Champion 40KPRB, PR36-40KB, FFPR26-40KB, 60KB, 60KPRB Service Manual

...
Technical Manual
Two Tank Rack Conveyor
with/without Prewash
With (FFPR26) Basic With (PR22) With (PR36) 26" Front Feed Model 22" Prewash 36" Prewash Prewash
40KB 40KPRB PR36/40KB FFPR26/40KB 60KB 60KPRB PR36/60KB FFPR26/60KB 64KB 64KPRB PR36/64KB FFPR26/64KB
June, 2005
Manual P/N 112951 Rev. I
P.O. Box 4149 2674 N. Service Road Winston-Salem, North Carolina 27115-4149 Jordan Station, Ontario,Canada L0R 1S0 336/661-1556 Fax: 336/661-1660 905/562-4195 Fax:905/562-4618
www.championindustries.com
For machines beginning with serial no. R1247 and above
Complete the information below so it will be available for quick reference.
Model Number Serial Number
Voltage and Phase
Champion Service Agency Phone
Champion Parts Source Phone
Champion Service:
Champion (USA) Champion (Canada) Phone: 1 (336) 661-1556 Phone: 1 (905) 562-4195
1 (800) 858-4477 1 (800) 263-5798
Fax: 1 (336) 661-1660 Fax: 1 (905) 562-4618
We strongly recommend that you Fax your orders.
NOTE: When calling to order parts, be sure to have the model number, serial number,
voltage and phase of your machine.
COPYRIGHT © 2004 by Champion Industries, Inc.
Machine Data Plate with Model No., Serial No., Voltage and Phase is located on the right or left side of the Control Cabinet
Top of Machine
Control Cabinet
Left to Right Model Shown
i
Revision History
Revision Revised Serial Number Comments
Date Pages Effectivity
3/10/99 All R-1247 First Issue of Manual and service replacement parts 1/26/00 35 ––– Added cradle assy P/N's 1/26/00 90 R1666 Changed motor contactor P/N 111642 to Motor
contactor P/N 108122 1/26/00 95 ––– Added dual float switch, P/N 11019 to par ts list 5/23/00 39 R-1810 Changed pump assembly parts 10/1/00 95 ––– Corrected float switch, P/N 111019 10/10/00 35 ––– Added 40-60 KB cradle part numbers 11/01/00 54 R1529 Added new piping due to change in location of
pressure switch 11/01/00 58 All Inserted new drawing for all Serial numbers with no
booster or with Steam booster 4/3/01 89 ––– Revised machines for 12' thermometer – 109499 1/03/02 55,59 R2441 Change vacuum breaker 3/4" 1044129 to 113222 1/03/02 56,60,63,73,77 Change vacuum breaker 1/4" 107069 to 113218 1/03/02 56,59,63,73,77 R2441 Change Parker/Evans 1/4" solenoid valve 109885 to
GC solenoid valve 1/2" 113352 along with repair kit,
coils and piping changes 1/03/02 73,77 Added track stiffener 325667 5/20/02 56,60,63,73,77 Added 900836 Kit* Repair, 1/4" & 1/2" Vacuum
Breaker and 900837 Kit* Repair 3/4" Vacuum Breaker 2/5/03 39 Replaced impellers with new part numbers. 2/5/03 89 Replaced 108391 with 113622 thermometer. 2/5/03 91 Replaced Furnace (Siemens) overloads with
Telemecanique (Square D) overloads. 2/5/03 92, 115, 117 Replaced P/N 111826 with P/N 111827. 7/23/03 55, 56, 59, 60, 63, Revised plastic style vacuum breakers with
73, 74, 77, 78 bronze style. 7/23/03 89 Corrected part numbers for overlays. 3/11/04 43, 45, 67, 69 R3285 Replaced 111090 with 113721 reed switch.
71, 73
3/11/04 124 ––– Revised schematic 700935 revision H to revision I.
REVISIONS
ii
REVISIONS
Revision History (Cont.)
iii
CONTENTS
CONTENTS
Page
REVISION HISTORY...................................................................................................................... i
WARRANTY .................................................................................................................................. vi
KEY COMPONENTS...................................................................................................................... 1
INTRODUCTION .......................................................................................................................... 2
GENERAL........................................................................................................................................ 3
INSTALLATION ............................................................................................................................ 5
Unpacking .......................................................................................................................... 5
Electrical Connections ........................................................................................................ 5
Plumbing Connections ........................................................................................................ 6
Ventilation Connections ...................................................................................................... 6
Chemical Connections ........................................................................................................ 6
Curtain Locations ................................................................................................................ 7
Completing Installation ...................................................................................................... 7
OPERATION.................................................................................................................................... 8
MAINTENANCE ............................................................................................................................ 11
Maintenance Schedule ........................................................................................................ 11
Deliming.............................................................................................................................. 12
TROUBLESHOOTING .................................................................................................................. 13
ELECTRICAL SERVICE ................................................................................................................ 15
MECHANICAL SERVICE ..............................................................................................................23
TABLE LIMIT SWITCH INSTALLATION.................................................................................... 27
REPLACEMENT PARTS ................................................................................................................ 31
ELECTRICAL SCHEMATICS ...................................................................................................... 111
LIST OF FIGURES
Figure 1 — Fuse Blocks .............................................................................................................. 15
Figure 2 — Motor Overload ...................................................................................................... 15
Figure 3 — Pump Timer ..............................................................................................................16
Figure 4 — Dual Float Switch .................................................................................................... 17
Figure 5 — Tank Heat Ther mostats ............................................................................................ 18
Figure 6 — Booster Thermostat Locations (Electric) ................................................................ 18
Figure 7 — Booster High Limit Thermostat (Electric) .............................................................. 18
Figure 8 — Front View Typical 40°F/22°C rise Booster, One Tank 36 Kw shown .................. 22
Figure 9 — F ront View Typical 70°F/39°C rise Booster, Two Tank 57 Kw shown .................... 22
Figure 10 — Idle Pump Switch Assembly .................................................................................... 24
iv
REVISIONS
LIST OF FIGURES (Cont.)
