Chauvet LED-EQ, COLORtube EQ, LED-EQCON User Manual

Page 1
COLORtube EQ
COLORtube EQ Controller
USER MANUAL
LED-EQ
LED-EQCON
32-band audio spectrum visualizer
using LED tubes
CHAUVET, 3000 N 29th Ct, Hollywood, FL 33020 U.S.A
(800) 762-1084 – (954) 929-1115
FAX (954) 929-5560
www.chauvetlighting.com
2006-07-14/09:47
Page 2
Table of Content
BEFORE YOU BEGIN....................................................................................................................................................... 3
WHAT IS INCLUDED .......................................................................................................................................................................................................... 3
UNPACKING INSTRUCTIONS.............................................................................................................................................................................................. 3
AC POWER .....................................................................................................................................................................................................................3
SAFETY INSTRUCTIONS .................................................................................................................................................................................................... 3
INTRODUCTION............................................................................................................................................................... 4
FEATURES.......................................................................................................................................................................................................................4
PRODUCT OVERVIEW....................................................................................................................................................................................................... 4
SETUP .............................................................................................................................................................................. 5
POWER ........................................................................................................................................................................................................................... 5
MOUNTING ...................................................................................................................................................................................................................... 5
OPERATING INSTRUCTIONS.......................................................................................................................................... 6
CONNECTION DIAGRAM ...................................................................................................................................................................................................6
OPERATION ..................................................................................................................................................................................................................... 6
Program modes dipswitch chart ..............................................................................................................................................................................6
Fixture Addressing...................................................................................................................................................................................................8
COLORTUBE EQ CONTROLLER...................................................................................................................................................................................9
Controller options..................................................................................................................................................................................................... 9
Setup........................................................................................................................................................................................................................9
Operation .................................................................................................................................................................................................................9
Controller programs (chart)....................................................................................................................................................................................10
APPENDIX...................................................................................................................................................................... 11
RETURNS PROCEDURE .................................................................................................................................................................................................. 11
CLAIMS ......................................................................................................................................................................................................................... 11
TECHNICAL SPECIFICATIONS ..........................................................................................................................................................................................11
TECHNICAL SUPPORT ....................................................................................................................................................................................................11
COLORtube EQ User Manual 2 2006-07-14/09:47
Page 3
BEFORE YOU BEGIN
What is included
Unpacking Instructions
Immediately upon receiving a product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.
AC Power
To determine the power requirements for a particular product, see the label affixed to the back plate of the product or refer to the products specifications chart. A products listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power, check that the source voltage matches the products requirement.
(4) x COLORtube EQ LED tubes
(1) x LED-EQCON, (1) x 33ft Signal cable, (1) x 6.6ft Power cable
Tube mounting hardware Warranty Card & User Manual
Safety Instructions
Please read these instructions carefully, which includes important
information about the installation, usage and maintenance?
Please keep this User Guide for future consultation. If you
sell the unit to another user, be sure that they also receive this instruction booklet.
Always make sure that you are connecting to the proper
voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture.
This product is intended for indoor use only!  To prevent risk of fire or shock, do not expose fixture to
rain or moisture. Make sure there are no flammable materials close to the unit while operating.
The unit must be installed in a location with adequate
ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
Caution! There are no user serviceable parts inside the unit. Do not open the housing or
attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET.
Always disconnect from power source before servicing or
replacing lamp or fuse and be sure to replace with same lamp source.
Maximum ambient temperature is Ta: 40°C. Do not
operate fixture at temperatures higher than this.
In the event of serious operating problem, stop using the
unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled persons can lead to damage or malfunction. Please contact the nearest authorized technical assistance center.
Always use the same type spare parts.  Dont connect the device to a dimmer pack. Make sure power cord is never crimped or damaged.  Never disconnect power cord by pulling or tugging on the
cord.
COLORtube EQ User Manual 3 2006-07-14/09:47
Page 4
Microphone
Power input
Addressing dipswitch
Mode dipswitch
OFF
ON
6 5 4 3 2 1 4 3 2 1
INTRODUCTION
Features
FEATURES
32-band LED-tube audio spectrum visualizer 144 LEDs total
- Red (48), Green (48) and Blue (48)
Ultra bright LEDs 16 patterns, chases, color flows with variations plus blackout Low power consumption Up to 100,000-hour LED life span Master/Slave mode
ADDITIONAL FEATURES
Tube composition: milky white UV coated optically diffused polycarbonate Easy installation, energy saving and eco-friendly Water resistance rating: IP33 Temperature range: -20oC to +45oC
Product Overview
Power output (link)
Signal output
Signal input
COLORtube EQ User Manual 4 2006-07-14/09:47
Page 5
SETUP
Power
The COLORtube EQ can operate in voltages between 100V~240V 50Hz or 60Hz. It is equipped with an auto sensing transformer.
