Channel Safety Systems HARK User Manual

Help Alarm Response Kit With battery back-up
1st Ring to be 100mm from oor. 2
nd
Ring to be between 800/1000mm from oor.
Ceiling Pull Cord 3 Core 4 Core
230v AC
PSU & Lamp/Sounder
Reset/Sounder to be 1200mm max above oor.
The Help Alarm Response Kit meets the growing requirements for a means of indicating that assistance is required.
The Help Alarm Response Kit provides a simple solution to many such environments, these include:
Disabled persons facilities
• Medical facilities
• Lone workers
Gym & spa
• Educational facilities
Equipment positioning within disabled persons facilities.
Approved Document M- ‘Access to & use of Buildings’ states the following:
…Pull cords for emergency alarms…are coloured red, located as close to a wall as possible, and have two red 50mm bangles, one set 100mm and the otherset between 800 & 1000mm above the  oor. These should be reachable from the WC. …Simple push buttons (reset unit) are notset more than 1200mm above the  oor. This should be reachable from the WC.
…The emergency assistance signal (Lamp/sounder) is located so thatit can be easily seen & heard by those able to give assistance.
Additional pull cord units can be added to the system to allow for larger rooms or multi area coverage. Please note that additional pull cords will operate & be reset by the same unit as the initial pull cord
Installation
Installation of this equipment must be carried out by a competent electrician to the requirements of the current IEE wiring regulations.
Connection details
230v AC
E L N
Power Supply incorporating
To additi onal equipment
Including
CH/HKI Multi-way
indicator
To next pull cord
Lamp/Sounder
and battery back-up
12v 0v
12v 0v X1 X2
12v 0v X1 X2
RESET
UNIT
12v 0v X1
12v 0v X1
PULL
CORD
UNIT
12v 0v X1
Use ‘intruder alarm’ type stranded cable for interlink wiring. DO NOT USE ‘TWIN & EARTH’ or other rigid cable types!
Additional options
The Help Alarm Response Kit can be linked to a remote multi-way indicator panel (for use in a reception orsta ed area). Our reference is CH/HKI/2­2 way, through to CH/HKI/11-11 way.
A 12 volt relay unit(S/E60/A) can be used to interface the unitto a wide range of equipment such as:-
• BMS
• Fire alarms
• Intruder Alarms
• Paging transmitters
1 | www.channelsafety.co.uk 0845 884 7000 @ sales@channelsafety.co.uk
Operation
Once the pull cord(s) are activated the reassurance LED on the pull cord will illuminate, the reset unit will illuminate & operate its internal sounder, and the external lamp/sounder unit will operate along with any optional equipment installed. Simply pressing the illuminated resetswitch will return the system to the ‘normal’ State.
Battery details
A23 12V AlkalineBattery
10.3mmdiameter x 28.5mmlong