Contact Us ........................................................................................................................14
Page 2 of 2 Hurricane™ 1101 User Manual Rev. 1
Page 3
What Is
Unpacking
Instructions
and check the container to make sure all the
included accessories) appear damaged from
missing components or parts, damage not related to shipping,
Text
1—512
A range of values
50/60
A set of values
Settings
A menu option
Menu > Settings
A sequence of menu options
<Enter>
A button
Symbols
Critical installation, configuration, or operation information. Not
damage to the product, or cause harm to the operator.
Disclaimer
are subject to change
ity for any errors or omissions,
and reserves the right to revise or recreate this manual at any time. Download the latest
1.BEFORE YOU BEGIN
Included
Claims
Conventions
• Hurricane™ 1101
• Manual Fog Controller (FC-M)
• Hanging Bracket with Mounting
Hardware
Carefully unpack the product immediately
parts are in the package and are in good condition.
If the box or the contents (the product and
shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet.
Failure to report damage to the carrier immediately may invalidate your claim. In
addition, keep the box and contents for inspection.
For other issues, such as
or concealed damage, file a claim with Chauvet within 7 days of delivery.
Convention Meaning
Symbol Meaning
• Warranty Card
• Quick Reference Guide
The information and specifications contained in this User Manual
without notice. Chauvet assumes no responsibility or liabil
Electronically published by Chauvet in the United States of America.
Author Date Editor Date
M. Trouard 06/23/2014 A. Leon 10/23/14
following these instructions may make the product not work, cause
Important installation or configuration information. The product
may not function correctly if this information is not used.
Useful information.
HurricaneTM 1101 User Manual Rev. 1 Page 3 of 3
Page 4
Product at a
x
x
x
P
x
P
x
x
x
x
Safety Notes
Do not add perfume, alcohol, gasoline, or any other flammables to the fog fluid.
completely disconnect the product from power via breaker or by unplugging it.
Keep this User Manual for future use. If you sell the product to another user, be sure to
FCQ (Fog Cleaner Quart) was specifically developed by Chauvet to clean your
cleanings, to increase the life of your fogger.
Glance
Use on Dimmer
Outdoor Use
Sound-Activated
DMX
Master/Slave
These notes i nclude important information about the mounting, usage, and maintenance
of this product; read before using the product.
• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• Always disconnect the product from the power source before cleaning or replacing
the fuse.
• Make sure the power cord is not crimped or damaged.
• Never disconnect the product from power by pulling or tugging on the cord.
• If mounting the product overhead, always secure to a fastening device using a
safety cable.
• Make sure there are no flammable materials close to the product when operating.
• Do not touch the product’s housing when operating because it may be very hot.
• Do not mount the product on a flammable surface (linoleum, carpet, wood, paper,
carton, plastic, etc.).
•The product’s nozzle is very hot during operation and it remains hot for a long time
after operation has stopped.
•The fog exits the nozzle at a very high temperature. Keep a minimum distance of
6.5 ft (2 m) from the nozzle to the nearest object.
• Do not use the product as a space heater .
• Do not drink or come in contact with the fog fluid. If you do, call your local
emergency service (911 in the US) for help.
•
Auto Programs
Fixed voltage (120 V or 230 V)
Replaceable Fuse
User-Serviceable
Duty Cycle
•Always make sure that the voltage of the outlet to which you are connecting the
product is within the range stated on the decal or rear panel of the product.
•The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not
expose the product to rain or moisture.
•Always install the product in a location with adequate ventilation, at least 20 in
(50 cm) from adjacent surfaces.
• Be sure that no ventilation slots on the product’s housing are blocked.
• Never connect the product to a dimmer.
• Make sure to replace the fuse with another of the same type and rating.
• Never carry the product from the power cord or any moving part. Always use the
hanging/mounting bracket.
•The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the
product at higher temperatures.
• In the event of a serious operating problem, stop using the product immediately.
