Casio 2355, 2357, 2335 User Manual

Page 1
Module No.
A
L
7OO
0113
L
A
ENP
00OO
EAC
2307/2335/2355/2357
GENERAL GUIDE
Press C to change from mode to mode.
Holding down C in any mode for about one second returns to the normal
timekeeping screen.
Pressing C after performing some operation in the Recall Mode, Alarm
The configuration of your watch may differ somewhat from that shown in the illustration.
Timekeeping Mode
Press D.
A
0108
C
B
D
Press D.
Press C.
Stopwatch Mode
S
Press C.
Countdown Alarm Mode
A
630
Press C.
Press C.
Press D.
630
00OO
Pressing B in any mode besides the Countdown Alarm Mode or
Stopwatch Mode illuminates the display for about 1.5 second. The backlight is disabled while a setting screen is on the display.
For Module 2307 and 2357, the backlight illuminates both the digital display and analog face. For Module 2335 and 2355, the backlight illuminates the digital display only.
If you do not perform any operation for a few minutes while a setting screen (with flashing digits) is on the display, the watch automatically exits the setting screen.
If you do not perform any operation for about 10 hours in the Barometer Mode, Altimeter Mode, or Thermometer Mode, the watch automatically reverts to the Timekeeping Mode screen.
Barometer Mode
A8A0
Alarm Mode
Press C.
Press C.
2307/2335/2355/2357-1
Altimeter Mode
Press C.
Press C.
2150
815
215
0
Thermometer Mode
Recall Mode
TIMEKEEPING MODE
Pressing D changes the display in the sequence shown below.
Day of week
Press D.
Seconds
B
D
Crown
Press D.
A
0108
C
Hour : Minutes
PM indicator
The display type you select is used until you change it.
To set the time and date
1. While in the Timekeeping Mode, hold down A until the seconds digits
flash on the display.
2. Press C to move the selection (flashing) in the following sequence.
Seconds
3. While the seconds setting is selected (flashing), press D to reset it to 00. If you press D while the seconds setting is in the range of 30 to 59, the seconds are reset to 00 and 1 is added to the minutes. If the seconds setting is in the range of 00 to 29, the minutes count is unchanged.
While the 12/24-hour format setting is selected, press D to toggle it
between 12 and 24.
Hour
Month – Day
630
Press D.
630
Month – Day
Barometric pressure graph
*See “BAROMETER MODE”.
Minutes
12/24
YearMonthDay
When the 12-hour format is selected, the indicator P appears on the diaplay to indicate “p.m.” times. There is no indicator for “a.m.” times. Selecting the 24-hour format causes the 24 to appear on the display.
While any other setting is selected (flashing), press D to increase the number or B to decrease it.
Holding down either button changes the setting at high speed.
4. After you set the time and date, press A to change to the contrast setting
screen.
The indicator CNT appears on the left of the screen, and the value indicating the current contrast setting flashes on the right.
You can set the contrast to one of 11 levels in the range of –5 to +5.
5. Press D to make the display darker, or B to make it lighter.
6. After the contrast is the setting you want, press A to return to the normal
timekeeping screen.
The day of the week is automatically set in accordance with the date.
The date can be set within the range of January 1, 1995 to December 31,
2039.
The watch’s built-in full automatic calendar automatically makes allowances for different month lengths and leap years. Once you set the date, there should be no reason to change it except after the replacement of the watch’s battery.
To set the analog time
1. Pull the crown out to stop the second hand.
If you plan to restart analog timekeeping on some time signal (from the radio or television), pull the crown out when the second hand is at the 12 o’clock position.
2. Set the hands by turning the crown.
3. Push the crown back in to restart timekeeping.
Analog time is kept by a mechanical timepiece. Because of this, the second hand may not start to move exactly when you push the crown back in.
Page 2
2307/2335/2355/2357-2
ABOUT THE BACKLIGHT
This watch features an electroluminescent (EL) backlight that helps you easily read the face, even in total darkness. Its Auto Backlight function automatically lights the watch face whenever you turn your wrist towards your face.
For Module 2307 and 2357, the backlight
A
0108
C
Note
The backlight of the watch employs an electroluminescent (EL) light, which loses illuminating power after very long use.
