Chauvet Pro OVATIONED200WW Quick Start Guide

Quick Reference Guide
*Lens tubes sold separately
English EN Español ES Français FR Nederlands NL
QUICK REFERENCE GUIDE

About This Guide

The Ovation ED-200WW Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu options, and DMX values. Download the User Manual from www.chauvetprofessional.com

Disclaimer

The information and specifications contained in this QRG are subject to change without notice.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance.
DO NOT open this product. It contains no user-serviceable parts.
DO NOT look at the light source when the product is on.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
CAUTION: This product’s housing may be hot when lights are operating.
Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect it. (IP20)
DO NOT operate this product if the housing, lenses, or cables appear damaged.
ONLY connect this product to a grounded and protected circuit.
ONLY use the hanging/mounting bracket or the handles to carry this product.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.

Contact

Outside the U.S., United Kingdom, Ireland, Mexico, or Benelux contact your distributor to request support or return a product. Visit www.chauvetprofessional.com for contact information.

What is Included

Ovation ED-200WW
Neutrik® powerCON® power cord
Warranty Card
Quick Reference Guide

AC Power

This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.

Power Linking

In 750 W mode, you can link up to 6 Ovation ED-200WW products at 120 V, or 12 products at 230 V. In 575 W mode, you can link up to 8 products at 120 V, or 15 products at 230 V. Never exceed this number. Power linking cords can be purchased separately.

AC Plug

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass AC Neutral White Blue Silver AC Ground Green/Yellow Green/Yellow Green
for more details.
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Replacing the Fuse

1. Disconnect this product from power.
2. Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
1
Ovation ED-200WW QRG Rev. 1
QUICK REFERENCE GUIDE
Safety Cable
Mounting Clamp
Secure the safety
cable using the passageway on
the back of the
product

DMX Linking

The Ovation ED-200WW will work with a DMX controller using a 3- or 5-pin DMX data connection. A DMX Primer is available from www.chauvetprofessional.com

DMX Connection

The Ovation ED-200WW uses a 3- or 5-pin DMX data connection for its DMX persona lities: UNO, DOS, and STD.P. See the User Manual for information about connecting and configuring the product for DMX operation.

Master/Slave Connection

The Ovation ED-200WW uses the DMX data connection for its Master/Slave mode. See the User Manual for infor mation about connect and configure the product for master/slave operation.

RDM (Remote Device Management)

Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally along existing DMX cabling. The Ovation ED-200WW supports RDM protocol that allows feedback to monitor temperature and changes to ADDRESS, PERSONALITY, DIMMER, and PWM menu options. Download the User Manual from www.chauvetprofessional.com

Dimmer Control

The Ovation ED-200WW may be plugged into and controlled using a regular dimmer. In this mode, the product reacts exactly like an incandescent product. See the User Manual to configure Dimmer Control operation.

Mounting

Before mounting this product, read the Safety Notes. Use at least one mounting point per product. Make sure the mounting clamps are capable of supporting the weight of the product. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products

Mounting Diagram

.
for more details.
.

Lens Tubes

The following lens tubes are available for purchase:
19°, 26°, 36°, and 50° w/Gel frame (6.25 in/159 mm accessories)
15°–30° and 25°–50° Zoom Gel frame (7.5 in/191 mm accessories)

Passcode

After being prompted, enter the following passcode: <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>. This passcode cannot be changed and must be used whenever prompted.
Ovation ED-200WW QRG Rev. 1
2
QUICK REFERENCE GUIDE

Control Panel Description

Button Function
<MENU> Exits from the current menu or function
<ENTER> Enables the currently displayed menu or sets the currently selected value into the selected function
<UP> Navigates upwards through the menu list and increases the numeric value when in a function
<DOWN> Navigates downwards through the menu list and decreases the numeric value when in a function

Menu Map

Main Level Programming Levels Description
STATIC DIMMER 0–100 Manual control of output
DMX512 Sets the mode to DMX control
SLAVE Sets the mode to master/slave
RUNMODE
POWER MODE
ADDRESS 001–512 Sets the starting address
KEY
DIMMER
CURVE
PERFORM
SETTING
INFO
SLOCK
PERSONALITY
DMX ERROR
RESET Pass code: Resets product to factory defaults
MODE
SETTING
PWM
VERSION V_ _ Displays product firmware version
RDM
DMMR
SENS Automatically chooses between dimmer and DMX 575W Matches output to 575 W incandescent fixture 750W Matches output to 750 W incandescent fixture
ON
OFF OFF Linear dimmer
DIM1 DIM2 DIM3 DIM4
OFF No dimmer curve
CURVE1 CURVE2 CURVE3
LIVE
STUDIO Maintains LED cooling by limiting power level
ON
OFF
UNO
STD.P
SAVE Continues last command upon loss of DMX signal
BLACK Blacks out product upon loss of DMX signal
SELF No DMX output from product in standalone
MAST Sends DMX output in standalone mode
600Hz 1200Hz 2000Hz 2400Hz 6000Hz
18000Hz 25000Hz
UID _ _ _ _ _ Displays product UID for RDM
LABEL _ _ _ _ _ Displays product label for RDM
Sets the mode to dimmer control, which turns off data input
Sets the key lock (passcode mode)
Slow (DIM4) to fast (DIM1) dimmer speeds. For best performance while using on a dimmer, set this to DIM4.
Large (CURVE3) to small (CURVE1) dimmer curves. For best performance while using on a dimmer, set this to CURVE3.
Balances LED cooling using fans and output power level
SETTING menu level access lock
Selects DMX personalityDOS
Sets the Pulse Width Modulation frequency
3
Ovation ED-200WW QRG Rev. 1
QUICK REFERENCE GUIDE

