IR-H SERIES
HAND HELD RADITION THERMOMETERS
The IR-H series is a small and lightweigh
handheld Infrared thermometer with a clea
viewfinder.
The thru-the-lens optical system enables it to
measure small targets from a long distance.
The measured value can be read on the
internal digital display in the viewfinder. Three
models are available – a high functional type
IR-HQH having combined functions of a 2
color type + single color wide range type, a
single color medium temperature type – IR-HI
and a single color high temperature type
IR-HS.
Data logging software is available for eas
data processing by a personal computer.
FEATURES
High functional type [2-color type + single colo
wide range type] available.
The InGaAs element is used to reduce influence
of emissivity, high sensitivity and high accurate
measurement.
The digital display of measured value is
displayed in the viewfinder and on the fron
panel.
A target size of 20mm diameter can be
measured at the distance of 4m.
CE
x EN61326
x Emission : Class B
x Immunity: Table 1 - Minimum immunity test
requirements
CONFIGURATION
x You can measure low temperature surface’s
and compensate emissivity by connecting a
K-type surface thermocouple.
x Long-term measurement by a hand is made
easy due to its small size (W148 x H100 x D
70mm) and lightweight (about 350g).
x A maximum 500 data can be stored and
replayed.
x Math functions (maximum value, minimum
value, average value, peak and delay)
x Directives: 89/336/EEC, 92/31 EEC amendment,
93/68/EEC amendment
1
PSE-377C

DIAMETER/DISTANCE
THERMOCOUPLES
Model: C510-01K
Model: C510-02K
Element: K
Measuring range: Max. 500°C (Top: Ceramic)
Response time: About 1.8 seconds (90% response to
150°C aluminum block surface)
Unit: mm
Element: K
Measuring range: Max. 800°C
Response time: 4 seconds (90% response to 340°C
aluminum block surface)
2

SPECIFICATIONS
Types
Model IR-HI IR-HS IR-HQH
Measuring system Narrow band radiation thermometer
Element InGaAs Si Si / InGaAs
Wavelength
Temperature range 300 to 1000°C 600 to 2000°C
Accuracy rating
At ε=1.0, ref. operation
condition: 23ºC±5ºC, 35 to
75%RH
Repeatability Within ±1°C
EMC Stability
1.55 µm 0.9 µm 0.9/1.55 µm
±6°C
1. Temperature drift:0.2°C / °C
2. ±3°C; ±50°C [(at the
Resolution 1°C
Response time 0.25 second (1.8 or 4 seconds: connecting with surface temperature sensor)
Emissivity
compensation
Math Maximum value, minimum value, average value
Signal modulation Peak, delay
Display LCD digital display 4-digit in viewfinder and on front panel
Data storage Maximum 500 data
Communications RS232C (Data logging software / IR-VXG1E, sold separately)
Optics Fixed focus system
Diameter/Distance ø20/4000mm (Refer to " Diameter/Distance ".)
Finder Direct view finder
Lens diameter ø20mm
Thermocouple input
Other functions
Working temperature 0 to 50°C
Power
Case material/color Resin/gray
Outside dimensions /
weight
OUTSIDE DIMENSIONS
0.100 to 1.900 (0.001 increment)
K thermocouple: -50 to 800°C
Accuracy: ±2°C (at 23 ± 5°C)
Automatic power-off, automatic back-light display, continuous measurement
°C/°F selection, battery check, high/low alarms
AA battery 2 pieces (about 50 hours at continuous operation) or
AC power adapter (sold separately)
W148 x H100 x D70mm, about 350g (thermometer)
Single color
For medium temperature
connection with code for
RS-232C, AC adapter or
thermocouple C510-0 (K))
Single color
For high temperature
Less than 1000°C: ±6°C
1000 to 1500°C: ±0.6% of measured value
1500 to 2000°C: ±1.2% of measured value
More than 2000°C: ±2.4% of measured value
1. Temperature drift:: Less than 1000°C: 0.2°C / °C
More than 1000°C: 0.02% of measured value / °C
2. ±15°C; ±50°C [(at the connection with code for RS-232C, AC adapter
or thermocouple C510-0 (K)]
High functional type
[2-color type + single color
wide range type]
600 to 2000°C (2-color) /
400 to 3000°C (single color)
(key switching)
Unit: mm
3

