Chauvet DJ Intimidator Spot 355Z IRC User manual

User Manual
TABLE OF CONTENTS
1. Before You Begin .............................................................................. 4
Claims ........................................................................................................................ 4
2. Introduction ....................................................................................... 6
3. Setup .................................................................................................. 8
Fuse Replacement ..................................................................................................... 8
Power Linking............................................................................................................. 9
Orientation ............................................................................................................... 10
Rigging ..................................................................................................................... 10
4. Operation ..........................................................................................11
Menu Map ................................................................................................................ 11
Starting Address ....................................................................................................... 12
DMX Personalities .................................................................................................... 12
DMX Assignments ................................................................................13
Sound-Active Mode .................................................................................................. 18
Sound Sensitivity ...................................................................................................... 18
Automatic Mode ....................................................................................................... 18
Manual Pan/Tilt Operation ....................................................................................... 18
Pan/Tilt Angle Range ............................................................................................... 19
Display ..................................................................................................................... 19
Master/Slave Mode .................................................................................................. 20
IR Mode ................................................................................................................... 21
IRC-6 Operation ....................................................................................................... 21
5. Technical Information ......................................................................24
Returns ..................................................................................................25
Page 2 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
6. Technical Specifications ..................................................................27
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 3 of 27
What Is

Unpacking
Instructions

included accessories) appear damaged from
damage not related to shipping,
Text
1–512
A range of values
50/60
A set of values of which only one can be chosen
Settings
A menu option not to be modified
Menu > Settings
A sequence of menu options to be followed
<ENTER>
A key to be pressed on the product’s control panel
ON
A value to be entered or selected

Symbols

Critical installation, configuration, or operation information. Not damage to the product, or cause harm to the operator.
Document
The information and specifications contained in this document are subject to change
assumes no responsibility or liability for any errors or omissions
reserves the right to update the existing
Author
Date
Editor
Date

1. BEFORE YOU BEGIN

Included

Claims

Conventions
Intimidator™ Spot 355Z IRC
Hanging Bracket with Mounting
Hardware
Power Cord
Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
If the box or the contents (the product and shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, or concealed damage, file a claim with Chauvet within 7 days of delivery.
Convention Meaning
Symbol Meaning
Wedding-Ready Gobo Pack
Warranty Card
Quick Reference Guide
following these instructions may make the product not work, cause
Important installation or configuration information. The product may not function correctly if this information is not used.
Useful information.
Information
without notice. Chauvet that may appear in this manual. Chauvet document or to create a new document to correct any errors or omissions.
You can download the latest version of this document from www.chauvetlighting.com.
© Copyright 2015 Chauvet. All rights reserved.
Electronically published by Chauvet in the United States of America.
M. Trouard 12/15/2014 A. Leon 01/14/15
Page 4 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
Product at a
x
P
x
P
P
P
P
x
P

Safety Notes

important information about the mounting, usage, and maintenance
Do not touch the product’s housing when operating because it may be very hot.
completely disconnect the product from power via breaker or by unplugging it.
Glance
Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave
These notes include of this product; read before using the product.
This product is not intended for permanent installation.
Always connect the product to a grounded circuit to avoid the risk of electrocution.
Always disconnect the product from power before cleaning or replacing the fuse.
Avoid direct eye exposure to the light source while the product is on.
Make sure the power cord is not crimped or damaged.
Never disconnect the product from power by pulling or tugging on the cord.
If mounting the product overhead, always secure to a fastening device using a
safety cable.
Make sure there are no flammable materials close to the product when operating.
Always make sure that the voltage of the outlet to which y ou are conne cti ng the
product is within the range stated on the decal or rear panel of the product.
The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose the product to rain or moisture.
Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
Be sure that no ventilation slots on the product’s housing are blocked.
Never connect the product to a dimmer.
Make sure to replace the fuse with another of the same type and rating.
Never carry the product from the power cord or any moving part. Always use the
hanging/mounting bracket or the handles.
The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at higher temperatures.
In the event of a serious operating problem, stop using the product immediately.
Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance center.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
Auto Programs Auto-ranging Power Supply Replaceable Fuse User-Serviceable
Keep this User Manual for future use. If you sell the product to another user, be sure to give this document to the next owner.
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 5 of 27

