ENGLISH
Day of the week
PM
Hour
Timekeeping Mode
A sticker is affixed to the glass of this stopwatch when you purchase it. Be sure to remove the sticker before using the stopwatch.
Depending on its model, the configuration of your stopwatch may differ somewhat from that shown in the illustration.
OPERATING PRECAUTIONS
A battery is installed at the factory. Have it replaced by a CASIO distributor at the first sign of low power (dim display).
Do not use or store this stopwatch in areas exposed to temperature extremes, strong magnetism, strong vibration, or strong impact.
Heat can shorten battery life and cause malfunction. Keep the stopwatch away from heaters and direct sunlight when using it.
Never try to take the stopwatch apart. Doing so can cause malfunction.
To clean the stopwatch, use a soft, dry cloth or a cloth moistened in a solution of water and a mild neutral
detergent. Wring out all excess moisture from the cloth. Never use thinner, benzene, alcohol or other similar agents.
Be sure to keep all user documentation handy for future reference.
CASIO COMPUTER CO., LTD. assumes no responsibility for any loss, or any claims by third parties that may arise through the use of this stopwatch.
GENERAL GUIDE
C button .... Starts and stops timing.
B button .... Toggles between the current time and stopwatch screens.
A button ..... Performs lap/split and reset operation (stopwatch beeps).
R button ..... Recalls lap/split time records and total elapsed time.
SPLIT TIME AND LAP TIME
Split time (SPLIT) is the time elapsed from the start to a specific point.
Lap time (LAP) is the time elapsed from one point to another or for one lap around a track.
USING THE STOPWATCH
The stopwatch beeps to signal C and A button operations.
Working range
The total elapsed time and split time display is limited to 9 hours 59 minutes 59.999 seconds. Lap time display is limited to 59 minutes 59.999 seconds. Thereafter it will be reset and started again. The lap counter starts from 1 to 99 and repeats from 0. While the stopwatch is reset to all zeros, holding down the A button will toggle the lower display area between display of lap time and split time.
100 (indicating the number of laps) will flash on the display when memory is full (100 lap times in the current group).
NORMAL TIME
CHART
BUTTON OPERATION
DISPLAY
NET TIME
CHART
BUTTON OPERATION
DISPLAY
After stopping a net time operation by pressing C, you can resume it by pressing C again.
Time Display Stopwatch Display
Lap counter Split time
Year
Month Day
Hours
Minute
Stopwatch Mode
Press . Press .
1ST SPLIT
START
1ST LAP
START
START STOP RESET
0
START STOP START STOP RESET
0
(a)
a
(a) (a) (a + b)
ab
(Stoppage time)
2ND SPLIT
Minutes
2ND LAP
Seconds
1/1000th of a second
Recall Mode
3RD SPLIT
3RD LAP
Lap time
Total elapsed time
LAP/SPLIT TIMES
START STOP RESET
1ST LAP 2ND LAP 3RD LAP
CHART
BUTTON OPERATION
0
1ST SPLIT (a
a
(a)
b
)
2ND SPLIT (a+b
(a + b)c(a + b + c) (t)
)
3RD SPLIT (a+b+c
)
DISPLAY
MULTIPLE FINISHING TIMES
Example : To record the times of 100 different runners.
RESET
CHART
BUTTON OPERATION
START 1ST
RUNNER
FINISHES
2ND
RUNNER
FINISHES
99TH
RUNNER
FINISHES
Difference between current finisher and previous finisher
100TH
RUNNER
FINISHES
DISPLAY
Finishing position
USING THE RECALL MODE
You can use the recall mode to view data in stopwatch memory.
There is enough memory to store a total of up to 200 records, divided between two record groups of 100 each. If you record 100 times, the 100th time will not be stored in memory until you reset the stopwatch to all zeros.
Starting a new stopwatch elapsed time operation will cause the older of the two record groups to be deleted automatically in order to make room for a new group of records.
There is also a FAST LAP record that displays the fastest lap from among all of the lap times currently in memory.
Record 1 (the newest record) will always be displayed first whenever you press the R button to switch from the
Stopwatch Mode to the Recall Mode. In the Recall Mode, each press of the B button will toggle the display between record group 1 and record group 2.
Lap time records in memory can be recalled while an elapsed time operation is in progress or stopped.
Memory records are cleared whenever a new Stopwatch Mode elapsed time operation is stared by pressing the
C button after pressing the A button to reset the stopwatch to all zeros.
Holding down the or button scrolls at high speed.
SETTING THE CURRENT TIME AND DATE
MUTE
Beeper On/Off
In the Timekeeping Mode, hold down the A button for about two seconds to toggle the beeper on or off.
Auto Return
The stopwatch returns to the Timekeeping Mode if left unused for a few minutes.
1. In the Timekeeping Mode, hold down R for about two seconds.
2. Press C on a time signal to correct the seconds.
3. Flashing setting can be changed. Press B to move the flashing.
SECONDS HOUR MINUTES YEAR
MONTHDAY
4. Use C (+) and A (–) to change the flashing setting.
Holding down the C or A button scrolls at high speed.
5. Press R to exit the setting mode.
Year digits can be set up to the year 2099.
*
12/24-hour Timekeeping
In the Timekeeping Mode, press C to toggle between 12-hour and 24-hour timekeeping.
CARE OF YOUR STOPWATCH
This stopwatch is water resistant up to five bars (atmospheres), which means you can use it in the rain or in areas where splashing water is present. Never, however, operate the buttons of the stopwatch while it is immersed in water.
You should have the rubber seal that keeps out water and dust replaced every 2 to 3 years.
Should moisture appear inside the stopwatch, have it checked immediately by your dealer or a CASIO distributor.
SPECIFICATIONS
Accuracy at a normal temperature (TIME): ±30 seconds per month
Display capacity:
Time Display: Hour, minutes, seconds, am/pm, year, month, day and day of the week Calendar system: Pre-programmed until the year 2099
Stopwatch Display: Measuring capacity: (Total elapsed time display) 9 hours 59 minutes 59.999 seconds
Measuring unit: 1/1000 second Measuring modes: Net time, lap time, split time, 1st-100th place time, lap counter (up to 99) Memory capacity: 2 sets of 100 records each
Battery: One lithium battery (type: CR2032)
Approx. 5 years continuous operation on type CR2032 (includes an average of 30 presses of button per day.)
Operating Temperature: 0°C to 40°C (32°F to 104°F)
(STOPWATCH): 99.9988%
(Lap time display) 59 minutes 59.999 seconds (Split time display) 9 hours 59 minutes 59.999 seconds