Celestron 52305, 52304, 52306 User manual

SPOTTING SCOPE
INSTRUCTION MANUAL
English
Thank you for purchasing a Celestron Regal M2 spotting scope. We trust that this spotting scope will provide you with years of enjoyment and faithful service. Please read the instructions carefully before using your spotting scope to ensure proper use and care.
Eyecup
Eyepiece Lock Collar
Objective Lens
Lens Shade
Focus Knob (Course/Fine)
Sighting Line
2
Tripod Mount (Rotating)
Tripod Mount Rotation Lock Screw
Eyepiece
Objective Lens Cap
Eyepiece Mount Cap
Eyepiece Cover
T-Adapter
WARNING
Never look at the Sun while using your spotting scope. Looking at the Sun can cause permanent eye damage.
BEFORE UsE
Attach your spotting scope to a sturdy tripod before viewing as the size and power of the spotting scope requires a solid tripod for stability to achieve clear, sharp images (Fig. 2).
AttAching thE EyEpiEcE
A zoom eyepiece is included with the Regal M2 spotting scope. To attach the eyepiece to the spotting scope, turn the eyepiece lock collar counterclockwise until it is loose and remove the eyepiece mount cover. Make sure that the protective lens cap is removed from the eyepiece and slide it into the eyepiece mount (Fig. 3a). When the eyepiece is fully seated turn the lock collar clockwise to secure the eyepiece and hold it in place (Fig 3b). Do not attempt to attach or remove the eyepiece without first loosening the lock collar as it can cause damage to the eyepiece and/or the spotting scope.
Fig. 2
Fig. 3a
Fig. 3b
3
EyEcUp AdjUstmEnt
The included zoom eyepiece of the Regal M2 features a twist-up eyecup to accommodate both eyeglass and non­eyeglass wearers (Fig. 4). If you do not wear eyeglasses, twist the eyecup counterclockwise until it reaches the up position. If you wear eyeglasses, make sure that the eyecup is in the down position to obtain the maximum field of view. The eyecup can be set at positions between fully up and down which may suit some users better.
chAnging thE mAgniFicAtiOn
To change the magnification of the zoom eyepiece simply rotate the eyepiece in the counterclockwise direction to increase the magnification and clockwise to decrease the magnification (Fig 5). When changing magnification the scope will need to be refocused. The largest field of view and brightest images will always be at the lowest magnification.
FOcUsing
To ensure a crisp, sharp image the spotting scope must be focused. The Regal M2 features a dual focus system that includes a course and a fine focus (Fig. 6). To focus the spotting scope, slowly rotate the course focus knob until the image in the eyepiece is clear and sharp. For fine
4
Fig. 4
Fig. 5
Fig 6
Course Focus Knob
Fine Focus Knob
adjustment slowly rotate the fine focus knob (located in front of the course focus knob) until the image in the eyepiece is clear and sharp. When the focus knob will not rotate any further, turn the wheel in the opposite direction.
ROtAting tRipOd mOUnt
The Regal M2 features a rotating tripod mount that rotates a full 360° and allows the eyepiece to be set in any viewing position. To change the position of the eyepiece, loosen the lock screw located on the tripod mount and turn the scope to the desired position (Fig 7a, 7b). Tighten the lock screw and view through the eyepiece.
lEns shAdE And sighting gUidE
The lens shade of the Regal M2 will slide away from the body to protect the lens from exposure to rain or to keep unwanted glare from entering the spotting scope and degrading your image. A sighting guide is molded into the lens shade rubber to aid in locating your subject and bringing it into the field of view (Fig. 8). The location of the sighting guide can be changed by simply rotating the lens shade.
Lock Screw
Fig. 7a
Fig. 7b
Fig. 8
5
OptiOnAl EyEpiEcEs
The Regal M2 Series spotting scopes were designed to use optional 1.25” eyepieces. Celestron offers a wide selection of 1.25” eyepieces for use on your spotting scope to achieve higher magnifications, wider fields of view, etc.