DATA LOGGING SOFTWARE / IR-VXG1E (sold separately)
Three kinds of data management mode, real-time trend mode, multi-point monitoring mode by utilizing memory,
and 1-point historical trend mode, are available. Graph display, report creation, printing, and data storage can be
easily executed. The export of the measured data to worksheet applications is also possible.
Model IR-VXG1E
Environment OS Windows 95/98 (Minimum 10MB is required to install.)
Media CD-R (2m of RS-232C cable with D-Sub 9 pins female connector is attached.)
Readout Readout of transmitted data by RS-232C from IR-H
Functions Display on a personal computer, Data storage and replay, Printer output
Graphic display 640 x 480 dots (initial), 1024 x 768 dots (resized by a personal computer)
General specifications
Measurement mode Real-time trend mode, Multi-point monitoring mode, 1-point trend mode
Real-time trend
x
Readout of data
stored
Data logging and
graphic display
Data logging system
Storage type
Export to Excel 97
(*)
Data stored
Storage/output
Printer output
(*) on condition that Excel 97 has been installed in a personal computer
ACCESSORIES (sold separately)
Real-time trend graph (in real-time
trend logging mode)
x
Alarm summary
x
Measuring cycle: 0.5 to 10 seconds
x
Chart speed: 10-second, 1-minute,
5-minute, 10-minute, 1-hour,
2-hour/screen (6-step selection)
x
Scroll function: Chart time axis can
be scrolled after measurement stop
or reply of data stored.
x
Temperature range: Auto-range or
fixed range is selectable.
x
High/low alarms
x
Alarm summary (at stop of data
lo
x
File for replay of trend graph
x
All data of date, time and
temperature on real-time trend
x
Alarm summary
x
Maximum 1000 data
(Maximum memory capacity 600KB)
x
Alarm summary 100 data
(Renewed to up-dated data)
x
Real-time trend graph
x
Alarm summary report
x
x
x
x
x
x
x
x
x
Multi-point
monitoring (30 points)
Readout of monitoring
data up to 30 points
Creation of reports (table,
graph)
[Input of measurement
place name] and [settings
of high/low alarms] are
enabled on each
measurement place.
[Grouping each 5-point] on
table and graph
Storage of 30 points data
base
Monitoring data base table
up to 30 points
Data base up to 30 points
Table form report
Graph form report
x
x
x
x
x
x
x
1-point trend
(500 data)
Readout of continuous
data up to 500 data
Display by graph
Display of all data
Display of specified data
(100 points/10 points
selectable)
Maximum, minimum and
average
Continuous data up to 500
data
Historical trend graph
AC power adapter IR-VHRA Input voltage 100 to 240VAC, Output voltage 4.8VDC
Tripod IR-ZBMT
Universal head IR-VMS
Thermocouple C510-01K K thermocouple, Maximum 500°C, Response time about 1.8 seconds
Thermocouple for high temp. C510-02K K thermocouple, Maximum 800°C, Response time about 4 seconds
Accessories Models Specifications
Note: Windows and Excel are registered trademarks of Microsoft Corporation in the United States. Other brand and product
names are trademarks or registered trademarks of their respective holders.
32-8, KUMANO-CHO, ITABASHI-KU, TOKYO 173-8632
PHONE: +81-3-3956-2171
FAX: +81-3-3956-0915
E-mail: inter@chino.co.jp
Website: http://www.chino.co.jp
Specifications subject to change without notice. Printed in Japan (I) 2002. 5