Frequent use of the backlight shortens the battery life.
The illumination provided by the backlight may be hard to see when viewed
under direct sunlight.
The watch will emit an audible sound whenever the display is illuminated. It does not indicate malfunction of the watch.
The backlight automatically turns off whenever an alarm sounds.
To manually turn on the backlight
Pressing B in any mode besides the Countdown Alarm Mode or Stopwatch Mode illuminates the display for about 1.5 second. The backlight is disabled while a setting screen is on the display.
To switch the auto backlight function on and off
While in the Timekeeping Mode, hold down D for one second to turn the Auto Backlight function on and off.
Auto backlight indicator
The auto backlight indicator is shown on the display in all modes while the auto backlight function is on.
In order to protect against running down the battery, the auto backlight function is automatically turned off approximately six hours after you turn it on. Repeat the above procedure to turn the auto backlight function back on if you want.
Pressing B in any mode besides the Countdown Alarm Mode or Stopwatch Mode illuminates the display for about 1.5 second, regardless of the auto backlight function on/off setting.
About the Auto Backlight function
While the Auto Backlight function is turned on, the backlight automatically lights for about 1.5 second in any mode whenever you position your wrist as described below.
Important!
Avoid wearing the watch on the inside of your wrist. Doing so causes the Auto Backlight to operate when it is not needed, which shortens battery life.
Moving the watch to a position that is parallel to the ground and then tilting it towards you more than 40 degrees causes the backlight to illuminate.
The backlight may not illuminate if the face of the watch is more than 15 degrees off parallel as shown below. Make sure that the back of your hand is parallel to the ground.
Parallel to ground
B
illuminates both the digital display and analog face. For Module 2335 and 2355, the backlight illuminates the digital display only.
D
Hold down D.
8888
0108
D
ON OFF
Parallel to ground
More than 15 degrees too high
8888
0108
More than 15 degrees too low
D
More than 40°
Static electricity or magnetic force can interfere with proper operation of the auto backlight function. If the auto backlight does not illuminate, try moving the watch back to the starting position (parallel with the ground) and then tilt it back towards you again. If this does not work, drop your arm all the way down so it hangs at your side, and then bring it back up again.
Under certain conditions the backlight may not light until about one second or less after turn the face of the watch towards you. This does not necessarily indicate malfunction of the backlight.
Warning!
Never try to read your watch when mountain climbing or hiking in areas that are dark or in areas with poor footing. Doing so is dangerous and can result in serious personal injury.
Never try to read your watch when running where there is the danger of accidents, especially in locations where there might be vehicular or pedestrian traffic. Doing so is dangerous and can result in serious personal injury.
Never try to read your watch when riding on a bicycle or when operating a motorcycle or any other motor vehicle. Doing so is dangerous and can result in a traffic accident and serious personal injury.
When you are wearing the watch, make sure that its auto backlight function is turned off before riding on a bicycle or operating a motorcycle or any other motor vehicle. Sudden and unintended operation of the auto backlight can create a distraction, which can result in a traffic accident and serious personal injury.
BAROMETER MODE
This watch uses a pressure sensor to measure barometric pressure. It can be adjusted to correct for measurement error.
Important !
The barometer that is built into this watch measures changes in barometric pressure, which you can then apply to your own weather predictions. It is not intended for use as a precision instrument in official weather prediction or reporting applications.
Example barometer applications
Before going mountain climbing, you can take readings to predict upcoming weather.
You can predict the weather for golf or other outdoor activities.
About barometric pressure measurements
The watch takes barometric pressure measurements every five seconds for the first two minutes after you enter the Barometer Mode. The Barometer Mode indicator 1 flashes on the display during these two minutes. After the first two minutes, the Barometer Mode indicator 1 stops flashing, and the watch automatically takes measurements every two hours (starting from midnight). The watch continues to take barometric pressure readings every two hours, even if you change to another mode. Measurement data can be viewed on the Timekeeping Mode screen on the barometric pressure graph.
2
Last measurement
Barometer Mode indicator 1
A
A8A0
C
Remaining memory
Barometer Mode indicator 2
*1 The barometric pressure graph shows the barometric pressure readings
for the past 18 hours. The flashing point on the right of the display is the point of the last measurement.
