CDIDI 1N4148-1 Datasheet

22 COREY STREET, MELROSE, MASSACHUSETTS 02176 PHONE (781) 665-1071 FAX (781) 665-7379 WEBSITE: http://www.cdi-diodes.com E-mail: mail@cdi-diodes.com
1N4148-1
I
R1
I
R2
I
R3
I
R4 CAPACITANCE CAPACITANCE
@ 20 V dc @ 75 V dc @ 20 V @ 75 V @ 0 V @ 1.5 V
TA= 150°C TA= 150°C
nA µA µA µA pF pF
25 0.5 35 75 4.0 2.8
FIGURE 1
DESIGN DATA
CASE: Hermetically sealed
glass case per MIL-S-19500/116 D0-35 outline
LEAD MATERIAL: Copper clad steel. LEAD FINISH: Tin / Lead
THERMAL RESISTANCE: (R
O
JL
):
250 ˚C/W maximum at L = .375 THERMAL IMPEDANCE: (Z
O
JX
): 70
˚C/W maximum
POLARITY: Cathode end is banded.
MOUNTING POSITION: Any.
V
f 1
V
f 2
t
rr
V
BR
V
RWM
I
0@
I F = 10 mA@I F = 100 mA
@100µA
Volts Volts (pk) mA V dc V dc n sec
100 75 200 0.8 1.2 5
MAXIMUM RATINGS
Operating Temperature: -65°C to +200°C Storage Temperature: -65°C to +200°C Operating Current: 200 mA @ TA= +25°C Derating Factor: 1.14 mA/°C Above TA= + 25°C Surge Current A: 2A, sine wave, Pw= 8.3ms Surge Current B: 1.41A, square wave, Pw= 8.3ms
ELECTRICAL CHARACTERISTICS @ 25°C, unless otherwise specified.
• 1N4148-1 AVAILABLE IN
JAN, JANTX,
AND
JANTXV
PER MIL-PRF-19500/116
• SWITCHING DIODE
• HERMETICALLY SEALED
• METALLURGICALLY BONDED
• DOUBLE PLUG CONSTRUCTION
IN4148-1
.3 .4 .5 .6 .7 .8 .9 1.0 1.1 1.2 1.3
VF - Forward Voltage (V)
FIGURE 2
Typical Forward Current
vs Forward Voltage
I
F
- Forward Current - (mA)
1000
100
10
1
0.1
150ºC
100ºC
25ºC
-65ºC
20 40 60 80 100 120 140
Percent of Reverse Working Voltage (%)
FIGURE 3
Typical Reverse Current
vs Reverse Voltage
I
R
- Reverse Current - (µA)
1000
100
10
1
0.1
.01
.001
150ºC
100ºC
25ºC
-65ºC
NOTE : All temperatures shown on graphs are
junction temperatures