FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
THIS INSTALLATION MUST CONFORM WITH LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE, ANSI
Z223.1 (LATEST EDITION), NATURAL GAS INSTALLATION CODE, CAN/CGA - B149.1, OR THE PROPANE
INSTALLATION CODE, CAN/CGA - B149.2 AS APPLICABLE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND
MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLATING OR SERVICING THIS EQUIPMENT.
CECILWARE CORPORATION
43-05 20th Avenue, Long Island City, N.Y. 11105 • 718-932-1414 N064A 7/99
Page 2
FOR YOUR SAFETY
Stainless Steel
FMS30
FMS40
FMS65
12 1/8 x 6 ½ x 5
hold use. Design certified for use on
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
SAFETY PRECAUTIONS
FOR YOUR SAFETY, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE FOLLOWED AND ENFORCED.
1. Instructions must be posted in a prominent location and all safety precautions taken in the event the user smells gas. Obtain this information from your local gas
supplier.
IF YOU SMELL GAS:
1. OPEN WINDOWS 3. EXTINGUISH ANY OPEN FLAMES
2. DON'T TOUCH ELECTRICAL SWITCHES 4. IMMEDIATELY CALL YOUR GAS SUPPLIER
2. LIGHTING - Follow the instructions on page 4 and on label attached to inside of fryer door.
3. Do not place anything over the flue opening.
4. Do not place combustibles or non-combustible materials in the vicinity of the fryer as this could cause fires or obstruct air to the main burners.
5. This installation must conform with local codes, or in the absence of codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition),
Natural Gas Installation Code. CAN/CGA-B 149.1, or the Propane Installation Code, CAN/CGA-B 149.2 as applicable.
6. Provide adequate air supply and ventilation.
7. Provide adequate clearance for air openings into the combustion chamber.
8. Provide clearance for servicing and proper operation. Minimum clearance from combustible construction 6" from back and 6" from side.
9. Fryer must be disconnected from gas supply during any pressure testing of pipelines in excess of 1/2 psig, and isolated (by turning off manual gas shut-off valve)
during any testing equal to or less than 1/2 psig.
10. Retain this manual for future reference.
SPECIFICATIONS
GENERAL SPECIFICATIONS
Plain Steel Tank FMP30 FMP40 FMP65
General Data
Width
Overall Depth
Working Height
Overall Height
Fat Capacity (min.)
Foam Area
Fry Area
Basket Size
Shipping Weight
Shipping Cube
Size Gas Connection ½” I.P.S.
13 ¾”
30 7/8”
34 ½”
44 ½”
30 Ibs.
12 x 22"
12x121/2”
11 1/4 x 5 1/2 x
4 170 Ib.
14cu.ft.
30 7/8"
34 ½”
44 ½”
40 Ibs.
13 ¾ x 22"
13 ¾ x 15"
200 Ib.
14cu.ft.
20"
35 ¼”
34 ½”
44 ½”
70 Ibs.
18 ¼ X 28"
18 ¼ x 19"
17 x 8 ½ x 5 ¾ "
260 Ib.
21 cu. ft.
GAS SPECIFICATIONS
Type Gas Manifold Pressure
Natural —
Propane —
Total Input
BTU/HR
Natural or Propane
This Fryer intended for other than house
combustible floor. Clearance for combustible construction 6 inches from side 6
inches from back.
80,000
3.5 in. w.c.
10.0 in w.c.
115,000
135,000
2
Page 3
SECTION A - INSTALLATION AND OPERATING INSTRUCTIONS
A1 - Unpacking - With the container upright cut the plastic straps around shipping container and lift off top, exposing the Fryer. Check Fryer for
any visible damage due to exceptionally rough handling during shipping. Report damage to the delivering Freight Carrier within 15 days of
delivery.
A2 - Accessories shipped in the vessel include:
1 - Basket Hanger
2 - Baskets
1 - Drain Pipe Extension
4 - 6 inch Adjustable Legs
A3 - Mounting of Legs or Casters - Carefully tip Fryer up on its back and screw legs or (optional) casters into the threaded base of Fryer. When
installing casters make sure the swivel lock casters are mounted towards the front of Fryer. A high strength Restrainer and Quick disconnect Gas
Connector must be installed when casters are used. Avoid putting any strain on rear legs or casters when tipping Fryer back to an upright position.
A4 - Pre-installation Instructions - The installation of your Fryer must be made by a licensed plumber and the installation must conform with Sate
and Local Codes, with the National Fuel Gas Code, ANSI Z223.1 (latest edition), Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane
Installation Code, CAN/CGA-B 149.2 as applicable.
A5 - Air Supply and Ventilation - Adequate ventilation and air supply must be provided in order for the Fryer to operate properly and efficiently.