BAlAncE plAtE (FOR thE 100 mm mOdEl)
The Regal M2 100 mm spotting scope comes with a balance plate to properly balance the spotting scope when attached to a tripod (Fig. 9). To use the balance
¼”-20 Mounting Screw
plate, mount it to the tripod’s ¼”-20 mounting screw using the ¼”-20 threaded hole located on the bottom of the plate. Attach the spotting scope to the balance plate using the ¼”-20 mounting screw located on the top of the plate and thread it into the spotting scope as far as it will go. Slide the spotting scope along the slotted portion of the plate until the spotting scope is balanced on the tripod. Tighten the locking ring to hold the
¼”-20 Threaded Hole (not shown)
Locking Ring
Mounting Screw
Fig. 9
spotting scope in the desired position.
digiscOping
The Regal M2 spotting scopes can be used for digiscoping with SLR cameras and point-and-shoot digital cameras. Please note that not all cameras are compatible for digiscoping and in some cameras vignetting (a circular image surrounded by black) will occur. Point-and-shoot cameras with an optical zoom of 3x or 4x tend to be the most compatible with the least amount of vignetting. Most photographs will be the sharpest and brightest when using the lowest magnification on the zoom eyepiece.
6
slR phOtOgRAphy
To use an SLR camera and your spotting scope for photography, you will shoot through the zoom eyepiece while it is attached to the spotting scope. To prevent damage to the spotting scope, eyepiece or camera make sure the eyepiece lock collar is secure during each stage of the setup.
1. Remove the eyecup from the zoom eyepiece. With the eyecup down, rotate it counterclockwise to remove it from the eyepiece. This will expose the threads under the eyecup (Fig. 10a).
2. Thread the included T-adapter ring to the threads exposed on the eyepiece in step one above (Fig. 10b).
3. Thread an optional T-ring for your make and model of camera onto the T-adapter ring (Fig. 10c)
4. Attach your SLR camera body to the T-ring (Fig. 10d).
The Regal M2 spotting scopes have fixed apertures and as a result fixed f/ratios. To achieve the proper exposure for your photographs you need to set the shutter speed accordingly. Most cameras offer through-the-lens metering which will let you know if your picture is under or overexposed. Consult your camera manual for specific information on metering, changing shutter speeds and other settings.
Fig. 10a
Fig. 10b
Fig. 10c
Fig. 10d
7
pOint-And-shOOt phOtOgRAphy
A variety of point-and-shoot cameras can be used to digiscope with the Regal M2 spotting scopes utilizing the Universal Camera Adapter (#93626) offered by Celestron (Fig. 11). This adapter attaches to the spotting scope’s eyepiece and allows the camera lens to be centered behind the eyepiece. Please note that not all cameras are compatible with this adapter as there is not enough adjustment to center the lens behind the eyepiece when the position of the lens is low in the camera body or when the camera does not have adequate height.
WAtERpROOF / FOgpROOF
The Regal M2 Series spotting scopes are waterproof and filled with dry nitrogen gas to prevent the housing from fogging internally.
cARE And stORAgE
Your Celestron spotting scope will provide you years of dependable service if it is cared for and stored properly.
1. Protect the spotting scope from impact and do not force any of the moving parts beyond their limits.
2. Protect the optics of your spotting scope by putting on all lens caps when not in use.
3. Store your spotting scope in a cool, dry place whenever possible.
4. When storing for an extended period of time, place the spotting scope in a plastic bag or airtight container with a desiccant.
8
Fig. 11
5. Do not leave the spotting scope in a car on a hot/sunny day or near anything that generates heat as this may cause damage.
6. Clean any dust, dirt or water that may get on the spotting scope or inside moving parts as soon as possible to prevent any unforeseen damage.
clEAning
Proper lens cleaning is essential to maintaining the optical integrity of your spotting scope. Dirty lenses diminish the amount of light transmitted through the spotting scope and your overall viewing experience.
1. Remove any dust on the lenses with a soft lens brush or can of pressurized air.
2. Remove any fingerprints, stains or smudges from the lens surface with a soft, clean lens cloth or lens tissue by rubbing in a circular motion. Start in the middle of the lens and work your way to the edges. Breathe lightly on the lens to provide moisture if needed.
3. For a more thorough cleaning we recommend the use of a lens/optics cleaning kit available at most photo or optical shops. Follow the directions supplied with the cleaning kit for best results.
sERvicE And REpAiR
If warranty problems arise or repairs are necessary, contact the Celestron customer service department if you live in the United States or Canada. If you live outside of these countries, please contact the dealer you purchased your spotting scope from or the Celestron distributor in your country. A list of our distributors can be found on our website.
