Start by Reading These Important Safety Instructions
General safety guidelines
efore you begin the installation:
B
Please read the operating instructions and especially the precautions. Keep the manual for future reference
and pass it on to a possible subsequent owner.
The following symbols are placed in front of instructions to avoid personal injury or property damage. Read
these instructions carefully.
CAUTION Personal injury or property damage
mportant safety information
I
- The installer (specialist) must carefully read and
understand these instructions before starting any work.
Before first use and at least annually a specialist must
inspect powered windows, doors and gates regarding
their safe condition.
Specialist according to EN12635 is, who on the basis of
their technical training and experience, has sufficient
knowledge in the field of powered windows, doors and
gates and moreover is familiar with relevant state
occupational safety regulations and generally accepted
rules of technology in such an extent that he is also
able to assess the safe working condition of powered
windows, doors and gates.
- The door should be balanced. Unmoving or stuck doors
must be repaired. In an unbalanced state, garage
doors, door springs, cables, discs, brackets and rails
are under extreme tension, which can lead to serious
injury. Do not attempt to loosen, move or realign the
door, but contact service centre or a door professional.
- During the installation or maintenance of a door opener,
no jewellery, watches or loose clothing should be worn.
- To avoid serious personal injury due to entanglement,
remove all cables and chains connected to the door
before installing the door opener.
- During installation and electrical connection, the local
building and electrical regulations must be observed.
This device complies with Protection Class 2 and
does not require grounding.
- To avoid damage to very light doors (such as fibre
glass, aluminium or steel doors), an appropriate
reinforcement should be added.
To do so, contact the door manufacturer.
- The automatic safety reverse system should undergo a
test. Upon contact with a 50 mm high barrier on the
ground, the garage door MUST return. Failure to
properly adjust the door opener can result in serious
personal injury from a closing garage door. Repeat test
once a month and make any needed changes.
- This system must not be installed in damp or wet areas.
CAUTION Danger due to electrical current or voltage
- To remind all operators of the safe operation, in
addition to the illuminated wall switch a warning sign
to protect children should be affixed. The warning
signs about the risk of trapping should be placed in
clearly visible spots.
- Children should be supervised to ensure that they do
not play with the device.
- This device is not intended for use by persons
(including children) with restricted physical, sensory or
mental abilities or lack of experience and/or
knowledge, unless they are supervised by a person
responsible for their device.
- All barriers / locks are deactivated to avoid damage to
the door.
- If necessary, installed control equipment MUST be
mounted within sight of the door and out of reach of
children. Children should not be allowed to operate
the buttons or remote controls. Misuse of the door
opener can result in serious injury.
- The door opener should ONLY be used if the operator
can see the entire door area and is assured that it is
free of obstacles and the door opener is set correctly.
No one may pass through the door while it is moving.
Children must not be allowed to play in the vicinity of
the door.
- Use the manual release only for the separation of the
carriage from the drive and – if possible – ONLY with
the door closed.
Do not use the red handle to push the door up or pull
it down.
- Before performing any repairs or removing covers, the
door opener should be separated from the electric
power supply.
- This product has a transformer with a special power
cord. In case of damage this MUST be replaced with
an original transformer by aqualified technician.
- Operation of the emergency release can lead to
uncontrolled movements of the door, if springs are
weak or broken or if the door is unbalanced.
- During operation, the gate should not under any
circumstances obstruct public passageways.
- Mount the release handle of the emergency release
at a height less than1.80 m.
These instructions are original operting instructions according to EC Directive 2006/42/EC.
Please read through all of the instructions carefully, as they contain importan information about the product.
Please pay attention to and follow the instructions provided. particularly the safety instructions and warnings.
Keep these instructions in a safe place for later reference.
1
1
13 mm, 10 mm, 8 mm
5.5 mm
M
a
r
k
e
r
P
e
n
8
95 mm
Minimum distance from
e
dge of curtain to edge of
d
oor bracket 45 mm
ARTON INVENTORY
C
TOOLS REQUIRED
2
1. Instruction manual (this document)
2. Stop collar
3. Clamp bracket, plates, washers (2) and nuts (2)
4. TX4EVS Premium transmitter (2)
5. 128EV wireless wall button (1)
6. Opener
7. Self tapping screws (2) (for pinning the door)
8. Rivets (4)
9. Warning label and risk of entrapment label
10. Extension poles (2)
1. Ladder
2. Adjustable wrench for U-bolts already installed
on the door
. 8 mm socket, 10 mm socket and 13 mm extended
3
socket and socket wrench
4. 300 mm socket extension (for minimum side-room
installations)
. Drill and 5.5 mm drill bit
5
6. Philips-head screwdriver
7. Marker pen
8. Rope
9. Door stand (not shown)
3
DOOR REQUIREMENTS
The LM750EVGB is suitable for spring balanced
Residential single skin rolling garage doors with:
• Maximum door height of 4.5 m
• Maximum curtain area of 18 m
2
• Maximum door mass of 120 kg
Door axle diameter must not exceed 35 mm.
