CDVI CDV-91 User Manual

2 -Wire Intercom System
USER MANUAL
Model: CDV-91
-1-
1.Parts and Functions
Rainy Cover
Night View LED
Speaker
Nameplate
Call Button
Microphone
90 mm
176 mm
23 mm
2.Terminal Descriptions
BUS
PL
S1+ S2+ S-
1 2
ON
12
ON
MIC adjustment
Lock Control Jumper
Doorstation Code DIP
Main Connect Port
1 2 3
SPK adjustment
-2-
Lock Control Jumper:
To select the lock type: see 5.2.1 , 5.2.2
Door Station Code DIP:
Total 4 door stations can be supported,see 6.1
Main Connect Port:
To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
PL: External lock power input, connect to the power positive(power +).
S1+, S2+: Lock power(+) output, to connect 2 locks.
S-: Lock power(-) output, connect to the power(-) input of locks.
3.Specications
Power Supply : DC 24V (supplied by PS1-24V or PS5-24V)
Power Consumption: Standby 50mA; Working status 200mA
Camera: Pinhole Sharp Color CCD; 420 TV Lines
Unlocking time: 1-9S, set by monitor
Lock Power supply: 12Vdc, 300mA(Internal Power)
Temperature: -100C~+450C
Wiring: 2 wires (non-polarity)
Dimension: 176(H)×90(W)×24(D)mm
4.Mounting
4.1 Mounting Without Rainy Cover
160-165cm
1
2
1 2 3 4
-3-
4.2 Mounting With Rainy Cover
160-165cm
1
2
1 2 3 4
4.3 Placing Name Label
Move the plastic cover away to open the transparent name label cover, insert a name paper, then put the plastic cover back to the panel.
name label
12
ON
Loading...
+ 11 hidden pages