2. INTRODUCTION

Product Overview

DMX Out
Safety Loop
Fuse Holder
DMX In
Power In
Power Out
Control Panel and Button Menu
IR Sensor
Indicator LED
Page 6 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1

Product Dimensions

340 mm
13.4 in
15.4 in
392 mm
9.7 in
248 mm
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 7 of 27

AC Power

ranging power supply and it can work with
circuit breaker, power outlet, and
(circuit breaker or fuse). Make
an appropriate electrical ground to avoid the risk of
a rheostat (variable resistor) or dimmer circuit, even

Fuse
Replacement

3. SETUP

The Intimidator™ Spot 355Z IRC has an auto­an input voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements ( wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit sure the product has electrocution or fire.
Never connect the product to if the rheostat or dimmer channel serves only as a 0 to 100% switch.
1. Disconnect the product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove the blown fuse.
4. Replace with a fuse of the same type and rating.
5. Screw the fuse holder cap back in place and reconnect power.
Disconnect the product from power before replacing the fuse.
Always replace a blown fuse with another of the same type and rating.
Page 8 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1

Power Linking

Power Linking
units on 120 VAC or up to
The power linking diagram shown above corresponds to the North American
in other markets, you must
distributor as power linking connectors and
1st Product
2nd Product
3rd Product
Other products
The product provides power linking via the IEC outlet located in the back of the unit.
Diagram
You can power link up to 4 Intimidator™ Spot 355Z IRC 7 Intimidator™ Spot 355Z IRC units on 230 VAC.
version of the product ONLY! If using the product consult with the local Chauvet requirements may differ in your country or region.
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 9 of 27

Mounting

, read and follow the safety recommendations indicated in
may be mounted in any position; however, make sure
for weight
Mount the
always consider the length of the
on the
Rubber Feet (x4)
Safety Loop
Attachment Point
Bracket
Attachment (x2)
Before mounting the product the Safety Notes.

Orientation

The Intimidator™ Spot 355Z IRC adequate ventilation is provided around the product.

Rigging

Before deciding on a location for the product, always make sure there is easy access to the product for maintenance and programming purposes.
Make sure that the structure or surface onto which you are mounting the product can support the product’s weight. See the Technical Specifications information. The CLP-15 cla m p from Chauvet is appropriate for this product.
When mounting the product overhead, always use a safety cable. product securely to a rigging point, whether an elevated platform or a truss.
When rigging the product onto a truss, you should use a mounting clamp of appropriate weight capacity.
When po wer linking m ultiple products, you must power linking cable and mount the products close enough for the cable to reach.
The rubber feet also serve as floor supports. When mounting the product floor, make sure that the product and cables are away from people and vehicles.
Mounting Diagram
Page 10 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1

Control Panel
Operation

To access the control panel functions, use the four buttons located underneath the
<ENTER>

Menu Map

Main Level
Programming L evels
Description
Address
001–512
Sets the DMX starting address
09CH
15CH
Auto
Selects auto program
Sound
Selects Sound-Active mode
Slave
Selects Slave mode
IR
Selects infrared control
OFF
Normal pan operation
ON
Reverse pan operation
OFF
Normal tilt operation
ON
Reverse tilt operation
OFF
Normal display
ON
Reverse display
540
Selects the 540° p an an gl e ran ge
360
Selects the 360° p an an gl e ran ge
180
Selects the 180° p an an gl e ran ge
270
Selects the 270° ti lt an gl e ra nge
180
Selects the 180° ti lt an gl e ra nge
090
Selects the 90° tilt angle range
Sensitivity
001–100
Sets sound sensitivity
Reset
Resets the product
Factory Set
Loads factory defaults
Ver: VX.X
Displays the software version
Running Mode: XXXXX
Displays the current running mode
Dmx Address: XXX
Displays the current DMX address
Temperature: XXX
Displays the LED temperature in Celsius

4. OPERATION

display.
Button Function
<MODE/ESC>
<UP>
<DOWN>
Press to find an operation mode or to back out of the current menu option
Press to scroll up the list of options or to find a higher value Press to scroll down the list of options or to find a lower value Press to activate a menu option or a selected value
Run Mode
Setup
Sys Info
DMX
Pan Reverse
Tilt Reverse
Screen Reverse
Pan Angle
Tilt Angle
Selects DMX mode
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 11 of 27
Configuration
When selecting a starting DMX address, always consider the number of DMX channels
choose a starting address that is too high, you could
download the DMX Primer from
DMX
personality and
Set the product in DMX mode to control with a DMX controller.
(DMX)
1. Connect the product to a suitable power outlet.
2. Turn the product on.
3. Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the product.