Ensure that there is at least 45 mm from the edge of the curtain to the edge of the bracket. If the roller door
drum wheel is on the edge of the curtain or is a smaller diameter, additional clearance may be required.
Assemble the opener to the door axle and the existing door bracket using the U clamp assembly provided.
Tighten to 25-28 Nm. Full installation process is in section 13.
Intended use:
The garage door operator is intended exclusively for the impulse operation of spring-compensated
residential/non-commercial sector single skin rolling Garage door.
Note the manufacturers specifications regarding the door and operator combination.
The door must meet mechanical requirements according EN 12604.
2
DN
UP
P
S
6
6
1
2
3
7
A
B
C
B
D
2
34
5
8
1
DN
UP
1
2
3
P
S
1
A
B
C
B
D
8
2
34
5
6
6
7
DN
UP
P
S
6
6
1
2
3
7
5
4
2
3
1
2
34
5
8
1
ONTROL PANEL
C
4
. Terminal Block: used for external accessories (see chart below).
1
RefFunction
Push button
5
ommon
C
4
3 CommonWhite-veCommon terminal for push button, obstruction
2Obstruction Detection
Beams
Accessory Power
1
NOTE: The terminal block is behind a plastic cover in the back housing. Use a small screwdriver to lever
open the plastic cover if access to the terminal block is required. All wires should be secured appropriately.
Colour
Red
White
Grey
Green
PolarityComment
+ve
ve
-
+ve
+ve
Dry contact input for push button wired wall
ontrols
c
Common terminal for push button, obstruction
detection beams & accessory power
detection beam & accessory power
Obstruction detection beam Input (pulsing
type only) - see section 18
24v dc 50 mA accessory output available for a
universal receiver (output not active in Standby Mode)
2. DN Button: used to drive the door DOWN
3. UP Button: used to drive the door UP
4. P Button: used to “PROGRAM” the DOOR LIMITS (see section 14)
5. S Button: used to “SAVE” and “DELETE” the “REMOTE CONTROLS” (see section 21)
6. LEDs: 1. Program DOWN, and Diagnostic code indicator Number 1
2. Program UP indicator
3. Diagnostic code indicator Number 2
7. Control Button: Used to activate the door when remote controls are not available. Open - Stop - Close.
8. Courtesy Light: turns on during operation and automatically turns off after a period of 3 minutes
3
5
Non opener side
Opener side
Boss
1
TESTING THE DOOR
Complete the following test to ensure your door is well
balanced, and not sticking or binding:
• Disable all locks and remove any ropes connected to the
garage door.
Lift the door to about halfway and then release it. The
•
door should remain spring balanced.
• Raise and lower the door to determine if there are any
sticking or binding points (20 kg is the absolute maximum
allowable to raise or lower the door in any position).
If your door does not hold in place or the door binds or
sticks, call a qualified door technician before installing the
opener.
6
ATTACHING THE STOP COLLAR
• The stop collar is required to be installed on the
opposite side of the door to where the opener is to be
installed.
• Ensure the U-Bolt holding the door shaft to the door
bracket is tightly secure.
(NOTE: This U-Bolt must not be removed or loosened)
• Remove the bolt assembly from the plastic stop
collar. Open the collar as wide as possible and push
it onto the door shaft.
• Fit the stop collar hard against the boss of the
door drum. Reinstall the bolt assembly onto the
stop collar and tighten.
ATTACHING THE WEIGHT BAR (OPTIONAL*)
7
If the door has a lifting handle, remove the handle, nuts & bolts.
Place the weight bar over the handle holes, insert the
extended bolts through the weight bar & fasten the handle back in
place.
• Place the weight bar in the centre of the door as shown.
SAFETY CHECK!
Is the stop collar installed?
YES: proceed to the next
step
NO: install the stop collar
before proceeding
If the door curtain does not have a handle you will need to follow
these instructions:
• Use a marker pen to mark the two hole positions.
• Drill two 5.5 mm holes through the two marked
positions, then place the weight bar on the inside of the
door.
• Use the bolts, washers and nuts (provided) to
fasten the weight bar in place.
*(Not supplied with the opener. Please refer to your door supplier.)