Selects a desired radio wave and changes it to the video IF signal.
2 — Video IF Amp.: Q200 2SC4670
Amplifies the video IF signal output from the tuner TU by 10 times (20 dB).
3 — Video Det./Sound Det./FM Det./AFT/AGC: IC200 M51348FP
Eliminates the carrier wave in the video IF signal, and picks up the video signal and the sound IF signal.
Also, the sound signal is picked up from the sound IF signal by FM detection.
4 — Audio Amp.: IC600 NJM2070M
Sound amplification.
5 — Chroma Circuit: IC300 IR3P90B
Generates the tricolor (red, green, and blue) from the video signal.
6 — Display Control/ Auto-Tuning Control : IC700 MSM6770GS
Controls the display.
7 — Tuning Voltage Generator: IC270 BA10358F
Generates the tuning voltage with the tuning pulse (TU) output from 6.
— 2 —
ADJUSTMENT
LINEAR PCB
Items To Be Adjusted
ItemMeasuring Instrument
VCC2-1 voltage settingVoltmeter
Video detection coil adjustmentTV signal generator, pattern generator, oscilloscope,
low-pass filter
AFT coil adjustmentSweep generator, oscilloscope, voltmeter
Contrast adjustmentTV signal generator, pattern generator, oscilloscope
AGC adjustmentTV signal generator, pattern generator, IF levelmeter
Clock adjustmentVoltmeter
Adjustment And Test Point Locations
T201
T200
Top View
— 3 —
Pad IF
TP2
TP7
VR204
TP5
TP8
TP3
TP6
VR748
VR325
VR308
VR330
Bottom View
TP4
VR311
VR301
TP1
VR100
Equipment Connection / Adjustment Procedure
VCC2-1 Voltage Setting
TV-5100
Set
Output
TP1
InputInputInputOutputOutput
Connection PointSignalConnectionPoint
AdjustResult
VR100
Voltmeter
Voltmeter
TP1
Adjust for 4.50 ± 0.02 V
reading on voltmeter.
— 4 —
* Open soldering pad IF.
Pattern
generator
Signal
generator
Video Detection Coil Adjustment
TV-5100
Set
InputOutput
TP2
TP3
Oscilloscope
Low-pass
filter
InputInputInputOutputOutput
Connection PointSignalConnectionPoint
AdjustResult
Pattern
generator
Signal
generator
TP2T200TP3
Color bar
45.75 MHz
45 ± 3 dBµ
Low-pass filter
Oscilloscope
AFT Coil Adjustment
* Open soldering pad IF.
Sweep
generator
Input
TP2
TV-5100
Set
OscilloscopeVoltmeter
Output
TP4
45.75±5 MHz
Sweep
generator
(Sweep) Marker:
TP2T201TP4
45.75 MHz
Voltmeter
Oscilloscope
70 dBµ
Adjust for DC level at mini-
Adjust for 1.4 ± 0.2 V reading
on voltmeter.
Confirm that the marker is at
the middle of S-curve on oscilloscope.
* Open soldering pad IF.
Pattern
generator
Pattern
generator
Signal
TP2VR301TP5
Color bar
45.75 MHz
70 dBµ
generator
Contrast Adjustment
Signal
generator
Input
TP2
Oscilloscope
— 5 —
TV-5100
Set
VCC2-3(5V)
10 kohm
Oscilloscope
CP302
Output
TP5
Adjust step form wave to read
2.5 ± 0.1 Vp-p.
* Open soldering pad IF.
Pattern
generator
Signal
generator
Color Adjustment
TV-5100
Set
Oscilloscope
Input
TP2
InputInputInputOutputOutput
Connection PointSignalConnectionPoint
Pattern
generator
Signal
TP2VR311OscilloscopeTP5
Color bar
45.75 MHz
70 dBµ
AdjustResult
generator
Tint Adjustment
* Open soldering pad IF.
Pattern
generator
Signal
generator
TV-5100
Set
Input
TP2
Output
TP5
Adjust VR311 so that the
difference
between pulse
A and B is less
than 0.1V.
Oscilloscope
Output
TP5
Pulse BPulse A
Pattern
generator
Signal
generator
Pattern
generator
Pattern
generator
TV Signal
generator
Color bar
45.75 MHz
TP2VR325 OscilloscopeTP5
70 dBµ
AGC Adjustment
Signal
generator
TV-5100
Set
Input
TP7
Color bar
TP7VR204 IF levelmeterTP2
65 ± 5 dBµ
Adjust VR325 so that the
difference
between pulse
A and B is less
than 0.1V.
IF levelmeter
Output
TP2
Adjust for 84 ±1 dBµ
reading on the IF levelmeter
Pulse BPulse A
— 6 —
Vcom Adjustment
TV-5100
Set
Oscilloscope
Output
TP8
InputInputInputOutputOutput
Connection PointSignalConnectionPoint
AdjustResult
VR328
OscilloscopeTP8
VR330
* Place a photo diode on the middle of the display plate.
Photo senser amp.
TV-5100
Set
Photo
diode
ON
OFF
Band-pass
H
M
L
filter
Adjust VR328 so that squarewave to read 6.0 ±0.1V.
Adjust VR330 so that high level
of the square-wave is at 0.0
±0.25V.
Oscilloscope
AV-C1
Photo sensor
amp.
VR330
Band pass filter
Oscilloscope
Free-running Frequency Adjustment
TV-5100
Set
Frequency
Counter
Output
TP6
VR748TP6
Frequency
Counter
Adjust for ripple at minimum.
Adjust for a reading of 15.73 ±
0.01 KHz.
— 7 —
TOP VIEWS
Linear
PRINTED CIRCUIT BOARDS
JK200
T
C210
SW
100
FU
100
JK100
C300
R736
C160
C202
C302
C150
F203
R734
C162
T100
T
C319C304
R729
R739
C771
C336
C110
T201
R728
R737
R741
C774
C112
T200
R727
C772
L102
R740
R761
IC701
C373
C156
C116
C207
C246
F202
OM-675
R760
C603
R222
R717
IC700
+
H300
C215
TU200
C208
C787
C781
R342
F201
L756
C786
R756
R208
R718
R714
R704
C788
JK250
F200
L201
C242
CN700
R757
VR640
VR343
BL
D180
C100
C130
C120
L101
C925L950
C118
— 8 —
C606
C114
T950
C600
R601
C927
R600
JK600
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.