• Never try to repair the product. Repairs carried out by unskilled people can lead to
damage or malfunction. Contact the nearest authorized technical assistance center.
• This product is not intended for permanent installation.
• Use only CHAUVET® water-based fog fluid.
• Drain the tank before transporting the product.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use
give this document to the next owner.
Hurricane™ 1101. Make sure you use FCQ regularly, no longer than 90 days between
Page 4 of 4 Hurricane™ 1101 User Manual Rev. 1
Page 5
2.INTRODUCTION
Overview
Fuse Holder
Manual Fog
Button
Low Fluid
Indicator
Fog Fluid Tank
Fluid Level
Indicator
Manual
Socket
Wireless
Socket
Power In
Rear Panel View
Safety Loop
Controller
Controller
HurricaneTM 1101 User Manual Rev. 1 Page 5 of 5
Page 6
Dimensions
8.8 in
222 mm
4.8 in
124 mm
9.9 in
251 mm
9.3 in
235 mm
7 in
180 mm
7 in
180 mm
9.6 in
243 mm
Page 6 of 6 Hurricane™ 1101 User Manual Rev. 1
Page 7
AC Power
1101 has a fixed voltage power supply and it can work with an input
, and
’s back panel, or
’s specifications chart. The listed current rating indicates the
(circuit breaker or fuse). Make
has an appropriate electrical ground to avoid the risk of
a rheostat (variable resistor) or dimmer circuit, even
Fuse
3.SETUP
Replacement
This HurricaneTM
voltage of either 120 VAC, 60 Hz or 230 VAC, 50 Hz, depending on the specific model.
To determine the product’s power requirements (circuit breaker, power outlet
wiring), use the current value listed on the label affixed to the product
refer to the product
product’s average current draw under normal conditions.
Always connect the product to a protected circuit
sure the product
electrocution or fire.
Never connect the product to
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
1. Disconnect the product from power.
2. With a Phillips #2 head screwdriver, unscrew the fuse holder
cap from the housing.
3. Remove the blown fuse.
4. Replace with a fuse of the same type and rating.
5. Screw the fuse holder cap back in place and reconnect
power.
Disconnect the product from power before replacing the fuse.
Always replace a blown fuse with another of the same type and rating.
HurricaneTM 1101 User Manual Rev. 1 Page 7 of 7
Page 8
Mounting
, read and follow the safety recommendations indicated in
Orientation
This product may not be tilted. This product should only be mounted/used on a
Mount the
appropriate
surface mounting. When
While operating the Hurricane™ 1101, make sure there is adequate fog fluid in the
more fog fluid to
Bracket Adjustment Knob (x2)
Bracket
Fog Fluid Tank
clamp
Rubber Feet for
Floor Mounting
Safety
Before mounting the product
the Safety Notes.
level surface.
Rigging
•Before deciding on a location, always make sure there is easy access to the product
for maintenance and fluid replenishment.
•Make sure that the structure or surface onto which you are mounting the product
can support the product’s weight (see the Technical Specifications
).
•When mounting the product overhead, always use a safety cable.
product securely to a rigging point, such as an elevated platform or a truss.
•When rigging the product onto a truss, you should use a mounting clamp of
appropriate weight capacity. The bracket has 13-mm holes, which are
for this purpose.
•The rubber feet also serve as floor supports and allow for
mounting the product on the floor, make sure that the product and cables are away
from people and vehicles.
Mounting Clamp
(such as CLP-15
from Chauvet)
Mounting
Loop
Mounting Diagram
Nozzle
Safety Cable
(works with CH-05
from Chauvet)
machine to prevent pu mp and heater damage. Wh en the fog f luid level b ecomes low , as a
safety feature, the heat s ensor will make a very loud noise. Simply add
continue using the Hurricane™ 1101.
Page 8 of 8 Hurricane™ 1101 User Manual Rev. 1
Page 9
Remote or
Manual
Operation
The Hurricane™ 1101 can be operated manually, or with the included manual fog
The Manual button is located on the rear of the unit.