Figure 11 — Magnetic Switch and Magnet .................................................................................. 24
Figure 12 — Rinse-Saver Switch Mechanism .............................................................................. 24
Figure 13 — Crank Assembl y........................................................................................................ 25
Figure 14 — Conveyor Drive Assembly........................................................................................ 25
Figure 15 — View of Load End of Machine ................................................................................ 26
Figure 16 — Close-up View of Bearing Housing ........................................................................ 26
Figure 17 — Close-up View of Clutch Assembly .......................................................................... 26
Figure 18 — Conveyor Drive Assembly........................................................................................ 32
Figure 19 — Track and Cradle Assembly .................................................................................... 34
Figure 20 — Track and Cradle Assembly-PR22, PR36 ................................................................ 36
Figure 21 — Motor and Pump Assembly (Wash, Power Rinse, Prewash) .................................... 38
Figure 22 — Idle Pump Mechanism ............................................................................................ 42
Figure 23 — Idle Pump Switch (FFPR26 Only) (All S/N’s) ........................................................ 44
Figure 24 — Wash System Assembly (Wash Tank and Power Rinse Tank).................................. 46
Figure 25 — Wash System Assembly (PR22, FFPR26)................................................................ 48
Figure 26 — Wash System Assembly (PR36) .............................................................................. 50
Figure 27 — Outside Rinse Piping with Electric Booster ............................................................ 52
Figure 28 — Outside Rinse Piping with Electric Booster After R1529 ...................................... 54
Figure 29 — Fill and Outside Rinse Piping, w/No Booster and Steam w/Booster ...................... 58
Figure 30 — Cold Water Thermostat for Prewash Option .......................................................... 62
Figure 31 — Inside Rinse Piping .................................................................................................. 64
Figure 32 — Rinse Saver Mechanism (L-R) ................................................................................ 66
Figure 33 — Rinse Saver Mechanism (R-L) .............................................................................. 68
Figure 34 — Doors, Curtains, Miscellaneous................................................................................ 70
Figure 35 — Hood (PR22, PR36) ................................................................................................ 72
Figure 36 — Hood (FFPR26) ...................................................................................................... 76
Figure 37 — Tank (PR22).............................................................................................................. 80
Figure 38 — Tank (PR36) ............................................................................................................ 82
Figure 39 — Tank (FFPR26) ...................................................................................................... 84
Figure 40 — Drain Unit and Screens Wash/Power Rinse Tank .................................................... 86
Figure 41 — Control Cabinet ........................................................................................................88
Figure 42 — Control Panel............................................................................................................ 90
Figure 43 — Tank Heat (Electric, R-L Shown) ............................................................................ 94
Figure 44 — Tank Heat (Steam Coils, R-L Shown) ...................................................................... 96
Figure 45 — Tank Heat (Steam Supply Piping)............................................................................ 98
Figure 46 — Tank Heat (Condensate Piping)................................................................................ 100
Figure 47 — Tank Heat (Steam Injector, R-L Shown) .................................................................. 102
Figure 48 — Electric Booster (40°F/22°C Rise) .......................................................................... 104
Figure 49 — Electric Booster (70°F/39°C Rise) .......................................................................... 106
Figure 50 — K2 Steam Booster .................................................................................................... 108
v
CONTENTS
Figure 51 — Thrush Steam Booster (40°F/22°C - 70°F/39°C Rise) ............................................ 110
Figure 52 — Thrush Steam Booster (80°F/44°C Rise) ................................................................ 112
Figure 53 — Control Panel, Electric Booster (70°F/39°C Rise) .................................................. 114
Figure 54 — Control Panel, Electric Booster (40°F/22°C Rise) .................................................. 116
Figure 55 — Vent Hood Assembly ................................................................................................ 118
Figure 56 — Dish Racks................................................................................................................ 120
ELECTRICAL SCHEMATICS
B700935/I — Wiring Diagram (64KB, 40KB, 60KB Steam/Electric) B700936/G— Wiring Diagram (64KPRB, 40KPRB, 60KPRB Steam/Electric)
vi
REVISIONS
LIMITED W ARRANTY
Champion Industries Inc. (herein referred to as Champion), P.O. Box 4149, Winston-Salem, North Carolina 27115, and P.O. Box 301, 2674 N. Service Road, Jordan Station, Canada, L0R 1S0, warrants machines, and par ts, as set out below.
Warranty of Machines: Champion warrants all new machines of its manufacture bearing the name “Champion”
and installed within the United States and Canada to be free from defects in material and workmanship for a period of one (1) year after the date of installation or fifteen (15) months after the date of shipment by Champion, whichever occurs first. [See below for special provisions relating to glasswashers.] The warranty registration card must be returned to Champion within ten (10) days after installation. If warranty card is not returned to Champion within such period, the warranty will expire after one year from the date of shipment.
Champion will not assume any responsibility for extra costs for installation in any area where there are jurisdictional problems with local trades or unions.
If a defect in workmanship or material is found to exist within the war ranty period, Champion, at its election, will either repair or replace the defective machine or accept return of the machine for full credit; provided, however, as to glass­washers, Champion’s obligation with respect to labor associated with any repairs shall end (a) 120 days after shipment, or (b) 90 days after installation, whichever occurs first. In the event that Champion elects to repair, the labor and work to be performed in connection with the warranty shall be done during regular working hours by a Champion authorized service technician. Defective parts become the property of Champion. Use of replacement parts not authorized by Champion will relieve Champion of all further liability in connection with its warranty. In no event will Champion’s warranty obligation exceed Champion’s charge for the machine. The following are not covered by Champion’s warranty:
a. Lighting of gas pilots or burners. b. Cleaning of gas lines. c. Replacement of fuses or resetting of overload breakers. d. Adjustment of thermostats. e. Adjustment of clutches. f. Opening or closing of utility supply valves or switching of electrical supply current. g. Cleaning of valves, strainers, screens, nozzles, or spray pipes. h. Performance of regular maintenance and cleaning as outlined in operator’s guide. i. Damages resulting from water conditions, accidents, alterations, improper use, abuse,
tampering, improper installation, or failure to follow maintenance and operation procedures.
j. Wear on Pulper cutter blocks, pulse vanes, and auger brush. Examples of the defects not covered by warranty include, but are not limited to: (1) Damage to the exterior or interior
finish as a result of the above. (2) Use with utility service other than that designated on the rating plate. (3) Improper connection to utility service. (4) Inadequate or excessive water pressure. (5) Corrosion from chemicals dispensed in excess of recommended concentrations. (6) Failure of electrical components due to connection of chemical dispensing equipment installed by others. (7) Leaks or damage resulting from such leaks caused by the installer, including those at machine table connections or by connection of chemical dispensing equipment installed by others. (8) Failure to comply with local building codes. (9) Damage caused by labor dispute.
