1. GENERAL DESCRIPTION
1.1 OVERVIEW
M260J3-L01 is a 25.54” TFT Liquid Crystal Display module with 4 CCFL Backlight unit and 30 pins
2ch-LVDS interface. This module supports 1920 x 1200 WUXGA mode and can display up to 16.7M colors.
The inverter module for Backlight is not built in.
1.2 FEATURES
- Extra-wide viewing angle.
- High contrast ratio.
- Fast response time.
- High color saturation.
- WUXGA (19 20 x 1200 pixels) resolution.
- DE (Data Enable) only mode.
- LVDS (Low Voltage Differential Signaling) interface.
- RoHS compliance.
1.3 APPLICA TION
- TFT LCD Monitor
1.4 GENERAL SPECIFICATI0NS
Item Specification Unit Note
Active Area 550.08 (H) x 343.8 (V) (25.54” diagonal) mm
Bezel Opening Area 554.1 (H) x 347.8 (V) mm
Driver Element a-Si TFT active matrix - -
Pixel Number 1920 x R.G.B. x 1200 pixel -
Pixel Pitch 0.2865 (H) x 0.2865 (V) mm -
Pixel Arrangement RGB vertical stripe - -
Display Colors 16.7M color -
Transmissive Mode Normally White - -
Surface Treat ment Hard coating (3H), Glare (LR< 3%) - -
(1)
1.5 MECHANICAL SPECIFICATIONS
Item Min. Typ. Max. Unit Note
Horizontal(H) 577.8 578.3 578.8 mm
Module Size
Note (1) Please refer to the attached drawings for more information of front and back outline dimensions.
Vertical(V) 368.35 368.85 369.35 mm
Depth(D) 22.0 22.5 23.0 mm
Weight - - 4080 g -
4 / 26
(1)
Version 1.0
Page 5
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
A
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item Symbol
Storage Temperature TST -20 60 ºC (1)
Operating Ambient T emperature TOP 0 50 ºC (1), (2)
Shock (Non-Operating) S
Vibration (Non-Operating) V
LCD Cell Life Time L
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta ≦ 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
- 50 G (3), (5)
NOP
- 1.5 G (4), (5)
NOP
50,000 - Hrs
CELL
Min. Max.
Value
Unit Note
MTBF
based
Note (2) The temperature of panel display surface area should be 0 ºC Min. and 60 ºC Max.
Note (3) 11ms, half sine wave, 1 time for ± X, ± Y, ± Z.
Note (4) 10 ~ 300 Hz, 10min/cycle, 3 cycles each X, Y, Z.
Note (5) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
The fixing condition is shown as below:
t Room Temperature
Side Mount Fixing Screw
Gap=2mm
Bracket
LCD Module
Side Mount Fixing Screw
Stage
5 / 26
Version 1.0
Page 6
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
2.2 ELECTRICAL ABSOLUTE RATINGS
2.2.1 TFT LCD MODULE
Item Symbol
Power Supply Voltage Vcc -0.3 +6.0 V (1)
Min. Max.
2.2.2 BACKLIGHT UNIT
Item Symbol
Lamp Voltage VL -- 2.5K V
Lamp Current IL 3.0 8.0 mA
Lamp Frequency FL -- 80 KHz (1),(2)
Note (1) Permanent damage to the device may occur if maximum values are exceeded. Function operation
should be restricted to the conditions described under Normal Operating Conditions.
Min. Max.
Value
Value
Unit Note
Unit Note
(1), (2)
RMS
RMS
(1), (2)
Note (2) Specified values are for lamp (Refer to 3.2 for further information).
6 / 26
Version 1.0
Page 7
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Doc No.:
Issued Date: Aug. 28, 2008
Model No.: M260J3-L05
Preliminary
3. ELECTRICAL CHARACTERISTICS
3.1 TFT LCD MODULE Ta = 25 ± 2 ºC
Parameter Symbol
Min. Typ. Max.