Starting Address

the selected DMX mode uses. If you restrict the access to some of the product’s channels.
The Intimidator™ Spot 355Z IRC uses up to 15 DMX channels in its 15-channel DMX mode, which defines the highest configurable address to 498.
If you are not familiar with the DMX protocol,
www.chauvetlighting.com.
To select the starting address, do the following:
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Address.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select the starting address.
5. Press <ENTER>.
The Intimidator™ Spot 355Z IRC has two DMX personalities, a 9-channel
Personalities
a 15-channel personality. To choose which DMX personality to use, follow the steps below:
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Run Mode.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select DMX.
5. Press <ENTER>.
6. Use <UP> or <DOWN> until either 15CH (to choose the 15-channel personality) or 09CH (to choose the 9-channel personality) shows on the display.
7. Press <ENTER>.
Page 12 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1

DMX ASSIGNMENTS

15CH

Channel
Function
Value
Percent/Setting
1
Pan
000ó255
0–540°
2
Fine Pan
000ó255
Fine control of pan
3
Tilt
000ó255
0–270°
4
Fine Tilt
000ó255
Fine control of tilt
5
Speed
000ó255
Pan/Tilt speed (fast to slow)
000ó006
White
007ó013
Yellow
014ó020
Pink
021ó027
Green
028ó034
Red
035ó041
Light Blue
042ó048
Kelly Green
049ó055
Orange
056ó063
Dark Blue
064ó070
White + Yellow
071ó077
Yellow + Pink
078ó084
Pink + Green
085ó091
Green + Red
092ó098
Red + Light Blue
099ó105
Light Blue + Kelly Green
106ó112
Kelly Green + Orange
113ó119
Orange + Dark Blue
120ó127
Dark Blue + White
128ó191
Color cycle rainbow with increasing speed
Reverse color cycle rainbow with increasing speed
6 Color Wheel
192ó255
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 13 of 27
15CH
Channel
Function
Value
Percent/Setting
064ó071
Gobo 7 shake (slow to fast)
072ó079
Gobo 6 shake (slow to fast)
080ó087
Gobo 5 shake (slow to fast)
088ó095
Gobo 4 shake (slow to fast)
096ó103
Gobo 3 shake (slow to fast)
104ó111
Gobo 2 shake (slow to fast)
112ó119
Gobo 1 shake (slow to fast)
120ó127
Open
128ó191
Cycle gobos (slow to fast)
192ó255
Reverse cycle gobos (slow to fast)
000ó063
Index
064ó147
Rotate (slow to fast)
148ó231
Reverse rotate (slow to fast)
232ó255
Bounce
000ó007
Open
008ó012
Prism on
013ó130
Prism rotate (slow to fast)
131ó247
Reverse prism rotate (slow to fast)
248ó255
Prism effec t s
10
Focus
000ó255
Motorized focus (big to small)
11
Dimmer
000ó255
0–100%
000ó003
Closed
004ó007
Open
008ó076
Strobe (slow to fast)
077ó145
Pulse
146ó215
Random open and close
216ó255
Open
000ó063
7 Gobo Wheel
8 Gobo Rotation
9 Prism
12 Shutter
Page 14 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
15CH
Channel
Function
Value
Percent/Setting
000ó007
No function
008ó015
Blackout pan/tilt movement
016ó023
Blackout color wheel movement
024ó031
Blackout gobo wheel movement
032ó039
Disable pan/tilt/color wheel movement blackout
040ó047
Disable pan/tilt/gobo wheel movement blackout
048ó055
Disable all movement blackout
056ó095
No function
096ó103
Reset pan
104ó111
Reset tilt
112ó119
Reset color wheel
120ó127
Reset gobo wheel
128ó135
Reset gobo rotation
136ó143
Reset prism
144ó151
Reset focus
152ó159
Reset all channels
160ó255
No function
000ó007
No function
008ó135
Automatic programs 1–8
136ó255
Sound-Active programs 1–8
15
Zoom
000ó255
Motorized zoom (big to small)
13 Control Function
14 Movement Macros
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 15 of 27