Warranty of Parts: Champion warrants all new machine parts produced or authorized by Champion to be free
from defects in material and workmanship for a period of 90 days from date of invoice. If any defect in material and workmanship is found to exist within the war ranty period Champion will replace the defective part without charge.
DISCLAIMER OF
WARRANTIES AND LIMITATIONS OF LIABILITY. CHAMPION’S WARRANTY IS ONLY TO THE EXTENT REFLECTED ABOVE. CHAMPION MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED,TO ANY WARRANTY OF MERCHANTABILITY, OR FITNESS OF PURPOSE. CHAMPION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. THE REMEDIES SET OUT ABOVE ARE THE EXCLUSIVE REMEDIES FOR ANY DEFECTS FOUND TO EXIST IN CHAMPION DISHWASHING MACHINES AND CHAMPION PARTS, AND ALL OTHER REMEDIES ARE EXCLUDED, INCLUDING ANY LIABILITY FOR INCIDENTALS OR CONSEQUENTIAL DAMAGES.
Champion does not authorize any other person, including persons who deal in Champion dishwashing machines to change this warranty or create any other obligation in connection with Champion Dishwashing Machines.
1
Vacuum Breaker
Line Strainer
Power Rinse Tank Heat Control and High Limit
Thermostats Power Rinse tank Pump/Motor Assembly
Dual Float Switch Auto Fill/Low Water Tank Heat Protection
Door-activated Drain-overflow Tube Assembly
Final Rinse-Saver Mechanism (Switch and Magnet)
Final Rinse Booster Tank Assy
(Electric Only)
Power Rinse Tank Heater Element
Final Rinse Piping
Pushbutton Stop Switch (Red)
Wash Spray Arms
Pushbutton Start Switch (Green)
Main Power Switch/ Circuit Breaker
Control Transformer
Solenoid Valve
Pressure Gauge
Pressure Reducing Valve, PRV,
(Factory installed on machines with boosters)
Top Mounted Control Cabinet
Temperature Gauges
Conveyor Crank and Crosshead Roller Assembly
Conveyor Dr ive Clutch and Gear Reducer
Cradle Assembly
Idle Pump Mechanism (Switch and Magnet)
Rack Conveyor Key Component Locations
(Right to Left Electrical Machine Shown)
KEY COMPONENTS
2
INTRODUCTION
INTRODUCTION
Welcome to Champion.
...and thank you for allowing us to take care of your dishwashing needs. This manual covers several models. Model numbers are shown on the front cover. Your machine has been completely assembled, inspected, and thoroughly tested at our factory
before it was shipped to your installation site. This manual contains:
• Warranty information
• Operation and cleaning instr uctions
• Maintenance instr uctions
• Troubleshooting guide
• Basic ser vice infor mation
• Replacement par ts lists
• Electrical schematics
Complete and return your warranty registration card within ten (10) days after the installation of your machine.
All information, illustrations and specif ications contained in this manual are based upon the lat­est product information available at the time of publication. Champion constantly improves its products and reserves the right to make changes at any time or to change specifications or design without notice and without incurring obligation.
For your protection, factor y authorized par ts should always be used for repairs. Replacement parts may be ordered from your Champion authorized service agency. When
ordering parts, please supply the model number, serial number, voltage and phase of your machine, the part number, part description, and quantity.
3
GENERAL
GENERAL
This manual covers the Champion two tank rack conveyor dishwashing machine. This machine is fully automatic and is equipped with 2 H.P. wash/rinse pump motors and a 1/4 H.P. conveyor drive motor. All models are available for right-to-left or left-to-right operation.
This series of dishwashers is modular in design. The following models and options are covered in this manual:
Model Numbers
Two tank - Basic.................................................... 64KB, 40KB, 60KB
Two tank with 22" Prewash .................................. 64KPRB, 40KPRB, 60KPRB
Two tank with 36" Prewash .................................. PR36/64KB, PR36/40KB, PR36/60KB
Two tank with 26" Front Feed Prewash ................ FFPR26/64KB, FFPR26/40KB, FFPR26/60KB
• The 64KB basic model, along with its respective prewash option, is a high temperature (180˚F/82°C final rinse) sanitizing model.
• The 40KB basic model, along with its respective prewash option, is a high temperature (180˚F/82°C final rinse) sanitizing model.
• The 60KB basic model, along with its respective prewash option, is a high temperature (180˚F/82°C final rinse) sanitizing model.
4
THIS PAGE
INTENTIONALLY
LEFT BLANK
GENERAL
5
INSTALLATION
Unpacking
CAUTION:
Care should be taken when lifting the machine. The piping under the base can be damaged. Remove the dishwasher front panels if lifting from the front with a forklift.
1. Immediately after unpacking your machine, inspect for any shipping damage. If damage is found, save the packing material and contact the carrier upon receipt of the machine.
2. Remove the dishwasher from the skids. Adjust the feet if required, then move the machine to its permanent location. The machine should not be installed within 6 inches [153mm] of any wall or structure.
3. Level the machine by placing a level on the top of the machine and adjusting the feet. Level front-to-back and side-to-side.
Electrical Connections
NOTE:
Electrical and grounding connections must comply with the National Electrical Code and/or Local Electrical Codes.
WARNING:
When working on the dishwasher, disconnect the electric service and tag it to indicate work is being done on that circuit.