Power Supply Voltage Vcc 4.5 5.0 5.5 V -
Ripple Voltage VRP - - 100 mV -
Rush Current I
Power Supply Current
Power Consumption P
RUSH
White (0.6) (0.75) A (3)a
Black (1.1) (1.3) A (3)b
Vertical Stripe
-
-
-
LCD
3 A (2)
(1.08) (1.2) A (3)c
(5.5) (6.5) Watt (4)
LVDS differential input voltage Vid 100 - 600 mV
LVDS common input voltage Vic - 1.2 - V
Note (1) The module should be always operated within above ranges.
Note (2) Measurement Conditions:
Value
Unit Note
+5.0V
R1
47K
Q1 2SK1475
FUSE
C3
1uF
Vcc
(LCD Module Input)
(High to Low)
(Control Signal)
SW
+12V
C1
1uF
VR1
R2
1K
47K
0.01uF
Q2
2SK1470
C2
Vcc rising time is 470µs
Vcc
0.9Vcc
0.1Vcc
GND
470µs
7 / 26
Version 1.0
Page 8
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
Note (3) The specified power supply current is under the conditions at Vcc = 5.0 V, Ta = 25 ± 2 ºC, fv = 60
Hz, whereas a power dissipation check pattern belo w is displayed.
a. White Pattern
Active Area
c. Vertical Stripe Pattern
b. Black Pattern
Active Area
R
G
R
B
G
R
B
G
RR
G
B
B
B
B
R
R
R
G
G
G
G
B
B
B
B
R
R
Note (4) The power consumption is specified at the pattern with the maximum current.
Active Area
8 / 26
Version 1.0
Page 9
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Doc No.:
Issued Date: Aug. 28, 2008
Model No.: M260J3-L05
Preliminary
3.2 BACKLIGHT UNIT Ta = 25 ± 2 ºC
Parameter Symbol
Min. Typ. Max.
Lamp Input Voltage VL 864 960 1056 V
Lamp Current IL 3.0 7.0 8.0 mA
Lamp Turn On Voltage VS
1760(0 )℃
1620(25 )℃V
Operating Frequency FL 40 55 80 KHz (3)
Lamp Life Time LBL 50,000 Hrs (5), IL = 7.0mA
Power Consumption PL 26 W (4), IL = 7.0 mA
Note (1) Lamp current is measured by current amplify & oscilloscope as shown below:
LCD
Module
HV (Pink)
LV (White)
HV (Blue)
LV (Black)
Value
1
2
A
Inverter
Unit Note
I
RMS
RMS
(2)
V
RMS
(2)
RMS
= 7.0 mA
L
(1)
A
Current Meter
YOKOGAWA 2016
1
2
A
Ta = 25 ± 2 ºC
Note (2) The voltage that must be larger than Vs should be applied to the lamp for more than 1 second
after startup. Otherwise, the lamp may not be turned on normally.It is the value output voltage of
NF circuit.
Note (3) The lamp frequency may produce interference with horizontal synchronization frequency from the
display, which might cause line flow on the display. In order to avoid interference, the lamp
frequency should be detached from the horizontal synchronization frequency and its harmonics as
far as possible.
Note (4) P
= IL × VL × 4
L
Note (5) The lifetime of lamp can be defined as the time in which it continues to operate under the condition
Ta = 25 ±2
o
C and IL = 5.0 mArms until one of the following events occurs:
(a) When the brightness becomes or lower than 50% of its original value.
(b) When the effective ignition length becomes ≦ 80% of its original value.
(The effective ignition length is a scope that luminance is over 70% of that at the center point.)
Note (6) The waveform of the voltage output of inverter must be area-symmetric and the design of the
inverter must have specifications for the modularized lamp. The performance of the Backlight,
such as lifetime or brightness, is greatly influenced by the characteristics of the DC-AC inverter for
the lamp. All the parameters of an inverter should be carefully designed to avoid producing too
much current leakage from high voltage output of the inverter. When designing or ordering the
inverter please make sure that a poor lighting caused by the mismatch of the Backlight and the
inverter (miss-lighting, flicker, etc.) never occurs. If the above situation is confirmed, the module
9 / 26
Version 1.0
Page 10
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
should be operated in the same manners when it is installed in your instrument.
