Cecilware GB5MF-HC-IT-LD User Manual

Page 1
1
Page 2
2
Page 3
s
s
s
A
GB5-MF-IT FACTORY GRAM THROW SET T INGS
3
FOR 8 OZ. CUP
FLAVOR COFFEE MILK
VANI LLA CARAMEL CINNAMON
5 grams 4 grams 5 grams 1.4 grams 20 grams
LATTES:
ORIGINAL0 0 07060
CARAMEL 0 135 0 70 65
CINNAMON 0 0 120 70 60
VANI LLA CARAMEL CINNAMON COFFEE MILK
5 gram
STEAMERS:
FROTHY MILK 0 0 0 0 55
Fr. VANILL
CARAMEL 0 135 0 0 55 CINNAMIN 0 0 110 0 55
CAPPUCINO'S:
ORIGINAL 0 0 0 140 60
Fr.V ANILLA 135 0 0 140 60
CARAMEL 0 135 0 140 65
CINNAMON 0 0 120 140 65
110 0 0 0 55
VANI LLA CARAMEL CINNAMON COFFEE MILK
5 grams 4grams 5 grams 2.2 grams 20 grams
4 gram
5 gram
0 grams 20 grams
9/16/2005
ADJUSTMENT RANGE :
VANILLA
CARAMEL
CINNAMON
COFFEE
MILK
Use 23.0 pts. Of drink s trength to increase 1 gram of product
Use 23.0 pts. Of drink s trength to increase 1 gram of product
Use 18.25 pts. Of drink s trength to increase 1 gram of product
Use 58.0 pts. Of drink s trength to increase 1 gram of product
Use 2.15 pts. Of drink s trength to increase 1 gram of product
NN90A-A
Page 4
s
s
A
GB5-MF-HC-IT FACT ORY GRAM T HROW SET TINGS
4
FOR 8 OZ. CUP
CAFÉ STATION
FLAVOR COFFEE MILK
VANILLA CINNAMON COFFEE COCOA MILK
ESPRESSO: VANILLA 135 0 170 0 60 MOCHA 0 0 170 100 60 CINNAMON 0 135 170 0 60 ORIGINAL 0 0 185 0 60
CAPPUCCINO: VANILLA 135 0 140 0 60 MOCH CINNAMON 0 135 140 0 60 ORIGINAL 0 0 155 0 60
COCOA: VANILLA 135 0 0 125 30 MOCHA 0 0 100 125 30 CINNAMON 0 125 0 125 30 ORIGINAL 0 0 0 150 10
4 grams 5 grams 3 grams 20 grams 20 grams
VANILLA CINNAMON COFFEE COCOA MILK
4 grams 5 gram
0 0 140 100 60
VANILLA CINNAMON COFFEE COCOA MILK
4 grams 5 grams 2 grams 40 grams 10 grams
3 grams 20 gram
12/2/2008
20 grams
ADJUSTMENT RANGE :
VANILLA CINNAMON
COFFEE
COCOA
MILK
Use 23.0 pt s. Of drink strength to inc rease 1 gram of product
Use 18.25 pt s. Of drink strength to inc rease 1 gram of product
Use 58.0 pt s. Of drink strength to inc rease 1 gram of product
Use 2.0 pt s. Of drink strength to inc rease 1 gram of product
Use 2.15 pt s. Of drink strength to inc rease 1 gram of product
NR58A-B
Page 5
5
Page 6
6
Page 7
UNPACKING INSTRUCTIONS
f
7
Carefully unpack the GB Machine and inspect immediately for shipping damage. Your GB Machine was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory. In case of damage, contact the shipper, not Cecilware.
INSTALLATION INSTRUCTIONS
Water Inlet Connection:
This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In
addition:
1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine can be moved for cleaning underneath.
2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.
The GB beverage dispenser is equipped with a 3/4" Garden Hose Connector which is located on the back of the unit.
HIGHLY RECOMMENDED:
A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/ Phosphate Filter, to remove odors
and inhibit lime and scale build up in the machine.
Note: In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the equipment and in order not to void the warranty.
After the machine has been unpacked and placed on a counter, pull out the drip tray. It should contain the following: A Set of 4 Adjustable Leveling Legs and a ¼” Flare Water Inlet Fitting.