*2 The displays show “– – – – hPa (or inHg) if a measured value falls outside
the range of 460 hPa/mb to 1100 hPa/mb (13.55 inHg to 32.45 inHg). The normal display will return as soon as the pressure returns with the allowable range.
B
D
(updated every two hours)
5 seconds later
Barometric pressure graph
0113
0113
*
Unit of measurement
Press A.
1
*
Page 3
2307/2335/2355/2357-3
2150
2150
400
Using the barometric pressure graph
Barometric pressure is affected by changes in weather and temperature. The following shows how to interpret the data that appears on the barometric pressure graph.
A rising graph generally means better weather.
A falling graph generally means deteriorating weather.
Note that if there are sudden changes in weather or temperature, the graph line of past measurements may run off the top or bottom of the display. The entire graph will become visible once barometric pressure conditions stabilize.
The following conditions cause the barometric pressure measurement to be skipped, with the corresponding point on the barometric pressure graph being left blank.
Barometric reading that is out of range (460 hPa/mb to 1100 hPa/mb/13.55 inHg to 32.45 inHg).
Sensor malfunction.
Dead battery.
Selecting the unit of measurement
1. Use C to enter the Barometer Mode.
2. Hold down A until “OFF” or the current barometric pressure value flashes
on the display.
3. Press C to change to the measurement unit selection screen.
4. Each press of D or B cycles the barometric pressure measurement unit
as shown below.
hPa
5. After you select the measurement unit you want, press A to return to the
Barometer Mode screen.
Note that all measurement data currently in memory is also deleted whenever you change the barometric pressure, altitude, or temperature unit of measurement.
mb
inHg
Calibrating the barometric pressure measurement
The sensor of this watch is calibrated at the factory before shipment, and further adjustment is normally not required. If noticeable error is found in the barometric pressure readings produced by the watch, you can adjust it to correct the error.
Important!
Incorrectly calibrating the barometric pressure measurement of this watch can result in incorrect readings. Compare the readings produced by the watch with those of another reliable, accurate barometer.
Calibrating the barometric pressure
1. Use C to enter the Barometer Mode.
2. Hold down A until “OFF” or the current barometric pressure calibration
value flashes on the display.
“OFF appears when the factory setting is currently set as the current barometric pressure calibration value.
3. Each press of D increases the displayed barometric pressure by 1 hPa/mb,
while pressing B decreases it. Holding down either button changes the value at high speed.
If inHg is currently selected as the unit of measurement, the above operations change the reading by 0.05 inHg.
Pressing B and D at the same time returns to the “OFF setting.
4. After calibrating the barometric pressure, press A to return to the
Barometer Mode screen.
ALTIMETER MODE
A built-in altimeter uses a pressure sensor to detect the current barometric pressure, which is then used to estimate the current altitude in accordance with ISA (International Standard Atmosphere) values for altitude and barometric pressure. If you preset a reference altitude, the watch will also calculate the current relative altitude based on your preset value.
Important !
This watch estimates altitude based on barometric pressure. This means that altitude readings for the same location may vary if barometric pressure changes.
Sudden changes in the weather make it impossible to produce accurate altitude readings.
This watch employs a semiconductor pressure sensor, which is affected by temperature changes. When taking altitude measurements, be sure to do so while ensuring that the watch is not exposed to temperature changes.
Do not use this watch while participating in sports where there are sudden altitude changes. Also, do not use this watch for applications that demand professional or industrial level precision. This watch should not be used while engaging in the following activities: skydiving, hang gliding, paragliding, gyrocopter riding, glider riding, etc.
Applications
When no reference altitude is preset:
The watch produces approximate altitude readings.
When a reference altitude is preset:
Before beginning the climb, set the reference altitude to 0 meter at the foot of the mountain. This makes it possible to determine the difference in altitude between the reference point and your destination.
To determine the height of a tall building, set the reference altitude to 0 meter on the ground floor. Note that you may not be able to get a good reading if the building is pressurized or air­conditioned.
To determine the difference in altitude between your house and another location, set the reference altitude to 0 meter at your house, and then check the reading when you arrive at the other location.
