Celestron VMC30SB-1, VMH30SB-1 User Manual

Wall Mounted Inverter Mini-Split System
VMC30SB-1 / VMH30SB-1
2 Room Air Conditioner
Room Air Conditioner Installation Manual
TABLE OF CONTENTS
Safety Precautions............................3
Introduction ........................................6
Features ...........................................6
Installation ..........................................7
Installation parts...............................7
Installation tools ...............................7
Installation map................................8
Selecting the best location .............9
Piping length and elevation...........10
Fixing installation plate ..................11
Drilling a hole in the wall ...............11
Flaring work ...................................12
Connecting the piping ..................13
Connecting the cables ..................19
Checking the drainage ..................22
Forming the piping.........................23
Air purging......................................24
Test running ...................................26
Installation guide at the seaside ...28
Four type "A" screws & plastic
anchors
Connecting cable
Installation guide map
Pipes: Gas side
Liquid side
Insulation materials
Additional drain pipe
[Outer diameter......15.5mm(0.61in)]
Two type "B" screws
Level gauge
Screw driver
Electric drill
Hole core drill [ø70mm(2.76in)]
Horizontal level
Flaring tool set
Specified torque wrenches
1.8kg.m, 4.2kg.m, 5.5kg.m,
6.6kg.m (different depending on model No.)
Adjustable Wrench .......Half union
A glass of water
Screw driver
Hexagonal wrench(4mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Owner's manual
Thermometer
Remote control holder
Installation
Requirements
Required Parts Required Tools
Installation Manual 3
ENGLISH
Safety Precautions
To prevent the injury of the user or other people and property damage, the following instructions must be followed.
Be sure to read before installing the air conditioner.
Be sure to observe the cautions specified here as they include important items related to safety.
Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness is
classified by the following indications.
The meanings of the symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Installation
Be sure not to do.
Be sure to follow the instruction.
Safety Precautions
Always electrically ground the equipment.
• Otherwise, it may cause electrical shock.
Don’t use a power cord, a plug or a loose socket which is damaged.
• Otherwise, it may cause a fire or electrical shock.
For installation of the product, always contact the service center or a professional installation agency.
• Otherwise, it may cause a fire, electrical shock, explosion or injury.
Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit.
• If the electrical cover of the indoor unit and the service panel of the outdoor unit are not attached securely, it could result in a fire or electric shock due to dust, water, etc.
Always install an air leakage breaker and a dedicated switching board.
• No installation may cause a fire and electrical shock.
Do not keep or use flammable gases or combustibles near the air conditioner.
• Otherwise, it may cause a fire or the failure of product.
Ensure that an installation frame of the outdoor unit is not damaged due to use for a long time.
• It may cause injury or an accident.
Do not disassemble or repair the product randomly.
• It will cause a fire or electrical shock.
4 Room Air Conditioner
Safety Precautions
Do not install the product at a place that there is concern of falling down.
• Otherwise, it may result in personal injury.
Use caution when unpacking and installing.
• Sharp edges may cause injury.
Take the power plug out if necessary, holding the head of the plug and do not touch it with wet hands.
• Otherwise, it may cause a fire or electrical shock.
Do not use the power cord near the heating tools.
• Otherwise, it may cause a fire and electrical shock.
Do not open the suction inlet of the indoor/outdoor unit during operation.
• Otherwise, it may electrical shock and failure.
Do not allow water to run into electrical parts.
• Otherwise, it may cause the failure of machine or electrical shock.
Hold the plug by the head when taking it out.
• Otherwise, it may cause electric shock and damage.
Never touch the metal parts of the unit when removing the filter.
• They are sharp and may cause injury.
Do not share the outlet with other appliances.
• It will cause an electric shock or a fire due to heat generation.
Do not use the damaged power cord.
• Otherwise, it may cause a fire or electrical shock.
Do not modify or extend the power cord randomly.
• Otherwise, it may cause a fire or electrical shock.
Take care so that the power cord may not be pulled during operation.
• Otherwise, it may cause a fire or electrical shock.
Unplug the unit if strange sounds, smell, or smoke comes from it.
• Otherwise, it may cause electrical shock or a fire.
Keep the flames away.
• Otherwise, it may cause a fire.
Do not step on the indoor/outdoor unit and do not put anything on it.
• It may cause an injury through dropping of the unit or falling down.