START-UP PROCEDURE
1. Connect the ¼" dia. copper waterline to the ¼" flare water inlet fitting of the valve.
2. Plug the power cord into a proper receptacle.
3. Activate the Power Switch (Toggle Up) located on the right side of the splash panel behind the door.
The power switch controls all power to the machine including the heater elements.
The door display panel will light up and the tank will start filling.
The LCD window will display this message briefly “CECILWARE, DISPENSER V#.## “.
4. The LCD window will display this message “Low Water Level”. Allow approximately 3 to 5 minutes for the tank to fill.
If the tank does not fill up within the first 5 minutes an error message will appear in the LCD window [SYSTEM ERROR, FILL
RESPONSE].
See Definition of Screen and Troubleshooting Guide.
5. The LCD window will display this message “Low Water Temp.” Allow up to 30 minutes for the water to reach a temperature o
190°F.
The heat up time will depend on the water inlet temperature, the input voltage and the wattage of the elements in the machine.
While the tank is heating up, remove the hoppers, load them with products and reposition them back in the machine. Be sure to
reposition the hoppers so that the 1/4” pin slides into the hole of the compartment base.
When the machine has reached the proper dispensing temperature, the LCD window will display, “Press & Release to Dispense”
and “Please select choice of Drink”.
Page 8
8
WATER LEVEL CONTROLS:
Under normal conditions and operation, the water level in the tank should not drop more than ½" from the probe. If it does, the tank is not refilling fast enough. Check the water line and
Water Inlet Valve L462A Water Level Probe K402Q [K402A & P410A]
ADJUSTMENTS
water filter, they may need cleaning or replacing.
The Dispense Valves are factory adjusted for a proper Flow Rates.
[Approximate settings: 0.75 oz./sec for MILK; 0.375 oz./sec. for COFFEE and FLAVORS]
Exceeding this Flow Rate will cause the Mixing Chamber to overflow. Note: To access the Water Dispense Valves, open door and remove Hoppers. TO ADJUST WATER FLOW RATE:
1. Open door and remove hoppers. Locate Dispense Valve behind hoppers, mounted on tank.
2. Locate adjustment screw on Dispense Valve.
3
3. Using a CLOCKWISE to decrease water flow, or COUNTERCLOCKWISE to increase water flow.
4. Check water flow output, after each 1/4 turn.
" Allen Key or flat screwdriver rotate, 1/4 turn at a time,
16
WATER FLOW ADJUSTMENT
Page 9
PROGRAMMING INSTRUCTIONS
9
To access SERVICE MODE – Press simultaneously
Center of CECILWARE LOGO and Center of FAST FLOW LOGO
To access PROGRAM MODE – Press simultaneously
RINSE and STOP
To decrease or increase parameter
LCD WINDOW
TECHNOLOGY INSIDE
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
PUSH
LCD WINDOW
CLEAR
PUSH
PUSH
PUSH
PUSH
MODES OF OPERATION
1. Initializing Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main
function of this mode is to configure the system using the previously saved operating parameters.
2. Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main
functions of this mode are to monitor and report system status and control dispensing.
3. Rinse Mode – This mode becomes active when the Rinse key is depressed with any dispense key. The main function of
this mode is to allow the operator to initiate an individual Rinse for all mixing chambers.
4. Program Mode – This mode becomes active when the Rinse and the Stop keys are simultaneously depressed for more
than 1.5 seconds while in Normal Mode. The main function of this mode is to provide limited access to frequently used
system parameters. Pressing the Rinse and the Stop keys again will return the touchpad to normal mode.
5. Service Mode – This mode becomes active when the hidden keys under the “Cecilware Logo” and the “Fast Flow
Logo” are simultaneously depressed for more than 1.5 seconds while in Normal Mode. The main function of this mode is to allow access to all system parameters that can be modified. Pressing the “Cecilware Logo” and the “Fast Flow Logo”
again will return the touchpad to normal mode.
