Celestron MicroDirect Pc Software Manual

Page 1
PC SOFTWARE MANUAL
MODEL #44316
Page 2
1. COMPUTER SOFTWARE- INSTALL
Although the MicroDirect® 1080p HD microscope is designed to stream video directly to a monitor or projector, you have the option to run the microscope on a Windows based computer with the included CD/DVD ROM disk. If you do not have a CD/DVD ROM drive, the software can be downloaded from our website www.celestron.com.
Note: The software is compatible with Windows systems XP/7/8/10 only. The software is not compatible with MAC
operating systems.
1.
CD ROM Install
+
Insert the driver CD into CD-ROM Drive and this will automatically display the following interface:
+
SELECT the Install Software button
+
The installation wizard will guide you through the whole process.
2. COMPUTER SOFTWARE- OPENING
1. Connect your MicroDirect® 1080p HD microscope to your PC using the included USB cable.
2.
Open the Portable Capture HD software by clicking the desktop icon.
2 | ENGLISH
Page 3
NOTE: If your MicroDirect® 1080p HD microscope becomes disconnected from your PC the following message box will appear:
3. COMPUTER SOFTWARE- DETAILS
A. CAPTURE STILL IMAGE
There are 2 ways to capture a photograph with the Portable Capture HD software:
1. Select ‘Photo’ shortcut icon in the main menu bar.
2. Select ‘Capture/Photo’ from the drop down menu.
ENGLISH | 3
Page 4
B. CAPTURE VIDEO
There are 2 ways to capture video with the Portable Capture HD software:
1. Select ‘Video’ shortcut icon in the main menu bar.
2. Select ‘Video’ from the drop down menu.
C. TIME LAPSE
1. Select ‘Timer’ shortcut icon and then set your time lapse information.
a. Choose between Photo or Video.
b. StartTime:
i. Set the start time- YEAR/MONTH/DAY/SPECIFIC TIME.
c. Interval (sec):
i. Select the interval between each photo or video (in seconds) to be taken.
d. Video time (sec):
i. If you have chosen video time- enter the length of the video clip
(in seconds) you want to be taken at each interval.
e. Total number:
i. Set the total number of images to be taken.
f. Once you are happy with your settings, select the ‘Start’ button and the time
lapse will begin.
g. Select ‘Stop’ to end the time lapse.
NOTE: Intervals can be from 1-999 for interval and total number of images.
This means with still images a maximum time lapse can cover just over 277 hours or 11.5 days. (999 seconds between image for 999 times).
4 | ENGLISH
Page 5
4. CALIBRATION AND MEASUREMENT
A. CALIBRATION
+
Make sure the X,Y Guide is ON (Options/XY Guide).
+
Place the included Calibration ruler on the stage under the microscope lens and focus.
+
Take a still image making sure the X,Y Guide and the lines on the calibration ruler are parallel.
+
Select the Calibration icon and using your cursor, click on a start line on the calibration ruler, hold the mouse button down and drag a dimension line across to the next black line on the calibration ruler.
+
Double-click on the image to enter into measurement interface window.
NOTE: The idea here is to measure a “known” distance on the
calibration ruler. For example 1mm or .5 mm.
+
A dimension line will appear and a dimension will be displayed above the line and a dialogue box will appear.
+
Enter the “known” distance that you measured, based on the calibration ruler.
+
The software will automatically calibrate the magnification rate.
+
Click ‘OK’ and the adjusted magnification rate will show in the upper right corner.
NOTE: Save this magnification rate, so that you may use it for
future settings.
+
Now you can take measurements on the saved image.
ENGLISH | 5
Page 6
B. MEASURING TOOLS
+
Select the Measurement icon
NOTE: This is a good time to verify your calibration. Using the ANY
ANGLE TOOL, take a measurement of the same “known” dimension you used in the Calibration step. If the measurement is the same or very close, the calibration was successful.
C. MEASUREMENT CHOICES
1. Any Angle Line Measurement
+
Click from one point and drag to the next point, and then release the click.
2. Continuous Line Measurement
+
The Continuous Line measurement allows you to measure any continuous desired length, not just a straight line.
Simply click and drag from one point to other desired point, and then release mouse button.
3. Radius Circle Measurement
+
Click and drag a line out to the desired radius and release the mouse button.
+
The radius, circumference and area of the circle will show up accordingly.
