INSTALLATION INSTRUCTIONS
PAC-125 with mount (not included) installed.
CAUTION!
CAUTION!
Lateral Shift Accessory Model: PAC-125/PAC-126
The PAC-125 Lateral Shift Accessory is for use with Chie f Model PSM, PST, PRO, PLP, Large Flat Panel Display wall mounts. It can be installed on either a 16" or 24" on-center stud systems, and includes seven mounting holes at 4" intervals. The PAC-125 is also grooved for drilling at other intervals.
BEFORE YOU BEGIN
The instructions provided in this document outline the installation of the PAC-125 Lateral Shift Accessory to specific Chief mounts. If you have questions regarding the use or installation of this accessory, contact a Chief Customer Service representative at 1-800-582-6480 before proceeding with the installation.
To prevent damage to the Kit, which could affect or void the Factory warranty, and to the equipment that will be attached to it, thoroughly study all instructions and illustrations before you begin the installation.
CHIEF MANUFACTURING INC.
1-800-582-6480 952-894-6280 FAX 952-894-6918 8401 EAGLE CREEK PARKWAY, STE 700 SAVAGE, MINNESOTA 55378 USA
8800-000059 Rev B
©2006 Chief Manufacturing
www.chiefmfg.com
Page 2
Model: PAC-125/PAC-126 Installation Instructions
WARNING!
WARNING!
CAUTION!
(PAC-126)
(PAC-125)
IMPORTANT WARNINGS AND CAUTIONS!
WARNING: A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions. CAUTION: A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPROPER INSTALLATION CAN LEAD TO THE MOUNT FALLING. The structure to which the mount is installed must be capable of supporting 4 times the combined weight of this accessory, the mount and the display. If the structural members can not support this weight, reinforce the structural members before installing the mount.
IMPROPER INSTALLATION CAN LEAD TO THE MOUNT FALLING. The load placed on the PAC-150 must not exceed 150 lbs (68.03kg) the maximum weight of the PAC-125 accessory.
Changes or modifications not approved by Chief Manufacturing could void user’s warranty.
2
Figure 1: Dimensions
Page 3
Installation Instructions Model: PAC-125/PAC-126
CAUTION!
Table 1: Parts
ITEM DESCRIPTION QTY*
10 BRACKET, Lateral Shift
PAC-125 28.00" long/PAC-126 36.00" long
2
20 NUT, T-Slot, 5/16-18 4
30 STUD, Threaded, 5/16-18 4
40 WASHER, Lock, 5/16" 4
50 NUT, Hex, 5/16-18 4
60 SCREW, Panhead, Self Tapping, #8 x 1/4" 4
70 WASHER, Flat, 1/4" 4
10
20
30
40
50
60
70
TOOLS REQUIRED FOR INSTALLATION
Drill and Drill bits
Phillips Screw Driver
INSPECT MOUNT BEFORE ASSEMBLY
Carefully inspect components for shipping damage. If damage is apparent, call your carrier claims agent and do not continue with installation until the carrier has reviewed the damage. (see Figure 2)
Figure 2: Parts
3
Page 4
Model: PAC-125/PAC-126 Installation Instructions
WARNING!
CAUTION!
10
20
30
60
This dimension required from mount being installed
Pilot Holes (4 places)
Wood Studs
(16" or 24" on center)
Identified during step 1 plus 2 1/8"
Dimension
ASSEMBLY AND INSTALLATION
Lateral Shift Bracket Assembly
1. Assemble four threaded studs (30) to four T-Slot nuts (20).
2. Slide T-Slot nut assembly into bracket (10) channel.
3. Install four self tapping screws (60) into bracket (10) ends. (see Figure 3)
Figure 4: Identify distance between Vertical
Mounting Holes on mount
4. Locate and mark four pilot hole locations.
5. Drill four pilot holes using drill size specified in Installation Instructions provided with mount being installed.
Figure 3: Install T-Slot Nuts on Lateral Shift Bracket
Installation
IMPROPER INSTALLATION CAN LEAD TO THE MOUNT FALLING. The structure to which the PAC-125 is installed must be capable of supporting 4 times the combined weight of the accessory, the mount and the display.
1. Identify desired mounting location considering:
Structural integrity of desired location.
Length of PAC-125 mounting brackets
Size of display being mounted
2. Determine distance between vertical mounti ng holes on the mount being installed by referring to the Installation Instructions provided with the mount. (see Figure 4)
3. Add 2 1/8" to the dimension identified during step 1.
2 1/8" must be added to the dimension identified during step 1 for proper locating of pilot holes.
Figure 5: Mark and Drill Pilot Holes
6. Position upper bracket against wall with mounting slots up and align with pilot holes. (see Figure 6)
7. Secure upper bracket to wall using hardware specified in installation instructions provided with mount being installed.
8. Position lower bracket against wall with mounting slots up and align with pilot holes. (see Figure 6)
4
9. Secure lower bracket to wall using hardware specified in installation instructions provided with mount being installed.
Page 5
Installation Instructions Model: PAC-125/PAC-126
Pilot Holes (4 places)
Upper Bracket (mounting slots up)
Lower Bracket (mounting slots down)
Mounting Stud
Align with mounting holes in mount
(4 places)
Upper Bracket
Lower Bracket
Mount being installed
70
40
50
12. Place mount onto mounting studs on lateral shift
brackets and secure using four Flat washer s (70), four lock washers (40), and four hex nuts (50). (see Figure 8)
Figure 6: Mount Lateral Shift Brackets on Wall
10. Identify mounting holes in mount being insta lled using the installation instructions provided with the mount.
11. Position mounting studs in upper and lower lateral shift brackets so that they ali gn with mounting holes in mount being installed.
Figure 8: Install Mount to Lateral Shift Brackets
Figure 7: Position Mounting Tabs
5
Page 6
Model: PAC-125/PAC-126 Installation Instructions
6
Page 7
Installation Instructions Model: PAC-125/PAC-126
7
Page 8
Model: PAC-125/PAC-126 Installation Instructions
8
Loading...