Checkline ESH User Manual

2 YEAR WARRANTY (RESTRICTIONS APPLY)
Imada, Inc. warrants its products to the original purchaser to be free from defects in workmanship and material under normal use and proper maintenance for two years (one year for adapters, attachments, batteries, and cables) from original purchase. This warranty shall not be effective if the product has been subject to overload, shock load, misuse, negligence, accident or repairs attempted by others than Imada, Inc.
During the warranty period, we will, at our option, either repair or replace defective products. Please call our customer service department for a return authorization number and return the defective product to us with freight prepaid.
The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY, and we hereby disclaim all other warranties, express, statutory or implied, applicable to the products and/or software, including but not limited to all implied warranties of merchantability, fitness, non-infringement, results, accuracy, security and freedom from computer virus. In no event shall Imada, Inc. and/or its affiliated companies be liable for any incidental, consequential or punitive damages in connection with the use of its products and/or software.
.
Specifications subject to change without notice.
Model PS Model MF
Model PSH Model ESH
Model FB
INSTRUCTION MANUAL
GENERAL OPERATION
1. Press (or rotate for Model PSH/ESH) Peak Switch OFF.
2. Hand tighten (no tool!) attachment to the measuring shaft.
3. Rotate Tare Ring to read “0” to tare the weight of attachment and
measuring shaft orientation.
4. Begin measuring.
Real Time Mode: the Peak Switch is OFF and the gauge dis­plays force as it changes. During Real Time Mode, you can hold a critical reading by turning the Peak Switch to the ON position. Peak Mode: the Peak Switch is ON and the gauge will retain highest reading taken which will not change until a higher value is measured. Turn the Peak Switch OFF to zero the gauge and turn it ON again to measure Peak values.
DIMENSIONS
MOUNTING
When mounting IMADA mechani­cal gauges to IMADA test stands, hold the gauge firmly and unscrew the 4 screws in back, making sure the case does not separate. (FIG.1)
AP-002 adapter plate mounts IMADA mechanical gauges to IMADA test stands. Align plate and gauge holes and insert the 4 long screws sup­plied to attach gauge. Then utilize the 4 PEM nuts on the adapter plate to mount to IMADA test stands with the mounting bolts supplied.
AP-001 adapter plate mounts IMADA low capacity gauges to most other brands of test stands. Use the 4 screws (supplied) to mount the IMADA gauge to the AP-001 adapter plate. Then utilize the 2 PEM nuts on the AP-001 adapter plate to mount to other brands of test stand.
MOUNTING PS/FB/MF
AP-002 ADAPTER PLATE
LONGER SCREWS
PEM NUT
AP-001 ADAPTER PLATE
LONGER SCREWS
PEM NUT
FIG.1
REMOVE CASE
SCREWS
WITH 4 PEM NUTS
MOUNTING BOLTS
WITH 2 PEM NUTS
MOUNTING BOLTS
Use this bolt only!
Speciications subject to change without notice.
page 2
page 7