CHIEF LTM, LSM User Manual [ru]

INSTALLATION INSTRUCTIONS
Instrucciones de instalación Installationsanleitung Instruções de Instalação
Istruzioni di installazione Installatie-instructies Instructions d´installation
FUSION LARGE HEIGHT ADJUST
FLAT PANEL MOUNTS
Go to http://downloads.chiefmfg.com/MANUALS-I/LSM_LTMSeries-I.pdf for translated instructions.
Переведенные инструкции находятся по адресу http://downloads.chiefmfg.com/MANUALS-I/LSM_LTMSeries-I.pdf
LSM/LTM Series
LSM/LTM Series Installation Instructions
DISCLAIMER
Milestone AV Technologies, and its affiliated corporations and subsidiaries (collectively "Milestone"), intend to make this manual accurate and complete. However, Milestone makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. Milestone makes no representation of warranty, expressed or implied, regarding the information contained herein. Milestone assumes no responsibility for accuracy, completeness or sufficiency of the information contained in this document.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for examination and repair.
WARNING: Do not use this product outdoors.
IMPORTANT ! :
mounted to an 8" concrete, 8"x8"x16" concrete block or 2" x 4" wood studs (16" on center) wall covered by drywall of 5/8" maximum thickness.
The LSM/LTM mounts are designed to be
Chief® is a registered trademark of Milestone AV Technologies. All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury, damage to equipment, or voiding of factory warranty! It is the installer’s responsibility to make sure all components are properly assembled and installed using the instructions provided.
--SAVE THESE INSTRUCTIONS--
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment. Reinforce the structure as required before installing the component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the installer’s responsibility to make sure the combined weight of all components located on the LSM/LTM does not exceed 200 lbs (90.7 kg).
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use attachments not recommended by the manufacturer.
2
Installation Instructions LSM/LTM Series
LTM
DIMENSIONS: [MILLIMETERS]
INCHES
34.57 878.1
1.75 44.5 15.10 383.4
2.92 74.11.00 25.4
.33 8.3
MINIMUM SPACING 12"
RAILS CAN BE SLID LEFT
OR RIGHT FOR OFFSET
20.54 521.7
7.00 177.8
16.52 419.6
5.29 134.5
12°
21.00 533.4
.32 8.1
0
.49 12.5
.98 25
1.48 37.5
1.97 50
2.46 62.5
2.95 75
3.44 87.5
3.94 100
4.43 112.5
4.92
5.91
NOTES:
MAXIMUM MOUNTING PATTERN IS 30.6"[777.2mm] WITHOUT
1.
REVERSING UPRIGHTS.
MAXIMUM MOUNTING PATTERN IS 35.2"[894mm] WITH REVERSING
2.
UPRIGHTS.
FOR RECESSED APPLICATIONS, MINIMUM VE RTICAL LIFT FOR HOOK
3. ENGAGEMENT IS .42"[10.7mm]. MOUNT IS 1.99"[50.5mm] DEEP WHEN FLAT TO WALL.
LSM
DIMENSIONS: [MILLIMETERS]
INCHES
1.00 25.4
.33 8.3
1.75 44.5
2.92 74.1
34.57 878.1
15.10 383.4
1.52 38.5
RAILS CAN BE SLID LEFT
OR RIGHT FOR OFFSET
MINIMUM WALL BRACKET
SPACING 12"
1.96 49.8
16.52 419.6
21.28 540.4
7.00 177.8
21.00 533.4
.53 13.5
.32 8.1
0
.49 12.5
.98 25
1.48 37.5
1.97 50
2.46 62.5
2.95 75
3.44 87.5
3.94 100
4.43 112.5
4.92 125
5.41 137.5
5.91 150
6.40 162.5
6.89 175
7.38 187.5
7.87
NOTES:
MAX MOUNTING PATTERN IS 31.8" (807.7 mm) WIDE
REVERSING UPRIGHTS1.
MAX MOUNTING PATTERN IS 34.3" (871.2 mm) WIDE
REVERSING THE UPRIGHTS2. FOR RECESSED APPLICATIONS, MINIMUM VERTICAL LIFT FOR HOOK ENGAGEMENT IS .56"[14.2].3. MOUNT IS 1.96"[49.8mm] DEEP.