9
WARRAnty
Your spotting scope is covered under the Celestron Limited Lifetime Warranty. Celestron warrants the spotting scope to be free from defects in materials and workmanship for the spotting scope’s usable lifetime to the original owner. Celestron will repair or replace the spotting scope which, upon inspection by Celestron, is found to be defective in materials or workmanship and within the definitions of the limits described below.
This warranty does not cover products that have been subject to abuse, misuse, physically damaged, altered, or had unauthorized repairs or modifications. This warranty does not cover defects due to normal wear and tear and other conditions.
This warranty is valid to U.S.A. and Canadian customers who have purchased their spotting scope from an authorized Celestron dealer in the U.S.A. or Canada. For products purchased outside of the U.S.A. or Canada please contact your local Celestron Distributor or authorized Dealer for applicable warranty information. Additional warranty information and eligibility details can be found on the Celestron website.
Celestron spotting scopes are designed and intended for those 14 years of age and older. Product design and specifications are subject to change without prior notification.
For complete specifications and product information:
www.celestron.com • ©2013 Celestron • All rights reserved 2835 Columbia Street • Torrance, CA 90503 U.S.A. Telephone: 800.421.9649 • Printed in China 0113
10
TÉLESCOPE D’OBSERVATION
MODE D’EMPLOI
FRAnçAis
11
Nous vous remercions d’avoir acheté un télescope d’observation Regal M2 de Celestron. Nous espérons que ce télescope d’observation vous donnera des années de satisfaction et de loyaux services. Veuillez lire attentivement les instructions avant d’utiliser votre télescope d’observation pour vous assurer d’une utilisation adéquate.
Objectif
Ligne de visée
12
Bouton de focalisation
Pare-soleil
Support de trépied (rotatif)
(Général/détaillé)
Collier de verrouillage de l’oculaire
Vis de blocage de rotation du support de trépied
Œilleton
Oculaire
Bouchon d’objectifs
Oculaire Mont Cap
Couverture d’oculaire
T-adaptateur
AVERTISSEMENT
Ne jamais regarder le soleil pendant l’utilisation de vos télescope d’observation. Regarder vers le soleil peut causer des lésions oculaires permanentes.
AvAnt l’UtilisAtiOn
Fixez votre télescope d’observation sur un trépied robuste avant l’observation étant donné que la taille et la puissance du télescope d’observation nécessite un trépied solide pour la stabilité afin d’obtenir des images claires et nettes (Fig. 2).
FiXAtiOn dE l’OcUlAiRE
Un oculaire zoom est inclus avec le télescope d’observation Regal M2. Pour fixer l’oculaire au télescope d’observation, tournez le collier de verrouillage de l’oculaire dans le sens antihoraire jusqu’à ce qu’il soit desserré et retirez le couvercle du support oculaire. Assurez-vous que le bouchon d’objectifs soit retiré de l’oculaire et glissez-le dans le support oculaire (Fig.3a). Lorsque l’oculaire est complètement logé, tournez le collier de verrouillage dans le sens horaire pour fixer l’oculaire et le maintenir en place (Fig.3b). Ne pas essayer de fixer ou retirer l’oculaire sans avoir préalablement desserré le collier de verrouillage car cela pourrait causer des dommages à l’oculaire ou le télescope d’observation.
Fig. 2
Fig. 3a
Fig. 3b
13
RÉglAgE dE l’ŒillEtOn
L’oculaire zoom inclus du Regal M2 dispose d’un œilleton rotatif pour accueillir les porteurs de lunettes et ceux qui n’en portent pas (Fig. 4). Si vous ne portez pas de lunettes, tournez l’œilleton à gauche jusqu’à ce qu’il atteigne la position relevée. Si vous portez des lunettes, assurez­vous que l’œilleton est en position baissée pour obtenir le champ de vision maximum. L’œilleton peut être réglé dans des positions entre complètement relevée et complètement abaissée qui peut mieux convenir à certains utilisateurs.
