Champion Pumps CP4NC Catalog

DISCHARGE 4” 125 lb., Flange Horizontal
LIQUID TEMPERATURE 104°F Continuous
MOTOR HOUSING Cast Iron, Class 30
4.5, 7.5, 11.3, 15HP
Submersible Non-Clog
VOLUTE Cast Iron, Class 30
2 vane open type with pump
IMPELLER
SOLIDS HANDLING 3” spherical
SHAFT Stainless steel
SEALPLATE Cast Iron, Class 30
SQUARE RINGS Buna-N
HARDWARE Stainless steel
PAINT Air dry enamel
SEAL
UPPER BEARING Single row, ball, oil lubricated
LOWER BEARING Double row, ball, oil lubricated
POWER CORD
out vanes on back side, Dynamically balanced, ISO G6.3, Cast Iron, Class 30
Double mechanical, Oil Filled pressure equalized reservoir, Silicon Carbide outer seal
25 Ft. Cord. Epoxy sealed housing with secondary Pressure grommet for sealing and strain relief.
www.championpump.com
MOTOR Class F Insulation, Oil Filled
Capacitor Start/Capacitor Run.
SINGLE PHASE
THREE PHASE
MOISTURE SENSOR
TEMPERATURE SENSOR
Description
Submersible non-clog sewage pump designed for typical raw sewage applications.
Champion Pump Company, Inc • P.O. Box 528 • Ashland, OH 44805
Phone 419-281-4500 • toll free 800-659-4491 • fax 419-616-1100
Requires Starter/Panel which includes capacitors and overload protection.
230/460 Volt. Dual Voltage. Requires overload protection to be included in control panel.
Normally open (N/O), requires relay in control panel
Normally closed (N/C), requires relay in control panel
CP4NC4524, CP4NC4534, CP4NC4544, CP4NC4564, CP4NC4564, CP4NC7524, CP4NC7534, CP4NC7544, CP4NC7564, CP4NC11334, CP4NC11344, CP4NC11364, CP4NC15034, CP4NC15044
1750RPM, 60Hz
4.5, 7.5, 11.3, 15HP
Submersible Non-Clog
www.championpump.com
MODEL HP Volt/PH Hz
CP4NC4524 4.5 230/1 60 1750 A 26.0 59.0 10/4 SOW 0.750 CP4NC4534 4.5 230/3 60 1750 E 18.2 56.0 10/4 SOW 0.750 CP4NC4544 4.5 460/3 60 1750 E 9.1 28.0 10/4 SOW 0.750 CP4NC4564 4.5 200/3 60 1750 C 20.9 48.6 10/4 SOW 0.750 CP4NC7524 7.5 230/1 60 1750 A 39.0 96.0 6/4 SOW 1.060 CP4NC7534 7.5 230/3 60 1750 D 26.8 80.0 8/4 SOW 0.830 CP4NC7544 7.5 460/3 60 1750 D 13.4 40.0 8/4 SOW 0.830 CP4NC7564 7.5 200/3 60 1750 B 30.8 69.5 8/4 SOW 0.830 CP4NC11334 11.3 230/3 60 1750 D 28.0 126.0 8/4 SOW 0.830 CP4NC11344 11.3 460/3 60 1750 D 14.0 63.0 8/4 SOW 0.830 CP4NC11364 11.3 200/3 60 1750 B 32.2 109.5 8/4 SOW 0.830 CP4NC15034 15 230/3 60 1750 D 38.0 160.0 6/4 SOW 1.060 CP4NC15044 15 460/3 60 1750 D 19.0 80.0 6/4 SOW 1.060
Winding resistance ± 5% at terminal block. Rated operation at ± 10% voltage at motor. Moisture/Temperature sensor cable for all models is 18/5 SOW, 0.476 inch O.D.
RPM
(Nom)
NEMA
Start Code
Full Load
Amps
Locked
Rotor Amps
Cord
Size
Cord Typ e
Cord
O.D
inch