When mountain climbing, you can input the altitude from a marker as your reference altitude, which will then let you know your altitude as your climb proceeds. The following conditions will prevent you from obtaining accurate readings:
When barometric pressure changes because of changes in the weather Extreme temperature changes When the watch itself is subjected to strong impact
About altitude measurements
The watch measures altitude every five seconds for the first two minutes after you enter the Altimeter Mode. The Altimeter Mode indicator 1 flashes on the display during these two minutes. After the first two minutes, the Altimeter Mode indicator 1 stops flashing, and the watch automatically takes measurements every two minutes (on even numbered minutes). The display unit for Altimeter Mode measurements is 5 meters (20 feet), and the display range is 0 to 6,000 meters (0 to 19,680 feet).
The measured altitude may be a negative value in cases where there is a reference altitude value set or because of certain barometric pressure conditions.
Altimeter Mode indicator 1
A
L
A
C
Remaining memory
Altimeter Mode indicator 2
B
D
5 seconds later
Current altitude
Unit of measurement
Press A.
Altitude graph
Page 4
2307/2335/2355/2357-4
Selecting the measurement unit
1. Use C to enter the Altimeter Mode.
2. Hold down A until “OFF” or the current reference altitude value flashes on
the display.
3. Press C to change to the measurement unit selection screen.
4. Each press of D or B toggles the altitude measurement unit as shown
below.
m
5. After you select the measurement unit you want, press A to return to the
Altimeter Mode screen.
Note that all measurement data currently in memory is also deleted whenever you change the barometric pressure, altitude, or temperature unit of measurement
FT
Setting a reference altitude
After you set a reference altitude, the watch automatically calculates the difference between the current altitude and your preset value. The altitude measurements produced by this watch are subject to error caused by changes in barometric pressure. Because of this, we recommend that you set the reference altitude during your climb whenever one is available.
1. Use C to enter the Altimeter Mode.
2. Hold down A until “OFF” or the current reference altitude value flashes on
the display.
“OFF appears when the factory setting is currently set as the reference altitude value.
3. Each press of D increases the displayed altitude by 5 m, while pressing
B decreases it. Holding down either button changes the value at high speed.
If you have selected feet as your unit of measurement, the above operations change the reading by 20 feet.
You can set the reference altitude within the range of –6,000 meters to 6,000 meters (–19,680 feet to 19,680 feet).
Pressing B and D at the same time returns to the “OFF setting.
4. After setting the reference altitude you want, press A to return to the
Altimeter Mode screen.
THERMOMETER MODE
A built-in temperature sensor measures temperature and shows the measured value on the display. The thermometer can be calibrated to correct for errors.
Important!
Temperature measurements are affected by your body temperature (while you are wearing the watch), direct sunlight, and moisture. To achieve a more accurate temperature measurement, remove the watch from your wrist, place it in a well-ventilated location out of direct sunlight, and wipe off all moisture from the case. It takes approximately 20 to 30 minutes for the case of the watch to reach the temperature of the surrounding air.
About temperature measurements
The watch takes temperature measurements every five seconds for the first two minutes after you enter the Thermometer Mode. The Thermometer Mode indicator 1 flashes on the display during these two minutes. After the first two minutes, the Thermometer Mode indicator 1 stops flashing, and the watch automatically takes measurements every five minutes.
Understanding the temperature display
The display shows “– – . – °C” (or °F) if a measured value falls outside the range of –10.0°C to 60.0°C (14.0°F to 140.0°F). The normal display will return as soon as the temperature returns within the allowable range.
Thermometer Mode indicator 1
A
E NP
C
Remaining memory
Thermometer Mode indicator 2
B
D
2 seconds later
Temperature
Unit of measurement
815
815
Press A.
Selecting the measurement unit
1. Use C to enter the Thermometer Mode.
2. Hold down A until “OFF” or the current temperature calibration value
flashes on the display.
3. Press C to change to the measurement unit selection screen.
4. Each press of D or B toggles the temperature measurement unit as
shown below.
°C
5. After you select the measurement unit you want, press A to return to the
Thermometer Mode screen.
Note that all measurement data currently in memory is also deleted whenever you change the barometric pressure, altitude, or temperature unit of measurement.
