Synapse 4 QRG EN
The Synapse 4 Quick Reference Guide (QRG) has basic product information such
as connection, mounting, menu options, and DMX values. Download the User
Disclaimer
The information and specifications contained in this QRG are subject to change
without notice.
Safety Notes
• DO NOT open this product. It contains no user-servic eable parts.
product at higher temperatures.
Contact
Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux, contact your
distributor to request support or return a product. From inside the U.S., UK, Ireland,
Mexico, or Benelux, use the information in Contact Us at the end of this QRG.
What Is
Included
AC Power
This product has an auto-ranging power supply that can work with an input voltage
range of 100–240 VAC, 50/60 Hz.
AC Plug
This product is equipped with resettable circuit breakers. Each secti on has its own
4. Connect the product to power and continue using as recommended.
Disconnect this product from the power outlet before resetting the breaker. If
Guide
Manual from www.chauvetprofessional.com for more details.
• Mount this product in a location with adequate ventilation, at least
20 in (50 cm) from adjac ent surfaces.
• DO NOT leave any flammable material within 50 cm of this product while
operating or connected to power.
• CAUTION: When transferring product from extreme temperature
environments, (e.g. cold truck to warm humid ballroom) condensation may
form on the internal electronics of the product. To avoid causing a failure,
allow product to fully acclimate to the surrounding environment before
connecting it to power.
• USE a safety cable when mounting this product overhead.
• DO NOT operate this product outdoors or in any location where dust,
excessive heat, water, or humidity may affect it. (IP20)
• DO NOT operate this product if the housing or cables app ear damaged.
• DO NOT connect this product to a dimmer or rheostat.
• ONLY connect th is product to a grounded an d protected circuit.
• In the event of a seriou s operating problem, stop using immediately.
• The maximum ambient temperature is 113 °F (45 °C). Do not operate this
• Neutrik p o werCON power cord
• Quick Reference Guide
Breaker
20 A circuit breaker that runs through the 20 A main breaker. If the main
trips, all sections of this product will lose power.
1. Disconnect the product from power.
2. Allow th e product to cool for 15 minutes.
3. After 15 minutes, try to reset the breaker by pressing the button until it latches
in the operation positio n.
the breaker does not reset (the breaker button will not remain inserted
contact Chauvet immediately. This indicates a possible internal malfuncti on.
2
Synapse 4 QRG EN
DMX Linking
The Synapse 4 will work with a DMX controller using a 5-pin DMX serial
connection. A DMX Primer is available from www.chauvetprofessional.com.
DMX Connection
The Synapse 4 uses a 5-pin DMX data connection for its DMX personalities: 1CH
the product for DMX operation.
Mounting
Before mounting this product, read the Safety Notes. Use at least one mounting
http://trusst.com/products/.
Exits from the current menu or function
Enables the currently displayed menu or sets the currently
selected value into the selected function
Navigates upwards through the menu list or increases the
numeric value when in a function
Navigates downwards through the menu list or decreases
the numeric value when in a function
Secure the safety cable using
the passageway on the back
of the product.
2 Keyhole cutouts on each
side on the bottom of th e
2 removable rack mount tabs
on each side of the product.
and 4CH. See the User M anual for informa tion about connecting and configuring
point per product. Make su re th e moun tin g clamps, screws, and
product is mounted to are capable of supporting the weight of the product.
CHAUVET Professional line of mounting clamps, g
Product
Mounting
Diagram
product for wal l mo u nti ng
Description
<ENTER>
<UP>
<DOWN>
3
Synapse 4 QRG EN
Turns power to the power outputs on
the back of the product off
Turns power to the power outputs on
the back of the product on
Turns power on/off thru DMX control
Turns power on/off as a DMX signal is
detected
Sets product to follow the assigned
schedule
Menu Map
Turn Off
Turn On
Power Setup
On If DMX On
Scheduler
All Power
Ports
Power
Port 1
Power
Output Delay
Unit
Power
Port
Port 2
Power
Port 3
0-120 S
Sets a time delay to the power output
Date & Time
12/12/2014 00:00
Power
Port 4
12/12/2014 00:00
4
Sets the current date and time
Synapse 4 QRG EN
Sets the t ime the event will run
Menu Map (Cont.)