Manual Fog
Controller
1. Connect the fog machine to power.
The FC-M button is momentary, which means that the fog machine will only output
while the button is pressed. Once the button is released, the fog will stop
Fluid Tank
, as
Note: The Hurric an e™ 1101 may output fog for a short duration to allow for a selfchecking cy cle.
Ready Status
LED
Manual Fog
Button
4.OPERATION
(FC-M)
FC-M
Overview
controller. Two other optional remote controls are also available: a timer remote (FC-T)
and a wireless remote (FC-W).
See the product Overview.
2. Plug the manual fog controller (FC-M) into the Manual Controller socket on the rear of
the fog machine.
3. Wait for the Status LED to turn green.
4. Press the button located on the controller to trigger the fog output.
outputting.
The FC-M has a magnetic back that can affix to most metal surfaces for easy placement
while the unit is in use.
Indicator LED on the back of the Hurricane™ 1101 shows the status of the fogger
Indicator LED
follows:
•Orange - pump is not detecting fluid
HurricaneTM 1101 User Manual Rev. 1 Page 9 of 9
Page 10
Fogger
hours of continuous
Fog Cleaner Quart (FCQ) through the system to prevent the
between cleanings, to increase the life of your product.
Storage
, run FCQ through the system as described in the cleaning
. Do not refill the tank with
Cleaning the system prior to storage will help prevent
on a monthly basis to achieve the best
5.TECHNICAL INFORMATION
Do not allow the fogger to become clogged. After every 40
Maintenance
operation, use CHAUVET®
accumulation of particulate matter in the heating element.
The recommended cleaning procedure is as follows.
1. Unplug the product from power.
2. Empty all fog fluid from the machine.
3. Add cleaning solution to the tank.
4. Connect the product to power and allow it to warm up.
5. Run the unit in a well-venti late d area until the ta nk is almost empty . Do not allow the pump to run dry.
6. Refill with fogger fluid to continue using the fogger. Run the machine briefly to clear
any remaining cleaning solution from the pump and heater.
Do Not operate the machine without fluid at any time.
Fog Cleaner Quart (FCQ) was specifically developed by Chauvet to clean your
Hurricane™ 1101. Make sure you use FCQ regularly, no longer than 90 days
Before storing the fogger
procedure above; however, only follow steps 1 through 5
fog fluid if storing the fogger.
any particles from condensing inside the pump or heater while not in use.
Test-run your Hurricane™ 1101
performance.
Page 10 of 10 Hurricane™ 1101 User Manual Rev. 1
Page 11
Make sure there is fluid in the tank
and allow the fog fluid to flow properly
Prime by setting output to the highest setting
Turn off the product for 5 seconds, and then turn it
Customer Service.
Clean thoroughly with CHAUVET® FCQ. For full
CHAUVET® water-based haze fluid.
CHAUVET® water-based haze fluid.
Blocked pipes
Contact Customer Service
Failing part
Contact Customer Service
80% of the breaker or fuse nominal current
lines
Change to another outlet
Loose or damaged power cord
Check the power cord
type and rating
Internal problem
Send product for repair
Low/No Fluid
Refill product with fluid
Pump protection system
engaged
Release manual fog button, and press it again to
reset pump protection system
6.GENERAL TROUBLESHOOTING
Symptom
No output or short output
No output or spitting fluid
Fuse keeps blowing
Possible
Cause
Indicator
Status
Line blockage
or air in fluid
Orange
line
Incorrect fluid Off
Incorrect fluid
Off
Excessive load on the circuit
Short circuit along the power
No energy on power outlet
Possible Action
Turn fog machine 45° to flatten out the bubble
back on. Repeat as necessary.