°F
Calibrating the temperature measurement
The temperature sensor of this watch is calibrated at the factory before shipment, and further adjustment is normally not required. If noticeable error is found in the temperature readings produced by the watch, you can adjust it to correct the error.
Important!
Incorrectly calibrating the temperature measurement of this watch can result in incorrect readings. Carefully read the following before doing anything.
Compare the readings produced by the watch with those of another reliable, accurate thermometer.
If adjustment is required, remove the watch from your wrist and wait for 20 or 30 minutes to give the temperature of the watch time to stabilize.
Calibrating the temperature
1. Use C to enter the Thermometer Mode.
2. Hold down A until “OFF” or the current temperature calibration value
flashes on the display.
“OFF appears when the factory setting is currently set as the current temperature calibration value.
3. Each press of D increases the displayed temperature by 0.1°C, while
pressing B decreases it. Holding down either button changes the value at high speed.
If Fahrenheit is currently selected as the unit of measurement, the above operations change the reading by 0.2°F.
Pressing B and D at the same time returns to the “OFF setting.
4. After calibrating the temperature, press A to return to the Thermometer
Mode screen.
MEMORY
The watch is equipped with memory that you can use to store up to 10 barometric pressure, altitude, and temperature readings. Note that the date and time of the measurement is not included with the data. The number of available blank records that can be used to store data is shown on the right side of the Barometer, Altimeter, and Thermometer Mode screens.
Storing a Measurement
While in the Barometer, Altimeter, or Thermometer Mode, hold down D for about one second until the watch beeps, indicating that the latest measurement is stored in memory.
The message “FULL appears on the display for about one second when you hold down D while memory is full. No more data can be stored while memory is full.
If you want to store more data after memory becomes full, use the procedure under Recall Mode below to delete the current data to make room for new data.
Temperature graph
Page 5
2307/2335/2355/2357-5
Minutes Seconds Auto repeat ON/OFF
00OO
RECALL MODE
Recalling data
1. Use C to enter the Recall Mode.
2. Each press of D cycles through the barometric pressure, altitude, and
temperature data in memory. Mode indicators appear to tell you what type of data is currently displayed.
Note that measurement units are not indicated on the Recall Mode screens.
• The display shows “- - - - – –” if there is no data.
1 second
A
EAC
C
Recall Mode indicator
B
later
D
Altitude
0
215
Memory number
Deleting Data
While in the Recall Mode, hold down A. The watch beeps, and the message CLR flashes
LCA
on the display to indicate data is about to be deleted. Keep A depressed for about two seconds to delete all the measurement data currently in memory.
Note that this procedure deletes all measurement data in memory. You cannot delete individual records.
ALARM MODE
When the Daily Alarm is turned on, the alarm sounds for 20 seconds at the preset time each day. Press any button to stop the alarm after it starts to sound. When the Hourly Time Signal is turned on, the watch beeps every hour on the hour.
1 second
A
A
L
C
Alarm Mode indicator
B
later
D
To set the alarm time
1. Hold down A until the hour digits start to flash on the display. The hour
digits flash because they are automatically turned on.
2. Press C to change the selection in the sequence shown below.
Hour
3. Press D to increase the number or B to decrease it.
Holding down either button changes the setting at high speed.
4. After you set the alarm time, press A to return to the Alarm Mode screen.
The format (12-hour and 24-hour) of the alarm time matches the format you select for normal timekeeping.
When setting the alarm time using the 12-hour format, take care to set the time correctly as morning or afternoon.
To stop the alarm
Press any button to stop the alarm after it starts to sound.
To turn the Daily Alarm and Hourly Time Signal on and off
Press D while in the Alarm Mode to change the status of the Daily Alarm and Hourly Time Signal in the sequence shown below.
Alarm time
7OO
Hourly time signal on indicator
Alarm on indicator
selected
. At this time the alarm is
Minutes
COUNTDOWN ALARM MODE
The countdown alarm can be set within a range of 10 seconds to 60 minutes. When the countdown reaches zero, an alarm sounds for 10 seconds or until you press any button.
1 second
A
A
C
Countdown Alarm Mode indicator
B
later
D
Minutes
00OO
Seconds
1/10 second
To set the countdown start time and auto repeat function on and off
1. Hold down A while in the Countdown Alarm Mode. The minutes setting
flashes on the display because it is
2. Press C to change the selection in the sequence shown below.
3. Press D to increase the selected setting or B to decrease it. Holding
down either button changes the setting at high speed.