09CH

Channel
Function
Value
Percent/Setting
1
Pan
000ó255
0–540°
2
Tilt
000ó255
0–270°
000ó006
White
007ó013
Yellow
014ó020
Pink
021ó027
Green
028ó034
Red
035ó041
Light Blue
042ó048
Kelly Green
049ó055
Orange
056ó063
Dark Blue
064ó070
White + Yellow
071ó077
Yellow + Pink
078ó084
Pink + Green
085ó091
Green + Red
092ó098
Red + Light Blue
099ó105
Light Blue + Kelly Green
106ó112
Kelly Green + Orange
113ó119
Orange + Dark Blue
120ó127
Dark Blue + White
128ó191
Color cycle rainbow with increasing speed
Reverse color cycle rainbow with increasing speed
064ó071
Gobo 7 shake (slow to fast)
072ó079
Gobo 6 shake (slow to fast)
080ó087
Gobo 5 shake (slow to fast)
088ó095
Gobo 4 shake (slow to fast)
096ó103
Gobo 3 shake (slow to fast)
104ó111
Gobo 2 shake (slow to fast)
112ó119
Gobo 1 shake (slow to fast)
120ó127
Open
128ó191
Cycle gobos (slow to fast)
192ó255
Reverse cycle gobos (slow to fast)
000ó063
Index
064ó147
Rotate (slow to fast)
148ó231
Reverse rotate (slow to fast)
232ó255
Bounce
3 Color Wheel
4 Gobo Wheel
5 Gobo Rotation
192ó255
000ó063
Page 16 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
09CH
Channel
Function
Value
Percent/Setting
000ó007
Open
008ó012
Prism on
013ó130
Prism rotate (slow to fast)
131ó247
Reverse prism rotate (slow to fast)
248ó255
Prism effec t s
7
Focus
000ó255
Motorized focus (big to small)
000ó003
Closed
004ó007
Open
008ó076
Strobe (slow to fast)
077ó145
Pulse
146ó215
Random open and close
216ó255
Open
9
Zoom
000ó255
Motorized zoom (big to small)
6 Prism
8 Shutter
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 17 of 27

Configuration
(Standalone)

to a DMX string connected to a DMX controller.
s in standalone mode may transmit DMX signals that could interfere with
Manual Pan/Tilt
Set the product in one of the standalone modes to contr ol without a DMX controller.
Connect the product to power.
Never connect a product that is operating in any standalone mode (either Automatic or Sound-Active) Product the DMX signals from the controller.
Sound-Active
Sound Sensitivity
Automatic Mode
Operation
Mode
To enable the Sound-Active mode, do the following.
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Run Mode.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Sound.
5. Press <ENTER>.
The product will only respond to low frequencies of music (bass and drums).
To set the sound sensitivity, do the following.
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Sensitivity.
5. Press <ENTER>.
6. Use <UP> or <DOWN> to select 001–100, low to high.
7. Press <ENTER>. To enable the Automatic mode:
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Run Mode.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Auto.
5. Press <ENTER>. To select whether you want the Intimidator™ Spot 355Z IRC to operate with normal
panning or inverted panning, do the following.
1. Press <MODE/ESC>.
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Pan Reverse.
5. Press <ENTER>.
6. Use <UP> or <DOWN> to select ON or OFF.
7. Press <ENTER>. To select whether you want the Intimidator™ Spot 355Z IRC to operate with normal
tilting or inverted tilting, do the following:
1. Press <MODE/ESC>.
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Tilt Reverse.
5. Press <ENTER>.
6. Use <UP> or <DOWN> to select ON or OFF.
7. Press <ENTER>.
Page 18 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
Pan/Tilt Angle
Intimidator™ Spot
You are able to select the range for the pan and tilt angles on the
Range
Display
355Z IRC to achieve the effect you like. To select which pan angle range to use, do the follow ing.
1. Press <MODE/ESC>.
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Pan Angle.
5. Press <ENTER>.
6. Use <UP> or <DOWN> to select 540, 360, or 180.
7. Press <ENTER>. To select which tilt angle range to use, do the following.
1. Press <MODE/ESC>.
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Tilt Angle.
5. Press <ENTER>.
6. Use <UP> or <DOWN> to select 270, 180, or 090.
7. Press <ENTER>. You are able to flip the LED display for easy readability in any mounting situation.
To select your display angle:
1. Press <MODE/ESC>.
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Screen Reverse.
5. Press <ENTER>.
6. Use <UP> or <DOWN> to select ON or OFF.
7. Press <ENTER>.
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 19 of 27
Master/Slave
units (the slaves) without
te in either Automatic
ode. Once
all the slave units before connecting the master unit to the DMX
Never connect a DMX controller to a DMX string configured for Master/Slave
may interfere with the signals from the