Page 10
Features and Benefits of the Digital Dispenser Controller
10
1. 100% Solid State Control for improved reliability
2. Modular design and reduced component count for ease of service
3. Optional sanitary features such as Rinse Lockouts and Rinse Warnings
4. Redundant system interlocks for uncompromising user safety
5. Large two line display for viewing system status and modifying parameters
6. Individual dispense counters and totalizers for product marketing information and inventory control
7. Advanced system diagnostics that continuously monitor the status of all motors, solenoids, sensors, and heaters
to ensure proper operation and aid in identifying potential problems
8. Protection from heater burnout due to lack of water in the reservoir tank
9. Elimination of dry powder feed at the beginning of a dispense and product dilution at the end of a dispense
10. Extremely accurate dispensing control utilizing DC servo-motor drive technology
11. Stable water temperature regulation with an adjustment resolution of one-degree Fahrenheit
12. Optional Low Water Temperature Lockout to prevent dispensing at water temperatures below an adjustable threshold
13. Units of measure displayed in either English or Metric
14. Digital adjustment of serving sizes with a resolution of one-tenth of an ounce
15. Digital adjustment of gram throw with a resolution of one-percent-of-maximum
16. Audible alarm
17. User selectable “Portion Control” or “Free Flow” dispense modes
18. Optional power saving “sleep mode” for extended periods of inactivity
19. Easy to use menu-driven dispensing and rinsing instructions
Page 11
PARAMETER DEFINITIONS FOR SYSTEM SOFTWARE
11
1. Dispense Total – This parameter indicates the total amount of water dispensed (in ounces or milliliters) for a mixing
chamber. The Dispense Total does not include Rinse Dispenses. The maximum Dispense Total value is 16,777,216
ounces; after which the value will begin again from zero. This parameter cannot be reset to zero. Default Values has no
effect on this parameter.
2. Dispense Counter – This parameter indicates the total number of cups dispensed for a selected Serving Size. The
Dispense Counter does not include Rinse Dispenses. The maximum Dispense Counter value is 49,999; after which the value will begin again from zero. In Service Mode this parameter can be reset to zero by simultaneously depressing the
and Keys. Default Values has no effect on this parameter.
3. Dispense Mode – This parameter determines whether the system dispenses in a continuous (Free Flow) or fixed size (Portion Control) method. The default setting for this parameter is Portion Control
4. Serving Size – This parameter determines the amount of water dispensed for each Dispense Key when the Dispense Mode is set to Portion Control. The default setting is 8.0 ounces. The minimum Serving Size is 2.0 ounces. The maximum Serving Size is 64.0 ounces.
5. Gram Throw – This parameter determines the ratio of product to water during a Dispense for a selected Hopper. The
units of measure for Gram Throw are proportional to Auger Turns per ounce of water. At a Fill Constant of 1.00 ounces per second the maximum Gram Throw is 100 and the minimum Gram Throw is 20. The maximum and minimum values are scaled proportional to a Fill Constant of 1.00 ounces per second. For example: if the Fill Constant is set to 1.30 ounces per second the maximum Gram Throw would be (100*1.00)/1.3 = 77. This prevents the user from requesting a Gram Throw that is beyond the capability of the Auger Motor. Auger Start and Stop Times have no effect on this
parameter. The default setting for this parameter will reset all gram throw settings to factory specs.
6. Auger Start Time – This parameter sets the time that the Auger starts to turn relative to the activation (opening) of the
Dump Valve. A positive value indicates an Auger starting at some time after the opening of the Dump Valve. A negative number indicates an Auger starting at some time before the opening of the Dump Valve. The minimum Auger Start Time =
(-3.0) seconds. The maximum Auger Start Time is 3.0 seconds. The default value for this parameter is 0.3 seconds
7. Mixer Start Time – This parameter sets the time that the Mixer starts to turn relative to the activation (opening) of the
Dump Valve. A positive value indicates a Mixer starting at some time after the opening of the Dump Valve. A negative number indicates a Mixer starting at some time before the opening of the Dump Valve. The minimum Mixer Start Time = (-
3.0) seconds. The maximum Mixer Start Time is 3.0 seconds. The default value for this parameter is 0.3 seconds.
8. Auger Stop Time – This parameter sets the time that the Auger stops turning relative to the de-activation (closing) of the
Dump Valve. A positive value indicates an Auger stopping at some time after the closing of the Dump Valve. A negative number indicates an Auger stopping at some time before the closing of the Dump Valve. The minimum Auger Stop Time =
(-3.0) seconds. The maximum Auger Stop Time is 3.0 seconds. The default value for this parameter is 0.3 seconds.
