CDIDI CDLL4150, CDLL3600, 1N4150UR-1, 1N3600UR Datasheet

MILLIMETERS INCHES
DIM MIN MAX MIN MAX
D 1.60 1.70 0.063 0.067 F 0.41 0.55 0.016 0.022 G 3.30 3.70 .130 .146
G1 2.54 REF. .100 REF.
S 0.03 MIN. .001 MIN.
22 COREY STREET, MELROSE, MASSACHUSETTS 02176 PHONE (781) 665-1071 FAX (781) 665-7379 WEBSITE: http://www.cdi-diodes.com E-mail: mail@cdi-diodes.com
• 1N4150UR-1 AVAILABLE IN
JAN, JANTX,
AND
JANTXV
PER MIL-PRF-19500/231
• SWITCHING DIODE
• HERMETICALLY SEALED
• METALLURGICALLY BONDED
• DOUBLE PLUG CONSTRUCTION
FIGURE 1
DESIGN DATA
CASE: DO-213AA, Hermetically sealed
glass case. (MELF, SOD-80; LL34)
LEAD FINISH: Tin / Lead
THERMAL RESISTANCE (R
O
JEC
):
100 °C/W maximum AT L = 0
THERMAL IMPEDANCE: (Z
O
JX
): 70
˚C/W maximum
POLARITY: Cathode end is banded.
MOUNTING SURFACE SELECTION:
The Axial Coefficient of Expansion (COE) Of this Device is Approximately +6PPM/°C. The COE of the Mounting Surface System Should Be Selected To Provide A Suitable Match With This Device.
1N4150UR-1
1N3600UR
CDLL4150 CDLL3600
V
F1
V
F2
V
F3
V
F4
V
F5
Limits I F= 1 mA dc I F= 10 mA dc I F= 50 mA dc I F= 100 mA dc I F= 200 mA dc
(Pulsed) (Pulsed) (Pulsed)
V dc V dc V dc V dc V dc
minimum 0.540 0.680 0.780 0.820 0.870
maximum 0.620 0.740 0.860 0.920 1.000
Type V
BR
V
RWM
I
R1
1
R2
Ct
rr
VR= 50 V dc VR= 50 V dc VR= 0; f = 1 Mhz; IF= IR= 10 to 100 mAdc
IR= 10
µA T
A
= 25°C TA= 150°C ac signals = 50 m V (p-p) R L= 100 ohms
V dc V (pk) µA dc µA dc pF ns
CDLL3600 75 50 0.1 100 2.5 4 CDLL4150,-1 75 50 0.1 100 2.5 4
MAXIMUM RATINGS
Junction Temperature: -65°C to +175°C Storage Temperature: -65°C to +175°C Operating Current: 300 mA @ TA= + 25°C Derating: 3.1 mA dc/°C Above T
EC
= + 110°C
Forward Surge Current: 4A, (tp = 1µs); 0.5A (tp = 1s)
ELECTRICAL CHARACTERISTICS @ 25°C, unless otherwise specified.
FORWARD VOL T AGE LIMITS – ALL TYPES
IN4150UR-1, IN3600UR-1, CDLL4150 and CDLL3600
.3 .4 .5 .6 .7 .8 .9 1.0 1.1 1.2 1.3
VF - Forward Voltage (V)
FIGURE 2
Typical Forward Current
vs Forward Voltage
I
F
- Forward Current - (mA)
1000
100
10
1
0.1
150ºC
100ºC
25ºC
-65ºC
20 40 60 80 100 120 140
Percent of Reverse Working Voltage (%)
FIGURE 3
Typical Reverse Current
vs Reverse Voltage
I
R
- Reverse Current - (µA)
1000
100
10
1
0.1
.01
.001
150ºC
100ºC
25ºC
-65ºC
NOTE : All temperatures shown on graphs are
junction temperatures
Loading...