Chief PAC501B Users Guide

Page 1
I N S T A L L A T I O N I N S T R U C T I O N S
IN-WALL ENCLOSURE
Spanish Product Description German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
PAC501
Page 2
PAC501 Installation Instructions
DISCLAIMER
Milestone AV Technologies, and its affiliated corporations and subsidiaries (collectively, "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.
Chief® is a trademark of Milestone AV Technologies. All rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting system such as a video camera, CPU, screen, display, projector, etc.
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this accessory is attached can support the combined weight of the box and all equipment not to exceed:
Wood Stud: 200 lbs. (90.7 kg)
Steel Stud: 138 lbs. (62.6 kg)
WARNING: Use this accessory only for its intended use as
described in these instructions. Do not use attachments not recommended by the manufacturer.
WARNING: Never operate this accessory if it is damaged.
Return the accessory to a service center for examination and repair.
WARNING: Do not use this product outdoors.
NOTES:
It is the installer’s responsibility to ensure that the enclosure is bonded to the ground in the switch box, in accordance with the National Electric Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1. A green grounding screw is provided in the enclosure for the purpose, if required.
The equipment shall be installed and assembled by qualified service personnel.
Spacings - To ensure safe operation of the equipment installed in the enclosure, per National Electric Code ANSI/NFPA 70, a minimum separation between power cords and signal or communication cables may be required.
This Cabinet System accessory is for use with Listed wall mounting systems. Refer to the individual mounting system’s installation instructions for compatibility.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all accessories are properly assembled and installed using the instructions provided.
WARNING: Failure to provide adequate structural strength
for this accessory can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this accessory is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the accessory. The wall to which the accessory is being attached may have a maximum drywall thickness of 5/8” (1.6cm).
2
IMPORTANT ! : The PAC501 is designed for in-wall
installation spanning three wood or steel studs 16" on center, and is to be used with a Listed Chief PNRIW Series large in­wall swing arm wall mount (not included).
NOTE: The PAC501 has been designed to accommodate two
UL Listed electrical box accessories (not included).
--SAVE THESE INSTRUCTIONS--
Page 3
Installation Instructions PAC501
2X
25.9 0
HAS A WIDT H OF 1 INC H
DIMENSIONS
657. 7 2X 22.9 0
8X .136
3.45
2X 2.00
50.8
1.75 0
44.4 5
2X 5.89
149. 7
2X 12.0 0
304. 8
3.92 5
3.42 5
2X 18 .00
457. 2 2X 28.0 0
711. 2
581. 5
2X 1.3 8
34.9
2X 2.38
60.3
8X .39 0
9.9
8X .13 6
3.5
ELECTRICAL CUTOUT
DESIGNED TO FIT A SINGLE GANG
RACO 590, STEEL CITY CY 1/2 OR
SIMILAR STYLE ELECTRICAL BOX
3.85
97.9
4X 1.88
47.6
4X .765
19.4
2X 4.00
101.6
18.0 4
458. 2
2X 2.00
50.8
.98
24.9
NOTE: TRIM (N OT INCLU DED WITH PRODUCT )
LEGEND
GROUND ING SCREW CONNEC TIONS
8.500
215.9
2.500
63.5
30.0 0 762
12X 5/16"-18 THREADS
Tighten Fastener
Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations
3.93 8 100
4.03 1
102. 4
1.980
50.3
8.000
203.2
6.000
152.4
304. 8
20.0 0 508
2 X 12.0 0
DIMENSIONS: [MILLIMETERS] INCHES
Pencil Mark
Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon
Drill Hole
Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou
Phillips Screwdriver
Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme
Hex-Head Wrench
Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale
3
Page 4
PAC501 Installation Instructions
TOOLS / HARDWARE REQUIRED FOR INSTALLATION
PARTS
3/16"
Grounding screw and washer installed at factory
Earthing symbol IEC 60417 No. 5019 affixed adjacent to grounding terminal.
#10 x 2-1/2" countersunk wood screws (Qty. 20)
2" x 4" wood for framing and support blocks (wood
HARDWARE REQUIRED
(not included)
(wood studs)
studs)
jamb-studs and cripple studs for steel stud framework
2 1/2" drywall screws (Qty. 16) for steel stud framework
C (8) M7 x 40mm
D (4) M7 x 50mm
A (1) [PAC501]
B (4) [Mounting Spacers]
F (6)
08 x 1/2" [Extras if needed for installing electrical box]
E (1)
[M4 Allen driver bit]
4
Page 5
Installation Instructions PAC501
INSTALLATION
WARNING: DO NOT INSTALL THIS ACCESSORY IN A
FIREWALL. Contact your local building inspector before cutting a hole in the drywall if unsure.
WARNING: IMPROPER INSTALLATION CAN RESULT IN
DEATH OR SERIOUS PERSONAL INJURY! This accessory should be installed by qualified personnel.
Locate and Prepare Mounting Site
1. Identify a suitable wall location for the in-wall enclosure.
IMPORTANT ! : The PAC501 is designed for in-wall
installation spanning a minimum of three wood or steel studs, 16" on center. Installation of PAC501 in 2" x 4" wall results in nearly direct contact with vertical studs and back wall. Inadequate space will remain for electrical wires/cables, plumbing, ductwork, or insulation. Locate installation accordingly.
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting, drilling, or installing fasteners.
Frame Housing Wood Studs
The exposed portion of the center wood stud must be removed and the resulting cavity completely framed with wood. The following steps are suggested. The actual procedure is dependent upon the specific installation.
WARNING: STRUCTURAL FAILURE HAZARD! FAILURE
TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO DEATH OR SERIOUS INJURY! Ensure removal of center stud will not cause unacceptable loss of structural strength. Consult a qualified building contractor and applicable building codes.
