Chief PAC502B Users Guide

Page 1
INSTALLATION INSTRUCTIONS
IN-WALL ENCLOSURE
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
PAC502
Page 2
PAC502 Installation Instructions
DISCLAIMER
Milestone AV Technologies, and its affiliated corporations and subsidiaries (collectively, "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.
Chief® is a trademark of Milestone AV Technologies. All rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting system such as a video camera, CPU, screen, display, projector, etc.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this accessory is attached can support the combined weight of the box and all equipment not to exceed 150 lbs (68.0 kg).
NOTES:
It is the installer’s responsibility to ensure that the enclosure is bonded to the ground in the switch box, in accordance with the National Electric Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. A green grounding screw is provided in the enclosure for the purpose, if required.
The equipment shall be installed and assembled by qualified service personnel.
Spacings - To ensure safe operation of the equipment installed in the enclosure, per National Electric Code ANSI/NFPA 70, a minimum separation between power cords and signal or communication cables may be required.
This Cabinet System accessory is for use with Listed wall mounting systems. Refer to the individual mounting system’s installation instructions for compatibility.
--SAVE THESE INSTRUCTIONS--
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all accessories are properly assembled and installed using the instructions provided.
WARNING: Failure to provide adequate structural strength
for this accessory can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this accessory is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the accessory. The wall to which the accessory is being attached may have a maximum drywall thickness of 5/8” (1.6cm).
2
Page 3
Installation Instructions PAC502
1.75
44.5
GROUN DING
SCREWS
20 X 5/ 1 6"- 1 8 THR E A D S
30.00 762
508
20.00
2.50
63.5
12X
3.5
.136
3.946X 100
41.3
1.63
4X
1.98
50.3
1.26 32
152.4
6.00
6.00
152.4
3.85
97.9
3.63
92.1
1" AND 2 " TRADE SI ZE
PIPE CONDUIT
1.39
35.2
2.992X 76
55.9
2.20
87
3.432X
94.7
3.732X
2X 2X
8X
.14
3.5
6.00
152.4
2X
44.5
152.4
6.006X
1.75
8X
.39
9.9
44.5
12.00
304.8
1.754X
4X
2X
19.4
.77
2X 4.00
101.6
NOTES:
EL ECT R ICAL C UTO UTS:1.
SINGLE G ANG RACO 590, • STE EL CITY C Y1/2, OR SIMILAR S TYLE ELECTRICAL BOX 1" A ND 2" TRADE SIZE PIPE
CONDUIT PRODUCT WORKS WITH PXRUB, 2. PNRIW A ND PWRIW WHEN FULLY RETRACTED, 3. DIS T ANCE EACH ASSEM B LY PROTRUDES FROM FRONT EDGE OF PAC-502:
PXRUB - 0. 98" [25MM]
PNRIW - 0.62" [16MM]
PWRIW - 0.50" [1 3MM]• TRIM (NOT INCLUDED WITH THI S 4. PRODUCT ) HA S A WI DTH OF 1 INCH
DIMENSIONS: INCHES [MILLIMETERS]
Tighten Fastener
Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme
Pencil Mark
Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon
Drill Hole
Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou
Hex-Head Wrench
Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale
DIMENSIONS
LEGEND
3
Page 4
PAC502 Installation Instructions
3/16"
B (4) [Mounting spacers]
C (8) M7 x 40mm
D (4) M7 x 50mm
E (6)
08 x 1/2" [Extras if needed for installing electrical box]
F (1)
M4 [Allen driver bit]
G (4 - 2 long, 2 short) [Trim pieces]
K (16) [Tape squares]
H (4) [Cable tie mounts]
J (12) [5-1/2" cable tie]
L (4) [9/16"]
Grounding screw and washer installed at factory
Earthing symbol IEC 60417 No. 5019 affixed adjacent to grounding terminal.
A (1) [PAC502]
TOOLS REQUIRED FOR INSTALLATION
PARTS
4
Page 5
Installation Instructions PAC502
Wood Studs
(A)
Horizontal Framing
Support Blocks
Top View
Wood Screws
(5 places) (Typical for each support block)
INSTALLATION
WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEAT H OR SERIOUS PERSONAL INJURY! This accessory should be installed by qualified personnel.