Reset Options

option will restart the product, but does not change any settings. Using the
option will clear out all customized settings and return the settings to the
, do the
System
The Master/Slave mode allows a single Intimidator™ Spot 355Z IRC unit (the mast er ) to
Mode
control the actions of one or more Intimidator™ Spot 355Z IRC the need of a DMX controller. The master unit will be set to opera or Sound-Active mode, while the slave units will be set to operate in Slave m set and connected, the slave units will operate in unison with the master unit.
Configure the units as indicated below.
Slave units:
1. Press <MODE/ESC>.
2. Use <UP> or <DOWN> to choose Run Mode.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to select Slave.
5. Press <ENTER>.
6. Follow the instructions to set the DMX address to 001.
7. Connect the DMX input of the first slave unit to the DMX output of the master unit.
8. Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit.
9. Finish setting and connecting all the slave units.
Master unit:
1. Set the master unit to operate in either Automatic or Sound-Active mode.
2. Make the master unit the first unit in the DMX daisy chain.
Information
Configure
daisy chain.
operation because the controller master unit.
Do not connect more than 31 slave units to the master unit.
The Reset Factory Reset factory defaults To reset the software on the Intimidator™ Spot 355Z IRC following:
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Setup.
3. Press <ENTER>.
4. Use <UP> or <DOWN> to choose Reset or Factory Reset.
5. Press <ENTER>.
To view information about the Intimidator™ Spot 355Z IRC:
1. Press <MODE/ESC>
2. Use <UP> or <DOWN> to choose Sys Info.
3. Press <ENTER>. The current information about the product will show on the display.
Page 20 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
IR mode allows the product to be controlled with an infrared remote controller. The
adjust the color, speed and
IRC-6 Operation
Be sure the IRC-6 remote is pointing directly at the product and there is nothing in
Some of the buttons on the remote work differently than what is indicated on their
The list below describes which features each button controls.
IR Mode
IRC-6 can remotely set the product to various modes; sensitivity; and set the strobe. To set the product to IR mode, do the following:
1. Make sure the product is plugged into a power source and not connected to a DMX cable.
2. Press <MODE/ESC>.
3. Use <UP> or <DOWN> to choose Run Mode.
4. Press <ENTER>.
5. Use <UP> or <DOWN> to choose IR.
6. Press <ENTER> and the IR indicator on the front of the Intimidator Spot 355Z IRC lights up.
between the remote and the product.
labels. For example:
<MANUAL> changes the GOBO pattern.
<A>, <UV>, and <W> control the Blackout function.
Please read the next section carefully.
<BLACKOUT> - Turns LEDs on and off.
<AUTO> - Activates Auto mode. Use the <+> and <-> buttons to cycle through Auto
modes.
<SOUND> - Activates Sound mode.
<STROBE> - Activates the strobe. Use the <+> and <-> buttons to cycle through
strobe speeds.
<SPEED> - Adjusts the movement speed. Use the <+> and <-> buttons to cycle through movement speeds.
<SENSITIVITY> - Adjusts sound sensitivity. Use the <+> and <-> buttons to cycle through sound sensitivity levels.
<%> - Adjusts the brightness of the LEDs. Use the <+> and <-> buttons to increase or decrease the brightness of the LEDs.
<MANUAL> - Changes the GOBO pattern. Use the <+> and <-> buttons to scroll through the GOBO options.
<FADE/SNAP> or <FADE> - Adjusts the speed and type of color fades. Press the button to switch between fade and snap color changes. Use <+> and <-> to increase or decrease the speed of the color changes.