To determine the power requirements for a particular
fixture, see the label affixed to the back plate of the fixture or refer to the fixtures specifications chart.
A fixtures listed current rating is its average current
draw under normal conditions.
All fixtures must be powered directly off a switched
circuit and cannot be run off a rheostat (variable
Power Cable Configuration
CABLE (EU) CABLE (US) PIN INTERNATIONAL
BROWN
BLUE
YELLOW/GREEN
Black Live L White Neutral N
Green Earth EG (Ground)
resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch.
Before applying power to a fixture, check that the
source voltage matches the fixtures requirement.
All fixtures must be connected to circuits with a
suitable Earth Ground
Mounting
Locking plates
Flat mounting surface
Place the LED tube on a flat surface and position both mounting plates at opposite ends. Using a pencil trace out the area of the mounting plates so that you can return the plate to the same location in order to screw or affix it to the surface.
Main plate
Center plate mounting hole
Once both plates are affixed to a permanent surface, place the tube directly over the plate and assemble the remaining hardware as illustrated.
Also notice the orientation of the locking plates.
COLORtube EQ User Manual 5 2006-07-14/09:47
Page 6
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
1 2 3 4 5 6 7 8 9 31 0 0 1 1 2 2 3 3 4 4 31
method, 32 tube count
method, 6
4 tube count
OPERATING INSTRUCTIONS
The COLORtube EQ system is made up of up to 32 LED tubes whose primary function is to display a 32-band audio spectrum visualizer. The COLORtube EQ tube will operate in both Stand-Alone and Master-Slave operation.
Connection Diagram
Power
Continue chain
Standard addressing
Double-up addressing
Read about fixture addressing and settings in the sections following
Optional controller
0
COLORtube EQ
ENLARGE YOUR DISPLAY!
For a larger display double up
addresses and connect 64
tubes instead of 32.
. . . . . . . . .
. . . . . . . . .
Operation
There are 16 programs within 8 different operating modes built into the PC board on the LED tube. These programs can be initiated via the Mode dipswitches. For correct presentation of the sound spectrum it is important to address each tube in numerical order and in the manner illustrated above.