Site Preparation
Locate and Prepare Mount ing Site
1. Identify a suitable wall location for the in-wall enclosure.
IMPORTANT ! : The PAC502 is designed for in-wall installation spanning a minimu m of three wood studs, 1 6" on center. Installation of PAC502 in 2 x 4 wall results in nearly direct contact with vertical studs and back wall. Inadequate space will remain for electrical wires/cables, plumbing, ductwork, or insulation. Locate installation accordingly.
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! AL W AYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting, drilling, or installing fasteners.
Frame Housing
The exposed portion of the center wood stud must be removed and the resulting cavity completely framed with wood. The following steps are suggested. The actual procedure is dependent upon the specific installation.
WARNING: STRUCTURAL FAILURE HAZARD! FAILURE
TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO DEA T H OR SERI OUS INJURY! Ensure removal of center stud will not cause unacceptable loss of structural strength. Consult a qualified building contractor and applicable building codes.
1. Remove exposed portion of center wood stud flush with upper and lower drywall edges.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surfaces is free of gas, water, waste, or any other plumbing before cutting, drilling, or installing fasteners.
2. Using a stud sensor, locate and mark studs.
3. Center and level housing between marked studs.
4. Using PAC502 (A) as a template, draw pencil line completely around in-wall enclosure. (See Figure 1)
5. Cut drywall on outside edge of line and remove.
Figure 1
Figure 2
2. Cut four 8" long support blocks out of 2" x 4" wood.
3. Using three #10 x 2-1/2" countersunk wood screws (not provided), attach each support block to the studs (See Figure 2)
NOTE: Ensure screws are far enough from block end to
prevent interference with framing screws installed in In­Wall Enclosure Installation section.
4. If necessary, cut rectangular hole in horizontal framing to accommodate the PAC-GB1 Listed electrical box accessory (not included).
5. Attach horizontal framing to each support block with two #10 x 2-1/2" countersunk wood screws (not provided). (See Figure 2)
In-Wall Enclosure Installation
1. Install PAC-GB1 Listed electrical box accessory (not included) into the PAC502 (A) following instructions included with the PAC-GB1.
2. Connect electrical wiring according to National Electrical Code (NEC) ANSI/NFPA 70 - 2008, wire connection requirements.
3. Route audio/visual cables into housing.
5
Page 6
PAC502 Installation Instructions
(A)
5
6
x 4
(D) x 4
(B) x 4
8
(C) x 8
7
x 8
Grounding Lug Locations
4. Center PAC502 (A) in opening and insert into opening. Align front of box with front face of wall. (See Figure 3)
Figure 3
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! AL W AYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting, drilling, or installing fasteners.
5. Drill four 3/16" diameter pilot holes in studs at side mounting holes. (See Figure 4)
6. Attach the P AC502 (A) to side studs using four M7 x 50mm Allen head connector screws (D) and mounting spacers (B) using an M4 Allen head drill bit (F). (See Figure 4)
NOTE:
7. Drill eight 3/16" diameter pilot holes in horizontal framing at
8. Attach the P AC502 (A) to horizontal framing using eight
The PAC502 has 1/2" total clearance between the two studs. The spacers allow side to side adjustment.
top and bottom mounting holes. (See Figure 5)
M7 x 40mm Allen head connector screws (C) using an M4 Allen head drill bit (F). (See Figure 5)
Figure 5
DANGER: IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be installed by qualified personnel using a UL Recognized No. 12AWG Green and Yellow grounding wire connected to grounding lug on mount.
6
Figure 4
Figure 6
Page 7
Installation Instructions PAC502
(G) x 4
3
(K) x 16
1
Trim Kit (Option al)
1. Remove paper covering adhesive and affix three tape
squares (K) to inside lower flange of each trim piece (G). (See Figure 7)
2. Orient trim pieces (G). (See Figure 7)
3. Remove paper covering adhesive back from tape squares
(K) on trim and press trim (G) against inner wall of box. (See Figure 7)
Figure 7
Installing Mount Assembly
1. Install mount assembly following instructions included with
the mount.
2. OPTIONAL: Cover unused mounting holes in PAC502 with
9/16" caps (L).
Cable Management
1. Attach all cables to display.
2. If necessary, use cable tie mounts (H) and cable ti es (J) to
secure cables within PAC502.
7
Page 8
PAC502 Installation Instructions
Chief, a products division of Milestone AV Technologies
8807-002019 Rev04 2016 Milestone AV Technologies
www.milestone.com
04/16
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000 F 877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P +31 (0) 495 580 852 F +31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099 F 852 2145 4477