1. The electrician should compare the electrical specifications on the machine electrical con­nection plate (located inside the control cabinet) to the electrical power supply before con­necting to the incoming service at a fused disconnect switch.
2. Motor rotation was set at the factory. Ensure proper rotation of the conveyor drive shaft (red arrow on shaft shows direction of rotation). Reversing the motor direction is done in the con­trol cabinet by reversing the wires Ll and L2 on the disconnect switch side of the main elec­trical connection terminal block (Refer to the electrical diagrams in the back of this manual).
3. A knock-out plug is provided at the rear of the control cabinet for electrical service connec­tions.
NOTE:
Electrical and grounding connections must comply with the National Electrical Code and/or Local Electrical Codes.
NOTE:
Electric boosters require a separate electrical connection.
A fused disconnect switch or circuit breaker (supplied by user) is required to protect each
INSTALLATION
!
!
6
Chemical Connection
Terminal Board
INSTALLATION
Plumbing Connections
CAUTION:
Plumbing connections must comply with local sanitary and plumbing codes.
1. Connect the hot water supply at the final rinse piping connection located behind the control cabinet at the top of the machine.
2. A “Y” line strainer is provided by Champion for machines without boosters. A pressure reducing valve (PRV) is provided by Champion for machines with built-in boosters.
3. If the incoming hot water supply pressure exceeds 25 psi [173 kPa], a PRV must be installed and set to 20-22 psi [138-151 kPa]. The PRV may be purchased from Champion or supplied by others.
4. Install a manual shut-off valve in the steam and water supply lines to accommodate ser vicing the machine. The valve should be the same size as or larger than the supply line.
5. Provide a suitable gravity drain to connect to a 1-5/8" OD drain tube.
Ventilation
1. Stainless steel watertight ducting should be installed INSIDE the 4" x 16" [102mm x 407mm] vent stacks at the load and unload ends. A minimum of 6 air changes per hour of kitchen air is recommended. The typical exhaust ventilation requirements for a rack machine using a 180˚F/82°C final rinse are:
• The load end requires 150 CFM @ 1/4" (SP), [71 Liters/sec] with prewash.
• The load end requires 200 CFM @ 1/4" (SP), [95 Liters/sec] without prewash.
• The unload end requires 400 CFM @ 1/4" (SP), [189 Liters/sec].
2. An adjustable damper is supplied with the vent stacks for adjusting the exhaust volume.
CAUTION:
Exhaust air should not be vented into a wall, ceiling, or concealed space of a building. Condensation will cause damage.
Chemical Connections
1. Use a qualified detergent/chemical supplier.
2. Labeled control circuit connection ter minals are provided in the control cabinet for detergent and rinse agent/sanitizer dispensing equipment (supplied by others).
3. Refer to the illustration below. The illustration shows the ter­minal board for current production machines. Signal connection points include:
• Detergent signal 120VAC, 1 Amp Max amp load.
• Rinse aid/Sanitizer signal 120VAC, 1 Amp Max amp load.
4. A removable black plug is provided in the load end side of the wash tank for installation of the detergent conductivity cell.
!
!
SIGNAL ONLY
120V
120V
RINSE AID/ SANI
COMMON
DETERGENT
1R001
7
Short cur tain
Long curtain
Load End
Curtain Locations
(Machine with prewash shown)
Long curtain
Short
flaps
Short flaps on long curtains
face the load end of dishwasher
Curtain Locations
1. Refer to the illustrations below and hang the curtains as shown. J-hooks are located in the corners of each section to accept the curtain rods.
• Standard long curtain 24" x 20-1/4" [610mm x 515mm]
• High hood long curtain 24" x 22-3/4" [610mm x 578mm]
• Standard short curtain 24" x 13-1/4" [610mm x 337mm]
• High hood short curtain 24" x 20-1/4" [610mm x 515mm]
2. Make sure the short flaps of the long cur tains f ace the load end of the dishwasher. The longest curtains always go on each end of the dishwasher.
INSTALLATION
Completing Installation
WARNING:
Do not insert racks into machine before tanks fill with water. Operating pumps dry will cause pump seal damage and leakage that can result in a motor failure.
1. Remove any foreign material from inside the machine.
2. Check to insure that drains and overflow pipes are operational and sealed.
3. Position scrap screens on supports above the tanks.
4. After plumbing and electrical connections are completed, fill the tank and wait 10 minutes. Check all plumbing connections for leaks.
5. Drain the tank and check the drain lines for leaks.
6. The for med down lip of the dishtable should be placed inside the machine. The dishtable should be pitched toward the dishwasher for proper draining by adjusting its leveling feet. The dishtable should be sealed to the dishwasher.
!
1R003
WASH
PRE
WASH
R-L Direction
Power Rinse
1R002a
8
Simplified Rack Conveyor Dishwasher
Right to Left Model
OPERATION PROCEDURE
OPERATION
Final Rinse Water
Wash Water
Temperature Gauge
Temperature Gauge
Vacuum
Breaker
Long Curtain
Idle Pump
Magnet
Idle Pump
Magnetic Switch
Conveyor Crank
Conveyor Drive
Motor and Gear
Clutch
Assembly
Reducer
Control Cabinet
Green Start Button
Lighted On-Off
Rocker Switch
Pressure
Regulating
Rinse Valve
Red Stop Button
Vacuum
Breaker
Fill Valve
Valve
Wash Arm Spray Pipes
Right to Left Model
Conveyor Direction
Wash Arm Spray Pipes
Booster
E lectric Tank
Heaters
Pump
Strainer
Wash
Pump
Dual Float
Switch
Short Curtain
Rinse-Saver
Final Rinse
Drain-off
Adjustment
Magnet
Rinse-Saver
Magnetic Switch
Door Activated
Drain-overflow
Assembly
Long Curtain
Upper Final Rinse Pipe
Lower Final Rinse Pipe
9
OPERATION
Rack Conveyor Machine
Operation Procedure
Action Result
Turn Power Switch on
Press green start button
Insert soiled rack
Rack conveys thru machine
Rack activates final rinse
Rack exits the machine
Press stop push button
Drain machine for cleaning
after each meal period
or every 2 hours of use
Lighted On-Off Rocker Switch
on control cabinet will illuminate
Float switch activated
Tank(s) fill with water
When machine is full float
switch cuts off water
and calls for heat.
