. Combination display with real-time trend is available.
z4 separate screen
Switchable from displayed 4 screens to individual screen by touch panel.
zInformation screen
zChannel setting screen
zHOME setting screen
zSchedule setting screen
2
j
(Up
INPUT SPECIFICATIONS
Measuring points: 12 points, 24 points, 36 points and 48 points Input types: Universal
±200mV, ±500mV, ±2V
Accuracy ratings: Refer to the table of measuring range, accuracy ratings and
Reference junction compensation accuracy:
Sampling rate: 100ms --- Approximately 100ms for all points 1s --- Approximately 300ms for all points Burnout: Disconnection of input signal is detected on thermocouple
Scaling: Range/scale is selectable when DC voltage/current is
Digital filter: FIR filter Allowable signal source resistance:
Input resistance: DC voltage, thermocouple input --- Approximately 1 M Maximum input voltage: DC voltage input (±2V or less)/
Dielectric strength between channels:
(High strength semiconductor relay used)
Common mode rejection ratio:
Series mode re
RECORDING SPECIFICATIONS
Memory for history: 136MB Additional memory: CF card (Up to 2GB) Recording cycle: 100, 200, 500ms 1, 2, 3, 5, 10, 15, 20, 30s 1, 2, 3, 5, 10, 15, 20, 30, 60min Logging data: Measured data --- File name (group name), time of day,
Storing types: Binary/CSV type Storing methods: Manual start/stop (dedicated key operation)
ection ratio: 50dB
Recording group: 6 groups of 56 points/group can be programmed
When 12 channels recorded in sampling mode (real data).
Recording cycle 128MB 256MB 512MB 1GB 2GB
0.1 sec 3.16 days 6.32 days 12.6 days 25.3 days 50.6 days 1sec 31.6 days 63.2 days 126 days 253 days 1.4 yrs
60 sec 5.2 yrs 10 yrs 21 yrs 42 yrs 83 yrs
When 24 channels recorded in sampling mode (real data).
Recording cycle 128MB 256MB 512MB 1GB 2GB
0.1 sec 1.58 days 3.16 days 6.32 days 12.6 days 25.3 days 1sec 15.8 days 31.6 days 63.2 days 126 days 253 yrs
60 sec 2.6 yrs 5.2 yrs 10 yrs 21 yrs 42 yrs
When 36 channels recorded in sampling mode (real data).
Recording cycle 128MB 256MB 512MB 1GB 2GB
0.1 sec 1.05 days 2.11 days 4.20 days 8.43 days 16.9 days 1sec 10.5 days 21.1 days 42.0 days 84.3 days 168 days
60 sec 1.7 yrs 3.3 yrs 7 yrs 14 yrs 27 yrs
When 48 channels recorded in sampling mode (real data).
Recording cycle 128MB 256MB 512MB 1GB 2GB
0.1 sec 18.9 days 1.58 days 3.16 days 6.32 days 12.6 days 1sec 7.9 days 15.8 days 31.6 days 63.2 days 126 yrs
60 sec 1.3 yrs 2.6 yrs 5.2 yrs 10 yrs 21 yrs
COMPUTATION SPECIFICATIONS
Computation points: Maximum 128 points Computation cycle: 100ms for all points Computation types: Arithmetic operations --- Addition, subtraction, multiplication, division, remainder, exponential
Others --- Dew point, relative humidity,
Remaining amount of CFcard
DC voltage --- ±13.8mV, ±27.6mV, ±69.0mV
±5V*, ±10V*, ±20V*, ±50V*
DC current --- With external shunt resistor (sold separately) Thermocouple --- B, R, S, K, E, J, T, N, PtRh40-PtRh20,
Resistance thermometer --- Pt100, JPt100, Pt50, Pt-Co
display resolution K, E, J, T, N, Platinel--- ±0.5ºC or less
R, S, W-WRe26, WRe5-WRe26, NiMo-Ni, CR-AuFe, U, L --- ±1.0 ºC or less
and resistance thermometer input. UP/DOWN/DISABLE is selectable for each input
programmed
Thermocouple input (burnout disable)/ DC voltage input (±2V or less) --- 1k or less DC voltage input (±5V or more) --- 100Ω or less Resistance thermometer --- Per wire 10 or less
thermocouple input (burnout disable) --- ±10VDC DC voltage input (±5V to ±50V) --- ±60VDC
1000V AC or more between each channel
(B terminal of resistance thermometer is shorted inside between channels.)