Do not place a heavy object on the power cord.
• Otherwise, it may cause a fire or electrical shock.
When the product is submerged into water, always contact the service center.
• Otherwise, it may cause a fire or electrical shock.
Take care so that children may not step on the outdoor unit.
• Otherwise, children may be seriously injured due to falling down.
Operation
Installation Manual 5
ENGLISH
Safety Precautions
Installation
Install the drain hose to ensure that drainage can properly occur.
• Otherwise, it may cause water leakage.
Install the product so that the noise or air from the outdoor unit may not cause any damage to the neighbors.
• Otherwise, it may disturb the neighbors.
Always inspect gas leakage after the installation and repair of product.
• Otherwise, it may cause the failure of product.
Keep level parallel when installing the product.
• Otherwise, it may cause vibration or water leakage.
Avoid excessive cooling and ventilate the area being cooled occasionally.
• Otherwise, it may do harm to your health.
Use a soft cloth to clean. Do not use wax, thinner, or a strong detergent.
• The appearance of the air conditioner may deteriorate, change color, or develop surface flaws.
Do not use an appliance for special purposes such as preserving animals vegetables, precision machine, or art articles.
• Otherwise, it may damage your properties.
Do not place obstacles around the inlet or outlet air flow areas.
• Otherwise, it may cause the failure of appliance or an accident.
Operation
6 Room Air Conditioner
Introduction
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the air conditioner.
This symbol indicates special notes.
NOTICE
Introduction
Symbols used in this Manual
Features
Air Inlet
Front Panel
Air Filter
Signal Receptor
Air Intake Vents
Base Plate
Air Outlet Vents
Connecting Wires
Drain Hose
Installation Manual 7
ENGLISH
Installation
Installation
Read carefully, and then follow step by step.
Figure FigureName
Screw driver
Electric drill
Measuring tape, Knife
Hole core drill
Adjustable Wrench
Torque wrench
Ohmmeter
Hexagonal wrench
Ammeter
Gas-leak detector
Thermometer,
Horizontal level
Flaring tool set
Name
Type "A" screw and plastic anchor
Type "B" screw
Remote control holder
Installation plate
Installation Parts
Installation Tools
8 Room Air Conditioner
Installation
Installation Map
Installation parts you should purchase.
NOTE: refrigerant line wall thickness must be at least 0.8 mm(0.031 inch)
Air Discharge
Forced Operation Button
Operation Indication Lamps/
Signal Receptor
Vinyl tape (Wide)
Apply after carrying out a drainage test.
To carry out the drainage test, remove the air filters and pour water into the heat exchanger.
Saddle
Gas side piping (Optional Parts) Liquid side piping (Optional Parts) Additional drain pipe
Vinyl tape (Narrow) Drain Hose
Base Plate
Air Outlet Vents
Air Inlet Vents
Connecting cable (Optional Parts)
Installation plate Sleeve
Bushing-Sleeve Putty(Gum Type Sealer)
Bend the pipe as closely on the wall as possible, but be careful that it doesn't break or kink.
NOTICE
Installation Manual 9
ENGLISH
Installation
Indoor unit
1. Do not have any heat or steam near the unit.
2. Select a place where there are no obstacles in front of the unit.
3. Make sure that condensation drainage can be conveniently routed away.
4. Do not install near a doorway.
5. Ensure that the interval between a wall and the left (or right) of the unit is more than 10cm(3.9in). The unit should be installed as high as possible on the wall, allowing a minimum of 20cm(7.9in) from ceiling.
6. Use a stud finder to locate studs to prevent unnecessary damage to the wall.
Outdoor unit
1. If an awning is built over the unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.
2. Ensure that the space around the back and sides is more than 30cm(11.8in). The front of the unit should have more than 70cm(27.6in) of space.
3. Do not place animals and plants in the path of the warm air.
4. Take the weight of the air conditioner into account and select a place where noise and vibration are minimum.
5. Select a place where the warm air and noise from the air conditioner do not disturb neighbors.
Select the best Location
More than 20cm(7.9in)
More than
10cm(3.9in)
More than
2.4m(7.9ft)
More than 10cm(3.9in)
More than 30cm(11.8in)
More than 70cm(27.6in)
More than 60cm(23.6in)
More than 30cm(11.8in)
More than 60cm(23.6in)