1. Remove exposed portion of center wood stud flush with upper and lower drywall edges.
Support Blocks
Horizontal Framing
Top View
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surfaces is free of gas, water, waste, or any other plumbing before cutting, drilling, or installing fasteners.
2. Using a stud sensor, locate and mark studs.
3. Center and level housing between marked studs.
4. Using PAC501 (A) as a template, draw pencil line completely around housing. (See Figure 1)
5. Cut drywall on outside edge of line and remove.
Wood/Steel Studs
Wood screws (not included)
(5 places) (Typical for each support block)
Figure 2
2. Cut four 8" long support blocks out of 2" x 4" wood.
3. Using three #10 x 2-1/2" countersunk wood screws (not included), attach each support block to the studs (See Figure 2)
NOTE: Ensure screws are far enough from block end to
prevent interference with framing screws installed in In­Wall Enclosure Installation section.
4. If necessary, cut rectangular hole in horizontal framing to accommodate a UL Listed electrical box accessory (not included).
5. Attach horizontal framing to each support block with two #10 x 2-1/2" countersunk wood screws (not included). (See Figure 2)
6. Proceed to "In-Wall Enclosure Installation" section.
Figure 1
(A)
5
Page 6
PAC501 Installation Instructions
Site Requirements (Steel Studs)
16" (on center) Studs
PAC501 Installation Location
(Must be centered over three studs)
If back side of wall is unfinished, drywall must be installed to a minimum of one stud left and right of the studs being used to install the mount. Drywall must be secured to studs with screws 12" on center
Drywall
**1/2" minimum
Drywall Thickness
(Both Sides of Stud)
**See hazard statement
on page 2!
FRONT
There must be a minimum of 1-7/8" (48mm) clearance inside wall
Steel Stud (2 x 4 / 25ga minimum) Stud type and structural strength must conform to the North American Specification for the Design of Cold-Formed Steel Structural Members.
[362, 125 18, C-Shape, S - Stud Section]
6
Page 7
Installation Instructions PAC501
Steel Studs
The exposed portion of the center steel stud must be removed and the resulting cavity completely framed with steel. The following steps are suggested. The actual procedure is dependent upon the specific installation. Refer to the Gypsum Construction Handbook, Framing - Door and Window Openings Section for complete details and instructions.
WARNING: STRUCTURAL FAILURE HAZARD! FAILURE
TO TAKE ADEQUATE PRECAUTIONS CAN LEAD TO DEATH OR SERIOUS INJURY! Ensure removal of center stud will not cause unacceptable loss of structural strength. Consult a qualified building contractor and applicable building codes.
1. Remove exposed portion of center steel stud flush with upper and lower drywall edges.
Jamb Studs
anchor
to runner
Horizontal Framing
In-Wall Enclosure Installation
1. Install UL Listed electrical box accessory (not included) into the PAC501 (A) following instructions included with the UL Listed electrical box.
2. Connect electrical wiring according to National Electrical Code (NEC) ANSI/NFPA 70 - 2008, wire connection requirements.
3. Route audio/visual cables into housing.
4. Center PAC501 (A) in opening and insert into opening. Align front of box with front face of wall. (See Figure 4)
(A)
Drywall
anchor
to runner
Screws (not included) (4 places)
(Typical for each
jamb stud)
Figure 3
2. Cut four 8" long jamb studs out of 25 ga steel stud material.
3. Using two 2 1/2" drywall screws (not included), attach each jamb stud to the studs (See Figure 3)
NOTE: Ensure screws are far enough from block end to
prevent interference with framing screws installed in In­Wall Enclosure Installation section.
4. If necessary, cut rectangular hole in horizontal framing to accommodate a UL Listed electrical box accessory (not included).
5. Attach 25 ga horizontal steel runner header framing to each jamb stud with 2 1/2" drywall screws (not included). (See Figure 3)
Figure 4
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL WIRES OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surfaces is free of electrical wires and cables before cutting, drilling, or installing fasteners.
5. Drill four 3/16" diameter pilot holes in studs at side mounting holes. (See Figure 4)
6. Attach the PAC501 (A) to side studs using four M7 x 50mm Allen head connector screws (D) and mounting spacers (B) using an M4 Allen head drill bit (E). (See Figure 5)
7
Page 8
PAC501 Installation Instructions
6
x
5
x 4
(D) x 4
(B) x 4
Figure 5
NOTE: The PAC501 has 1/2" total clearance between the two
studs. The spacers allow side to side adjustment.
7. Drill eight 3/16" diameter pilot holes in horizontal framing at top and bottom mounting holes. (See Figure 6)
8. Attach the PAC501 (A) to horizontal framing using eight M7 x 40mm Allen head connector screws (C) using an M4 Allen head drill bit (E). (See Figure 6)
DANGER: IMPROPER WIRING CAN LEAD TO DEATH
OR SEVERE PERSONAL INJURY! Grounding must be installed by qualified personnel using a UL Recognized No. 12AWG Green and Yellow grounding wire connected to grounding lug on mount.
Grounding Lug Locations
Figure 7
Installing Arm Kit
7
8
(C) x 8
x 8
Figure 6
Install arm kit following instructions included with the kit.
8
Page 9
Installation Instructions PAC501
9
Page 10
PAC501 Installation Instructions
10
Page 11
Installation Instructions PAC501
11
Page 12
PAC501 Installation Instructions
Chief, a products division of Milestone AV Technologies
8800-003091 Rev00 2018 Milestone AV Technologies
www.milestone.com
08/18
USA/International A 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000 F 877.894.6918 / 952.894.6918
Europe A Franklinstraat 14, 6003 DK Weert, Netherlands
P +31 (0) 495 580 852 F +31 (0) 495 580 845
Asia Pacific A Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099 F 852 2145 4477