Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
OLCB2X1U
OLCB2X1UInstallation Instructions
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
DEFINITIONS
MOUNTING SYSTEM: A MOUNTING SYSTEM is the
primary Chief product to which an accessory and/or component
is attached.
ACCESSORY: AN ACCESSORY is the secondary Chief
product which is attached to a primary Chief product, and may
have a component attached or setting on it.
COMPONENT: A COMPONENT is an audiovisual item
designed to be attached or resting on an accessory or mounting
system such as a video camera, CPU, screen, display,
projector, etc.
OLCB2X1U mounts does not exceed 500 lbs (226.8 kg) total
or 125 lbs (56.7 kg) per display.
125125
125125
NOTE: "Moment" ratings have NOT been evaluated by UL.
WARNING: Exceeding the maximum moment can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the mounting system
does not exceed a moment of 2000 ft-lbs. See table below for
specific column specifications.
COLUMN
MODEL
ODAC0203B
ODAC0304B
ODAC0405B
ODAC0506B
ODAC0708B
Weight
capacity
300 lbs (136 kg)23 min - 36 max2000
300 lbs (136 kg)33 min - 48 max2000
300 lbs (136 kg)45 min - 60 max2000
300 lbs (136 kg)57 min - 72 max2000
300 lbs (136 kg)81 min - 96 max2000
Moment
Length (IN)
(ML)
Max
Design
Moment
(FT-LBS)
(MDM)
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Use this mounting system with other outdoor
products only.
WARNING: Always use two people or a mechanical lifting
device to safely lift and position equipment.
NOTE: The OLCB2X1U flat panel floor/ceiling mounts are
intended to be used with UL Listed ODAC Series
columns (not included): ODAC0203, ODAC0304,
ODAC0405, ODAC0506, ODAC0708.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located within the mounting system of the
2
--SAVE THESE INSTRUCTIONS--
Installation Instructions OLCB2X1U
54.75
DIMENSIONS
1390.7
MAX SCREEN WIDTH
400 mm MOUNTING PATTERN
DIMENSIONS: INCHES
[MILLIMETERS]
0.125
3.2
15.75
400.0
DIMENSIONS: INCHES
[MILLIMETERS]
3
OLCB2X1UInstallation Instructions
DIMENSIONS: INCHES
[MILLIMETERS]
DIMENSIONS:INCHES[MILLIMETERS]
4
Installation Instructions OLCB2X1U
+5°AND -15 °
HOLE LOCKOUT
DIMENSIONS (cont’d)
0° HOLE
LOCKOUT
+7.6° HOLE
LOCKOUT
-5° AND -20°
HOLE LOCKOUT
10°
-10° HOLE
LOCKOUT
1.91
48.4
DIMENSIONS: INCHES
[MILLIMETERS]
5
OLCB2X1UInstallation Instructions
LEGEND
Tighten Fastener
Apretar elemento de fijación
Befestigungsteil festziehen
Apertar fixador
Serrare il fissaggio
Bevestiging vastdraaien
Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación
Befestigungsteil lösen
Desapertar fixador
Allentare il fissaggio
Bevestiging losdraaien
Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips
Kreuzschlitzschraubendreher
Chave de fendas Phillips
Cacciavite a stella
Kruiskopschroevendraaier
Tournevis à pointe cruciforme
Pencil Mark
Marcar con lápiz
Stiftmarkierung
Marcar com lápis
Segno a matita
Potloodmerkteken
Marquage au crayon
Drill Hole
Perforar
Bohrloch
Fazer furo
Praticare un foro
Gat boren
Percez un trou
Opcional
Optional
Opcional
Opzionale
Optie
En option
Security Wrench
Llave de seguridad
Sicherheitsschlüssel
Chave de segurança
Chiave di sicurezza
Veiligheidssleutel
Clé de sécurité
