SAFETY DATA SHEET
Date Printed: 3/16/2018
Page 5 of 14
METAL PRIMER GRAY PART A - GALLON
Chemsol, 12944 Farmington Rd, Livonia, MI 48150
Environmental Precautions:
INFORMATION NOT AVAILABLE.
Methods/Materials for Containment and Cleaning Up:
Contain spillage, and then collect with non-combustible absorbent material,
(e.g. sand earth, diatomaceous earth,
vermiculite) and place in container for disposal according to
local/state/federal regulations.
7. Handling and Storage
Handling:
Keep away from heat, sparks, open flames, hot surfaces. NO SMOKING. Keep
container tightly closed.
Ground/bond container and receiving equipment.
Use explosion-proof electrical/ventilating/lighting/processing equipment.
Use only non-sparking tools.
Take precautionary measures against static discharge.
Wear protective gloves/eye protection/face protection.
Storage:
Prevent unauthorized access.
Store in a well ventilated place.
Keep container tightly closed.
Keep cool.
8. Exposure Controls/Personal Protection
Airborne Exposure Limits:
SEE SECTION 3 FOR THIS INFORMATION
Engineering Controls:
Ventilation: Good general ventilation (typically 10 air changes per hour)
should be used.
Ventilation rates should be matched to conditions.
Ventilation should be explosion proof.
Supplementary local exhaust ventilation, closed systems, or respiratory
protection may be needed in special
circumstances such as poorly ventilated spaces, spray painting, mechanical
generation of dusts, heating, drying, etc.
Personal Protective Equipment
Respiratory Protection:
If engineering controls do not maintain airborne concentrations to an
acceptable level, an approved respirator must be
worn. In the United States of America, if respirators are used, a program
should be instituted to assure compliance