Small Flat Panel
Dual Swing Arm Pole Mount (FPD-110)
The FPD is a sleek design providing a broad range of viewing
for Small Flat Panel Displays.
At only 2.18” deep in the closed position, the mount allows
side-to-side pivot adjustment up to 180 degrees in the closed
and the fully extended position. Displays up to 30” (max. 40
pounds) can be extended to 15.3” and can pivot 360 degrees.
The FPD accommodates all VESA® 75mm/100mm compliant
displays.
BEFORE YOU BEGIN
• Caution: To prevent damage to the FPD, which could affect or void the Factor y war rant y, and to the equip-
ment that will be attached to it, thoroughly study all instructions and illustrations before you begin the
installation. Pay particular attention to the “Important Warnings and Precautions” on Page 1.
• The maximum weight to be installed on the FPD is 40 pounds (18.1 Kg)
• The FPD is designed to be installed using a pole. The pole to which the FPD is anchored must be capable of supporting five times the total weight of the mount and all attached equipment.
• If you have any questions about this installation, contact Chief Manufactu ring at 1-800-582-6480.
WARNING:A WARNI NG alerts you to the possibility of serious injury or death if you do not follow the instructions.
CAUTION:A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corre-
sponding instructions.
• WARNING:Improper installation can result in serious personal injury! Make sure that the structural members can
support a redundant weight factor five times the total weight of the equipment: if not, reinforce the structure before installing the FPD.
• WARNING:Be aware also of the potential for personal injury or damage to the unit if it is not adequately mounted.
• WARNING:The installer is responsible for verifying that the pole to which the FPD is anchored will sa fel y s upport the combined load of al l a t tached components o r o ther equipment.
• WARNING:The weight of the display placed on the FPD must not exceed 40 lbs . (18.1 kg), the maxi mum load capacity of the FPD.
• WARNING:Watch for pinch points. Do not put your fingers between movable parts.
• WARNING:Make sure the mount and brackets are correctly oriented.
• CAUTION: Check the unit for shipping damage before you begin the installation.
TOOLS REQUIRED FOR INSTALLATION
• Phillips Scre wdrive r
NOTE: Other tools may be required depending on the
WARNING: Watch for pinch points. Do not put your fingers
between movable parts.
1.Carefully inspect the FPD for shipping damage. If any damage
is apparent, call your carrier claims agent and do not continue
with the installation until the carrier has reviewed the damage.
NOTE: Read all instructions before starting installation.
2.Lay out components to en sure you have all the required part s
before proceeding (see FPD dra wing on page 2).
FPD INSTALLATION
WARNING: It is t he res ponsibility o f the install er to verify that
the structure to which the FPD is anchored will
safety support five times the combined load of all
attached components and equipment.
Install the FPD as follow s:
1.Determine the exact mounting location prior to installation,
considering the unit’s swing radius.
WARNING: Improper installation can result in serious per-
sonal injury! Make sure that the structural members can support a redundant weight factor five times the total weight of the equipment: if not,
reinforce t h e st ru c t ure b ef o re installi n g the FP D.
2.Using three 1/4-20 button head screws and bracket clamp ,
secur e th e bracket to the pole.
3.Make sure no power is supplied to the display before attempting to mount the display .
WARNING: Watch for pinch points. Do not put your fingers
between movable parts.
VESA Compliant Flush Mounting
CAUTION: If monitor uses a screw size other than M4, DO NOT
use the M4 screws provided. Using the wrong screws
could result in damage to your display.
A. S ta rt t wo M4 X . 7 X 12 mm Phi llips pa n he ad scre ws in the
top mounting holes of your display .
B. Matching th e hole pattern on your display with the hole
pattern on the mount, hang the mount from the two screws
started in Step A.
Figure 1. Secure Bracket To Pole
C. Install two remai ning Phillips pan head screws through the
mount and into the mounting holes of your display.
D. Secure your display to the mount by tightening the four
Phillips pan head screws.
3
Page 5
Installation InstructionsFPD
WARNING: Make sure your cables do not r un through a pinch
point.
E. Connect and secure power/audio/video cables, making
sure to leave sufficie nt slack to allow for movement of the
display.
VESA Compliant Recessed Mounting
A. Place four 1/2” X 3/8” Nylon spacers or four 1/2” X 3/4”
Nylon spacers, as necessary , ove r the mounting holes of
your display (see Figur e 2).
B. Place the mount ove r the Nyl on spacers , mat ching the h ole
pattern on your display (75mm or 100mm) with the hole
pattern on the mount.
C. Using four M4 X .7 X 20mm Phillips pan hea d screws for
1/2” X 3/8” Nylon spacer inst all ation or four M4 X .7 X
30mm Phillips pan hea d screws for the 1/2” X 3/4” Nylon
spacer instal lation, secure the mount to your display.
WARNING: Make sure your cables do not r un through a pinch
point.
Figure 2. Recessed Mounting
D. Connect and secure power/audio/video cables, making
sure to leave sufficie nt slack to allow for movement of the
display.
Non-VESA Compliant Mounts
A. Contact Chief Manufacturing for custom interface brack-
ets.
CABLE MANAGEMENT
WARNING: Make sure your cables do not r un through a pinch
point.
1.Route power/audio/video cables under each arm, allowing sufficient slack in cables for extension and avoiding pinch points
2.Secure cables using cover plates and four screws (see “DRAWINGS” on page 2).
4
Page 6
Installation InstructionsFPD
ADJUSTMENTS
CAUTION: Overtightening adjustment will cause excessive wear.
Rotational Tilt, Pitch, and Roll Adjustment
1.If necessar y , use a Phillip s screwdriver to tighte n or loosen
the Phillips pan head screw (see DRAWINGS).
2.Check for desired tension.
3.Repeat Steps 1 and 2 until desired tension is obtained.
Lateral Tension Adjustment
1. Using a 3/16” hex wrench (provided), slightly tighten or
loosen lateral tension adjustment bolt (see DRAWINGS).
2.Check for desired tension.
3.Repeat Steps 1 and 2 until desired tension is obtained.
Arm Tension Adjustment
1.Using a 3/16” hex wrench (provided), slightly tighten or
loosen arm tension a djustment bol t (see “DRA WINGS ” on
page 2).
2.Check for desired tension.
3.Repeat Steps 1 and 2 until desired tension is obtained.