120dB
month and year of recording start, tag, measured data, alarm status/types, makertext Setting parameter
Schedule (designation for time of day and date) Trigger signal (alarm event, digital input) Data logging of before and after trigger points * Pre-trigger is selectable
Measuring numbers of pre-trigger --- Max 950 data
to Total of 128 points)
Comparison operations --- Equality, inequality, great, less, equality/great, equality /less Logical operations --- AND, OR, XOR, NOT General functions --- Round-up, round-down,
Integration operations --- Analog integration, digital integration Channel data operations ---
(*with built-in voltage divider)
W-WRe26, WRe5-WRe26, PlatinelⅡ, NiMo-Ni, CR-AuFe, U, L
(same resistance for 3 wires)
absolute value, square root, exponent of e, natural logarithm, common logarithm
Measured data computation, calculated data computation
F-value
ALARM SPECIFICATIONS
Setups: Up to 4 alarms can be programmed per channel Alarm types: Upper limit, lower limit, differential upper limit, differential lower limit
Delay function: Setup range of alarm delay --- 1 to 3600 seconds Alarm settings: AND/OR selectable Alarm outputs: Refer to option specification
DISPLAY SPECIFICATIONS
Display: 12.1” TFT color LCD Display types: Measured data display (Trend screen, Data screen, Bar-graph screen)
(simultaneous display with Real-time trend is available)
(alarm display, marker list, file list)
(alarm, computation, memory, system, maintenance, communication, etc.) Trend screen: 48 colors selectable
Data screen: Display screen --- 6 screens (6 groups)
Bargraph screen:
Information display:
LCD back light:
*The LCD display may contain some pixels that always or never illuminate, and the brightness of some areas of the display may appear uneven. There are typical LCD performance characteristics and do not constitute malfunctions.
(deadband is selectable), abnormal data
Historical trend display
Information display
Setting screen
Display screen--- 6 screens (6 groups) Display points --- Maximum 56 points/screen Time axis direction --- Vertical or horizontal Line width --- 1 to 5 dot selectable Scale display --- 4 scales Tag/data display --- Show/hide selectable Marker display
Display points --- Maximum 56 points/screen Display contents --- Measured value, channel/tag, unit, alarm status
48 colors selectable Display screen --- 6 screens (6 groups) Display points --- Maximum 56 points/screen Display direction --- Vertical or horizontal Scale display --- 1 scale
Alarm display (alarm activation/released history display) Marker list File list (group data file list display) Unit information (Model, serial no., option, etc.)
Auto/manual OFF function Brightness --- 4 levels adjustment
COMMUNICATION FUNCTIONS
zNetwork
Communication type:
FTP server : Data file can be read from the network computer FTP client : Transfer a data file to a network server SNTP client : The time can be synchronized to the time of SNTP server Web server : Conformed to HTTP1.0 --- Display the alarm, information of maintenance
E-Mail: E-Mail notification at specified time for alarm activation
Notification address --- Maximum 8 contacts
zUSB Communications
Communication type:
Ethernet (10BASE-T/100BASE-TX)
by browser software (InternetExplorer5.0 or later, NetScape6.0 or later, Opera7 or later)
* User’s ID and password registration available.
Report data at specified time is selectable from all registered data
USB2.0 (full speed), host function USB memory stick is used as external memory
Some USB memory stick can not be used.