The area in front of and above the Fryer must be clear to avoid any obstruction of flow of combustion and ventilation air. Do not, under any
circumstances, connect the Fryer flue directly to a building exhaust system or place the flue outlet directly into the plenum of the exhaust hood as it
will adversely affect the gas combustion of the Fryer.
The vent system should be of such design as to allow easy access for cleaning and degreasing on a regular basis in order to prevent fires. An
automatic fire extinguishing system should be an integral part of the vent design. Since the temperature of the flue gases emanating from Fryer
flue can reach 1200 ° F, temperature sensing devices of the automatic fire extinguishing system must be sized accordingly and located so as to
avoid premature turn-on. The minimum vertical distance from the top of Fryer flue to vent system filters should be 18 inches or more.
A6 - Clearances - Your Fryer is design certified for use on combustible floors. The minimum clearances for combustible and non-combustible
construction are as follows: 6 inches from SIDE and 6 inches from BACK. Fryer must be installed with 6 inch high legs or casters (optional). At
least 16 inches clearance must be provided between the frying surface of the Fryer and the surface flames from any adjacent cooking
equipment.
A7 - Gas Connection - Before connecting Fryer to gas line, check the rating label on inside of door panel to make sure that the gas type called for
on label coincides with the type of gas available on site. A 1/2 inch NPT gas pipe connection is provided at the rear of Fryer. An accessible manual
shut-off valve must be installed in the gas supply line ahead of the fryer for future service. The size of the supply pipe must be sized to
accommodate all the gas fired equipment that may be connected to the gas supply. Check with your local Gas Company as to proper pipe size.
Only pipe sealant resistant to action of LP. gas should be used on pipe joints. Before attempting to light fryer check joints for gas tightness using a
soap and water solution. Do not use an open flame.
A8 - Flexible Gas Connectors and Restraints (See illustration 1) - For Fryers equipped with casters, installation shall be made with a Connector
that complies with the Standard for-Connectors for movable Gas Appliances ANSI Z21.69 or CAN/CGA-6.16 and a Quick-Disconnect Device
complying with Standard for Quick-disconnect Devices for use with Gas Fuel ANSI Z21.41 or CAN1-6.9. Adequate means shall be provided to limit
the movement of Fryer to prevent undue strain on the Connector or Quick-disconnect Device. A high strength Restrainer and proper size Quickdisconnect Gas Connector conforming to above ANSI and/or CAN/CGA standards should be ordered from Fryer Manufacturer in conjunction with
NSF approved casters. If disconnection of the Restraint is necessary for servicing of Fryer, the Restraint must be reconnected after appliance has
been returned to its originally installed position.
3
Page 4
ILLUSTRATION 1 - Installation of Quick Disconnect
and High Strength Restrainer.
USER INSTRUCTIONS
IMPORTANT - DO NOT ATTEMPT TO LIGHT OR OPERATE FRYER WITHOUT THE PROPER LEVEL OF FRYING FAT (OR WATER) IN TANK,
AS SERIOUS DAMAGE WILL RESULT.
SECTION B - START UP PROCEDURE
B1 - Getting Ready to use Fryer - make sure that all the steps of Section A are completed. Verify that gas is available up to Fryer.
B2 - Filling and Draining of Fryer Tank - Close Drain Valve (red handle in horizontal position) and fill initially with water to the oil level line (hot or
cold water can be used). When draining tank allow hot content to cool to safe handling temperature.
B3 - Start-up Lighting and Operating Instructions: (See Illustration 2)
1. Turn red Thermostat Knob D counter-clockwise to its lowest or off position.
2. Partially depress and turn Control Gas Cock Dial A to "OFF" position.
3. Wait five (5) minutes to allow gas which may have accumulated in the main burner compartment to escape.
4. Turn Gas Cock Dial A to "PILOT" position.
5. Depress Gas Cock Dial A and light pilot C. Hold in depressed position for approximately 1/2 min. or until pilot remains lit when dial is
released.
NOTE: Sufficient time must be allowed for a proper size pilot flame to heat the pilot thermocouple which holds the safety magnet in a
locked-up position. Also, time must be allowed for air to escape from the lines during first operation.
6. Release Dial and turn to full "ON".
NOTE: Steps 7-13 help to check burner operation, initial thermostat calibration and clean the vessel.
7. To operate main burners rotate Red Thermostat Knob clockwise to 225° F or just above the boiling point of water.
IMPORTANT: DO NOT TURN ON MAIN BURNERS UNLESS FILLING INSTRUCTIONS WERE COMPLETED. NEVER OPERATE
FRYER WITHOUT THE PROPER LEVEL OF LIQUID (OIL OR WATER) IN VESSEL OR SERIOUS DAMAGE WILL RESULT AND
CONSEQUENTLY WILL VOID THE WARRANTY.