9. Mixer Stop Time – This parameter sets the time that the Mixer stops turning relative to the de-activation (closing) of the
Dump Valve. A positive value indicates a Mixer stopping at some time after the closing of the Dump Valve. A negative number indicates a Mixer stopping at some time before the closing of the Dump Valve. The minimum Mixer Stop Time = (-
3.0) seconds. The maximum Mixer Stop Time is 3.0 seconds. The default value for this parameter is 0.6 seconds.
10. Fill Constant – This parameter must be set for each of the Dump Valves. The maximum Fill Constant is 1.5 oz/sec. The
minimum Fill Constant is 0.1 oz/sec. The maximum and minimum values are scaled proportional to a Gram Throw of 100. For example: if the highest Gram Throw setting is 77 then the maximum Fill Constant would be (100*1.00)/77 = 1.30. This
prevents the user from requesting a Gram Throw that is beyond the capability of the Auger Motor. The default settings
for this parameter are 0.25 ounces per second for LEFT & MIDDLE CHAMBER, and 1.00 oz/sec For RIGHT (Milk) CHAMBER.
11. Rinse Dispense Time – This parameter determines the amount of time that the Dump Valve is open during a Rinse Cycle. The minimum Rinse Time = 3 seconds. The maximum Rinse Time is 15 seconds. The default value for this parameter is 6 seconds.
.
.
Page 12
12
12. Rinse Warning Status – This parameter determines whether the Rinse Warning Option is turned ON or OFF. If this option is ON the system generates a Rinse Warning if a Hopper has dispensed and has not been rinsed for a period of time greater than that defined by the Rinse Warning Time. Generating a Rinse Warning will cause the audible alarm to sound for two seconds and the Rinse Warning Screen to be displayed for five seconds. The system will then revert back to normal operation. If the offending Hopper is not rinsed after the first Rinse warning additional Rinse Warnings will be generated every five minutes until the respective Hopper is rinsed. The default setting for this parameter is OFF.
13. Rinse Lockout Status - This parameter determines whether the Rinse Lockout Option is turned ON or OFF. If this option is ON the system generates a Rinse Lockout if a Hopper has dispensed and has not been Rinsed for a period of time greater than that defined by the Rinse Lockout Time. Once a Hopper enters Rinse Lockout the LED’s of the Dispense Keys related to that Hopper will turn OFF thus indicating that the Hopper will no longer dispense. The default setting for
this parameter is OFF.
14. Rinse Lockout Time – This parameter determines the length of time required before entering Rinse Lockout. The minimum Rinse Lockout Time = 1 hour. The maximum Rinse Lockout Time is 12 hours. The default value for this parameter is 4 hours.
15. Water Temperature Set Point – This parameter determines the required reservoir tank water temperature. The minimum Water Temperature Set Point is 140°F. The maximum Water Temperature Set point is 203°F. The default value for this parameter is 190°F.
16. Low Water Temperature Lockout Status – This parameter determines whether the Low Water Temperature Lockout
Option is turned ON or OFF. If this option is ON the system generates a Low Water Temperature Lockout if the present water temperature is below the value defined by the Low Water Temperature Lockout Set Point. Once a Hopper enters Low Water Temperature Lockout, all of the Dispense Key LED’s will turn OFF thus indicating that the system will no longer dispense. The default setting for this parameter is OFF
.
17. Low Water Temperature Lockout Set Point – This parameter determines the minimum reservoir tank water temperature
allowed before entering Low Water Temperature Lockout. The minimum Low Water Temperature Lockout Set Point is 125°F. The maximum Low Water Temperature Lockout Set point is 203°F. The default value for this parameter is
140°F.
18. Water Level Actual – This parameter provides a readout of the water hardness level in the tank. Once provided, the water
level Setpoint can be adjusted so that the system will recognize the absence or presence of water at the level probes, thus controlling the water level.
19. Water Level Setpoint – This parameter indicates the numerical value that the “Water Level Actual” readout must be before the system allows water to fill the tank and eventually make contact with the level probes. Note: the “Water Level Setpoint must be a higher reading than the “Water Level Actual”. The default value for this parameter is 400
.
* If the “Water Level Actual” is higher than 400 then the Setpoint must be adjusted to a value 50 – 100 above the “Water
Level Actual” reading. This would be in a Hard Water condition.
