Chamberlain Motorlift 5500 User Manual

Instructions – Garage Door Operator
Model MotorLift 5500
Thank you for purchasing this Chamberlain product.
114A2421D
For Service: (0044) (0) 1935 848 525
For Service: 0800 317847
GB
Declaration of Conformity
Automatic Garage Door Opener ..............................................Model No. ML5500
is in conformity to the applicable
sections of Standards.................................EN 300 220-3, EN55014, EN61000-3,
....................................................................................ETS 300 683 & EN60335-1
per the provisions & all amendments
of the EU Directives .....................................1999/5/EC, 73/23/EEC, 89/336/EEC
Declaration of Incorporation
Automatic Garage Door Opener Model No. ML5500, when installed and maintained according to all the Manufacturer’s instructions in combination with a Garage Door, which has also been installed and maintained accord­ing to all the Manufacturer’s instructions, meets the provisions of EU Directive 89/392/EEC and all amendments.
I, the undersigned, hereby declare that the equipment
specified above and any accessory listed in the manual
conforms to the above Directives and Standards.
THE CHAMBERLAIN GROUP, INC. Elmhurst, IL 60126 USA May, 2003
© 2003, Chamberlain GmbH
114A2421D All rights reserved Printed in Mexico
GARAGE DOOR OPENER WARRANTY
Chamberlain GmbH warrants to the first retail purchaser of this product that the product shall be free from any defect in materials and/or workmanship for a period of 60 full months (5 years) from the date of purchase.Upon receipt of the product, the first retail pur­chaser is under obligation to check the product for any visible defects.
Conditions: The warranty is strictly limited to the reparation or replacement of the parts of this product which are found to be defective and does not cover the costs or risks of transportation of the defective parts or product.
This warranty does not cover non-defect damage caused b y unreasonab le use (including use not in complete accordance with Chamberlain’s instructions for installation, operation and care;failure to provide necessary maintenance and adjustment;or any adaptations of or alterations to the products), labor charges for dismantling or reinstalling of a repaired or replaced unit or replacement batteries.
A product under warranty which is determined to be defective in materials and/or workmanship will be repaired or replaced (at Chamberlain's option) at no cost to the owner for the repair and/or replacement parts and/or product.Defective parts will be repaired or replaced with new or factory rebuilt parts at Chamberlain's option.
If, during the warranty period, the product appears as though it may be defective, contact your original place of purchase.
This warranty does not affect the purchaser’s statutory rights under applicable national leg­islation in force nor the purchaser’s rights against the retailer arising from their sales/pur­chase contract. In the absence of applicable national or EU legislation, this warranty will be the purchaser’s sole and exclusive remedy, and neither Chamberlain nor its affiliates or distributors shall be liable for any incidental or consequential damages for an y express or implied warranty relating to this product.
No representative or person is authorized to assume for Chamberlain any other liability in connection with the sale of this product.
Barbara P. Kelkhoff
Manager, Reg. Affairs
START BY READING THESE IMPORTANT SAFETY RULES
CONTENTS
These safety alert symbols mean Caution – a personal safety or property damage instruction. Read these instructions carefully. This garage door opener is designed and tested to offer reasonable safe service provided it is installed and operated in strict accordance
with the following safety rules.
Failure to comply with the following instructions may result in serious personal injury or property damage.
Caution: If your garage has no service entrance door, Model 1702EML Outside Quick Release must be installed. This accessory allows manual operation of the garage door from outside in case of power failure.
SAFETY RULES: Page 1 DOOR TYPES: Page 1 – Illustration TOOLS REQUIRED: Illustration HARDWARE PROVIDED:
Page 1 – Illustration
BEFORE YOU BEGIN: Page 2 COMPLETED INSTALLATION:
Page 2 – Illustration
ASSEMBLY:
Page 2 Illustrations -
INSTALLATION:
Pages 2-3 Illustrations -
PROGRAMMING THE CODE:
Page 4 – Illustration
ADJUSTMENT:
Page 4 Illustrations -
INSTALL THE PROTECTOR: (Optional):
Page 4 – Illustration
OPERATION OF YOUR OPENER: Page 5 CARE OF YOUR OPENER: Page 5
MAINTENANCE OF YOUR OPENER: Page 5 PROBLEMS: Pages 5-6 SPECIAL FEATURE OF THE ML5500:
Page 6 – Illustration
ACCESSORIES:
Page 6 – Illustration
SPECIFICATIONS: Page 6 REPLACEMENT PARTS:
Illustrations -
2726
25
24
23
2220
19
189
85
4
3
2
1
DOOR TYPES
A. One-Piece Door with Horizontal Track Only B. One-Piece Door with Horizontal and Vertical Track:
Special door arm (F, The Chamberlain Arm™) required. See your dealer.
C. Sectional Door with Curved Track:
See B – Connect Door Arm.
D. Double-wing door: Special door arm required. See your dealer. E. Canopy door:
Special door arm (F, The Chamberlain Arm™) required. See your dealer.
18
1
Assembly Hardware: (1) Bolts (8) (2) Hex Screws (4) (3) Lock Nuts (12) (4) Coupling Installation Hardware: (5) Carriage Bolts (2) (6) Wood Screws (4) (7) Screws (2) (8) Clevis Pins (3)
(9) Hex Screws (4) (10) Rope (11) Handle (12) Insulated Staples (13) Anchors (2) (14) Lock Washers (6) (15) Nuts (6) (16) Ring Fasteners (3) (17) 8mm Anchors (4) (18) Sheet Metal Screws (2)
HARDWARE PROVIDED
3
Keep garage door balanced. Sticking or binding doors must be repaired. Garage doors, door springs, cables, pulleys, brackets and their hardware are under extreme tension and can cause serious personal injury. Do not attempt to loosen,
move or adjust them. Call for garage door service. Do not wear rings, watches or loose clothing while installing
or servicing a garage door opener. To avoid serious personal injury from entanglement, remove
all ropes connected to the garage door before installing the door opener.
Installation and wiring must be in compliance with your local building and electrical codes. Connect the power supply
cord only to properly earthed mains. Lightweight doors or fiberglass, aluminum or steel must
be substantially reinforced to avoid door damage. (See
page 4.) The best solution is to check with your garage door manufacturer for an opener installation reinforcement kit.
The safety reverse system test is very important. Your garage door MUST reverse on contact with a 50mm (2") obstacle placed on the floor. Failure to properly adjust the opener may result in serious personal injury from a closing garage door. Repeat the test once a month and make any
needed adjustments. This unit should not be installed in a damp or wet space.
Door must not extend over public byway during operation.
The force, as measured on the closing edge of the door, should not exceed 150 N (15kg). If the closing force is adjusted to more than 150 N, the Protector System must be installed. Do not use the force adjustments to compensate for a binding or sticking garage door.
Excessive force will interfere with the proper operation of the Safety Reverse System or damage the garage door.
Fasten the caution label adjacent to the lighted door control button as a reminder of safe operating procedures.
Disengage all existing garage door locks to avoid damage to garage door.
Install the lighted door control button (or any additional push buttons) in a location where the garage door is visible, but
out of the reach of children. Do not allow children to operate push button(s) or remote control(s). Serious
personal injury from a closing garage door may result from misuse of the opener.
Activate opener only when the door is in full view, free of obstructions and opener is properly adjusted. No one should enter or leave the garage while the door is in motion. Do not allow children to play near the door.
Use manual release only to disengage the trolley and, if possible, only when the door is closed. Do not use the red
handle to pull the door open or closed. Disconnect electric power to the garage door opener
before making repairs or removing covers.
1-GB