chAngEmEnt dU gROssissEmEnt
Pour modifier le grossissement de l’oculaire zoom, il suffit de tourner l’oculaire vers la gauche pour augmenter le grossissement et vers la droite pour diminuer le grossissement (Fig. 5). Lors de la modification du grossissement, le télescope devra être refocalisé. Le plus grand champ de vision et les plus brillantes images seront toujours atteintes avec le grossissement le plus faible.
misE AU pOint
Pour vous assurer d’une image nette, la mise au point du télescope d’observation doit être effectuée. Le Regal M2 dispose d’un système de focalisation double qui inclut une focalisation générale et détaillée (Fig. 6). Pour la mise au point du télescope d’observation, faites tourner lentement 14
Fig. 4
Fig. 5
Bouton de focalisation général (course)
Fig 6
Bouton de focalisation détaillé (fine)
le bouton de focalisation général (course) jusqu’à ce que l’image dans l’oculaire soit claire et nette. Pour le réglage détaillé, faites tourner lentement le bouton de focalisation détaillé (fine) (situé en face du bouton de focalisation général) jusqu’à ce que l’image dans l’oculaire soit claire et nette.Lorsque le bouton de focalisation ne tourne plus, faites tourner le bouton dans le sens inverse.
Vis de blocage
sUppORt dE tRÉpiEd ROtAtiF
Le Regal M2 dispose d’un support de trépied rotatif qui pivote complètement à 360° et permet à l’oculaire d’être réglé dans une position de visionnement. Pour modifier la position de l’oculaire, desserrez la vis de verrouillage située sur le support de trépied et tournez le télescope à la position souhaitée (Fig. 7a, 7b). Serrez la vis de blocage et regardez à travers l’oculaire.
pARE-sOlEil Et gUidE d’OBsERvAtiOn
Le pare-soleil du Regal M2 glissera vers l’extérieur du corps pour protéger l’objectif contre la pluie ou afin d’éviter que des reflets indésirables pénètrent dans le télescope d’observation et dégradent ainsi votre image. Un guide d’observation est moulé dans le caoutchouc du pare-soleil afin d’aider à localiser votre sujet et le présenter dans votre champ de vision (Fig. 8). L’emplacement du guide d’observation peut être modifié en tournant simplement le pare-soleil.
Fig. 7a
Fig. 7b
Fig. 8
15
OcUlAiREs FAcUltAtiFs
Les télescopes d’observation de la série Regal M2 ont été conçus pour utiliser des oculaires facultatifs 1,25 po. Celestron offre un grand choix d’oculaires de 1,25 po à utiliser sur votre télescope d’observation pour obtenir des grossissements plus élevés, des champs de vision élargis, etc..
plAtEAU d’ÉQUiliBRAgE (pOUR lE mOdÈlE 100 mm)
Le télescope d’observation Regal M2 100 mm est livré avec une plaque d’équilibrage pour équilibrer correctement le télescope d’observation lorsqu’il
Vis de montage ¼ po-20
est fixé sur un trépied (Fig. 9). Pour utiliser la plaque d’équilibrage, la fixer sur la vis de fixation de ¼ po-20 à l’aide du trou fileté de ¼ po-20 situé sur la partie inférieure de la plaque. Fixez le télescope d’observation à la plaque d’équilibrage en utilisant la vis de fixation de ¼ po-20 située sur la partie supérieure de la plaque et la visser dans le télescope d’observation
Trou fileté (non illustré) ¼ po-20
Bague de verrouillage
Vis de fixation
Fig. 9 aussi loin que possible. Faites glisser le télescope d’observation le long de la partie fendue de la plaque jusqu’à ce que le télescope d’observation soit en équilibre sur le trépied. Serrez la bague de verrouillage pour maintenir le télescope d’observation dans la position désirée.
digiscOpiE
Les télescopes d’observation Regal M2 peuvent être utilisés pour la digiscopie avec les appareils reflex et appareils photo numériques compacts. Veuillez noter que ce ne sont pas toutes les caméras qui sont compatibles pour la digiscopie et que dans certains appareils photo le vignettage (une image circulaire entourée de noir) aura lieu. Les appareils photos compacts avec un zoom optique de 3x ou 4x ont tendance à être le plus compatible avec le moins de vignettage. La plupart des photographies seront les plus nettes en utilisant le plus faible grossissement sur l’oculaire zoom. 16
Loading...
+ 36 hidden pages