8. When water comes to a boil turn the Red Thermostat Knob back to 200° F. The burners should turn off.
9. If pilot becomes extinguished, repeat above procedure.
10. For stand-by periods, turn Gas Cock Dial A to "PILOT" position.
11. To shut Fryer down, partially depress and turn Gas Cock Dial A to "OFF" position and turn Thermostat to its lowest or off position.
12. Drain the vessel by means of the Drain Valve and Extension Pipe provided. Use caution when draining hot vessel.
13. Remove Extension Pipe. Wipe away any remaining water from vessel and drain. Close Drain Valve and proceed to "Normal Daily
Operation". If the latter is not convenient at this time, apply a protective coating of salt-free shortening to vessel surfaces. (Applies to FMP30 and FMP-40 Fryer with steel tanks only).
4
Page 5
SECTION C - NORMAL DAILY OPERATION
Follow this procedure after Fryer has already been started up for the first time or after Fryer has been shut down for maintenance.
C1 - Filling the Vessel for Frying: Close Drain Valve and fill to proper level (Oil level) with frying fat. If solid shortening is used, be certain
shortening is pre-melted; if not, shortening must be packed tightly around the Heat Transfer Tubes before any attempts are made to turn on Fryer.
Never attempt to melt a solid block of shortening by setting it on top of the Heat Tubes. Loosely packed solid shortening will create air voids
around Heat Transfer Tubes of Fryer. When fired up, tubes will become red hot and in turn will cause shortening to scorch and burn creating a
possible fire hazard. The safest way to melt solid shortening gradually is by turning burners "ON" for 5 seconds, then quickly "OFF" for 15
seconds. This procedure to be repeated until the tubes are covered with melted shortening. If any smoke is noticed during this melt cycle
procedure, shorten the burner "ON Cycle". Replace Crumb Screen over tubes when melted shortening has reached the "OIL LEVEL" line.
C2 - Lighting Instructions: Follow the instructions on data label attached to inside Door Panel or as outlined in Section B3 of this manual.
C3 - Fryer Operation: Set the Thermostat Knob to desired frying temperature and allow shortening to pre-heat (75° F to 350° F in 7 minutes). The
Burners are thermostatically controlled and will cycle on and off to maintain correct frying temperature. The "Safety Pilot" will remain lit until the gas
is shut off.
C4 - Special Hi-Limit Safety Control: Your fryer is equipped with an over-temperature or Hi-Limit Control which will trip and automatically shut
down the Burners should operating temperatures exceed 460° F (due to operating thermostat out of calibration or low oil level in tank). To re-set
Hi-Limit Control wait 30 minutes to allow fat to cool down or add additional cool oil or shortening for faster response; then push red pin E on HiLimit Control and relight pilot following steps (1) thru (8) in Section B3.
C5 - Shut-down and Draining: For temporary shut down turn thermostat to lowest or off position; then turn Gas Cock Dial to "PILOT" position. To
shut fryer down completely, partially depress and turn Gas Cock Dial to "OFF" position. When draining tank, allow shortening to cool to a safe
handling temperature.
ILL.2a GAS CONTROL WITH DX THERMOSTAT & BMVR VALVE
5
Page 6
SECTION D - MAINTENANCE
¾” x 36" (167,000
BTU/HR cap. @>
0-5"
W,C.
¾” x 48" (156,000
BTU/HR. Cap. @ 0
-
5"W.C,
D1 - Daily: 1) Shut down Fryer as per Section C5. Drain completely (using Drain Pipe Extension) into clean suitable container or filter pump.
2) Detach Basket Hanger Bracket, remove screen and wipe clean with cloth.
3) Flush out any remaining sediment in tank using some hot oil. Wipe off and clean fry kettle.
4) Close Drain Valve and strain shortening back into fryer using several layers of cheese cloth or filtering thru an oil pump equipped
with a Micro-Flo filtering system. Replace Crumb Screen, Basket Hanger Bracket, detach Drain Nipple and Fryer is ready for next
operation.
D2 - Weekly: Repeat daily maintenance procedure up to point (4). Close Drain Valve and clean vessel thoroughly with a deep fat fryer cleaning
compound and hot water. Drain and rinse thoroughly. Wipe dry with a clean cloth. Clean exterior stainless steel surfaces of body with stainless
steel cleaner. Do not use abrasive cleaners or steel wool.
D3 - Periodic checks: Temperature of frying compound. Set thermostat knob to 350° F. Place a fryer thermometer in fat (1 1/2 inches) and
observe reading when burner goes out. Compare reading. If the temperatures do not coincide within 5°F, have qualified service person calibrate
thermostat. See Adjustment Procedure, Section E below. Clean unit and dirt off air shutters and main burners. After long period burners and pilot
should be cleaned for proper ignition and burner flame efficiency.
