Imada, Inc. warrants its products to the original purchaser to be free from defects in
workmanship and material under normal use and proper maintenance for two years (one
year for adapters, attachments and cables) from original purchase. This warranty shall not be
effective if the product has been subject to overload, shock load, misuse, negligence,
accident or repairs attempted by others than Imada, Inc.
During the warranty period, we will, at our option, either repair or replace defective
products. Please call our customer service department for a return authorization number
and return the defective product to us with freight prepaid.
The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY, and we hereby
disclaim all other warranties, express, statutory or implied, applicable to the products and/or
software, including but not limited to all implied warranties of merchantability, fitness, noninfringement, results, accuracy, security and freedom from computer virus. In no event shall
Imada, Inc. and/or its affiliated companies be liable for any incidental, consequential or
punitive damages in connection with the use of its products and/or software.
For safety, and for damage avoidance, be sure to read this manual
thoroughly. The warranty is only valid when the product is used following the instructions provided within this manual.
●
Do not use tester in high temperature, high humidity, or in
damp or wet areas.
●
Recommended operating temperature is between 0-42ºC (32100ºF).
●
Do not apply torque exceeding the rated capacity (35 lbf-in),
regardless of whether the unit is On or Off. Avoid shock load.
Do not use with impact wrenches.
●
When charging the battery, be sure to use the provided AC
adapter/charger exclusively.
●
Do not use lacquer thinner or any solvent to clean the unit.
●
Do not disassemble or modify the unit.
●
Recommended re-calibration cycle is one (1) year.
IMPORTANT! Use the provided CEDAR AC adapter/charger exclusively and plug into the correct AC output. It takes 8 hours to fully
recharge. Do not recharge for more than 12 hours. When fully
charged, disconnect the AC adapter/charger to avoid overcharging.
In order to avoid high heat, explosion or toxic fumes, please note
the following precautions:
1. Be sure to use only the provided AC charger exclusively.
2. Do not plug the charger into unspecified higher voltage.
3. Do not recharge until LOBAT icon appears.
System Reset
When battery power is completely depleted, the tester may not
work even though it has been recharged. In this case, press the
System Reset Button.
RS-232C Serial Output
Output is available in PD,PP and C modes. In PD and PP modes peak
data is output when ZERO is pressed or activated by the AUTO ZERO
function. In C mode, the gauge outputs data continuously.
RS-232C Signal: 8 data, 2 stop,no parity. Baud Rate: 9600 bps.
Peak Data Output Format
[CAN] _ _ _ [SO] [value] _ [SI] [unit] [CR]
[CAN]:ASCII control code 24
_:Space (code 32)
[SO]:ASCII control code 14
[value]:Output data with sign and decimal point. Plus sign
represents for CW torque and minus sign for CCW.
[Value] always occupy six locations and empty
locations will be filled with spaces.
[SI]:ASCII control code 15
[unit]:N*m _ _ _=N.m
kgf*cm = kg.cm
lb*in _ = lb.in
[CR]:ASCII control code 13 (Carriage Return)
Continuous Output Data Format
[CAN] [value] [CR]
page 7page 2
TORQUE MEASUREMENTTORQUE MEASUREMENT
Storing and Recalling Data from Memory
Memory functions work in PP, PD and C modes. Store up to 300
values in memory.Values are simultaneously output as RS-232
even after memory is full.
1. Measure in PP or PD mode, press CLR/PRG to store peak values.
In C mode, the tester outputs data continuously (80 data/sec).
2. To recall a value, press UP or DOWN to select a memory location, the display cycles between location and torque value (i.e.
.0.0.1 for first location).
Note: Selecting an invalid location, defaults to measurement mode.
Clearing Data from Memory
1. Single Clear: When a memory value is displayed, press CLR/PRG,
then “CLR” displays and blinks 3 times. Press CLR/PRG switch
again before “CLR” stops blinking and the memory value is erased.
2. All Clear: Press CLR/PRG and DOWN simultaneously until “ALL”
is displayed.While “ALL” is blinking, press CLR/PRG again. Display
changes to “CLR” and blinks 3 times. Press CLR/PRG again before
“CLR” stops blinking and all memory data is erased.
Downloading Memory Data
1. Press ON/OFF to turn on.
2. Press UP and DOWN switches simultaneously. The display blinks
"FA" twice and then displays numbers with decimal points in
between (.0.0.1 for first memory location).
3. Press UP or DOWN switch to select the desired beginning mem-
ory location and press CLR/PRG to enter. The displays blinks
"LA" for the ending memory location.
4. Press UP switch or DOWN switch to select the desired ending
memory location and press CLR/PRG to enter.