DMX Values

STD.P

Channel Function Value Percent/Setting
1 Dimmer 000 2 Dimmer Fine 000
3Strobe
DOS
Channel Function Value Percent/Setting
1 Dimmer 000 2 Dimmer Fine 000
UNO
Channel Function Value Percent/Setting
1 Dimmer 000
255 0–100% 255 0–100% 009 Open
000 010
099 Strobe, slow to fast
100
109 Open
110
179 Lightning effect, slow to fast
180
189 Open
190
255 Random strobe, slow to fast
255 0–100% 255 0–100%
255 0–100%
Ovation ED-200WW QRG Rev. 1
4
GUÍA DE REFERENCIA RÁPIDA
ES

Acerca de Esta Guía

La Guía de Referencia Rápida (GRR) del Ovation ED-200WW contiene información básica sobre el producto, como montaje, opciones de menú y valores DMX. Descargue el manual de usuar io de www.chauvetprofessional.com información más detallada.

Exención de Responsabilidad

La información y especificaciones contenidas en esta GRR están sujetas a cambio sin previo aviso.

Notas de Seguridad

Estas notas de seguridad incluyen informació n imp or tant e so br e el mo n taje , us o y ma nte n imie n to .
NO abra este producto. No contiene piezas reparables por el usuario.
NO mire a la fuente de luz cuando el producto esté encendido.
Para evitar un desgaste innecesario y alargar su vida útil, desconecte complemente el producto de la alimentación, mediante el interruptor o desenchufándolo, durante los periodos en los que no se use .
Cuidado: cuando transfiera el producto desde ambientes con tem peratura extrema (p. ej., del remolque frío de un camión a una sala de baile con calor y humedad), puede formarse condensa ción en la electrónica interna del producto. Para evitar que se produzca una avería, deje que el producto se aclima t e completame nte al a mbiente antes de conectar la alimentación.
¡CUIDADO! La carcasa de este producto está caliente cuando las luces están en funcionamiento.
Monte este producto en una ubicación con ventilación adecuada, al menos a 20'' (50 cm) de superficies adyacentes.
NO deje ningún material inflamable a menos de 50 cm de este pro ducto mientras esté fun cionando o conectado a la alimentación.
USE un cable de seguridad cuando monte este producto en lo alto.
NO ponga en funcionamiento este producto en el exterior o en cualquier ubicación en la que el polvo, calor excesivo, agua o humedad puedan afectarlo. (IP20)
NO ponga en funcionamiento este producto si sospecha que la carcasa, lentes o cables están dañados.
Conecte este producto SOLO a un circuito con toma de tierra y protegido.
Use SOLAMENTE los soportes de colgar/montar o las asas para mover este producto.
En caso de un problema grave de funcionamiento, deje de usarlo inmediatamente.
La máxima temperatura ambiente es de 113 °F (45 °C). No haga funcionar este producto a temperaturas más altas.

Contacto

Fuera de EE.UU, Reino Unido, Irlanda, México o Benelux, póngase en contacto con su distribuidor para solicitar asistencia o devolver el producto. Visite www.chauvetprofessional.com para información de contacto.

Qué va Incluido

Ovation ED-200WW
Cable de Alimentación Neutrik® powerCON®
Tarjeta de Garantía
Guía de Referencia Rápida

Corriente Alterna

Este producto tiene una fuente de alimentación con detección automática que puede funcionar con un rango de tensión de entrada de 100–240 VCA, 50/60 Hz.

Alimentación en Cadena

En modo 750 W, puede enlazar hasta 6 productos Ovation ED-200WW a 120 V o 12 productos a 230 V. En modo 575 W, puede enlazar hasta 8 productos a 120 V o 15 productos a 230 V. Los cables de alimentación en cadena se pueden adquirir por separado.

Enchufe CA

Conexión Cable (EE.UU) Cable (Europa) Color del Tornillo
CA Cargado Negro Marrón Amarillo/Bronce
CA Neutro Blanco Azul Plata
CA Tierra Verde/Amarillo Verde/Amarillo Verde
para
Para evitar un desgaste innecesario y alargar su vida útil, desconecte complemente el producto de la alimentación, mediante el interruptor o desenchufándolo, durante los periodos en los que no se use.

Sustitución del Fusible

1. Desconecte el producto de la toma de corriente.
2. Con un destornillador de estrella Nº2 desatornille la tapa del portafusibles.
3. Quite el fusible fundido del portafusibles y sustitúyalo con otro del mismo tipo y categoría.
4. Vuelva a atornillar la tapa del portafusibles en su sitio y conecte de nuevo la alimentación.
5
Ovation ED-200WW GRR Rev. 1
Loading...
+ 14 hidden pages