* If the ”Water Level Actual is 300 or more below the default reading of 400, then the Setpoint must be adjusted to 50 – 100 above the “Water Level Actual” reading. This would be in a High Mineral content condition.
20. Sleep Mode Status – This parameter determines whether the Sleep Mode Option is turned ON or OFF. If this option is ON and the system has not dispensed for four hours the system will enter Sleep Mode. Once in Sleep Mode the system will reduce the required Water Temperature to equal that defined by (10°F + Low Water Temperature Lockout Set Point).
The default setting for this parameter is OFF
.
21. Hopper Status – This parameter determines the whether a selected Hopper is turned ON or OFF. If a Hopper is ON then
the Auger Motor, Mixer Motor, and Dump Solenoid status checking is enabled and the Hopper is allowed to dispense. If a Hopper is OFF then Auger Motor, Mixer Motor, and Dump Solenoid status checking is disabled and the LED’s of the Dispense Keys related to that Hopper will turn OFF thus indicating that the Hopper will no longer dispense. The default setting for this parameter is ON.
Page 13
22. Blower Diagnostics – This parameter will monitor the status of the blower motor and display a warning if it senses a
13
problem. The default setting for this parameter is OFF.
23. Displayed Units – This parameter determines whether the displayed units of measure are English or Metric. If the
Displayed Units parameter is set to English then all temperatures are displayed as Degrees Fahrenheit and all volumes are displayed as Fluid Ounces. If the Displayed Units parameter is set to Metric then all temperatures are displayed as Degrees Celsius and all volumes are displayed as Milliliters. The default setting for this parameter is English
24. Clock Settings – Need to set clock date (DAY, MONTH and YEAR) at the beginning life of the machine.
25. Default Values – Resets all parameters to FACTORY SETTINGS.
.
Page 14
14
Page 15
15
Page 16
16
Page 17
17
Page 18
18
Page 19
19
Page 20
SANITIZING, CLEANING AND REFILLING HOPPERS
20
Sanitizing:
To prepare a sanitizing solution: OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Always start with an unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span.
• Soak all parts for a minimum of 3 min. in the sanitizing solution.
• Let all sanitized parts drain and dry naturally. DO NOT WIPE THEM DRY.
• Before using the sanitized unit (or parts) with food stuffs, rinse all parts thoroughly with water.
Water pipe connecting and fixtures directly connected to a potable water supply shall be sized, installed, and maintained in accordance with Federal, Sate, and Local codes (section 7).
Cleaning
1. Turn the power switch to OFF.
2. Remove the drip tray with grill and empty the contents.
3. Wash and let dry the tray and grill (use a mild dishwasher detergent).
4. Wash and let dry the dispense area.
5. Turn the power switch to ON.
Cleaning the Hoppers
1. Open the cabinet door.
2. Take the hopper out of the cabinet.
3. Pull off the elbow chute and remove the hopper cover.
4. Unscrew the auger gear CW while holding steady the auger inside the hopper. Take out the auger, agitator
wheel, and spring.
5. Rinse each item thoroughly.
6. Let dry all items and reassemble.
Filling the Hoppers
1. Open the cabinet door.
2. Fill each hopper with the correct product.
3. Reposition hoppers in the hopper compartment, making sure the hoppers are properly seated.
Flushing the Whipper Chamber
Removing and Cleaning the Whipper Chambers (See Illustration)
1. Remove the dispense cap by pulling it forward and at the same time twisting it clockwise.
2. Grab and pull the mixing bowl out of the mixing bowl socket.
3. Grab and twist the whipping chamber clockwise and pull it off the mounting plate.
4. Pull the Whipper blade off the motor shaft. Notice the flat keyway on the shaft and the
matching keyway inside the Whipper blade shaft. It is important that these two keyways are lined up when re-assembling the components.
5. Twist the mounting plate clockwise and pull it off the motor shaft.
6. Slip off the o-ring from the Whipper chamber mounting plate and clean o-ring and o-ring seat.
All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first.
ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON
1. Complete Rinse is initiated by simultaneously pressing Blue Rinse Button and any Drink Dispense Buttons.
Page 21
TROUBLE SHOOTING GUIDE
21
WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact
PROBLEM PROBABLE CAUSE REMEDY
1. Light Display not
lit. No power.
