Challenger SL01, SL01B, SL02B, SL03, SL03B Instruction Manual

...
22
22
2 PRODUCT DESCRIPTION
Item
Item
Item
Quantity
Quantity
Quantity
Pattern
Pattern
Pattern
SL01, SL01B / SL02, SL02B
Manual
1
1
1
INSTRUCTION MANUAL
Lens shields
Detector
Detector
Wood screws Φ4x25.4MM +Rubber
washers
Wood screws Φ4x25.4MM +Rubber
washers
3
Manual
1
Lens shields
SL01/SL01B/SL02/
SL02B/SL03/SL03B
Φ3.5 x 10MM
Screws
Rubber washer
Rubber washer
1 PACKAGE CONTENTS
SL01, SL01B, SL02, SL02B, SL03, SL03B are passive infra red sensors to switch various types of load upon detection of movement. Suitable for indoor or outdoor use and used in residential or commercial environments.
MOTION DETECTOR LIGHT CONTROL
SL01/SL01B/SL02/ SL02B/SL03/SL03B
MOTION DETECTOR LIGHT CONTROL
SL01/SL01B/SL02/ SL02B/SL03/SL03B
MOTION DETECTOR LIGHT CONTROL
1
Corner mounting bracket
Rated Voltage
230V~ 10% 50/60Hz
230V~ 10% 50/60Hz
230V~ 10% 50/60Hz
CHALLENGER_SL01/SL01B/SL02/SL02B/SL03/SL03B _Instructions_Rev01
3.28.0218401810101
LEDs OFF.
Load ON 2sec, then OFF.
Test mode
Warning
OFF
Watch
1S.
W
W
W
Load ON.
No test mode
YES
Warning
OFF
Watch
1S.
LEDs all OFF.
LEDs all OFF.
Load OFF.
W
W
2sec
2sec
5 TROUBLE SHOOTING
If the detector is not functioning correctly, please check the following table for assistance:
Problem
Lighting device does not turn on
Nuisance triggering
Lighting device does not turn off
LED
notondoes
turn
Possible cause
1.Exceeding the detection range.
2.No power supplied.
3.TIME knob is not located to TESTposition.
4. Wired
incorrectly.
1. time setting.
2.D is nuisance triggered.
3.Wired incorrectly.
Incorrect
etector
There are heat sources, highly reflective objects or any objects which may be swayed in the wind within the detection coverage.
1. Power does not turn on.
2. Wired incorrectly.
3. LUX Knob
incorrectly.
4. Malfunctioned load.
adjusted
Suggested solution
1. Walk in the effective detection range
2. Switch on the power.
3.TIME knob must be located toTEST position.
4. Refer to wiring diagrams.
1.To test the delay time specified onTIME
check is
triggered if light­ing device off as the delay time is up.
2. Keep away from detection coverage to avoid activat­ing while doing
test.
3. Make sure load and wires are connected correctly.
knob and nuisance
does not turn
the
detector
detector
Avoid aiming the toward any heat sources, such as air conditioners, electric fans, heaters or any highly reflective surfaces. Make sure there are no swaying objects within the detection coverage.
detector
1. Switch on the power.
2. Refer to wiring diagrams ( FIG.5) and oad is malfunctioned.
check if t he
l
3. Check if LUX knob are set
the correct position.to
4. Replace the disabled load with a new one.
NOTE
The following conditions may cause lower sensetivity:
In very foggy conditions, the sensitivity may be reduced due to moisure collating on thelens. In very hot conditions, the sensitivity may be reduces as high ambient temperature could be close to body temperature. In cold conditions when heavy clothing is used, very little heat is emitted from the body (especially if face is covered) Cleaning: Wipe with dry cloth only. Soap or roughcloth may damage the detector lens.
FIG.22
FIG.23
Slot path
Distributed by:
CHALLENGER SECURITYPRODUCTS 10 Sandersons Way, Blackpool, FY4 4NB Email enquiries.challenger@adivision.co.uk Website: www.challenger.co.uk
:
RoHS
Conform
CAUTION!
Due to our policy of continuous improvement we reserve the right to change specification without prior notice. Errors and omissions excepted. These instructions have been carefully checked prior to publication. However, no responsibility can be accepted by Challenger for any misinterpretation of these instructions.
CHALLENGER_SL01/SL01B/SL02/SL02B/SL03/SL03B _Instructions_Rev01