Casio 5244 Operation Guide

Casio 5244 Operation Guide

MA1106-EA

Operation Guide 5244

••Your watch may differ somewhat from the one shown in the illustration.

Hour hand

Minute hand

First click (Setting Day)

Second click (Setting Time)

Crown

(Normal position)

Day

Second hand

To set the time

1.When the second hand is at 12 o’clock, pull out the crown to the second click to stop it.

2.Set the hands by rotating the crown. Rotate the crown to move the hands clockwise. Move the minute hand four or five minutes past the time you want to set, and then back it up to the proper setting.

3.Push the crown back in to the normal position to restart timekeeping.

To set the day

1.Pull the crown out to the first click.

2.Set the day by rotating the crown.

3. Push the crown back in to the normal position.

••Avoid changing the date setting while the current time is between 9:00 p.m. and 1:00 a.m.

Using the Stopwatch

 

Stopwatch 1/20 second hand

 

* This hand rotates and

Stopwatch minute hand

indicates the second count

during the first 30 seconds.

 

Stopwatch second hand

 

The stopwatch lets you measure elapsed time up to 59 minutes, 59.95 seconds.

To measure elapsed time (First 30 seconds)

1.Press A to start the stopwatch.

2.Press A to stop the stopwatch.

••You can resume the measurement operation by pressing A again.

3.Check the elapsed time.

••The example below shows an elapsed time of 24.65 seconds.

Stopwatch 1/20 second hand

[.65]

Stopwatch second hand [24 seconds]

••Press B to reset the stopwatch. This will enter the Timekeeping Mode.

To measure elapsed time (After the first 30 seconds)

1.Press A to start the stopwatch.

••During elapsed time measurement, the stopwatch 1/20 second hand automatically rotates for the final second of each minute.

2.Press A to stop the stopwatch.

••You can resume the measurement operation by pressing A again.

3.Press A and the stopwatch 1/20 second hand will move to the 1/20 second count.

••If the elapsed time operation was stopped during the final second of each minute, the stopwatch 1/20 second hand will already be pointing at the

1/20 second count. Do not press A at this time, because doing so will restart the elapsed time operation.

4.Check the elapsed time.

••The example below shows an elapsed time of two minutes, 24.65 seconds.

 

Stopwatch 1/20 second hand

 

[.65]

Stopwatch minute hand

 

[2 minutes]

Stopwatch second hand

 

[24 seconds]

••Press B to reset the stopwatch. This will enter the Timekeeping Mode.

Notes:

••Do not try to perform stopwatch operations while the crown is pulled out either to the first or second click. If you try to press a button, you might accidentally cause the crown to rotate and change the current time or day setting.

••If the starting positions of the stopwatch second hand and 1/20 second hand become misaligned, use the following procedures to adjust the positions of the hands so they point to 12 o’clock when the stopwatch is reset.

To adjust the positions of the stopwatch hands

1.Press B to reset the stopwatch, and check the stopwatch second hand, 1/20 second hand, and minute hand. They all should be at 12 o’clock.

2.To adjust the hands, pull out the crown to the second click.

3.Press A to move the stopwatch second hand to 12 o’clock.

••Holding down A will move the second hand at high speed, until you release the button.

4.Press B to move the stopwatch 1/20 second hand to 12 o’clock.

••Holding down B will move the 1/20 second hand at high speed, until you release the button.

5.After making the adjustments you want, push the crown back in to its normal position. The stopwatch minute hand will move automatically to 12 o’clock.

••Note that pulling the crown out also stops the timekeeping second hand. After performing the above procedure, you should also adjust the timekeeping setting.

■For a watch with an elapsed time bezel

Rotate the elapsed time bezel to align the mark with the minute hand. After certain amount of time elapsed, read the graduation on the elapsed time bezel which the minute hand points to. The elapsed time is indicated.

Elapsed time bezel

••Some water resistant models are equipped with a screw lock crown.

••With such models, you must unscrew the crown in the direction noted in the illustration to loosen it before you can pull it out. Do not pull too forcibly on such crowns.

••Also note that such watches are not water resistant while their crowns are loosened. Be sure to screw the crowns back in as far as they will go after making any setting.

Specifications

Accuracy at normal temperature: ± 20 seconds a month

Display: 3 analog hands (timekeeping hour and minutes, stopwatch seconds),

3 dials (timekeeping seconds, stopwatch minutes and 1/20 seconds), day

Stopwatch function: Measuring capacity: 59'59.95" Measuring unit: 1/20 second Measuring mode: Elapsed time

Battery: One silver oxide battery (Type: SR927W)

Approximately 3 years on type SR927W (assuming one stopwatch operation 60 min./day)