Omega™ 250C
Chauvet, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
TABLE OF CONTENT
BEFORE YOU BEGIN ...............................................................................................................................................................3
WHAT IS INCLUDED ...................................................................................................................................................................... 3
UNPACKING INSTRUCTIONS........................................................................................................................................................... 3
AC POWER................................................................................................................................................................................ 3
SAFETY INSTRUCTIONS ................................................................................................................................................................ 3
INTRODUCTION ........................................................................................................................................................................4
FEATURES ................................................................................................................................................................................. 4
DMX CHANNEL SUMMARY ........................................................................................................................................................... 4
PRODUCT OVERVIEW................................................................................................................................................................... 5
SETUP ........................................................................................................................................................................................6
LAMP ........................................................................................................................................................................................ 6
Lamp installation .................................................................................................................................................................................... 6
POWER ..................................................................................................................................................................................... 6
MOUNTING................................................................................................................................................................................. 7
Orientation ............................................................................................................................................................................................. 7
Rigging .................................................................................................................................................................................................. 7
MANUAL FOCUSING ..................................................................................................................................................................... 7
FUSE REPLACEMENT ................................................................................................................................................................... 7
OPERATING INSTRUCTIONS..................................................................................................................................................8
OPERATING MODES..................................................................................................................................................................... 8
Stand Alone .......................................................................................................................................................................8
Master/Slave......................................................................................................................................................................8
Master/Slave settings............................................................................................................................................................................. 8
Master/Slave Show Customization.......................................................................................................................................................... 9
DMX Mode.........................................................................................................................................................................9
Setting the starting address .................................................................................................................................................................... 9
APPENDIX................................................................................................................................................................................11
DMX PRIMER........................................................................................................................................................................... 11
Fixture Linking ..................................................................................................................................................................................... 11
DMX CHANNEL VALUES............................................................................................................................................................. 12
MAINTENANCE .......................................................................................................................................................................... 13
RETURNS PROCEDURE .............................................................................................................................................................. 13
CLAIMS ................................................................................................................................................................................... 13
GENERAL TROUBLESHOOTING..................................................................................................................................................... 14
TECHNICAL SPECIFICATIONS ....................................................................................................................................................... 15
DMX-250C User Manual 2 Revision: 5/17/2005 10:49 PM
BEFORE YOU BEGIN
What is included
Omega™ 250C (DMX-250C)
Power cord with plug
ELC 24V 250W MR-16 lamp
Diffusion filter an O-ring locking attachment (Installed)
Manual with Warranty Card
Unpacking Instructions
Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that
all parts are present, and have been received in good condition. Notify the shipper immediately and
retain packing material for inspection if any parts appear damaged from shipping or the carton itself
shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture
must be returned to the factory, it is important that the fixture be returned in the original factory box
and packing.
AC Power
To determine the power requirements for a particular fixture, see the label affixed to the back plate of
the fixture or refer to the fixture’s specific ations chart. A fixture’s listed current rating is its average
current draw under normal conditions. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel is used solely for a 0% to 100% switch. Before
applying power to a fixture, check that the source voltage matches the
fixture’s requirement. Check the fixture or device carefully to make sure that
if a voltage selection switch exists that it is set to the correct line voltage
you will use.
Figure 1 -
Warning! Verify that the power select switch on your unit matches the line voltage applied. All
fixtures must be connected to circuits with a suitable Earth Ground.
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive
this instruction booklet.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is
not higher than that stated on decal or rear panel of the
fixture.
This product is intended for indoor use only!
To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable
materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure
that no ventilation slots are blocked.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same
lamp source.
Secure fixture to fastening device using a safety chain.
Never carry the fixture solely by its head. Use its carrying
handles.
Maximum ambient temperature is Ta: 40°. Do not operate
fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself.
Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest
authorized technical assistance center. Always use the
same type spare parts.
Don’t connect the device to a dimmer pack.
Make sure power cord is never crimped or damaged.
Never disconnect power cord by pulling or tugging on the
cord.
Avoid direct eye exposure to lamp while it is on.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service,
please contact CHAUVET.
DMX-250C User Manual 3 Revision: 5/17/2005 10:49 PM
INTRODUCTION
The Omega™ 250C DMX-250C brings the latest automated intelligent lighting technology to a super
compact and affordable fixture. The Omega™ 250C features a super bright 250 watt halogen bulb
encased in a highly optimized dichroic reflector ensuring optimum lamp performance. DMX-512
control means total control of your light show and an internal microphone enables sound activated
programs to perform seamlessly. The Omega™ 250C is best suited for small clubs and mobile DJs.
Weighing only 15 lbs, any mobile DJ can truly appreciate its portability and extreme power. Ideal
show conditions would include 4 or more Omega™ 250Cs and an atmospheric effect device such as
a fogger or hazer.
Features
advanced 4 channel DMX-512 fixture
14 colors plus open
diffusion filter for color wash effect (installed)
electronic dimming
manual focus
reliable micro-stepping motors
built-in beat activated programs
built-in microphone
automatically enters stand-alone mode when no DMX signal is present
fan cooled
linkable via master/slave controller
programmable via any universal DMX controller
thermal fuse protection
switch-selectable power setting 115V/230V
2 year warranty
DMX Channel Summary
CHANNEL FUNCTION
1 Speed
2 Color
3 Strobe
4 Dimmer
DMX-250C User Manual 4 Revision: 5/17/2005 10:49 PM
Introduction
Adjust audio sensitivity to
Product Overview
Safety Hook
Attach safety cable to
this hook
DMX Input
Locking 3-pin XLR male
socket
DMX Output
Locking 3-pin XLR
female socket
Integrated Mic
Dipswitches
Provided for DMX
channel addressing
Audio Sensitivity
(POT)
improve fixture response
Voltage Selector
Choose either 115V or
230V operation
Manual Focus Lens Gun
Removable Diffusion Filter
Top Cover also
Lamp cover
Power Input
Fuse Holder
Hanging Bracket
(Yoke)
Yoke tensioning
knob
DMX-250C User Manual 5 Revision: 5/17/2005 10:49 PM