<R> - Adjusts the red color in the LEDs. Use the <+> and <-> buttons to increase or decrease the red color in the LEDs.
<G> - Adjusts the green color in the LEDs. Use the <+> and <-> buttons to increase or decrease the green color in the LEDs.
<B> - Adjusts the blue color in the LEDs. Use the <+> and <-> butt ons to incr eas e or decrease the blue color in the LEDs.
<+> - Increases values for controls as descri bed abov e.
<-> - Decreases values for controls as described above.
<0><9> - Activates specific Auto modes. Can be used as a shortcut for the
combination of the <AUTO> button and the <+> and <-> buttons.
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 21 of 27
Passcode
protected mode which allows you
The Intimidator™ Spot 355Z IRC contains a passcode-
Protection
to calibrate and troubleshoot any small issues you may have during normal operation. In order to access this mode, do the following:
1. Press and hold <MODE/ESC> for at least 10 seconds.
2. Use <UP> and <DOWN> to enter the passcode: 2323.
3. Press <ENTER>.
In this mode there are several options for adjustment:
Gobo Wheel Adjust G128 Color Wheel Adjust C128
Focus Adjust F128 Prism Adjust L000
Lamp Brightness Adjust d000
Parameter Programming Steps Description
Pan Adjust P128
Tilt Adjust t128
Manually adjust the pan angle Manually adjust the tilt angle Manually adjust the gobo wheel Manually adjust the color wheel Manually adjust the focus Manually adjust the prism Manually adjust the starting
brightness of the lamp
Page 22 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
Changing
, do not remove the gobo
Easy-access Panel
Gobo Replacement Diagram
Expansion Ring
Wedding-Ready Gobo Pack
Gobo Wheel Detail Views
Gobos
Gobo Holder Removal
To change the gobos in the Intimidator™ Spot 355Z IRC wheel. Simply:
1. Turn off and disconnect product from power outlet.
2. Place the product on a flat, level surface with the front facing up.
3. Access the gobo plate by removing the cover on the moving head. By hand,
gently pry up the right side, then push right with the indented handles.
NOTE: If you expose the driver board, you are on the wrong side of the head. Replace the cover immediately and remove the cover on the opposite side of the moving head.
4. Rotate the gobo wheel until the gobo that needs replacing is accessible.
5. Separate the gobo holder assembly away from the gobo wheel by pushing it
forward and up. Be careful not to push the gobo out of the gobo plate.
6. Extract the gobo holder by pulling it backwards out of the product.
7. On a flat surface, remove the expansion ring that holds the gobo in place and
remove the gobo from the gobo plate.
8. Insert a new gobo and hold it in place with the expansion ring.
9. To re-insert the new gobos, slide the tip of the gobo holder under the pressure
plate near the center of the gobo wheel.
10. Push the gobo holder assembly inwards. DO NOT force the gobo holder into
the gobo wheel slot. Slightly move the holder from side-to-side if needed to get it to seat properly. If correctly installed, the bottom of the holder will be flush with the gobo wheel.
11. Push cover back into position.
Gobo
Gobo Holder Assembly
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 23 of 27
Product
Dust build up reduces light output performance and can cause overheating. This can
To maintain optimum performance and
However,
(or dry compressed air) and a soft brush to remove dust collected on
Do not spin the cooling fans using compressed air because you could damage