The seconds can be set in units of 10 seconds.
Set 0 minutes, 0 seconds to specify a start time of 60 minutes.
While the AUTO ON/OFF setting is selected (flashing), press D or B to
toggle auto repeat on and off.
4. After you set the countdown start time and auto repeat ON/OFF setting,
press A to return to the Countdown Alarm Mode screen.
Auto repeat ON Auto repeat OFF
01OO
Auto repeat ON indicator
selected
.
01OO
To use the countdown alarm
1. Press D while in the Countdown Alarm Mode to start the countdown
alarm operation.
2. Press D again to stop the countdown alarm operation.
You can resume a paused countdown alarm operation by pressing D.
3. Stop the countdown alarm and then press B to reset the countdown time
to its starting value.
When the end of the countdown is reached and auto repeat is off, the alarm sounds for 10 seconds or until you stop the alarm by pressing any button. Countdown timing stops and the countdown time is automatically reset to its starting value after the alarm stops.
When the end of the countdown is reached while auto repeat is on, the alarm sounds, but the countdown restarts from the beginning without stopping. You can stop the countdown by pressing D and manually reset to the start time by pressing B.
When the start time is less than one minute and auto repeat is turned on, the countdown alarm tone sounds for only one second instead of the normal 10 seconds.
STOPWATCH MODE
The Stopwatch Mode lets you record elapsed time, split times, and two finishes. The range of the stopwatch is 59 minutes, 59.99 seconds. Stopwatch functions are available in the Stopwatch Mode, which you can enter using C.
1 second
A
S
C
Stopwatch Mode indicator
B
later
D
1/100 second
Seconds
Minutes
Both ON
Both OFF
The alarm and hourly time signal indicator is displayed in all modes.
To test the alarm
Hold down D while in the Alarm Mode to sound the alarm.
Daily Alarm only
Hourly Time Signal only
(a) Elapsed time measurement
DDB
(b) Split time measurement
DDB
Start Stop Clear
(c) Split time and 1st-2nd place times
DBB
Start Split release
D
Stop
B
Split
B
Split
First runner finishes.
D
Re-start
B
Split release
D
Stop
Second runner finishes. Record time of first runner.
Stop ClearStart
Record time of second runner.
Clear
Page 6
2307/2335/2355/2357-6
BATTERY REPLACEMENT
ALWAYS LEAVE BATTERY REPLACEMENT UP TO THE DEALER WHERE YOU BOUGHT THE WATCH OR TO AN AUTHORIZED CASIO DISTRIBUTOR. BE SURE TO SHOW THE FOLLOWING INFORMATION TO THE PERSON REPLACING THE BATTERY.
Attention dealer or CASIO distributor
Be sure to use the following procedure when replacing the battery.
1. Remove the back cover screws, and then remove the back cover.
2. Pull up the battery holder.
3. Remove the old battery and load a new one.
4. Close the battery holder.
5. Touch the AC contact and the battery (+) side with metallic tweezers.
6. Replace the back cover and secure it with the screws.
7. Check the display of the watch. If the message OPEn is on the display, it means the back cover is not closed correctly. Remove the back cover and carefully replace it again.
* Absence of the OPEn message does not necessarily indicate an air-tight
seal. Other tests are required to check for air tightness.
WARNING INDICATORS
This watch displays warning indicators to let you know when the sensor is malfunctioning and when battery power is low.
Err Display – Sensor Malfunction Warning
This message indicates malfunction of the watchs pressure sensor circuitry. When sensor malfunction initially occurs, the watch stops taking measurements, the Err message appears, and a buzzer sounds for about three seconds.
If the sensor is malfunctioning when it comes time for a barometric pressure
measurement to be taken, the barometric pressure value and altitude value appears as “– – – –” on the display and the corresponding point on the barometric pressure graph is left blank.
Whenever there is a sensor malfunction, be sure to take the watch to an
authorized CASIO distributor or Service Center as soon as possible.
Alteration of and Graph – Temporary Low Power Warning
Temporary low power is indicated on the display when the battery level temporarily drops below a certain level.