(Wait for proper temperature)
Conveyor drive motor
is activated
Wash pump starts
Continuous power on wire #13
and #2 120V Detergent signal
20 psi required flow pressure
Power to wire #70 and #2 120V
Rinse/Sanitize signal
Wash pumps shut down (timer)
Conveyor continues to run
Conveyor drive will stop
Check detergent and rinse aid
supply. Replenish if necessary
Doors are closed
Door activated drains
are closed
10
OPERATION
OPERATION
Follow the procedure below to operate your dishwasher properly.
1. Check that spray pipes, curtains, overflow drains, and scrap screens are in place and clean.
2. Turn on detergent dispenser switches and check detergent supply.
3. Turn on exhaust vent system (if applicable), and make sure it is operating.
4. Close door(s). Push the power switch to the ON position. Tanks will begin filling with water.
5. When tanks are full, check wash tank temperature gauge. Minimum wash temperatures are:
• 64KB, 40KB, 60KB Wash tank - 150°F/66°C
• 64KB, 40KB, 60KB Power rinse tank - 160°F/71°C
• Prewash tanks do not have tank heaters
6. Press the START button on the control cabinet. Only the conveyor will start. The pumps WILL NOT OPERATE until the first rack enters the machine.
7. Scrap and pre-flush all items to be washed, and load the items into the rack. DO NOT OVERLOAD RACKS. Place dishes edgewise in a peg rack, cups and bowls upside down in a flat rack. Spread silverware evenly in a single layer in a flat rack or upright (loosely packed) in a cutlery rack.
8. Push the rack into the machine, and the pumps will star t automatically.
9. Check the rinse pressure and temperature as the racks pass through the final rinse. This rinse pressure MUST be 20-22 psi [138-151 kPa] and the f inal rinse temperature MUST be 180°F/82°C minimum.
10. The pumps will automatically stop shortly after the last rack leaves the machine. The conveyor will continue to run.
11. The machine may be stopped any time during the cycle by pressing the STOP button on the control cabinet. When restarted, items inside the machine will be fully washed and rinsed.
12. CLEAN scrap screens, scrap baskets (if applicable) and REPLACE tank water every 2 hours of operation or after each meal period. Check chemical supply.
CAUTION:
DO NOT allow racks to remain on unload dishtable. This could cause the conveyor to jam and may damage machine. The installation of a table limit switch is highly recommended and will reduce the risk of damage.
WARNING:
Do not leave water in tanks overnight.
!
!
11
MAINTENANCE
MAINTENANCE
The efficiency and life of your machine is increased by regularly scheduled preventive maintenance. A well maintained machine gives better results and ser vice. An investment of a few minutes of daily maintenance will be worthwhile.
The best maintenance you can provide is to keep your machine clean. Components that are not regularly cleaned and flushed will clog and become inoperative.
Intervals shown in the following schedules represent an average length of time between necessary maintenance. Maintenance intervals should be shortened whenever your machine is f aced with abnormal working conditions, hard water, or multiple shift operations.
Maintenance Schedule CLEANING
• Daily-Every 2 Hours of Operation
1. Turn power switch to OFF.
2. Remove all scrap screens, scrap baskets (if applicable), and pull drain lever(s) to drain water. Clean inside of tanks and flush with clean water. Backflush scrap screens until clean.
Do not strike screens against solid objects.
3. Remove the spray pipes by a 1/4 tur n, counterclockwise. Remove the end plug from each spray pipe. Flush pipe and nozzles until clean. Do not strike spray pipes against solid objects. Replace end plugs, verify that rubber seals are in place on manifolds. Reinstall spray pipes using a 1/4 clockwise turn.
4. Remove and clean curtains. Hang them off the dishtable to dry.
5. Leave the doors open between operations to allow dr ying.
6. Verify that final rinse nozzles are clean and free of inter nal hard water deposits. Clean rinse nozzle orifices with a small paper clip. Consult your chemical supplier for the proper use and kind of deliming chemical.
7. Repor t any unusual conditions to your supervisor.
• As Required
1. Check temperature and pressure gauge readings.
2. Inspect machine and check pump motor for leaks around the shaft.
3. Check chemical supplies and refill as necessar y.
• Weekly
1. Inspect all water lines for leaks and tighten at joints if required.
2. Clean all detergent residue from exterior of machine.
3. Check drain/overflow tube for leaks.
4. Clean accumulated scale from heating element.
5. Remove and closely inspect each spray ar m for blockage.
12
MAINTENANCE
• Weekly (Cont.)
6. Straighten a paper clip and use it to clear each rinse nozzle.
7. Inspect pawl bars and drive assembly for wear and freedom of travel.
8. Check float switches in tank for freedom of travel.
9. Check idle pump and final rinse levers for freedom of travel.
DELIMING
Your dishwasher should be delimed regularly as required. This will depend on the mineral con­tent of your water.
Inspect your machine interior for lime deposits. If deliming is required, a deliming agent should be used for best results. Consult your chemical supplier for proper type and procedures.
DANGER:
Deliming solution, rinse agents, or other acids must not come in contact with house­hold bleach (sodium hypochlorite) or any chemicals containing chlorine, iodine, bromine, or fluorine. Mixing may cause hazardous gases to form. Consult your chemical supplier.
!