5. Press CLR/PRG switch to download the data.While downloading
the data, the display shows "-P-".
Note: By pressing DOWN switch for more than 1 sec,the download
function can be terminated.
Auto Power Off
To maximize the life of the battery, power automatically shuts off
after 10 minutes of non-use.
6
3
4
2
7
1
ON/OFF Switch Press to turn on, press again to turn off (click
1
5
once, do not hold). After 10 minutes of non-use the unit shuts off.
2
CLR/PRG Switch To reset display to zero and to store data.
LCD Display Displays torque value as well as low battery icon
3
(LOBAT).
AC charger/adapter receptacle If LOBAT icon appears, 8-
4
hour battery recharge required.
System reset button When the battery has been depleted
5
completely and a recharge has been executed, the system may
not yet operate. In this case, press the System Reset Button.
RS-232 output
6
7
CW and CCW Ratchet
page 3page 6
TORQUE MEASUREMENTTORQUE MEASUREMENT
SELECTING RATCHET OPERATION
1. To disable ratcheting, turn the ratchet so the
semi circle is in the center position.
2. Enable CW ratcheting operation by turning the
ratchet one click counter-clockwise from the
center position.
3. Enable CCW ratcheting operation by turning
the ratchet one click clockwise from the center position.
32
1
SELECTING MEASURING MODES
Press ON/OFF to turn on. Hold CLR/PRG for more than 4 seconds.
Display cycles GO, PP, PD or C. Select desired measuring mode,
which becomes the default mode. Press CLR/PRG to display the measuring mode.
GO (Real Time) Display torque transient (no output).
PP (Peak) Capture peak torque (peak data output).
PD (Peak Down) Capture peak down value (peak data output).
C(continuous RS-232 output, 80 data/sec) Display torque tran-
sients.
PROGRAMMING (to exit programming at any time press OFF)
Press ON/OFF to turn on. Press CLR/PRG and UP switches simultaneously and hold for more than 4 seconds.The Green LED lights
and one beep sounds, "HI" is displayed, then the High setpoint value.
The tester is now ready for the following programming steps.
1. High Setpoint (HI)
After "HI" is displayed and then the High setpoint value. Press UP
or DOWN switch to select the High setpoint value i.e. 25.0 for
25.0 lbf-in (for lbf-in gauge), then press CLR/PRG to enter.
2. Low Setpoint (LO)
After High value is entered, "LO" is displayed and then the Low
setpoint value. Press UP or DOWN switch to select the Low setpoint value, then press CLR/PRG to enter.
3. Peak Down Minimum and Trigger Point (PdLO)
After Low value is entered, "PdLO" is displayed and then the PdLO
value. Press UP or DOWN switch to select, then press SET to enter.
PdLO sets a minimum torque value for Peak Down mode. For
example, if "PdLO" value is set at 5.0 lbf-in, only a reading over
5.0 lbf-in will be measured in Peak Down mode.
PdLO also sets the start and stop trigger points for Continuous
data output.When torque reaches the PdLO value, the gauge
starts to output data and stops if torque falls below the value.
4. Batch Counter (CO)
After "PdLO" value is entered, "CO" is displayed and then the
batch count number. Press UP or DOWN switch to select (0 to
99), then press CLR/PRG to enter.
Batch counter retains the number of properly torqued fasteners counted in memory even if the tester is turned OFF. Press
and hold ON/OFF for more than 1 second to reset.
5. Beeper (bp)
After the batch count number is entered, "bp" is displayed and the
display shows "On" for beeper set ON, "Off" for beeper set OFF or
"FF" for no beep unless over high setpoint.Press UP or DOWN
switch to select, then press CLR/PRG to enter.
6. Auto Zero Reset (AC)
After Beeper selection is entered, "AC" is displayed and then Auto
Zero Reset duration value. Press UP or DOWN to select 0.0C -
0.5C - 1.0C - 1.5C - 2.0C - 2.5C - 3.0C, and press CLR/PRG to
enter (0.5C for 0.5 second and 0.0C for MANUAL RESET).
After measuring, Auto Zero automatically resets the tester to "0.0".
7. Time (In)
After Auto Zero Reset is entered "In" is displayed and then the
Time duration.Press UP or DOWN switch to select (0 to 24 seconds), then press CLR/PRG to enter.
After "In" is entered, "S-" is displayed to confirm programming completion and 0.0 is shown.
After setpoints and batch counter are set, the tester counts the number of properly torqued fasteners (between High and Low setpoint)
and beeps three times when completed. If time ("In" value) elapses
before reaching the batch count number, a beep sounds to alert to
possible mis-tightening or stripped thread.
page 5page 4