Program modes dipswitch chart
MODE PROGRAM BACKGROUND COLOR ACTIVE COLOR MODE DIPSWITCH
0
COLORtube EQ User Manual 6 2006-07-14/09:47
0 Red Green
1 Green White
2 Blue Red
3 White Red
Page 7
Introduction
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 3 2 1
ON
4 Black Red
5 Black Green
1
6 Black Pink
7 Black Yellow
8 Black Green/Red
2
3
4
5
6
7
9 Black Cyan/Red
10 Black Blue/Red
11 Black Rainbow Chase
12 Black
13 Black Dot Chase
14 Change colors Color Chase
15 Change colors Automatic
Red/Green/Cyan/
Blue Chase
COLORtube EQ User Manual 7 2006-07-14/09:47
Page 8
Introduction
OFF
ON
6 5 4 3 2 1
Fixture Addressing
1. Dipswitch 1 is reserved for setting the type of control mode on each tube.
2. Set dipswitch 1 to ON for SLAVE operation.
3. Set dipswitch 1 to OFF for MASTER or stand-alone fixture operation.
Fixture Address Fixture Address
0
6 5 4 3 2 1
16
6 5 4 3 2 1
ON
1
6 5 4 3 2 1
17
6 5 4 3 2 1
ON
2
6 5 4 3 2 1
18
6 5 4 3 2 1
ON
3
6 5 4 3 2 1
19
6 5 4 3 2 1
ON
4
6 5 4 3 2 1
20
6 5 4 3 2 1
ON
5
6 5 4 3 2 1
21
6 5 4 3 2 1
ON
6
6 5 4 3 2 1
22
6 5 4 3 2 1
ON
7
6 5 4 3 2 1
23
6 5 4 3 2 1
ON
8
6 5 4 3 2 1
24
6 5 4 3 2 1
ON
9
6 5 4 3 2 1
25
6 5 4 3 2 1
ON
10
6 5 4 3 2 1
26
6 5 4 3 2 1
ON
11
6 5 4 3 2 1
27
6 5 4 3 2 1
ON
12
6 5 4 3 2 1
28
6 5 4 3 2 1
ON
13
6 5 4 3 2 1
29
6 5 4 3 2 1
ON
14
6 5 4 3 2 1
30
6 5 4 3 2 1
ON
15
6 5 4 3 2 1
31
6 5 4 3 2 1
ON
Address
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
COLORtube EQ User Manual 8 2006-07-14/09:47
Page 9
Introduction
COLORtube EQ Controller
Power input
Power indicator led
Controller options
FUNCTION DESCRIPTION
Mode Disp User selectable built in programs in the controller
Cycle Motion
Setup
To operate with controller all tubes must be set to the SLAVE mode, (address dipswitch # 1 set to the ON position) and each fixture should be addressed in numerical order for best presentation.
Operation
1. Press the Mode button to cycle through either {Mode Disp} or {Cycle Motion}. Leave on the item you wish to select.
2. Press the Set button to enter selection.
3. Use the Up/Down buttons to toggle or change values within the selected program function. This could be either changing built it programs or changing interval time.
4. In case of {Mode Disp} option a final press of the Set button is necessary to confirm the selection.
Sound sensitivity control
Microphone: Always position facing the
sound source and at a distance, no farther than 5 meters or 16.4 feet.
Signal output
Control panel buttons:
Mode Set Up Down
All built in programs will cycle through at an interval time entered by the user between 1 and 255 minutes
COLORtube EQ User Manual 9 2006-07-14/09:47
Page 10
Introduction
Controller programs (chart)
PROGRAM DISPLAY 01
Red & Green Red Green
BACKGROUND COLOR
ACTIVE COLOR
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Green & White Green White Blue & Red Blue Red White & Red White Red Red Black Red Green Black Green Purple Black Purple Yellow Black Yellow Green & Dot Black Green w/red dot Cyan & Dot Black Cyan w/red dot Blue & Dot Black Blue w/red dot Synch Colors Black Changing solid colors Synch Dot Black Changing colors/w red dot Synch Cross Black Changing colors cross back & forth Refur Colors Changing colors Changing colors Auto Motion Black Changing colors, dots and solids
17
Black
COLORtube EQ User Manual 10 2006-07-14/09:47
Page 11
APPENDIX
Returns Procedure
Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customers responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.
Claims
Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.
Technical Specifications
WEIGHT & DIMENSIONS
.......................................................................................................................... (COLORTUBE EQ)
Length....................................................................................................................1000 mm (39.37 in)
Width............................................................................................................................50 mm (5.13 in)
Height ..........................................................................................................................95 mm (2.75 in)
Weight.........................................................................................................................1.8 Kgs (4.0 lbs)
..................................................................................................................................(CONTROLLER)
Length........................................................................................................................235 mm (9.25 in)
Width............................................................................................................................45 mm (1.77 in)
Height ..........................................................................................................................60 mm (2.36 in)
POWER
.......................................................................................................................... (COLORTUBE EQ)
Auto sensing transformer (internal)..................................................................... 90V ~ 240V 50/60 Hz
AC input (US)......................................................................................................................IEC female
Current draw................................................................................................................... (peak < 20W)
..................................................................................................................................(CONTROLLER)
Operating Voltage.................................................................................................................... 12V DC
Current draw..................................................................................................................... (peak < 2W)
ENVIRONMENT (LED TUBE)
Operating temperature..................................................................................................-20°C to +45°C
Protection rating....................................................................................................... IP33 (Interior use)
PHOTOMETRIC (LED TUBE)
Quantity of LEDs................................................................................144 (Red 48, Green 48, Blue 48)
ORDERING INFORMATION
COLORtube EQ................................................................................................................... LED-EQ
COLORtubeEQ Controller...........................................................................................LED-EQCON
Signal Cable Extension 15............................................................................................... LED-SIG15A
Signal Cable Extension 5..................................................................................................LED-SIG5A
Technical Support
Address: Service Dept. 3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.) Support (Email): tech@chauvetlighting.com Telephone: (954) 929-1115 - (Press 4) Fax: (954) 929-5560 - (Attention: Service) Website: http://www.chauvetlighting.com
COLORtube EQ User Manual 11 2006-07-14/09:47
Loading...