2. No water when
Rinse Switch is ON.
3. No product
when Dispense Button is pressed
4. Water does not
shut off. Water keeps dispensing.
5. No water is
going into tank at all.
6. Water will not
stop flowing into tank.
7. Water is not
heating up in the water tank.
9. Water drips from
mixing chamber
a) Dispensing unit unplugged b) No power from Main Board or from Power Switch. c) Defective Bulb d) Loose Bulb in socket. e) Defective Ballast. a) Water supply OFF. b) Clogged inlet screen (Water Inlet Valve). c) Inoperative Water Inlet Valve. d) Loose electrical connection.
a) No product in Hopper. b) Auger not working. c) Damaged, loose, or missing Agitator Gear. d) Inoperative Auger Motor. e) Hopper outlet clogged f) Faulty Coupling. a) Leaking Solenoid [Water Inlet Valve]. b) Inoperative Switches on Touch Pad. c) Inoperative Rinse Switch – Touch Pad d) Clogged/stuck Water Dispense Valve
a) Water Inlet Valve malfunction.
b) Probe malfunction. a) Water Level Probe Malfunction. b) Solenoid (Water Inlet Valve) Malfunction.
a) Temperature setting is incorrect. b) Loose connection to Heating element c) Heater is burned out or defective. a) Leaking Water Dispense Valve b) Too much water in tank. c) Mixing Chamber clogged. d) Water Valve blocked by scales.
a) Reconnect dispensing unit b) Check for loose wire to Main Board or to Power Switch. c) Replace Bulb. d) Make sure bulb is seated properly in socket. e) Replace Ballast
a) Turn water ON. b) Disconnect water line and clean inlet screen. c) Check connection, if needed replace Valve. d) Check all electrical connections.
a) Add product. b) Engage Hopper/Nut to Motor Gear (see Ill. E). c) Replace Agitator Gear (see Ill. E). d) Check connections of Motor, if needed replace such components. e) Clean Hopper and check Cartridge Heater. f) Replace damaged Coupling components. a) Clean/check fittings of Valve. Replace Valve if needed. See ”Water Inlet Valve Test” b) Check Touch Pad connections. Replace Touch Pad if needed. d) Clean/unclog Water Dispense (Dump) Valve. Replace Dispense Valve if inoperative.
a) Check Solenoid valve. Replace if necessary. See “Water Inlet
Valve Test” b) Check Probe. Replace if necessary. See “Probe Test”. a) Check Probe. Replace if necessary. See “Probe Test” b) Check Solenoid. Replace if necessary. See “Water Inlet Valve
Test”
a) Set Temperature at 195°F – See Programming Instructions
b) Make sure all wires are tight. c) Replace the Heater. a) Replace Water Dispense (Dump) Valve b) Dispense some water from tank. c) Clean Mixing Chamber. d) Replace or clean Valve seat.
10. Cold drink. a) Run out of hot water b) Temperature setting is incorrect. c) Loose electrical connection.
d) Bad Heating Element or Heater is burned out.
11. Drink too
strong.
a) Water flow too low b) Product throw too high
12. Drink too weak. a) No product in hopper
b) Product throw too low c) Water flow too high
13. Drink not
whipped.
a) Whipper Blade missing. b) Loose electrical connection to motor. c) Whipper Motor defective.
a) Allow time for water in tank to heat after filling. b) Set temperature at 195°F. (See Programming Instructions) c) Check all electrical connections for contact. d) Replace Heater. (See Item 11 on Tank Assy. ILL. F).
a) Adjust water flow rate (see Ill. B) b) Adjust Gram Throw. (see Programming Instructions)
a) Add product b) Adjust Gram Throw (see Programming Instructions) c) Adjust water flow rate (see Ill. B)
a) Replace Whipper Blade b) Check electrical connections to motor. c) Replace Whipper Motor.
Page 22
14. Dispenser
22
repeats cycle
a) Touch Pad defective. b) Power [Dispense] Relay stuck.
a) Replace Touch Pad. b) Replace Relay.
15. Noise coming
from mixing chamber
16. Grinding noise
coming from unit
17. Banging or
clicking noise coming from hoppers
a) Whipper blade not properly aligned or missing.
a) Hopper not properly engaged in back, or Hopper not seated properly
a) One or more Hoppers are empty or almost empty.
a) Check blade alignment, if needed replace blade and mixing
chamber.
a) Check the mating between the auger motor’s gear and hopper’s coupling/nut. Check also pin in base. Pin must be dropped into hole in base.
a) Fill Hoppers with product.