4. Diameter Circle Measurement
+
Click and drag a line out to the desired diameter and release the mouse button.
+
The diameter, circumference and area of the circle will show up accordingly.
5. Three Point Angle Measurement
+
Cllick any three points in an angle and the value of the angle will be displayed.
D. SET THE CALIBRATION MAGNIFICATION
+
So far the calibration and measurement features we have discussed involve the measurements on ONE image (your saved image)
and the magnifi cation rate was determined by the computer when calibrating.
+
The MicroDirect® Portable Capture HD software allows you to “lock in” a magnifi cation rate, which allows you to take multiple pictures
and then make measurements on them based on this “locked in” rate.
NOTE: Once the calibration is completed, you cannot change the physical position or focus range of your microscope, or you will
change the actual magnifi cation and your measurements will not be correct.
+
Click > Set magnifi cation > Set capture magnifi cation.
Now any pictures you take from this point forward will use the same magnifi cation rate for your measuring. Remember, you cannot change the position of the microscope or focus point or the magnifi cation will be wrong and you will have to reset it.
6 | ENGLISH
Page 7
5. NOTE TAKING AND MARKING THE IMAGE
HD Portable Capture includes functionality to mark, draw on, or and add notes to saved images. This can be handy for quick note taking and pointing out features on your specimen image.
A. MARKING
+
+
1. Line: Draws a straight line on the image.
2. Arrow: Draws a line with an arrow on the image.
3. Freehand: Allows user to draw freehand. Good for quick, handwritten notes.
4. Rectangle: Draws a box. Good for calling out features on the image or framing text.
SETTINGS
1. Line Properties: Allows for setting
To use this feature, click the Draw icon in the Image Preview window. The complete choices in the Draw dropdown menu are:
MAIN
the line type, size and color.
B. ADD TEXT
+
To type notes on the image, select the Type icon.
+
In the dropdown menu, you can choose the font type, size and color.
ENGLISH | 7
Page 8
6. SOFTWARE INTERFACE INSTRUCTIONS
A. MAIN WINDOW ICONS
Photo: Take a still image
Video: Start / Stop record video
B. MAIN MENU
1. File
Timer: Time Lapse feature
Full Screen: Streaming image- full size
(Press ESC or double-click to exit)
Photos Directory: Set the directory to store photos taken Videos Directory: Set the directory to store video taken
2. Options
3. Capture
Resolution: Change preview size Date/Time: Set to display system date/time on preview window Language: Choose different OSD language Crossing: Display cross on preview window Full-screen mode: Enter into full screen. Click ESC or double click to exit
Photo: Take a photo Video: Record a video clip
8 | ENGLISH
Page 9
C. MEASUREMENT INTERFACE INSTRUCTIONS
Save as
Copy to clipboard
Copy fi le
Previous
Next
Undo
Redo
Draw
Text note
Measurement
Calibration
7. CARE AND MAINTENANCE
Your Celestron MicroDirect® 1080p HD microscope is a precision optical instrument and should be treated with care at all times. Follow these suggestions and your microscope will need very little maintenance throughout its lifetime.
+
+
Store your microscope in a clean, dry place.
+
Never use your microscope where operation of such
devices is restricted. Improper use creates the risk of serious accident.
+
Only use your microscope within the 23° to 120°F (-5°
to 50° C) temperature range. Try to limit sudden temperature changes as this may create moisture in the microscope housing.
Do not try to access the internal components of your
microscope or attempt to modify it in any way. Only authorized technicians should perform maintenance or repairs.
+
Keep your microscope away from water and other
liquids. Never use it in rain or snow. Moisture creates the danger of fi re and electric shock.
+
If the exterior of your microscope needs cleaning, wipe
it with a moist cloth.
8. WARRANTY
Your Celestron MicroDirect® 1080p HD microscope has a two year limited warranty. Please visit the Celestron website for detailed information on all Celestron microscopes: www.celestron.com.
ENGLISH | 9
Page 10
© 2016 Celestron • All rights reserved. • www.celestron.com
2835 Columbia Street • Torrance, CA 90503 U.S.A. Telephone: 1(800) 421-9649 • Printed in China 2016
FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
+ Reorient or relocate the receiving antenna. + Increase the separation between the equipment and receiver.
This product is designed and intended for use by those 14 years of age and older. Product design and specifications are subject to change without prior notification.
+ Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
+ Consult the dealer or an experienced radio/TV technician for help.
Loading...