Scheduler
Event
1–8
On/Off
Scheduler
On/Off
Power
Output
All
Power
Ports
Power
Port 1
Power
Port 2
Power
Port 3
Power
Port 4
Ports
Ports
Port 1
Port 1
Port 2
Port 2
Port 3
Port 3
Port 4
Port 4
0-120 S
Activates the scheduler for the set
event
Sets which ports will turn on/off during
the event
Week Setup
Sets the days the event will run
5
Synapse 4 QRG EN
Display backlight always on
Turns off display backlight after 10 sec
of inactivity
Turns off display backlight after 20 sec
of inactivity
Turns off display backlight after 30 sec
of inactivity
Shows total product hours
Shows installed software version
Selects DMX address (highest channel
restricted to personality chosen)
1-channel: power port control
4-channel: individual power port
control
Menu Map (Cont.)
10S
Back Light
Information
DMX Address 1–512
20S
30S
DMX Channels
DMX Values
Power Output
1
On/Off
Power Output 1
1
On/Off
Power Output 2
2
On/Off
Power Output 3
3
On/Off
Power Output 4
5
On/Off
4CH
6
Synapse 4 GRR ES
La Guía de Referencia Rápida (GRR) del Synapse 4 contiene información
básica sobre el produ cto, c omo conexión , montaj e, opci ones de menú y val ores
para
información más detal l ad a.
Exención de
Responsabilidad
La información y especificaciones contenidas en esta GRR están sujetas a
• NO abra este producto. No c on t iene piezas reparables por el usuario.
este producto a temperaturas más altas.
Contacto
Fuera de EE.UU., Reino Unido, Irlanda, México o Benelux póngase en
contacto con su distribuidor para solicitar asistencia o devolver el producto.
Desde dentro de EE.UU., Reino Unido, Irlanda, México o Benelux, utilice la
información de Contact Us del final de esta GRR.
Qué va Incluido
Guía
DMX. Descargue el Manual de Usuario de www.chauvetprofessional.com
cambio sin previo aviso.
Seguridad
• Monte este product o en una ubicación con ventilación adecuada, al menos
a 20'' (50 c m) de superficies adyacentes.
• NO deje ningún material inflamable a menos de 50 cm de este producto
mientras esté funcionando o conectado a la alimentación.
• Cuidado: cuando transfiera el producto desde ambientes con temperatura
extrema (p. ej., del remolque frío de un camión a una sala de baile con
calor y humedad), puede formarse condensación en la electrónica interna
del producto. Para evitar que se produzca una avería, d eje que el produc to
se aclimat e completament e al ambiente antes de conectar la alimentación.
• USE un cable d e seguridad cuando monte este producto en lo alto.
• NO ponga en funcionamiento este producto en el exterior o en cualquier
ubicación en la que el polvo, calor excesi vo, agua o humedad puedan
afectarlo. (IP20)
• NO ponga en funcionamiento este producto si sospecha que la carcasa,
lentes o cables están dañados.
• NO conecte este produ cto a un atenuador o reostato.
• Conecte este producto SOLO a un circuito con toma de tierra y protegido.
• En caso de un problema grave de funcionamiento, deje de usarlo
inmediatamente.
• La temperatura ambiente máxima es de 113 °F (4 5 °C). No haga funcionar
• Cable de alimentación
• Guía de Refer encia Rápida
8
Synapse 4 GRR ES
Corriente
alterna
Este producto tiene una fuente de alimentación con detección automática que
Enchufe CA
Rearmar el
disyuntor
Este producto va equipado con disyuntores rearmables. Cada sección tiene su
propio disyuntor de 20 A, que funciona a través del disyuntor principal de 20 A. Si
el disyuntor principal salta, todos los circuitos de este producto se quedarán sin
Desconecte este producto del enchufe de alimentación antes de rearmar el
disyuntor. Si el disyuntor no se rear ma (el botón del disyuntor no se queda
Eso indica
una posible avería interna.
Enlace DMX
El Synapse 4 func ionará con un c ontrolador DMX usand o una conexión de datos
DMX de 5 pines. Hay un Manual DMX disponible en
www.chauvetprofessional.com
Conexión DMX
El Synapse 4 usa una conexión de datos DMX de 5 pines para sus personalidades
. Consulte el Manual de Usuario para más información sobre
cómo conectar y configurar el producto para el funci onamiento DMX.
puede funcionar con un rango de tensión de entrada de 100–240 VCA, 50/60 Hz.
alimentación.
1. Desconect e el producto de l a alimentación.
2. Deje q ue el producto se enfríe durante 15 minutos.
3. Después de 15 minutos, intente rearmar el disyuntor pulsando el botón del
disyuntor hasta qu e s e bloquee en la posición de funci onamiento.
4. Conecte el producto a la alimentación y continúe usándolo según se
hacia adentro), póngase en contacto con Chauve t inmediatamente.
DMX: 1CH y 4CH
9