UPRIGHTS
DIMENSIONS
3
Installation Instructions LSM/LTM Series
Tighten Fastener
Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations
Loosen Fastener
Aflojar elemento de fijación Befestigungsteil lösen Desapertar fixador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations
Phillips Screwdriver
Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis à pointe cruciforme
Open-Ended Wrench
Llave de boca Gabelschlüssel Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche
By Hand
A mano Von Hand Com a mão A mano Met de hand À la main
Hex-Head Wrench
Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale
Pencil Mark
Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon
Drill Hole
Perforar Bohrloch Fazer furo Praticare un foro Gat boren Percez un trou
Adjust
Ajustar Einstellen Ajustar Regolare Afstellen Ajuster
Remove
Quitar Entfernen Remover Rimuovere Verwijderen Retirez
Optional
Opcional Optional Opcional Opzionale Optie En option
Security Wrench
Llave de seguridad Sicherheitsschlüssel Chave de segurança Chiave di sicurezza Veiligheidssleutel Clé de sécurité
LEGEND
4
LSM/LTM Series Installation Instructions
7/32" (5.5mm) Wood Stud
#2
5/16" (7.9mm) Concrete
C (6)
E (6)
R (1)
W (1)
X (1)
S (1)
(LTM Only)
U (1) 3/16" - 6"
[A-P included with LSMU/LTMU Models Only]
A (8) M4x16mm
B (6) M4x20mm
M4x25mm
D (6) M5x16mm
M5x20mm
F (6) M5x25mm
G (6) M6x16mm
H (6) M6x25mm
P (1) M5
I (6) M8x20mm
J (6) M8x30mm
K (4) M8x50mm
L (8) .750x.323x.250
M (8) .750x.344x.500
QA (4) 5/16"
QB (4) 5/16"
QC (4) 5/16" x 2-1/2"
V (4)
Y (1)
Z (1)
Custom
LSM5XXX/
LTM5XXX Hardware
[Included with
LSM5XXX/LTM5XXX
Models Only]
T (1)
(LSM Only)
[In bag labeled "N"]
[Universal washer]
N (8)
(LSM Only)
[Security bracket]
[Mount]
[Security bracket]
[Interface brackets]
(LTM Only)
[Interface brackets]
[Wall bracket caps]
TOOLS REQUIRED FOR INSTALLATION
PARTS
5
LSM/LTM Series Installation Instructions
Center of screen
7-1/2"
Vertical center of mount
(190.5mm)
8
9
5
6
(QB) x 4
7
10
(QC) x 4
(R)
INSTALLATION
The LSM/LTM mounts are designed to be mounted to an 8" concrete, 8"x8"x16" concrete block or 2" x 4" wood studs (16" on center) wall covered by drywall of 5/8" maximum thickness. The LTM has brackets which allow the TV to be tilted. The LSM has static brackets which keep the TV in an upright position.
Locate Mounting Site
WARNING: IMPROPER INSTALLATION CAN LEAD TO
MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT! It is the installers responsibility to make certain the structure to which the mount is being attached is capable of supporting five times the weight of the LTM or LSM and all attached equipment not to exceed 200 lbs (90.7 kg).
NOTE: Proceed to either the Installing to a Wood Stud Wall
section or the Installing to a Concrete Wall section.
Installing to a Wood Stud Wall
1. Determine the center of the TV screen, and where it should be located on the wall.
2. Locate the closest stud to the left and right of the selected location.
NOTE: If the screen area lies over a stud, use that stud and the
stud to either the left or right of it.
5. Using a level, mark the wall on each stud to attach the mount through the upper mounting slots. (See Figure 2)
WARNING: ELECTRICAL SHOCK HAZARD! CUTTING
OR DRILLING INTO ELECTRICAL CORDS OR CABLES CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surface is free of electrical wires and cables before drilling or installing fasteners.
WARNING: EXPLOSION AND FIRE HAZARD! CUTTING
OR DRILLING INTO GAS PLUMBING CAN CAUSE DEATH OR SERIOUS PERSONAL INJURY! ALWAYS make certain area behind mounting surface is free of gas, water, waste, or any other plumbing before cutting, drilling, or installing fasteners.
6. Drill one 7/32" (5.5mm) pilot hole in each stud.
7. Use two 5/16 x 2-1/2" lag bolts (QC) and two 5/16" flat washers (QB) to attach top of mount (R) to wall. (See Figure 2)
3. Line up the notches on mount (A) with center of screen marking to determine vertical center. (See Figure 1)
4. Measure up 7-1/2" (190.5mm) from the center point to mark location of the upper mounting slots.
Figure 2
8. Mark the attachment points for the lower mounting slots, making sure the attachment points are located on the studs. (See Figure 2)
9. Drill 7/32" (5.5mm) pilot holes at markings for lower mounting holes. (See Figure 2)
10. Use two 5/16 x 2-1/2" lag bolts (QC) and two 5/16" flat washers (QB) to attach the mount to the wall through the lower mounting holes. (See Figure 2)
11. Slide rails to approximate center of screen location.
Figure 1
6
Loading...
+ 14 hidden pages