The Vesuvio II Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu
options, and DMX values. Download the User Manual from www.chauvetprofessional.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
Safety Notes
Depending on the amount of fog generated, all fog machines may set off smoke detectors.
•Drain the tank before transporting the product.
•This product is not intended for permanent installation.
•This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose this product to rain or
moisture.
•Do not operate this product if the housing, fluid tank, or cables appear damaged.
•In the event of a serious operating problem, stop using immediately.
•DO NOT open this product. It contains no user-serviceable parts.
•Do not use for space heating purposes.
•Never disconnect this product from power by pulling on the cord.
•Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
•USE a safety cable when mounting this product overhead.
•Do not touch the output nozzle on this product. It is very hot during operation and it may remain hot for several
hours after turning the product off.
•Do not leave any flammable material within 50 cm of this product while operating or connected to power.
•Only use Chauvet (QDF) fog fluid.
•Do not add anything to the fog liquid.
•Do not drink the fog liquid.
•Do not allow the fog liquid to touch your skin or eyes.
•Do not connect this product to a dimmer or rheostat.
•Only connect this product to a grounded and protected circuit.
•Only use the handles to carry this product.
•The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
•To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
•CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
Contact
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux contact your distributor to request support or return a
product. Visit www.chauvetprofessional.com for contact information.
What is Included
•Vesuvio II
•Omega Brackets (x2)
•Seetronic Powerkon IP65 power cord
•Warranty Card
•Quick Reference Guide
EN
Vesuvio II QRG Rev. 2
1
QUICK REFERENCE GUIDE
EN
AC Power
This product has a fixed voltage power supply and it can work with an input voltage of either 120 VAC, 60 Hz or 230 VAC
50 Hz, depending on the specific model.
AC Plug
ConnectionWire (U.S.)Wire (Europe)Screw Color
AC LiveBlackBrownYellow/Brass
AC NeutralWhiteBlueSilver
AC GroundGreen/YellowGreen/YellowGreen
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
!
Resetting the Breaker
This product is equipped with a resettable circuit breaker. If the breaker trips, all sections of this product will lose power.
1.Remove the power cord from main power.
2.Allow unit to cool for 15 minutes.
3.After 15 minutes, you may attempt to reset the breaker by pressing the button with your finger.
4.Plug the product’s power cord into the power outlet and continue using as recommended.
DMX Linking
The Vesuvio II will work with a DMX controller using a 3- or 5-pin DMX data connection for its 15-channel DMX
personality. A DMX Primer is available from www.chauvetprofessional.com.
DMX Connection
The Vesuvio II uses a 3- or 5-pin DMX data connection for its 15-channel DMX personality. See the User Manual for
information about connecting and configuring the product for DMX operation.
Preparing for Operation
To prepare the Vesuvio II for operation:
1.Pull out the fluid tank and remove the cap.
2.Verify that the two plastic hoses attached to the inside of the cap are in place and in good condition.
3.Pour Chauvet (QDF) fog fluid inside the tank, and re-cap.
4.Make sure that the plastic hose that goes from the cap to the fogger is not bent.
5.Reinsert the tank.
6.Plug in power and wait approximately 7 minutes for warm-up to complete.
disconnect the product from power via breaker or by unplugging it.
!
When storing the product, ALWAYS be sure to store the fluid tank with the cap up as seen on the
Product Mounting Diagram before installing the front cover to avoid tube damage that may cause
leakage.
Only use Chauvet approved (QDF) fog fluid. Otherwise, you might not have satisfactory results.
In addition, unapproved fluid can damage the Vesuvio II or cause harm to humans or animals.
2
Vesuvio II QRG Rev. 2
QUICK REFERENCE GUIDE
EN
Mounting
Before mounting this product, read the Safety Notes. Use at least one mounting point per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For our CHAUVET Professional line of mounting
clamps, go to http://trusst.com/products.