13
TROUBLESHOOTING
In order to find the cause of a breakdown or abnormal operating condition in your dishwasher please ensure that:
1. All switches are ON
2. Drain and overflow tube are in place and seated
3. Wash pipe and rinse nozzles are clean
4. Scrap screen(s) and scrap basket (if applicable) are properly positioned
5. Spray pipes are in their proper positions
6. Ther mostat(s) are at their cor rect setting
7. Sanitizer, detergent, and rinse additive dispensers are adequately filled
8. Doors are fully closed.
If a problem still exists, use the following table for troubleshooting
CONDITION CAUSE SOLUTION
Machine will not start Door not closed .................................. Make sure doors are fully closed
Door safety switch faulty .................. Contact your service agency
Start switch faulty.............................. Contact your ser vice agency
Main switch off.................................. Check disconnect
No rack inserted ................................ Place rack in unit
Overload protector tripped ................ Reset overload in control box
Low or no water Main water supply is turned off ........ Turn on house water supply
Drain/overflow tube is not
in place and seated ............................ Place and seat drain tube
Machine doors not fully closed ........ Close doors securely
Faulty fill valve.................................. Contact your service agency
Stuck or defective float...................... Check floats and clean
Clogged ‘Y’strainer .......................... Clean or replace
Continuous water filling Stuck or defective float...................... Check floats and clean
Fill valve will not close...................... Clean or replace
Drain tube not in place ...................... Look for drain tube in tank
Any motor not running Overload protector tripped ................ Reset overload in control box
Defective motor ................................ Contact your service agency
Wash tank water temperature Incoming water temperature
is low when in use at machine too low ............................ Raise temperature to: 140°F/60°C
Defective thermometer ...................... Check or replace
Defective thermostat.......................... Check for proper setting or replace
Defective heater element .................. Check or replace
Low steam pressure .......................... Check steam supply pressure
Defective steam trap.......................... Check or replace
Defective solenoid valve.................... Check or replace
TROUBLESHOOTING
14
CONDITION CAUSE SOLUTION
Insufficient pumped spray Clogged pump intake screen.............. Clean
pressure Clogged spray pipe............................ Clean
Scrap screen full ................................ Must be kept clean and in place
Low water level in tank...................... Check drain and overflow tube
Pump motor rotation incorrect .......... Reverse connection between L1
and L2 in control cabinet (3 phase only)
Defective pump seal .......................... Contact service agent
Insufficient f inal rinse or no Faulty pressure reducing valve .......... Clean or replace
final rinse Improper setting on pressure
reducing valve.................................... Set flow pressure to 20-22 psi [138-151 kPa]
Clogged rinse nozzle and/or
pipe .................................................... Clean with paper clip/delime
Improper water line size.................... Have installer change to proper size
Clogged ‘Y’strainer .......................... Clean or replace
Low final rinse temperature Low incoming water ........................ Check the booster (KB, KPRB models)
be sure the thermostat is set to maintain 180°F/82°C temperature. Check valve to be sure it is clean and operating.
Defective thermometer ...................... Check for proper setting or replace
Poor washing results Detergent dispenser not
operating properly.............................. Contact detergent supplier
Insufficient detergents ...................... Contact detergent supplier
Food Soil concentration too
high in wash tank .............................. Drain tank, clean and refill every 2 hours of
operation or after each meal period. Wash water temperature
too low .............................................. See condition “Wash Tank
W ater Temperature” above
Wash ar m clogged .............................. Clean
Improperly scraped dishes ................ Check scraping procedures
Ware improperly
placed in rack .................................... Use proper racks. Do not overload racks
Improperly cleaned
equipment .......................................... Unclog wash sprays and rinse nozzles
to maintain proper pressure and flow
conditions. Overflows must be open.
Keep wash water as clean as possible. Electric elements or steam
coils has soil/lime buildup ................ Clean and delime
TROUBLESHOOTING
15
1R005
1R004
Figure 1
Fuse Blocks
Figure 2
Motor Overload
ELECTRICAL SERVICE
ELECTRICAL SERVICE
Fuse Blocks—120VAC Control Voltage
Two fuse blocks, located in the center rear of the main control cabinet protect the main control transformer. Each fuse block holds a fuse. The fuses are marked 1FU and 2FU on the electrical schematic.
To Replace the fuse:
• Disconnect power to the machine at the main service switch.
• Flip the tab on the top of the fuse block to open the block.
• Remove the fuse and replace it.
• Close the fuse block and turn the main power on.
• If the fuse blows again, DO NOT INCREASE THE FUSE SIZE.
• DETERMINE THE CAUSE OF THE OVERLOAD. Fig. 1 shows the fuse block opened and the fuse exposed.
Motor Overloads
Motor overloads are located to the left of the fuse blocks inside the control cabinet. Each motor has one overload to protect it from line voltage electrical overloads. In addition, an auxilary set of switch contacts is built into the overload. The switch contacts disconnect 120VAC power to the motor contactor coils in the event of an overload condition. Refer to Fig. 2.
Note the Switch Lever on the Overload.
If the switch lever is off with the “0” showing
then the overload has tripped on an overload.
To Reset the Motor Overload:
Flip the star ter switch to the On position.
• Run the dishwasher and test the AMP draw of the motor in question. If the motor checks okay then there may be a wiring problem or the overload may be defective.
To Replace a Motor Overload:
Disconnect the wires to the overload.
• Release the mounting catch on the front side of the overload, push forward and lift out.
• Snap the new overload into place and reconnect the wires.
To adjust the overload setting:
The screwdriver in Fig. 2 is positioned to adjust the motor overload AMP setting.
• Read the FLA motor amps that applies for the machine voltage on the Motor Nameplate.
• Turn the setting to match nameplate FLA.
16
BackFront
Pump Timer
Refer to Fig. 3 The automatic timer located in the left center of the control cabinet is set at the factory.
The Pump Timer controls the amount of time that the pumps will run before the last rack enters the load end of the dishwasher tunnel.
The Pump Timer is an OFF DELAY timer. Each timer is marked
with a tag noting the time set by the factory.
The timer has the following user defined settings:
1. Adjustable timer range
2. Timer knob setting
3. Indicator light (ON when timer is counting)
4. 50 Hz or 60 Hz setting on the back of the timer
To Replace a Timer:
Disconnect power to the machine at the main service switch.
• Remove the defective timer and install the replacement.
• Adjust the new timer setting to match the setting of the original timer.
Operation Sequence:
A dishrack entering the machine contacts the idle pump switch lever.
• Nor mally closed contacts of the idle pump switch open, de-energizing control relay 1CR.
• Nor mally closed contacts (1, 9) of 1CR close and apply 120VAC to reset coil of pump timer.