Page 23
23
Page 24
24
Page 25
25
Page 26
26
Page 27
27
Page 28
28
Page 29
29
Page 30
30
Page 31
RECOMMENDED SPARE PARTS GB5MF-IT
31
PART No. DESCRIPTION
B138A RELAY - 120VAC (SPDT 15A) 1 25
B172A RELAY - 240VAC (SPDT 15A) 125
B176A SQUARE AXIAL FAN 120V 125
B190A SAFETY RELAY 24 VDC 125
B191A SAFETY RELAY 24VDC D.P.S.T. 125
B202A SQUARE AXIAL FAN 240V 125
B216A LAMP HOLDER 11 25
CD110 IMPELLER DISC 22 24
CD124 SLINGER DISC 33 24
CD151 AUGER MOTOR 24V DC, 97 RPM 1 1 24
CD166 BLOWER MOTOR 240V, 50/60HZ 125
CD168 WHIPPER MOTOR, SHORT SHAFT 240V, 50/60HZ 2 24
CD169 WHIPPING CHAMBER (GRAY COLOR) 2 2 24
CD173 WHIPPER MOTOR, AC 120V (SHORT SHAFT) 1 24
CD61A DISPENSE CAP 11 24
CD137 MIXING CHAMBER 11 24
CD341 GEAR MOTOR, 24V DC, 50 RPM 2 2 24
CD350 WHIPPER MOTOR, AC 120V (TWO FLATS) 1 24
CD353 WHIPPER BLADE W/ 2 FLATS 1 1 24
CD382 HOPPER, 1 3/4" W IDE W/ NYLON AUGER 2 2 24
CD385 MIXING CHAMBER (GRAY COLOR) 1 1 24
CD386 DISPENSE CAP (GRAY COLOR) 2 2 24
CD389 HOPPER, RIGHT 10 lbs 11 24
CD399 WHIPPER MOTOR, AC 240V (TWO FLATS) 1 24
CD409 DRIVE AUGER SHAFT 21MM FOR CD341 2 2 24
CD56A BLOWER 120V 125
CD63A WHIPPER CHAMBER 11 24
CD65A CHAMBER MOUNT 11 24
CD66A
CE80A BULB, FLUORESCENT 18W TWIN TUBE 240V
CE82A BULB, FLUORESCENT 18W TWIN TUBE 120V
CH246 FUSE (2 amp)
CH332 TRANSFORMER - 120V
CH474 TRANSFORMER - 240V
CH68A DOOR CABLE (6 PIN) TO INTERFACE BOARD
G266A HEATER ELEMENT, 3000W, 240W, 16" LONG
G267A HEATER ELEMENT, 1700W, 120V, 16" LONG
K402Q LIQUID LEVEL CONTROL SENSOR ASSY
L069A TOGGLE SWITCH ON/OFF SPST [POWER]
L299A TOGGLE SWITCH ON/OFF DPST [POWER]
L426A
L462A
L467A DISPENSE VALVE 120 V, 7.5W 8mm (CLEAR SEAT)
L623A
L627D CONTROL BOARD, VER 8.10, (5 Chan. for units with Ser Nos up to N689056) 1 1 25
L641G LEVEL SENSOR ASSEMBLY 11 25
L656A HI-LIMIT 200° CUTOFF 11 23
L676A DISPENSE VALVE 8mm 240 VAC 123
L736A LCD DISPLAY BOARD
L742Q
L782D CONTROL BOARD, (CONSULT FACTORY FOR PROPER VERSION #) 1 1 25
NM43G TOUCHPAD
CHAMBER MOUNT GROMMET
WATER INLET VALVE 240VAC 125
WATER INLET VALVE 120VAC 1 25
HEATER TRIAC, 35 AMP 11 23
THERMISTOR PROBE 11 23
QTY 120V
22 24
125
24 25
125
11 25
123
11 23
125
123
11 25
11 25
QTY 240V
MANUAL
PAGE #
125
125
123
125
Page 32
32
Page 33
33
Page 34
34
Page 35
35