Sensors are disabled while the temporary low power warning is being
indicated, but the light and tones are operational.
Very low temperature can cause the low power warning to appear even
though battery power is not low. The low power warning should disappear when the watch is restored to normal temperature.
If the low power warning appears under normal temperature, replace the
battery as soon as possible.
Alteration of and – Battery Usage Warning
The watch automatically monitors your use of certain high battery drain functions. The battery usage warning display appears whenever the watch determines that your use of these functions is putting a heavy load on the battery.
Sensors, the light, and tones are disabled while the battery usage warning
is on the display.
The following are the trigger values for the functions that are monitored for
battery usage.
The battery usage warning appears whenever any single function is
performed the number of times noted above, or for any proportional number of operations of multiple functions (such as 50 light operations and 50 alarm operations, 50 light operations and 500 mode change operations, etc.).
The monitor counter continues to be incremented as long as the duration
between two high power drain operations is less than 15 minutes. The counter is reset to 0 whenever 15 minutes pass between operations.
Light: 100 Sensor Operations: 1,000 Alarm: 100 Mode Change: 1,000
ABOUT ALTITUDE AND BAROMETRIC
PRESSURE MEASUREMENTS
Altimeter
Generally, barometric pressure and temperature decrease as altitude increases. This watch bases its altitude measurements on International Standard Atmosphere (ISA) values stipulated by the International Civil Aviation Organization (ICAO), which define relationships between altitude, barometric pressure, and temperature.
ALTITUDE BAROMETRIC PRESSURE TEMPERATURE
6000 m
5500 m
5000 m
4500 m
4000 m
3500 m
3000 m
2500 m
2000 m
1500 m
1000 m
500 m
0 m
Source: International Civil Aviation Organization
ALTITUDE TEMPERATURE
20000 ft
18000 ft
16000 ft
14000 ft
12000 ft
10000 ft
8000 ft
6000 ft
4000 ft
2000 ft
0 ft
Source: International Civil Aviation Organization
There are two standard methods of expressing altitude: Absolute altitude and relative altitude. Absolute altitude expresses an absolute height above sea level. Relative altitude expresses the difference between the height of two different places.
Barometer
Barometric pressure indicates changes in the atmosphere, and by monitoring these changes you can predict the weather with reasonable accuracy. Rising barometric pressure indicates good weather, while falling pressure indicates deteriorating weather conditions.
The barometric pressures that you see in the newspaper and on the TV weather report are measurements corrected to values measured at 0 m sea level.
472 hPa/mb
540 hPa/mb
616 hPa/mb
701 hPa/mb
795 hPa/mb
899 hPa/mb
1013 hPa/mb
BAROMETRIC PRESSURE
13.76 inHg
16.22 inHg
19.03 inHg
22.23 inHg
25.84 inHg
About 6.7 hPa/mb per 100 m
About 7 hPa/mb per 100 m
About 8 hPa/mb per 100 m
About 9 hPa/mb per 100 m
About 10 hPa/mb per 100 m
About 11 hPa/mb per 100 m
About 12 hPa/mb per 100 m
About 0.119 inHg per 200 ft
About 0.1315 inHg per 200 ft
About 0.15 inHg per 200 ft
About 0.17 inHg per 200 ft
About 0.192 inHg per 200 ft
About 0.21 inHg per 200 ft
Height of building 130 m (Relative altitude)
24°C
17.5°C
11°C
About 6.5°C
–4.5°C
per 1000 m
2°C
8.5°C
15°C
–12.2°F
2.0°F
16.2°F About 3.6°F
per 1000 ft
30.5°F
44.7°F
59.0°F29.92 inHg
Rooftop at an altitude of 230 m above sea level (Altitude above sea level)
Sea
Display – Low Power Warning
The low power warning appears to let you know that battery power is low.
Sensors, the light, and tones are disabled while the low power warning is on the display.
The low power warning may appear under very low temperatures, although battery power is not low. Correct operation should resume when the watch returns to normal temperature.
If the low power warning appears under normal temperatures, have the watchs battery replaced as soon as possible.
Be sure to read “BATTERY REPLACEMENT before trying to replace the
battery.
Loading...