D4 - Outside Service: Should you require help contact the factory, your factory representative, or your local service company.
Thermopile TP-75 F178A F178A F178A ¾” x 36" Hose with Thermal Shut-off
25
Pilot Burner Assembly (Nat.) F179Q F179Q F179Q ¾” x 48" Hose with Thermal Shut-off
Pilot Burner Assem. (Propane)
26
Magnetic Catch U008A U008A U008A Fry Tank Cover (optional) FM30
27
Thermostat Knob (KX cont.) M099A M099A M099A
Part#
FM30 FM40 FM65
V175A
F180Q F1800 F180Q Restraining Device - adjusts up to 48" (optional) P2880
Item# Description
32 Hi-Limit Control L346A L346A L346A
Gas Control (Propane) MVR L348A L348A L348A
Locking Device (Optional)
Quick Disconnect Flexible Hose (Optional):
Part#
FM30 FM40 FM65
F189A
F191A
F190A
F192A
U630Q
FM40
FM65
U5890
U641Q
Flame Shields (not shown): T776A For two tubes - side by side
T777A For one tube
6
Page 7
7
Page 8
SECTION E • ADJUSTMENTS (See Illustration 2) "FOR QUALIFIED SERVICE PERSONNEL ONLY"
A. Pilot will ignite but will not remain
1)
Loose electrical connection at Hi
-
Limit 1)
Retighten connections
C. Main Burners and Safety Pilot go out
1)
Hi-Limit Safety Switch cut
-
out due to
1)
Recalibrate Thermostat as per
D) Main Burners do not come up to full
1)
Gas pressure drop.
1)
Check gas manifold pressure by re
F. Frying temperature too high
- shortening
1)
Thermostat set too high.
1)
Check temperature of shortening and
Note: Only for qualified service personnel specializing in Hotel and Restaurant Cooking Equipment. Factory approval required prior to
any warranty repairs.
E1 - Safety Pilot: Remove Pilot Adjustment Cap (B) and turn Adjustment Screw to provide properly sized flame (3/4 inch long).
Replace Cap and leak test with Soap solution. Tighten cap if necessary.
E2 - Burners: Burners are factory set for maximum performance. Should further adjustment be required loosen Slotted Hex Screw on
side of Venturi and rotate air shutter until flame with soft blue inner cone is obtained. Remove any lint accumulated if necessary.
E3 - Thermostat Calibration: Turn thermostat knob to 375°F and remove knob without moving thermostat shaft. Place narrow
bladed screw driver (1/8") into hollow thermostat shaft and engage center adjustment screw. When thermometer reading approaches
375°F slowly turn the adjustment screw clockwise until burners go out. Turning the screw counter-clockwise will increase the
temperature. NOTE: One quarter turn will change temperature setting approximately 25 °F. Replace knob and check temperature thru
3 cycles. Repeat adjustments if necessary until knob setting is correct within a few degrees.
TROUBLE SHOOTING GUIDE - For Qualified Service Persons Only
E4 - Troubleshooting Guide
ProblemsCause Remedies
alight when Gas Cock Dial isSwitch, Gas Control Valve or(see illustrations 2 and 2a)
released.Thermostat
2) Pilot flame too low2) Relight and adjust (as per instructions
in Section E)
3) Dirt in pilot3) Remove pilot burner orifice, blow out
dirt, replace and relight pilot burner.
4) Excessive draft caused by exhaust,4) Reduce draft by regulating or diverting
air conditioner or make-up airair flow.
equipment.
5) Thermocouple defective5) Replace Thermocouple
B. Main Burners will not fire with supply1) Loose electrical connections at1) Retighten connection (see
gas valve open and incoming gasthermostat Switch or Gas Controlillustrations 2 and 2a)
present.Valve.
2. Defective thermostat Switch, Gas2) Replace in that order.
Control Valve or GS-7 hemostat.
after fryer has reached operatingout of calibration Thermostat.instructions in Section E3. If
temperature.
power, flames appear lazy. Takes too
long to reach operating
temperatures.
scorches and discolors quickly.
8
temperature is OK replace Hi-Limit
switch and light pilot.
moving Vs inch NPT Plug and
measuring pressure using U-Gauge
Manometer. With Burners on, pressure
should read 3.5" W.C. for NAT and
10.0" W.C. for PROP gas. Check
Supply line sizing. See Section A
"Gas Connection".
2) Defective or incorrect Gas Control2) Replace Gas Control Valve. (See
Valveillustrations 2 and 2a).
adjust Thermostat (as per instructions
in Section E.)
2) Shortening contaminated or of low2) Filter or strain shortening. Use higher
qualitygrade shortening.