The output of the inverter must have symmetrical (negative and positive) voltage waveform and
symmetrical current waveform.(Unsymmetrical ratio is less than 10%) Please do not use the inverter
which has unsymmetrical voltage and unsymmetrical current and spike wave. Lamp frequency may
produce interface with horizontal synchronous frequency and as a result this may cause beat on the
display. Therefore lamp frequency shall be as away possible from the horizontal synchronous
frequency and from its harmonics in order to prevent interference.
Requirements for a system inverter design, which is intended to have a better display performance, a
better power efficiency and a more reliable lamp. It shall help increase the lamp lifetime and redu ce its
leakage current.
a. The asymmetry rate of the inverter waveform should be 10% below;
b. The distortion rate of the waveform should be within √2 ± 10%;
c. The ideal sine wave form shall be symmetric in positive and negative polarities
* Asymmetry rate:
I p
I -p
| I
* Distortion rate
I
– I –p | / I
p
(or I –p) / I
p
rms
rms
* 100%
10 / 26
Version 1.0
Page 11
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
10 RXO3- Negative LVDS differential data input. Channel O3(odd)
11 RXO3+ Positive LVDS differential data input. Channel O3 (o dd)
12 RXE0- Negative LVDS differential data input. Channel E0 (even)
13 RXE0+ Positive LVDS differential data input. Channel E0 (even)
14 GND Ground
15 RXE1- Negative LVDS differential data input. Channel E1 (even)
16 RXE1+ Positive LVDS differential data input. Channel E1 (even)
17 GND Ground
18 RXE2- Negative LVDS differential data input. Channel E2 (even)
19 RXE2+ Positive LVDS differential data input. Channel E2 (even)
20 RXEC- Negative LVDS differential clo ck input. (even)
21 RXEC+ Positive LVDS differential clock input. (even)
22 RXE3- Negative LVDS differential data input. Channel E3 (even)
23 RXE3+ Positive LVDS differential data input. Channel E3 (even)
24 GND Ground
25 NC Not connection, this pin should be open.
26 NC Not connection, this pin should be open.
27 Vcc +5.0V power supply
28 Vcc +5.0V power supply
29 Vcc +5.0V power supply
30 Vcc +5.0V power supply
Note (1) Connector Part No.: STARCONN 093G30-B0001A or JAE FI-X30SSL-HF.
Note (2) The first pixel is odd.
Note (3) Input signal of even and odd clock should be the same timing.
12 / 26
Version 1.0
Page 13
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
5.2 LVDS DATA MAPPING TABLE
L VDS Channel O0
L VDS Channel O1
L VDS Channel O2
L VDS Channel O3
L VDS Channel E0
L VDS Channel E1
L VDS Channel E2
L VDS Channel E3
LVDS output D7 D6 D4 D3 D2 D1 D0
Data order OG0 OR5 OR4 OR3 OR2 OR1 OR0
LVDS output D18 D15 D14 D13 D12 D9 D8
Data order OB1 OB0 OG5 OG4 OG3 OG2 OG1
LVDS output D26 D25 D24 D22 D21 D20 D19
Data order DE NA NA OB5 OB4 OB3 OB2
LVDS output D23 D17 D16 D11 D10 D5 D27
Data order NA OB7 OB6 OG7 OG6 OR7 OR6
LVDS output D7 D6 D4 D3 D2 D1 D0
Data order EG0 ER5 ER4 ER3 ER2 ER1 ER0
LVDS output D18 D15 D14 D13 D12 D9 D8
Data order EB1 EB0 EG5 EG4 EG3 EG2 EG1
LVDS output D26 D25 D24 D22 D21 D20 D19
Data order DE NA NA EB5 EB4 EB3 EB2
LVDS output D23 D17 D16 D11 D10 D5 D27
Data order NA EB7 EB6 EG7 EG6 ER7 ER6
5.3 BACKLIGHT UNIT:
Pin Symbol Description Remark
1-1 HV High Voltage Pink
1-2 LV Low Voltage White
2-3 HV High Voltage Blue
2-4 LV Low Voltage Black
Note (1) Connector Part No.: YEONHO 35001HS-02L or equivalent
13 / 26
Version 1.0
Page 14
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
5.4 COLOR DATA INPU T ASSIGNMENT
The brightness of each primary color (red, green and blue) is based on the 8-bit gray scale data input for
the color. The higher the binary input, the brighter the color. The table below provides the assignment of
color versus data input.