5. TECHNICAL INFORMATION

Maintenance
minimize wear, you should clean your lighting products at least twice a month. be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
1. Unplug the product from power.
2. Wait until the product is at room temperature.
3. Use a vacuum the external surface/vents.
4. Clean all glass/transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue.
6. Softly drag any dirt or grime to the outside of the glass/transparent surface.
7. Gently polish the glass/transparent surfaces until they are free of haze and lint.
Always dry the glass/transparent surfaces carefully after cleaning them.
them.
lead to reduction of the light source’s life.
Page 24 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1

General Info

To return a product or request support:
If you live outside the U.S., United Kingdom, Ireland, or Mexico, contact your
U.S., UK,
Ireland, and
Call the corresponding Chauvet Technical Support office and request a Return Merchandise
without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA
Before sending the product, clearly write the following information on a piece of paper and place
will be your responsibility. FedEx packing or double-boxing are recommended.
reserves the right to use its own discretion to repair or replace

RETURNS

Mexico
In the U.S., contact Chauvet World Headquarters (see below).
In the UK or Ireland, contact Chauvet Europe Ltd. (see below).
In Mexico, contact Chauvet Mexico (see below).
In any other country, DO NOT contact Chauvet. Contact your distributor. See
www.chauvetlighting.com for distributors outside the U.S., United Kingdom,
Ireland, or Mexico.
distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website for contact details.
Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the reason for the return. You must send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned
number directly on the box.
it inside the box:
Your name
Your address
Your phone number
RMA number
A brief description of the problem
Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging
Chauvet returned product(s).
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 25 of 27
Contact
WORLD HEADQUARTERS - Chauvet
General Information
Toll free: (800) 762-1084
Technical Support
World Wide Web www.chauvetlighting.com
UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd.
General Information
Fax: +44 (0)1773 511110
Technical Support
MEXICO - Chauvet Mexico
General Information
Voice: +52 (728) 285-5000
Technical Support
contact your dealer. Follow their instruc tions to request
support or to return a product. Visit our website for contact details.
Us
Address: 5200 NW 108th Avenue Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560
Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT Voice: +44 (0)1773 511115
Address: Av. Santa Ana 30 Parque Industrial Lerma Lerma, Mexico C.P. 52000
Outside the U.S., United Kingdom, I reland, or Me xico,
Voice: (954) 577-4455 (Press 4) Fax: (954) 756-8015 Email: tech@chauvetlighting.com
Email: uktech@chauvetlighting.com World Wide Web www.chauvetlighting.co.uk
Email: servicio@chauvet.com.mx World Wide Web www.chauvet.com.mx
Page 26 of 27 Intimidator™ Spot 355Z IRC User Manual Rev. 1
Dimensions and
Length
Height
(pointing upward)
13.4 in (340 mm)
9.7 in (248 mm)
18 in (456 mm)
27.4 lb (12.4 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Voltage Selection
Switching (internal)
100 to 240 V, 50/60 Hz
Auto-ranging
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
309 W
283 W
Operating
3.2 A
1.6 A
Power linking units
4 units
7 units
Fuse
F 5 A, 250 V
F 5 A, 250 V
Power I/O
US/Worldwide
UK/Europe
Power input connector
IEC
IEC
Power output connector
Edison
IEC
Power Cord plug
Edison (US)
Local plug
Light Source
Type
Power
Lifespan
LED
90 W
50,000 hours
Color
Quantity
Current
White
1
3.2 A
Photometrics
Parameter
Illuminance (10°)
35,225 lx @ 2 m
Illuminance (17°)
11,800 lx @ 2 m
Zoom angle
10º to 17º
Strobe Rate
0 to 23 Hz
Pan & Tilt
540°
270°
Pan
Tilt
24 mm outside
1.1 mm maximum thickness
Thermal
Maximum External Temp.
Cooling System
104 °F (40 °C)
Fan-cooled
DMX
I/O Connectors
Connector Type
Channel Range
3-pin XLR
Sockets
9 or15
Ordering
Product Name
Item Code
UPC Number
Intimidator™ Spot 355Z IRC
08010885
781462212339

6. TECHNICAL SPECIFICATIONS

Weight
Width
Weight
Pan/Tilt Ranges
Gobo Size
540°, 360°, 180°
20 mm image
270°, 180°, 90°
Intimidator™ Spot 355Z IRC User Manual Rev. 1 Page 27 of 27
Loading...