• Pump timer resets.
• The dishrack moves off the idle pump switch lever. The switch contacts close.
• 1CR energizes and contacts (1, 9) open removing 120VAC from the pump timer reset coil.
• The pump timer begins to time down for its preset time setting.
• The timer is reset each time the idle pump switch is activated. If the timer is reset only once it will time out and shut the pumps off after the rack has exited the dishwasher.
To Check the Pump Timer Setting:
• Turn the power on.
• Place a rack on the conveyor.
• Press the Green star t button. The conveyor drive will start.
• When the rack enters the load end the pumps will star t.
• Wait for the rack to exit the tunnel at the unload end.
• When the pumps stop, push the red stop button.
• Measure the distance between the exit end of the tunnel and the rack.
• The rack should be about 1 foot past the end of the tunnel.
• If the distance is less than 1 foot, increase the pump timer setting. Continue to increase the timer setting a few seconds at a time until the proper distance is reached.
• If the measured distance is g reater than 1 foot, decrease the pump timer setting. Continue to decrease the timer setting a few seconds at a time until the proper distance is reached.
ELECTRICAL SERVICE
0
1
2
3
UP
4
5
6 Omron H2C
6M
1R006
50
60
1
2
3
4
5
6
7
8
1R007
Figure 3
Pump Timer
17
1R008
Figure 4
Dual Float
Switch
ELECTRICAL SERVICE (Cont.)
Automatic Fill/Low Water Heat Protection
Dual Float Switches –
Refer to F
ig. 4 Each tank contains a dual float. The device consists of an angled stem containing two reed switches. Two stainless steel ball floats slide over the stem and are free to move up and down. The floats contain magnets. When the float moves on the stem, it opens and closes its associated reed switch inside the stem. The reed switches control relays. The relays control the automatic fill and heat for different parts of the machine. Float switches and their relays operate on 24VAC.
Circuit Explanation –
The following is a general explanation of the float switch circuit. Refer to the electrical schematic on your machine for a detailed description of the individual floats, relays, and wiring.
Bottom Float and Reed Switch:
The bottom float controls the heat.
• When the bottom float is down, the bottom reed switch contacts are open.
• When the bottom float is up, the bottom reed switch contacts close.
Top Float and Reed Switch:
The top float controls a fill valve.
• When the top float is down, the top reed switch contacts are open.
• When the top float is up, the top reed switch contacts are closed.
Initial Fill –
• When the tank is completely empty, both floats are down and their reed switch contacts are open.
• The control relay for the float switch is de-energized.
• The fill valve for the tank is energized and the tank begins to fill with water.
• As the water level in the tank rises, the bottom float begins to move up.
• When the bottom float is completely up, its NO reed switch contacts close.
• This prepares the heat circuit, but the heat Does Not energize at this time.
• The tank continues to fill until the top float is completely up.
• The top float’s NO reed switch contacts close. Its control relay energizes.
• The fill valve de-energizes.
• The heat circuit energizes through the float switch and the contacts of the control relay.
During Normal Operation –
If the water level in a tank falls below the level of the top float, the top float moves down and
its reed switch contacts open.
• When the water level falls below the level of the bottom float, the bottom float moves down
and its reed switch opens.
• The control relay de-energizes. The fill valve energizes and refills the tank.
• The heat circuit will de-energize until the water level in the tank raises the top float again.
• The bottom float keeps the heat circuit ready as long as the water level is above the level of
the bottom float.
ELECTRICAL SERVICE
18
1R010
1R009
Figure 5
Tank Heat Thermostats
Figure 6
Booster Thermostat Locations
Figure 7
Booster – High Limit Thermostat
ELECTRICAL SERVICE
ELECTRICAL SERVICE (Cont.)
Thermostat Locations and Adjustments
Refer to Fig. 5 Electric tank heat is controlled by two ther mostats.
1. The control ther mostat which regulates the temperature.
2. The high limit ther mostat which protects from overheating.
Location:
Both thermostats are located on front of tank, inside a black enclosure box behind the front access panel.
Adjustment:
The Control Thermostat has an adjustment screw on one side.
• The ther mostat is wired Nor mally Closed.
• Turn the adjustment screw clockwise to increase the temperature in the tank and counterclockwise to decrease the temperature in the tank.
The High Limit Thermostat is not adjustable. It contains a red reset button in its center.
• The red button pops out if the temperature in the tank exceeds 210°F/99°C.
• Press the red button in to reset the high limit. Determine the cause of the high temperature condition.
Refer to F
ig. 6 and Fig. 7.
Electric Booster Heat is controlled by two ther mostats.
1. The control ther mostat which regulates the temperature.
2. The high limit ther mostat which protects from overheating.
3. Each tank has a control and a high limit ther mostat.
Location:
The control thermostat is enclosed in a black box mounted on the front of the wash tank behind the front access panel. The high limit thermostat is enclosed in a box mounted on top of the booster tank.
Adjustment:
The control thermostat has an adjustment screw on one side.
• The ther mostat is wired Nor mally Closed.
• Turn the adjustment screw clockwise to increase the booster tank temperature and counterclockwise to decrease the booster tank temperature.
The high limit thermostat is a bimetal snap design. It is not adjustable.
• A button with a red dot in the center pops out when the temperature exceeds 210°F/99°C.
• Press the red reset button in to reset the high limit. Determine the cause of the high temperature condition.
Control Thermostat
High limit Thermostat
High Limit Thermostat
Control Thermostat
1R011
19
480V/3 Phase
575V/3 Phase
Delta Connection
480V/3 Phase
575V/3 Phase
Delta Connection
480V/3 Phase
575V/3 Phase
Delta Connection
480V/3 Phase
575V/3 Phase
Delta Connection
208-240V/3 Phase
Wye Connection for
380-415V/3 Phase
208-240V/3 Phase
Wye Connection for
380-415V/3 Phase
208-240V/3 Phase
Wye Connection for
380-415V/3 Phase
208-240V/3 Phase
Wye Connection for
380-415V/3 Phase
208-240V/3 Phase
Delta Connection
208-240V/3 Phase
Delta Connection
208-240V/3 Phase
Delta Connection
208-240V/3 Phase
Delta Connection
208V/1 Phase
208V/1 Phase
208V/1 Phase
208V/1 Phase
Configuration C
Booster tank element View of calrod coils
Terminal Connections view of element
Terminal Connections view of element
Configuration D
Wash tank element View of calrod coils
Configuration B
Booster tank element View of calrod coils
Configuration A
Booster tank element View of calrod coils
Terminal Connections view of element
Terminal Connections view of element
ELECTRICAL SERVICE (Cont.)