6
Installation Instructions OLCB2X1U
TOOLS REQUIRED FOR INSTALLATION
PARTS
#2
[Interface Bracket Hardware Kit]
(4 bags total - quantities listed per bag)
A (4)
M6x16mm
E (4)
.750x.323x.250
B (4)
M6x25mm
F (4)
.750x.344x.500
C (4)
M8x20mm
G (4)
5/16"
1/2"
9/16"
3/8"
D (4)
M8x30mm
5/32" (included)
[Interface Lockout Bag] - (4) - (Qty per bag)
M (1)
#10-24 x 1/2"
Q (1)
1/4-20
[Box-column Hardware Kit] - (2) - (Qty per bag)
N (1)
1/4-20 x 2"
R (1)
5/16-18
S (2)
5/16"
P (1)
5/16-18 x 2"
T (2)
1/4"
L (8)
[Interface bracket]
H (2)
[Mount assembly]
X (2)
1/4-20 x 1 1/4"
J (2)
[2 x 1 rail]
1/4 x 3/4"
U (2)
3/8-16 x 4"
Y (8)
K (4)
[Side cover]
Z (1)
5/32"
V (2)
3/8-16
W (4)
3/8"
7
OLCB2X1UInstallation Instructions
INSTALLATION
IMPORTANT ! : The following procedure assumes that:
•Two UL Listed ODAC Series Floor/Ceiling
Columns (not included) have been properly
installed following instructions provided with
plates and pipes.
Attaching Mount to ODAC Series Column
CAUTION: WATCH FOR PINCH POINTS! Do not place
fingers between movable parts.
1.Slide mount assemblies (H) onto ODAC Series Floor/
Ceiling Columns. (See Figure 1) or (See Figure 2)
2.Use two 3/8-16 x 4" hex head tapping bolts (U), four 3/8"
washers (W) and two 3/8-16 hex nuts (V) to secure each
mount assembly (H) to each column. (See Figure 1) or (See
Figure 2)
1
(W) x 4
2
(U) x 2
(H)
(to Floor)
(W) x 4
2
2
(U) x 2
(to Ceiling)
2
(V) x 2
Figure 2
1
3.Install 1/4-20 x 1 1/4" button head cap screws (X) into each
mount assembly (H) to prevent column from rattling. (See
Figure 3)
(X) x 2
(V) x 2
(H)
Figure 1
3
(H) x 2
Figure 3
8
Installation Instructions OLCB2X1U
4.Slide 2 x 1 rail (J) onto one of two assemblies (H) attached
to column. (See Figure 4)
(J)
(H)
4
Figure 4
5.Slide 2 x 1 rail (J) onto second assembly (K) attached to
column. (See Figure 5)
6.Use four 1/4 x 3/4" hex flange bolts (Y) to secure two side
covers (K) to ends of rail (J). (See Figure 5)
(K) x 2
(J)
5
6
(Y) x 4
Attaching Interface Brackets to Display
1.Lower the latch mechanism on each interface bracket (L).
(See Figure 7)
(L)
1
Latch
mechanism
Figure 7
2.Align the center of the interface bracket (L) with center of
screen. (See Figure 8)
NOTE: The diamond-shape hole in the bracket corresponds to
the center of the mount.
(E or F)
Figure 5
7.Tighten four bolts on back of each assembly to secure rail
(J) in place.
7
x 4 (per assembly)
Figure 6
8.Repeat Steps 4-7 to install second rail (J) to assemblies (H).
(G)
2
Center of
bracket
3
(A-D) (L)
Figure 8
WARNING: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! Using screws of
improper size may damage your display. Properly sized
screws will easily and completely thread into display
mounting holes. If spacers are required, be sure to use longer
screws of the same diameter.
3.Select correct screws, spacers (if necessary) and washers
from the hardware bag (A-G) and attach brackets (L) to
back of screen. (See Figure 8)
9
OLCB2X1UInstallation Instructions
Attaching Displays to Ceiling Mounts
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located within the mounting system of the
OLCB2X1U mounts does not exceed 500 lbs (226.8 kg) total
or 125 lbs (56.7 kg) per display.