CONNECTIVITY
3
PROGRAMING/OPERATION
Operation method: Touch panel/dedicated key Operation keys: HOME, MENU, DISP, MARKER, SCROLL, CURSOR, START,
HOME settings: Simple recording settings --- Common setting to all channels
MENU settings: Input/computation programming --- Input parameter,
DISP operations: Operating screen selection --- Trend, data, bar-graph,
Display selection on each screen --- Group 1 to 6 selectable
GENERAL SPECIFICATIONS
Rated power voltage: 100 to 240V AC (universal power supply) 50/60Hz Maximum power consumption:
Reference operating condition:
Power frequency --- 50/60Hz±0.5%
Normal operating condition:
Transport condition (at the packed condition on shipment from our factory):
Storage condition: Ambient temperature --- -20 to 60ºC Ambient humidity --- 5 to 90%RH (No dew condensation) Power failure protection: Setups and data are backed up by flash memory. Clock:Lithium battery backs up RAM (Minimum 5 years) Insulation resistance: Secondary terminals and protective conductor terminals ---
Secondry terminals: measuring input terminals, digital input terminals,
Dielectric strength: Secondary terminals and protective conductor terminals --- 1 minute at 500V AC
Secondry terminals: measuring input terminals, digital input terminals
Case assembly material: Front bezel --- ABS resin Case --- Steel Color: Front bezel --- Black (equivalent to Mussel N3.0)
Weight: 7.2kg Mounting: Panel mounting Terminal screws: Power terminals/protective conductor terminals/communications terminals --- M4.0
STOP, DIRECTION keys, ENTER, ESC
Parameter programming for all channels together, recording cycle, selection settings
computation parameter DISP Settings --- Data channel parameter, group parameter, common parameter (combination display, trend vertical/horizontal) Alarm settings File settings (6 individual files) --- Storing method settings Marker text settings System settings --- Communication, clock, maintenance, key lock, password, screen, etc.
historical trend, alarm display, maker list
65VA
Ambient temperature --- 21 to 25ºC, Ambient humidity --- 45 to 65%RH Power voltage --- 100V AC±1.0%
Attitude --- Left/right 0°, forward/backward 0° Warm-up time --- Longer than 30 minutes
Ambient temperature --- 0 to 50ºC Ambient humidity --- 20 to 80%RH Power voltage --- 90 to 264V AC Power frequency --- 50/60Hz±2% Attitude --- left/right 0°, forward tilting 0°, backward tilting 0° to 20°
Ambient temperature --- -20 to 60 ºC Ambient humidity --- 5 to 90%RH (No dew condensation) Vibration --- 10 to 60Hz 4.9m/ S Impact --- 392m/S2 (40G) or less
20M or more at 500V DC Primary terminals and protective conductor terminals --- 20M or more at 500V DC Primary and secondary terminals --­20M or more at 500V DC
Primary terminals: power terminals (L,N), alarm output terminals
communications terminals
Primary terminals and protective conductor terminals --- 1 minute at 1500V AC Primary and secondary terminals --- 1 minute at 2300V AC
Primary terminals:power terminals (L,N), alarm output tereminals
communications terminals
Case --- Painting color, gray (equivalent to Mussel N7.0)
Measuring input terminals/alarm output terminals/digital input terminals --- M3.5
2
(0.5G) or less
OPTIONS
OPERATION KEYS
4
MEASURING RANGES/ACCURACY RATINGS
Input type Measuring range Accuracy rating
DC voltage
(with built-in voltage divider)
K
E
J
T
R
S
B 0 to 1820ºC
N
T/C
W-WRe26 0 to 2315ºC
WRe5-WRe26 0 to 2315ºC ±0.2%±1digit
PtRh40-PtRh20 0 to 1888ºC
NiMo-Ni
CR-AuFe 0.0 to 280.0K
Platinel
U
L
RTD
Pt100
JPt100
Note: The accuracy ratings are converted into the measuring range under
K,E,J,T,R,S,B,N:IEC584,JIS C1602-1995 W-WRe26,WRe5-WRe26,PtRh40-PtRh20,PlatinelⅡ,NiMo-Ni, Cr-AuFe:ASTM Vol14.03 U(Cu-CuNi),L(Fe-CuNi):DIN43710 Pt100:IEC751(1995),JIS C1604-1997, JPt100:JIS C1606-1989
Pt50 -200.0 to 649.0ºC ±0.1%±1digit
Pt-Co 4.0 to 374.0K
reference operating condition. Thermocouple input does not contain reference junction compensation accuracy.
