CDVI DG502U/A, DG502U/P User Manual

Edition 12/2005
Terminal
Description
B
Request-to-Exit input 1
Request-to-Exit input 2
M
Common REX inputs
R
N/C Contact door
C
Common
T
N/O Contact door
V1,V2
Varistor
ST1
Jumper for reset
S,S
Tamper Switch output
N O T I C E D E M O N T A G E E T D ’ U T I L I S A T I O N
This device comes with a varistor. The varistor must be connected to the strike terminal (electromagnet…) operated by the device. If this product works with many strikes, each of them should have a varistor. The varistor controls the overload produced by the strike coil – self-effect.
If you are using a « Shear Lock » electromagnetic lock, it is recommended to use a separate power supply than the one connected to the DG502U!
Warning
Do not use a switching power supply because of the interference radiation that may disturb the reading of the badges
PB1
PB2
CRTRCTSSBME12345612V
12
123
456
789
0
#
RL1
RL2
12 3
ST1
V1
strike
Input voltage
12VAC/DC
V
M A G N E
V2
DG502U/A DG502U/P
2-DOOR CONTROLLER
500 USERS
Edition 12/2005
- 2 -
2
Technical specifications
Input voltage
12 VAC/DC
Outputs
2 form C relays N/O and N/C 3A @ 125V
Tamper switch
500 MA @ 50 VAC/DC
Cardholders
500 badges
Master code
5-digit master code
Inputs
2 REX inputs
Controller
12-digit keypad with built-in buzzer (Audible feedback)
Distance between the remote readers and the controller
60 cm minimum, 50 meters maximum (cable spec. 7 x 0.6 mm2)
Default Factory Values
Master Code: 12345 Door release time: 1 second Key-in Keypad: 10 seconds Enrollment unit: Built-in reader in controller
Power consumption
DG502 only: 160mA DG502 with 1 remote reader: 240mA DG502 with 2 remote readers: 320mA
Audible Feedback
1 long beep
Validation of data in programming mode: master code, proximity badge or time delay.
Or access code validated
2 short beeps
Accessing the programming mode
or exit from the programming mode
4 short beeps
Badge not programmed (invalid badge)
or incorrect master code or time delay entered
Visual Feedback
LED
Stand-by mode
Programming mode
Green
Door relay activated
User location free
Red
Alarm activated
User location
orange
Programming mode
orange flashing
Stand-by
Error data computing
Request-to-Exit Inputs
The two request-to-exit inputs PB1 and PB2 operate relay RL1 and RL2. The LED turns on green when the relay is activated by one of the two inputs.
Edition 12/2005
- 3 -
3
Changing the Master Code
1. Enter the master code twice (for the first use the master code default value is 12345). 2 beeps and the orange LED lights on confirming that you are in programming mode.
2. Enter *3 then the 5-digit new master code. The LED goes off during 1 second and an audible beep indicates that the new master code is memorised.
3. Press # to exit from the programming mode. 2 beeps confirm that you went back to the reading mode.
4 beeps indicate a data computing error.
Time outputs, Enrolment Reader and Access Level
Enter the master code twice (for the first use the master code default value is
12345). 2 beeps and the orange LED lights on confirm the entry in programming
mode.
Enrolment reader (* mag stripe must be set as remote enrolment reader)
Enter 0, then 00 to select the built-in reader of the controller as the enrolment unit. *Press 0, then 01 remote reader 1 as the enrollment unit. The LED lights off during 1 second and an audible beep indicates the validation of the enrolment reader. In stand-by mode, if the enrolment reader is the controller built-in reader all the readers can be used but if the enrolment reader is the remote reader 1 then only the 2 remote reader can be used.
Time output relay 1
Enter 1, then the time relay in second: 01 equal 1 second up to 99 for 99 seconds. 00 corresponds to a latched output. The LED lights off during 1 second and an audible beep indicates the validation of the time delay.
Time output relay 2
Enter 2, then the time relay in second: 01 equal 1 second up to 99 for 99 seconds. 00 corresponds to a latched output. The LED lights off during 1 second and an audible beep indicates the validation of the time delay.
Access Level
Enter 4 , then 01 for door 1 and controller activates relay 1
02 for door 2 activates relay 2 03 door 1 and 2 activates relay 1 2
The LED lights off during 1 second and an audible beep indicates the validation of the access level.
Press # to exit from the programming mode. 2 beeps confirm that you returned to reading mode.
4 beeps indicate a data computing error.