Heater Element Wiring – Booster Tank and Wash Tank Heater Elements
Refer to the illustrations and follo
w the steps below to properly install ter minal jumpers and
to make line pow
er connections to a replacement element.
Step 1. Hold the element assembly with the calrod coils facing toward you. Step 2. Match your element coil to Configuration A, B, C, or D. Step 3. Rotate your element coils to match the correct conf iguration. Step 4. Flip the element over and match your element to the cor rect ter minal configuration. Step 5. Install terminal jumpers according to the illustration for your voltage requirement. Step 6. Install the element and make your line connections 1L1, 1L2, or 1L3 per the illustration.
ELECTRICAL SERVICE
1L1
1L2
1L3
1L1
1L2
1L3
1L1
1L2
1L3
1L1
1L2
1L3
1L2
1L1
1L1
1L2
1L1
1L2
1L1
1L2
1L1
1L2
1L3
1L1
1L2
1L3
1L1
1L2
1L3
3
1L1
1L2
1L3
1L1
1L2
1L3
1L1
1L2
1L3
3
1L
1L
20
Low voltage 208-230V/1PH
Only
Motors
Motor Specifications
Voltage: Standard motors are multi-voltage
Low voltage: 208-230VAC High voltage: 460VAC or 575VAC only
Phase: Motors may be single or three phase
Wiring Connections:
Refer to the diagrams below for 3 phase motor lead wiring.
Low voltage High Voltage 575V/3PH 208-230V/3PH 460V/3PH Only
Refer to the diagram at right for single phase motor lead wiring.
Troubleshooting:
Motor will not run:
1. Check incoming power to control cabinet.
2. Check for tripped manual motor star ter (overload) in control cabinet. (Refer to Motor Overload service section for the proper setting)
3. Check power at motor contactor.
Motor runs hot and trips motor starter overload:
1. Check for proper voltage between L1-L2, or (L1-L2, L2-L3, L1-L3 for 3 phase).
2. Check FLA on motor leads L1, L2, (also L3 for 3 phase) using amp tester. (Motor full load amp (FLA) ratings are stamped on motor nameplate).
Motor Replacement:
1. Disconnect the power to the machine.
2. Disconnect the wires at the motor junction box.
3. Make note of the motor connections in order to phase the replacement correctly.
4. Install the new motor and check for proper rotation.
5. Proper shaft rotation is clockwise looking at the rear of the motor.
6. Motor rotation can be reversed by switching L1 and L2 on 3 phase motors. Single phase motor rotation cannot be reversed
7. Replacement motors are available as complete assemblies.
8. Champion cannot provide replacement bearings, stators, or rotors for motor repair parts.
ELECTRICAL SERVICE
321
LINE
654
987
321
654
987
321
LINE
2
8
J
LINE
LINE
L1
L2
4
3
21
Dual Float Switches –
Troubleshooting:
The dual float controls fill and heat circuits.
Identifying a Dual Float Problem:
The most common trouble conditions associated with a dual float failure are:
1. The tank fills constantly.
2. The tank heat will not come on.
Inspect the Dual Float:
1. Be sure that the dual float assembly is clean and free of scale build-up.
2. Be sure that the stainless steel balls on the float assembly move up and down freely.
In addition to checking the float operation, perform the following—
System Checks:
1. All drain valves are fully closed.
2. Incoming water supply Flow Pressure is 20-22 psi [138-151 kPa].
3. Fuses in control cabinet are good (Electric Heat Only).
4. Tank Heat thermostats and/or High limit thermostats operate correctly.
5. Booster Heat ther mostats and/or High limit ther mostats operate cor rectly.
ELECTRICAL SERVICE
Dual Float Troubleshooting Diagrams:
YES
Water Shuts OFF
Machine is in
Final Rinse Mode
Not a Dual Float
Problem
System Checks
System Checks
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
Wash or Prewash
Tank Fills Constantly
Is Tank Full
of Water?
Are the Float
Balls Up?
Close Drain Valve
Clean
Float Assy
Is Heat ON when called
for?
Replace
Dual
Float
Check
Solenoid
Valve
Are the Float
Balls Up?
Check
Solenoid
Valve
Is Heat ON when called
for?
Replace
Dual
Float
Clean
Float Assy
Close Drain Valve
Is Tank Full
of Water?
Check to ensure
that
Rinse-Saver Lever
is not
Operated
Water Runs Constantly
Through Final Rinse Piping
22
Canister No.1
L-R Direction
Water Supply In
Canister No.1
Canister No.2
ELECTRICAL SERVICE
Figure 8
Front V ie w
Typical 40°F/22°C Rise Booster
One T ank – T otal 36Kw Shown
Figure 9
Front V ie w
Typical 70°F/39°C Rise Booster
Two-Tank – Total 57Kw Shown
12Kw
9Kw
9Kw
9Kw9Kw
9Kw
12Kw
12Kw
Dishwasher
Unload
End
12Kw
Electric Booster Heater — Element Installation
Refer to Fig. 8 and F
ig. 9
Champion built-in boosters are constructed of stainless steel and have locations for three electric booster heater elements.
1. The two booster conf igurations for rack conveyor models are:
Single tank - 40°F/22°C rise booster Two tank - 70°F/39°C rise booster
The total Kw rating of the booster assembly is determined by the model number of the machine and the minimum temperature of the incoming water supply.
2. The highest rated Kw element
should always be installed in the bottom right corner location of booster canister No. 1.
1R013
Highest Rated Kw Element
installed in bottom right corner
of Canister No.1
1R012
Loading...