-13.80 to 13.80mV
-27.60 to 27.60mV
-69.00 to 69.00mV
-200.0 to 200.0mV
-500.0 to 500.0mV
-2.000 to 2.000V
-5.000 to 5.000V
-10.00 to 10.00V
-20.00 to 20.00V
-50.00 to 50.00V
-200.0 to 300.0ºC
-200.0 to 600.0ºC
-200 to 1370ºC
-200.0 to 200.0ºC
-200.0 to 350.0ºC
-200 to 900ºC
-200.0 to 250.0ºC
-200.0 to 500.0ºC
-200 to 1200ºC
-200.0 to 250.0ºC
-200.0 to 400.0ºC
0 to 1200 ºC
0 to 1760 ºC
0 to 1300ºC
0 to 1760ºC
-200.0 to 400.0ºC
-200.0 to 750.0ºC
-200 to 1300ºC
-50.0 to 290.0 ºC
-50.0 to 600.0 ºC
-50 to 1310 ºC
0.0 to 350.0ºC
0.0 to 650.0ºC
0 to 1395ºC
-200.0 to 250.0ºC
-200.0 to 500.0ºC
-200.0 to 600.0ºC
-200.0 to 250.0ºC
-200.0 to 500.0ºC
-200 to 900 ºC
-140.0 to 150.0ºC
-200.0 to 300.0ºC
-200.0 to 850.0ºC
-140.0 to 150.0ºC
-200.0 to 300.0ºC
-200.0 to 649.0ºC
±0.1%±1digit
±0.1%±1digit *-200 to 0ºC: ±0.2%±1digit
±0.1%±1digit
*0 to 400ºC:
±0.2%±1digit
±0.1%±1digit
*0 to 400ºC: Out of
accuracy ratings
*400 to 800ºC: ±0.15%±1digit
±0.15%±1digit
*-200 to 0ºC: ±0.3%±1digit
±0.15%±1digit
*0 to 100ºC:
±4%±1digit
*100 to 400ºC:
±0.5%±1digit
±0.2%±1digit
*0 to 300ºC:
±1.5%±1digit
*300 to 800ºC:
±0.8%±1digit
±0.2%±1digit
±0.2%±1digit
*0 to 20K:
±0.5%±1digit
*20 to 50 K:
±0.3%±1digit
±0.15%±1digit
±0.15%±1digit
*-200 to 0ºC: ±0.3%±1digit
±0.1%±1digit *-200 to 0ºC: ±0.2%±1digit ±0.1%±1digit
*-140.0 to 150.0ºC:
700 to 850ºC: ±0.15%±1digit
±0.1%±1digit
*-140.0 to 150.0ºC:
±0.15%±1digit
±0.15%±1digit
*4 to 50K:
±0.3%±1digit
APPLICATION SOFTWARE ZAILA (sold separately)
The software is applied for replay display/wave editing operation of recorded data in KR3000 series. It has replay display of vertical/horizontal trend and circular trend function, and also analyzing function such as magnify/reduce/partially magnify of graphs and message insert.
zDisplay examples
Trend display window (vertical flow)
Trend display window (circular trend)
Trend display window (horizontal flow)
Bar-graph
zMain functions
Trend display
Selectable from trend display window (vertical flow, horizontal flow) and circular trend display window. Continuous replay display window Trend is scrolled continuously (automatically). Scroll changes by speed and renewal data no. Data list display window Displays registered data as list display Bar-graph Displays by bar. Message can be inserted into bar-graph. Data between markers Displays date/time, time difference between 2 data, data difference, maximum, minimum, average, standard deviation and median among all data. Alarm display Points for alarm activation at each level are displayed on a trend graph. Settings Cursor, trend line, scale axis, time axis, title input on the graph, graph assistant and magnify/reduce/rotation of graphs Data conversion Exporting to Excel, and converting to CSV file or TEXT file are available.
ENVIRONMENT
CPU 1GHz or faster
OS
Memory
Disk drive
Language
Windows 98/Me Windows 2000/XP Home/XP Pro *Internet Explorer 4.0 or later
256MB or more (512MB or more recommended)
CD-ROM drive: 1 drive or more Hard disk drive: Disk space of 1 drive or more for 100MB or more
Japanese, English, Chinese (simplified and traditional characters), Korean
5
TERMINAL ARRANGEMENT
Alarm/Digital input terminals
DIMENSIONES
32-8 KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632
PHONE: +81-3-3956-2171
FAX: +81-3-3956-0915
E-mail: inter@chino.co.jp
Website: http://www.chino.co.jp
Panel cutout and minimum clearance
Unit: mm
Specifications subject to change without notice. Printed in Japan (I) 2008. 1 Recycled Paper
Unit: mm
6
Loading...