NOTES
- 16 -
1.0 INTRODUCTION
The DHT-2 Textile Moisture Meter accurately measures the percentage (%) of humidity contained in textiles. It can be equipped with different transducers (called “electrodes”), according to the type of material being tested.
1.1 Principle of Operation
When the DHT-2 probe is placed in contact with a textile sample, it measures the electrical conductivity of the material, which varies based upon the type of material under test, and the amount of moisture present.
Next, using one of its 17 built-in, user selectable material measurement scales, the DHT-2 automatically converts the conductivity reading into an accurate measurement of humidity percentage contained in the textile. This measurement appears on the LED display.
If material under test is not included in the DHT-2’s built-in measurment scales (see specifications,section 5.1) , the absolute value of electrical conductivity (range 0–100) can be converted to a percentage of humity reading using the convervison tables provided in the Appendix
.
2.0 OVERVIEW
2.1 Gauge
- 2 -
2.2 Complete Kit
The DHT-2 is shipped with everything you need to begin taking measuremnts, including:
• Gauge • 9 Volt Battery
• Electrode Holder • Operating Manual
• Connecton Cable • Leather Carrying Case
Electrode Holder
Removable Plastic Ring
Connection Cable
Gauge
Power On/Off
Selects Measurement Scale
Electrode
- 15 -
7.0 WARRANTY
ELECTROMATIC Equipment Co., Inc. (ELECTROMATIC) warrants to the original purchaser that this product is of merchantable quality and confirms in kind and quality with the descriptions and specifications thereof. Product failure or malfunction arising out of any defect in workmanship or material in the product existing at the time of delivery thereof which manifests itself within one year from the sale of such product, shall be remedied by repair or replacement of such product, at ELECTROMATIC’s option, except where unauthorized repair, disassembly, tampering, abuse or misapplication has taken place, as determined by ELECTROMATIC. All returns for warranty or non-warranty repairs and/or replacement must be authorized by ELECTROMATIC, in advance, with all repacking and shipping expenses to the address below to be borne by the purchaser.
THE FOREGOING WARRANTY IS IN LIEU OF ALL OTHER WAR­RANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE WARRANTY OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE OR APPLICATION. ELECTROMATIC SHALL NOT BE RESPONSIBLE NOR LIABLE FOR ANY CONSEQUENTIAL DAMAGE, OF ANY KIND OR NATURE, RESULTING FROM THE USE OF SUPPLIED EQUIPMENT, WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE, UPON OR AFTER REPLACEMENT OR REPAIR, AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFAC­TURER’S OR SUPPLIER’S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE.
Some State jurisdictions or States do not allow the exclusion or limitation of inci­dental or consequential damages, so the above limitation may not apply to you. The duration of any implied warranty, including, without limitation, fitness for any particular purpose and merchantability with respect to this product, is limited to the duration of the foregoing warranty. Some states do not allow limitations on how long an implied warranty lasts but, not withstanding, this warranty, in the absence of such limitations, shall extend for one year from the date of invoice.
ELECTROMATIC Equipment Co., Inc. 600 Oakland Ave. Cedarhurst, NY 11516—USA Tel: 1-800-645-4330/ Tel: 516-295-4300/ Fax: 516-295-4399
Every precaution has been taken in the preparation of this manual. Electromatic Equipment Co., Inc.,
assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting
from the use of information contained herein. Any brand or product names mentioned herein are used for
identification purposes only, and are trademarks or registered trademarks of their respective holders.
3.0 MEASURING PROCEDURE
3.1 Preparation
1. Connect the gauge to the electrodes holder using the supplied Connection Cable.
2. Unscrew the upper plastic ring of the electrode holder, insert the desired electrode, replace the plastic ring.
3.2 Taking A Measurement
1. Press the Power On/Off key.
2. Select one of the built-in measurement scales by
pressing the key until the desired material name appears on the display
(see photo). For
other materials, select the 0-100 scale.
3. Insert the prongs of the electrode
completely into
the sample
.
4. If you are using one of the built-in measurment scales, the percentage of humidity appears on the LED display. For other materials use the conversion scales (see Appendix) to convert the 0-100 reading into a humidity percentage.
- 3 -
- 14 -
<
Loading...