Project
Item No.
Quantity
D-H1 GAS DOOR-TYPE
STANDARD FEATURES
• Automatic tank fill
• Detergent/chemical connection provisions
• Door safety switches
• Automatic electric drain valve
• One gas heating system for boosting
the final rinse and tank heat
• Interchangeable upper and lower spray arms
• Low-water tank heat protection
• Pump motor, drip-proof 1 Hp
• Stainless steel pump impeller
• Stainless steel front and side panels
• Top-mounted, splash-proof control console
• Single point electrical connection (see chart)
• Balanced door lift system
Gas
D-H1 GAS
Door-type
Gas Heated
High Temperature Dishwasher
OPTIONS & ACCESSORIES
Corner Model
Drain Tempering Kit
Vent Fan Control Switch
(1M) 9/06 Printed in U.S.A.
CH017
SPECIFIER STATEMENT
Specified unit will be Champion model D-H1 gas
heated high temperature dishwashing machine.
Features top mounted control cabinet, balanced
door-lift with door safety switch, interchangeable
stainless steel wash and rinse arms, 55 racks/hr.,
1.1 US gals/rack. Constructed of Type 304 SST.
1 year parts and labor warranty.
Champion Industries, Inc.
P. O. Box 4149, Winston-Salem, NC 27115
Tel: 336/661-1556 Fax: 336/661-1979
www.championindustries.com
D-H1 GAS
2
0-1/8" 2-7/8"
STRAIGHT THROUGH OPERATION
Front
Inside Tracks
5
5-1/4" Min.
2
5-1/4" Min.
20-1/8"
20-1/8"
Inside Tracks
Front
84"
Door
R
emoval
17"
C
lear.
75"
D
oors
Up
3
4"
Load
Height
5
7-1/2"
Machine
H
eight
7
2A
6
1
B
*Hatco
Gas Booster
Mod. # PMG-100
2
1
0-1/4"
2
5-7/8"
31-1/4"
4
1-1/4" Roll
1-1/8"
24-1/4"
20-7/8"
7-1/4"
2-1/8"
26−3/4"
10"
63−1/2"
27−1/2"
26−1/2"
13"
44−5/8"
5
−3/4"
MIN. 5−1/4"
26"
41"
24−5/8"
25−5/8"
2"
G
as Booster
7
2A
6
1B
20−3/4"
8−1/4"
31−3/4"
Door-type
Gas Heated
High Temperature Dishwasher
Length between table connections: 25-3/4"
Shipping weight crated: 775 lbs.
Booster shown is the PMG-100. Contact factory
*
or PMG-60 drawings and electrical information.
f
D-H1 GAS DOOR-TYPE
Side View
Gas
Dimensions shown in inches
Straight Through
Operation
Front View
Utilities
1 Electrical
A. Machine connection (see box)
B. Booster connection requires
15 amps @ 120/60/1
2 Hot Water
3/4" NPT hot water 140°F for 40°F rise
booster. 3/4" NPT hot water 110°F for
70°F rise booster. Flow pressure 20-22 psi.
3 Drain
A. 2" OD machine connection
B. 3/4" NPT relief valve to open drain
C. 1/2" NPT vent to open drain
D. 3/4" male threaded hose end
4 Gas
40°F rise - LP Gas 25 CFH for 60,000 BTU/hr.
70°F rise - LP Gas 41 CFHfor 100,000 BTU/hr.
PMG-60 requires 1/2" NPT.
PMG-100 requires 3/4" NPT.
5 Gas Flue - 4" OD exhaust
A. Rear of booster
Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice.
Champion Industries, Inc., P. O. Box 4149, Winston-Salem, NC 27115 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com
Natural 60 CFH for 60,000 BTU/hr.
Natural 100 CFHfor 100,000 BTU/hr.
Plan View
Typical Table
Corner Operation
Constuction
Warning: Gas burner intake air and exhaust
venting required in accordance with local codes.
Exhaust must be vented outside.
Plumbing Note: Because of variation inhouse-supplied
water pressure, pressure regulating valves (PRV’s)
for incoming water may be needed. The PRV’s can
be purchased from Champion or obtained locally.
Note: Water Hammer Arrestor (meeting ASSE-1010
standard or equivalent) to be supplied (by others) in
common water supply line at service connection.
Note: Specify vent location option on booster
when ordering.
Note: For corner application, contact Factory
Machine Load Amps
Minimum Maximum
Supply Ckt. Overcurrent
Voltage Amps Ampacity Device
Rated Conductor Protective
115/60/1 22 30 30
208/60/1 13 20 20
240/60/1 11 15 15
208/60/3 6 15 15
240/60/3 6 15 15
480/60/3 3 15 15
Warning: Plumbing, gas and electrical connections
should be made by qualified personnel who will
observe all the applicable plumbing, sanitary and
safety codes and the National Electrical Code.
SPECIFICATIONS
Capacities
Racks per hr. (NSF rated) 55
Wash tank (gal.) 9
Motor horsepower
Water consumption
Gal. per hr. (max. use) 61
Gal. per rack 1.1
Temperature °F
Wash 150
Rinse 180
Heating
Gas
PMG60 (40°F rise) 58,000 BTU/hr
PMG100 (70°F rise) 105,000 BTU/hr
Time cycle in seconds
Wash 40
Dwell 10
Rinse 10
Total cycle 60