Note: After more than 10 attempts, contact
instructions, see Fogger Maintenance. Refill with
Clean thoroughly with CHAUVET® FCQ. For full
instructions, see Fogger Maintenance
. Refill with
Make sure that the total load does not exceed
Check the power lines and power cords
Check power outlet
Product does not power
up
Blown fuse
Product stops pumping/
Loud noise
If you still experience problems after trying the solutions presented here, contact
Chauvet Technical Support. See Contact Us.
Replace blown fuse with a good one of the same
HurricaneTM 1101 User Manual Rev. 1 Page 11 of 11
Page 12
Dimensions and
Length
Width
Height
Weight
9.9 in (252 mm)
9.6 in (243 mm)
8.8 in (222 mm)
7.4 lb (3.4 kg)
Note: Dimensions in inches rounded to the nearest decimal digit.
Power
Power Supply Type
Range
Voltage Selection
120 VAC, 60 Hz or
230 VAC, 50 Hz
Parameter
120 V, 60 Hz
230 V, 50 Hz
Consumption
612 W
716 W
Operating / Inrush current
5.1 A
3.1 A
Fuse
F 8 A, 250 V
F 5 A, 250 V
Power I/O
US/Worldwide
UK/Europe
Power input connector
Hard-wired
Hard-wired
Power Cord plug
Edison (US)
Local plug
Operation
Heat-up Time
Tank Capacity
Fluid Consumption
5 min
0.3 gal (1.3 l)
30 ml/min
Fog Output
Output
8,000 cfm
Thermal
Maximum External Temp.
Cooling System
104 °F (40 °C)
Convection
Ordering
Product Name
Item Code
Item Number
HurricaneTM 1101 (120 V)
05070794
781462211424
HurricaneTM 1101 (230 V)
05070797
781462211455
7.TECHNICAL SPECIFICATIONS
Weight
Model-specific
Fixed
Page 12 of 12 Hurricane™ 1101 User Manual Rev. 1
Page 13
R
To return a product or request support:
, contact your
RMA
Support office and request a Return
. Be prepared to
provide the model number, serial number, and a brief description of the cause for the
its original box, and with its original packing
the following information on a piece of paper
properly. Any shipping damage resulting from inadequate
to use its own discretion to repair or replace returned
ETURNS
• In the U.S., contact Chauvet World Headquarters (see Contact Us).
• In the UK or Ireland, contact Chauvet Europe Ltd. (see Contact Us).
• In Mexico, contact Chauvet Mexico (see Contact Us).
• In any other country, DO NOT contact Chauvet. Contact your distributor. See
www.chauvetlighting.com
for distributors outside the U.S., United Kingdom, Ireland, or Mexico.
If you live outside the U.S., United Kingdom, Ireland, or Mexico
distributor of record and follow their instructions on how to return Chauvet
products to them. Visit our website for contact details.
Call the corresponding Chauvet Technical
Merchandise Authorization (RMA) number before shipping the product
return.
You must send the merchandise prepaid, in
and accessories. Chauvet will not issue call tags.
Clearly label the package with the RMA number. Chauvet will refuse any product
returned without an RMA number.
Write the RMA number on a properly affixed label. DO NOT write the RMA number
directly on the box.
Before sending the product, clearly write
and place it inside the box:
• Your name
• Your address
• Your phone number
• RMA number
• A brief description of the problem
Be sure to pack the product
packaging will be your responsibility. FedEx packing or double-boxing are
recommended.
Chauvet reserves the right
product(s).
HurricaneTM 1101 User Manual Rev. 1 Page 13 of 13
Page 14
C
WORLD HEADQUARTERS - Chauvet
General Information
Toll free: (800) 762-1084
Technical Support
World Wide Web www.chauvetlighting.com
UNITED KINGDOM AND IRELAND - Chauvet Europe Ltd.
General Information
Fax: +44 (0)1773 511110
Technical Support
MEXICO - Chauvet Mexico
General Information
Voice: +52 (728) 285-5000
Technical Support
Outside the U.S., United Kingdom, Ireland, or Mexico, contact your dealer. Follow their instructions to request support
or to return a product. Visit our website for contact details.