CDVI CD97-4ID, CDV17-97A User Manual

USER MANUAL
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
RF CARD
RF CARD
2 WIRE SYSTEM
CDV97 Series
CD97-4ID CDV17-97A
CDV-ENG-97-V1 / 201608
CONTENTS
PARTS AND FUNCTIONS ..................................................................................... 3
Part Names............................................................................................................. 3
Mounting ................................................................................................................. 4
BASIC FUNCTIONS .............................................................................................. 6
Unlock Operations .................................................................................................. 6
Fisheye Camera ..................................................................................................... 6
External Motion Detection ...................................................................................... 6
SETUP INSTRUCTIONS ........................................................................................ 7
Functions Setting Up .............................................................................................. 7
Setting Door Station Address .................................................................................8
Setting Door Station Calling Mode ......................................................................... 8
Setting Camera Resolution.................................................................................... 10
Setting Unlock Mode ............................................................................................. 10
Setting Unlock Time............................................................................................... 11
Setting Nameplate Illumination Mode .................................................................... 11
Setting Night View LED Illumination Mode ............................................................ 12
Setting Ring-back Tone ......................................................................................... 12
Setting Image Display Mode.................................................................................. 13
Registering ID Card ............................................................................................... 14
WIRING ................................................................................................................. 17
Connecting Electric Lock ....................................................................................... 17
Connecting Basic One-to-one ............................................................................... 18
Connecting Multi Door Stations ............................................................................. 18
Connecting Multi Monitors ..................................................................................... 19
APPENDIX ............................................................................................................ 21
Precautions............................................................................................................ 21
Specication .......................................................................................................... 21
Cables and Requirments ....................................................................................... 22
-3-
Part Names
PARTS AND FUNCTIONS
[11]
[10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
[14] Mounting box
-4-
PARTS AND FUNCTIONS
Mounting
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
≥3mm
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Surface mounted
The installation height is suggested to 145~160cm.
* The camera angle view of surface mount model may be less than 1700.
Rain cover
Main Unit
1 2 3 4 5
The distance between the top of main unit and rain cover should be not less than 3mm.
Main unit
Rain cover
1. Drill holes in the wall to match the size of wall plugs, then attach the rain cover and main unit to the wall, the distance between the top of main unit and rain cover should be not less than 3mm.
2. Connect the cable correctly to the Bus terminals.
3. Install the name plate.
4. Attach the front panel to the main unit.
5. Use the Torx key (provided) tot the front panel.
-5-
PARTS AND FUNCTIONS
Terminal description
Lock Control Jumper:
To select the lock type.
Main Connect Port:
To connect the bus line and the electronic locks.
L1,L2: Connect to the bus line, no polarity.
1 2 3
Lock Control Jumper
PIR Motion Detector Connect Port
+12V
GND
PIR
L1
L2
PL
S+
S-
Main Connect Port
Motion Detector Connection Port:
To connect external PIR motion detector.
PL: External lock power input, connect to the PSU positive (lock control jumper removed).
S+: Lock positive(+) output.
S-: Lock negative(-) output, connect to the negative (-) connection of the lock (only when
using the door station to power the lock. When using an external PSU S- will not be connected).
-6-
BASIC FUNCTIONS
Fisheye Camera
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector.
Standard
door station angle
1700 door camera angle
(Wide angle view shown)
12V
Motion
detector
GND
PIR
* Please contact with supplier for more details about detector connection.
Unlock Operation
Unlocking by Card/Tag
When a registered user card/tag is presented to the ID card window, the UNLOCK
indicator lights up, a single beep will be heard and the lock relay will activate.
If an unauthorised user card/tag is presented, three beeps will be heard and the lock relay will NOT activate.
Please note that this function requires a
monitor with sh-eye function to support.
T
he angle of view is 170
0
, visitors within this
angle
can be seen clearly the image can then
be zoomed to see individuals up close
CDV97-4ID
If an external motion detector is connected
to the door station the following functions will
be active:
If someone is detected at the door or passing
by, the door station can be set to activate
the unlock function or turn on a light.
-7-
SETUP INSTRUCTIONS
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
RF CARD
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2
Setting door station
calling mode
Standard/Group calling mode Standard calling mode
3 Setting camera resolution High/Low High
6
Setting the nameplate
illumination mode
On/Off/Auto On
7
Setting night view LED
Zoom mode
Full screen mode
Alternate switching mode
This section explains the settings of each
function, please refer to the table below:
Each operation is indicated by the LED
indicator and the buzzer on the unit,
5 Setting the unlock time 01 to 99 seconds 1 seconds
4 Setting the unlock mode 0 = Opened/1 = Closed 0 = Opened
On/Off/Auto Auto
illumination mode
Alternate switching mode
9 Setting image display mode
Ring Once
Ring Continuous
No ring-back tone
Function Programming
To carry out programming of the function
required, the metal front panel must be
removed. Please refer to Fig 1.
-8-
Setting Door Station Address
Setting Door Station Calling Mode
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+, Beep
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+
In standby mode, press KEY_SET button once
Press KEY_1 button to set the first door station.
Press KEY_2 button to set the second door station.
Press KEY_3 button to set the third door station.
Press KEY_4 button to set the fourth door station.
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep,Beep
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep,Beep,Beep
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
PROGRAMMING INSTRUCTIONS
A total of 4 addresses can be congured. Addresses can be modied either before or
after installation. 0 is default, to change the setting, please follow the steps:
If still in programming mode, addresses can still be changed by pressing KEY1~4 freely.
There are two call modes for the door station, Standard calling mode and Group calling
mode. Please note that the door station is set to Standard calling mode by default.
The LED_NAME indicator will always flash while in programming mode.
If there is no operation within 10 seconds, the door station will exit programming mode automatically.
To exit programming mode, press KEY_SET button four times to exit manually.