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
θ
y
y
θx−
θx+
θ
θ
y
Doc No.:
Issued Date: Aug. 28, 2008
Model No.: M260J3-L05
Preliminary
Note (1) Definition of Viewing Angle (θx, θy):
Normal
x =
= 0º
θy-θy+
θX- = 90º
6 o’clock
θ
- = 90º
x-
y-
Note (2) Definition of Contrast Ratio (CR):
The contrast ratio can be calculated by the following expression.
Contrast Ratio (CR) = L255 / L0
L255: Luminance of gray level 255
L 0: Luminance of gray level 0
CR = CR (1)
CR (X) is corresponding to the Contrast Ratio of the point X at Figure in Note (6).
12 o’clock direction
y+
+ = 90º
x+
θX+ = 90º
Note (3) Definition of Response Time (T
100%
90%
Optical
Response
Gray Level 255
10%
0%
, TF):
R
Gray Level 255
Gray Level 0
T
R
T
F
66.67ms 66.67ms
18 / 26
Version 1.0
Page 19
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
500
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point
LC = L (1)
L (x) is corresponding to the luminance of the point X at Figure in Note (6).
Note (5) Measurement Setup:
The LCD module should be stabilized at given temperature for 30 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 30 minutes in a windless room.
LCD Module
LCD Panel
USB2000
Center of the Screen
CS-1000T
Light Shield Room
mm
(Ambient Luminance < 2 lux)
19 / 26
Version 1.0
Page 20
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
X
A
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
Note (6) Definition of White Variation (δW):
Measure the luminance of gray level 255 at 13 points
Year: 2001=1, 2002=2, 2003=3, 2004=4…
Month: 1~12=1, 2, 3, ~, 9, A, B, C
Day: 1~31=1, 2, 3, ~, 9, A, B, C, ~, T, U, V
23 / 26
Version 1.0
Page 24
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Issued Date: Aug. 28, 2008
Doc No.:
Model No.: M260J3-L05
Preliminary
(e) FAB ID(UL Factory ID):
Region Factory ID
TWCMO GEMN
NBCMO LEOO
NBCME CANO
NHCMO CAPG
10. PRECAUTIONS
10.1 ASSEMBL Y AND HANDLING PRECAUTIONS
(1) Do not apply rough force such as bending or twisting to the module during assembly.
(2) To assemble or install module into user’s system can be only in clean working areas. The dust and oil
may cause electrical short or worsen the polarizer.
(3) It’s not permitted to have pressure or impulse on the module because the LCD panel and Backlight will
be damaged.
(4) Always follow the correct power sequence when LCD module is connecting and operating. This can
prevent damage to the CMOS LSI chips during latch-up.
(5) Do not pull the I/F connector in or out while the module is operating.
(6) Do not disassemble the module.
(7) Use a soft dry cloth without chemicals for cleaning, because the surface of polarizer is very soft and
easily scratched.
(8) It is dangerous that moisture come into or contacted the LCD module, because moisture may damage
LCD module when it is operating.
(9) High temperature or humidity may reduce the performance of module. Please store LCD module within
the specified storage conditions.
(10) When ambient temperature is lower than 10ºC may reduce the display quality. For example, the
response time will become slowly, and the starting voltage of CCFL will be higher than room
temperature.
10.2 SAFETY PRECAUTIONS
(1) The startup voltage of Backlight is approximately 1000 Volts. It may cause electrical shock while
assembling with inverter. Do not disa ssemble the module or insert anything into the Backlight unit.
(2) If the liquid crystal material leaks from the panel, it should be kept away from the eyes or mouth. In
case of contact with hands, skin or clothes, it has to be washe d away thoroughly with soap.
(3) After the module’s end of life, it is not harmful in case of normal operation and storage.
10.3 OTHER
When fixed patterns are displayed for a long time, remnant image is likely to occur.
24 / 26
Version 1.0
Page 25
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Page 26
Global LCD Panel Exchange Center
www.panelook.com
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.