125125
125125
1.Ensure that the latch mechanisms on interface brackets (L)
are already lowered. (See Figure 9)
2.While supporting both sides of display, lower display onto
ceiling mount, hooking top of interface brackets onto front of
ceiling mount. (See Figure 9)
WARNING: IMPROPER INSTALLATION CAN LEAD TO
DISPLAY FALLING CAUSING SERIOUS PERSONAL
INJURY OR DAMAGE TO EQUIPMENT! The display MUST
be centered on the ceiling mount.
5.Repeat Steps 1-4 for other interface brackets.
(OLCM1U shown)
4
(M)
Figure 10
Adjustments
3.Raise the latch mechanism on both interface brackets to
lock bracket in place. (See Figure 9)
(OLCM1U shown)
2
CAUTION: Watch for pinch points! Do not place fingers
between movable parts.
Tilt
CAUTION: Watch for pinch points! Do not place fingers
between movable parts.
The interface brackets allow -7.6° to 20° tilt, and can be locked
at -7.6°, -5°, 0°, 5°, 10°, 15° and 20° tilt. (See Figure 11)
+5°AND -15°
HOLE LOCKOUT
0° HOLE
LOCKOUT
+7.6° HOLE
LOCKOUT
-5° AND -20°
HOLE LOCKOUT
-10° HOLE
LOCKOUT
2.48
63.0
Latch
3
mechanism
Figure 9
4.Fasten bracket against ceiling mount extrusion using one
10-24 x 1/2" socket head cap screw (M) per bracket. (See
Figure 10)
10
1.91
48.4
- 10°
Figure 11
Installation Instructions OLCB2X1U
(Displays not shown)
6.If necessary, loosen button head tilt friction bolt (located on
side of interface bracket). (See Figure 12)
7.Adjust tilt as required. (See Figure 12)
8.The tilt may be locked at -7.6°, -5°, 0°, 5°, 10°, 15° and 20°
using one 1/4-20 x 2" Phillips head screw (N), one 1/4-20
lock nut (Q) and two 1/4" washers (T) per interface bracket.
(See Figure 11) and (See Figure 12)
NOTE: Use of washers (T) is optional.
9.Tighten button head tilt friction bolt as necessary.
4
(T) x 2
6
(N)
0° tilt
(Q)
20° tilt
Tilt
friction
bolt
4
7
Latch Lock/Security
IMPORTANT ! : In order to prevent interface latch from
getting loose due to strong winds, the latch MUST be
locked either using a padlock or locking bolt (N) and 5/
16-18 hex nuts (Q). This is NOT optional!
Using Padlocks (Security)
1.Add padlock (not included) to each interface bracket to lock
latch and to provide security for displays. (See Figure 14)
Padlock
(Optional)
5
Figure 12
Level Adjustment
1.Adjust level adjustment screws to change roll position.The
roll may be adjusted 1" in either direction. (See Figure 13)
or
level adjustment screws
(OLCM1U shown)
Figure 14
Using Bolts/Nuts
NOTE: This will keep latch from opening but does not provide
additional security for the displays.
1.Use 5/16-18 x 2" hex head carriage bolt (P), 5/16-18 hex nut
(R) and two 5/16" washers (S) to lock each interface bracket
latch in place. (See Figure 15)
(P)
(S) x 2
(R)
Figure 13
Figure 15
11
OLCB2X1UInstallation Instructions
Chief, a products division of
Milestone AV Technologies
8800-003023 Rev01
2018 Milestone AV Technologies
www.milstone.com
12/18
USA/InternationalA 6436 City West Parkway, Eden Prairie, MN 55344
P 800.582.6480 / 952.225.6000
F 877.894.6918 / 952.894.6918