Mounting Diagram
Downwards Fog Output
Fluid Tank
Plate
Screws (x4)
Omega Bracket Placement Options
Mounting Clamp (x2)
Omega Bracket
(x2)
Surface Mounting
Fluid Tank Reversed
Downwards Fog Output
Horizontal Fog Output
Safety Cables
Rubber Feet (x4) for
floor mounting
Vesuvio II QRG Rev. 2
Rubber Feet (x4) for
floor mounting
(horizontal fog
output)
Omega Bracket (x2)
Mounting Clamp (x2)
3
QUICK REFERENCE GUIDE
Control Panel Description
Button/KnobFunction
<FUNCTION>Enters the programming mode
<UP>Navigates upwards through the menu list and increases the numeric value when in a function
<DOWN>Navigates downwards through the menu list and decreases the numeric value when in a function
<TIMER>Starts the timer controlled operation
<VOLUME>Controls the fogvolume,1-100%
<MANUAL>Manual fog output
Menu Map
Main LevelProgramming LevelsDescription
Interval Set10-200 SecondsSets the interval between fog output
Duration Set1-10 SecondsSets the duration of the fog output
10White
11Zone 1 red, zone 2 green
12Zone 1 red, zone 2 blue
13Zone 1 green, zone 2 red
14Zone 1 green, zone 2 blue
15Zone 1 blue, zone 2 red
16Zone 1 blue, zone 2 green
17Zone 1 magenta, zone 2 amber
18Zone 1 magenta, zone 2 blue
19Zone 1 amber, zone 2 magenta
20Zone 1 blue, zone 2 hot pink
21Random color output
EN
Vesuvio II QRG Rev. 2
4
EN
Color Zones
QUICK REFERENCE GUIDE
Color Zone 1
Color Zone 2
5
Vesuvio II QRG Rev. 2
QUICK REFERENCE GUIDE
DMX Values
15 CH
ChannelFunctionValuePercent/Setting
000
1Fog
2Red zone 1
3Green zone 1
4Blue zone 1
5Amber zone 1
6UV zone 1
7Red zone 2
8Green zone 2
9Blue zone 2
10Amber zone 2
11UV zone 2
12Color Mixing
13Auto Speed
14Strobe
15Dimmer
009No function
010 255Fog on
000 014No function
2550-100%
015
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 014No function
015 2550-100%
000 009No function
010 255Color Mixing
000 009No function
010 255Speed, slow to fast
000 009No function
010 255Speed, slow to fast
000 014No function
015 2550-100%
EN
Vesuvio II QRG Rev. 2
6
GUÍA DE REFERENCIA RÁPIDA
ES
Acerca de Esta Guía
La Guía de Referencia Rápida (GRR) del Vesuvio II contiene información básica sobre el producto, como montaje,
opciones de menú y valores DMX. Descargue el manual de usuario de
más detallada.
Exención de Responsabilidad
La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.
Notas de Seguridad
Estas notas de seguridad incluyen información importante sobre el montaje, uso y mantenimiento.
•Dependiendo de la cantidad de niebla generada, todas las máquinas de niebla pueden disparar los detectores de
humo.
•Vacíe el depósito antes de transportar el producto.
•Este producto no está concebido para una instalación permanente.
•Este producto es para uso en interiores solamente! (IP20) Para evitar riesgos de incendio o descarga, no exponga
este producto a la lluvia o la humedad.
•No ponga en funcionamiento este producto si sospecha que la carcasa, el depósito de líquido o los cables están
dañados.
•En caso de un problema grave de funcionamiento, deje de usarlo inmediatamente.
•NO abra este producto. No contiene piezas reparables por el usuario.
•No utilizar para calentar espacios.
•Nunca desconecte este producto de la alimentación tirando del cable.
•Monte este producto en una ubicación con ventilación adecuada,al menos a 20 in (50 cm) de superficies
adyacentes.
•USE un cable de seguridad cuando monte este producto en lo alto.
•NO toque la boquilla de salida de este producto. Se calienta mucho durante el funcionamiento, y puede
permanecer caliente durante varias horas después de apagar el producto.
•No deje ningún material inflamable a menos de 50 cm de este producto mientras esté funcionando o conectado
a la alimentación.
•Utilice solamente fluido de niebla Chauvet (QDF).
•No añada nada al líquido de niebla.
•No beba el líquido de niebla.
•No permita que el líquido de niebla entre en contacto con la piel o los ojos.
•No conecte este producto a un atenuador o reostato.
•Conecte este producto solo a un circuito con toma de tierra y protegido.
•Use solamente las asas para mover este producto
•La temperatura ambiente máxima es de 113 °F (45 °C). No haga funcionar este producto a temperaturas más
altas.
•Para evitar un desgaste innecesario y alargar su vida útil, desconecte completamente el producto de la
alimentación mediante el interruptor o desenchufándolo durante periodos en que no se use.
•CUIDADO: Cuando traslade el producto desde ambientes de temperatura extrema (p. ej. desde un camión frío a
una sala de fiestas húmeda y caliente) se puede formar condensación en la electrónica interna del producto. Para
evitar que se produzca un fallo, deje que el producto se aclimate totalmente al entorno antes de conectar la
alimentación.
Contacto
Fuera de EE.UU, Reino Unido, Irlanda, México o Benelux, póngase en contacto con su distribuidor para solicitar
asistencia o devolver el producto. Visite www.chauvetprofessional.com para información de contacto.
Qué va Incluido
•Vesuvio II
•Soporte Omega (x2)
•Seetronic Powerkon IP65 cable de alimentación
•Tarjeta de Garantía
•Guía de Referencia Rápida
www.chauvetprofessional.com para información
7
Vesuvio II GRR Rev. 2
Loading...