N° Function Dip-switch Pos Description
1
Automatic
closing
ON Automatic closing activated
OFF Automatic closing disabled
2
Condominium /
step-by-step
ON During opening does not accept further commands
OFF Command : OPEN/STOP/CLOSE/STOP
3
limit switches
management
ON
During the self-calibrating the leaves don’t stop at the limit switch but
keep on moving up to the next command
OFF During the self-calibrating the leaves stop at the limit switch
4 Opening Jolt
ON Opening jolt enabled
OFF Opening jolt disabled
5
Contact safety
in opening
ON
NC contacts (15-17), stop & invert for 2 sec on opening, stop & invert
the direction on closing
OFF
NC contacts (15-17) stop the movement on opening, stops & inverts
on closing
6
Flashing
function
ON Warning light blinking
OFF Warning light xed
7 Slow down
ON slow down mode at the end of each manouvre ( opening and closing )
OFF No slow down : full torque
8
Periodic closing
command for
security
ON
Every 180 min, the panel gives a closing command, avoiding any
gate-opened situation
OFF Function disabled
9] Dip-switch settings
NOTES
• Safety edge, connected on terminals 15-17 - This contact protects opening and closing.
DIP 5 ON: When there is an obstacle, the motors stop and reverse for 2 sec.
DIP 5 OFF: When there is an obstacle motors STOP.
In both cases after the disengagement resumes the opening.
• Photocells, connected on terminals 16-17 - This contact protects only in closing : when there is an
obstacle the motors STOP;
• Emergency Stop connected on terminals 21-23 - The contact, if open, will cause the immediate stop of
the automation in any situation.
FLASHING LIGHT
If Dip6=ON then: IN OPENING: blinking slow
IN CLOSING: blinking fast
IN PAUSE: steady light
PHOTOCELL ENGAGED: Turn off