Chaffoteaux & Maury Celtic 2.20FF RSc Instructions For Use Manual

Page 1
Supplied By www.heating spares.co Tel. 0161 620 6677
Celtic 2.2OFF
COMBINATION BOILER
RSC

instructions for use

(leave these instructions with the User or at the Gas Service meter)
Page 2
Supplied By www.heating spares.co Tel. 0161 620 6677
TO TURN
Set the selector switch to the centre the 9as
right.
OFF THE BOILER
by
turning the lever on the gas
Position OFF. Turn off
service
tap to the

HOW YOUR BOILER WORKS

PRODUCTION OF HOT WATER
This boiler is designed to give hot water at different tem-
peratures and is fitted with a temperature selector (26 ­fig. 1). To obtain the hottest fully in the + direction. In this position the burner may cycle high to low. this is normal. Larger
be obtained by turning
Water
turn the selector knob
amOUntS
of water can
the knob towards the-sign.
Fig. 1
Fig.
2

LIGHTING THE BOILER

1) Switch on the electricity.
2) Turn the lever on the gas service tap to the left (19 - fig.
2).
3) Set the selector switch to required position. To the left, hot water only or to the right for heating’and
hot water
(28 -fig. 1).
4) Press the ignitor button (23 -fig. 1)
-
The
fan will change to high
bustion chamber.
speed to purge the com-
- After approximately : 5 seconds the spark generator creates a continuous spark to light the pilot.
- When
- If the pilot goes out repeat above.
5) In winter. check ihai the flow isolating valve (17 - fig. 2) is wide open.
TO
TURN OFF THE CENTRAL
Set the selector sv!tch (28 - fig. 1) to the left. The boiler will only Operate on a demand for hot water. Your installer may have fitted a clock Into the system which will turn heating off aufcmaticatty.
the pilot is alight, viewed through the sight glass, wait a further 15 seconds before slowly relea­sing the button.
HEATING
(summer)
the
HEATING
The boiler is automatically self adjusting
heating. It is normal for the boiler to stay alight all the time but with the flame height reduced.
when on central
The g&will be at high Rame when the maximum output is
required, when it is cold or on start
UP.
CONTRPLS
. .
INSTALLATION WITHOUT A ROOM THERMOSTAT
Set the boiler thermostat (29 - fig. 1) as required depen­ding on the required internal temperature. To increase the heat turn to re gauge (24 - fig. 1) shows the temperature of the water going to the radiators.
INSTALLATION
- 3et the control on the room thermostat to the desired temperature which will automatically control the firing of the boiler to give the chosen room temperature.
- During cold weather, the boiler thermostat (29 - fig. 1) should be left on maximum, turned to position +.
- In mild weather it is recommended that the thermostat is placed in an intermediate position.
TO
ISOlATE THE HEATlNG CIRCUIT DURING THE SUMMER
In
some
been operating continuously for a period providing hot water to get gravity circulation in the heating pipes. It will be noticed that the pipes the first radiator lows.
- The valve (17 - fig. 2) to prevent this circulation.
- When switching heating flow.
- Do not forget to open the valve at the start of the heating season when the selector switch is set to “Winter”.
PRESSURE GAUGE (30 -fig.
This shows the water pressure in the central heating pipe­work when
increase
will operate at 3 bar. Your instalier will be able IO advise you how to re-pressurise the system if necessary.
+. to reduce the
WITH
heat turn to -. The temperatu-
A ROOM THERMOSTAT
installations it is possible, after the boiler has
will heat up. To avoid
heating flow
cold
it should read not less than 1 bar. This wilt
as
the system heats
to
are getting hot and eventually
this, isolate
connection is fitted with an isolating
‘Summer’ also close the valve on the
1)
up. A
pressure relief valve