CAS IE-100, IE-500, IE-200, IE-2000, IE-1000 Owner's Manual

Page 1
2
Page 2
3
CONTENTS
SAFETY GUIDE
4
PRECAUTION
...................................................
4
PRODUCT CHARACTERISTICS
................
5
SPECIFICATION
..............................................
5
MODEL
...............................................................
6
SIZE AND NET WEIGHT
...............................
7
OPERATION
......................................................
8
ELECTRICAL PRINCIPLE DIAGRAM
...
10
DISPLAY MESSAGE
.....................................
11
TROUBLESHOOTING
.................................
12
REMOTE CONTROLLER
...........................
13
Page 3
4
SAFETY GUIDE
Read carefully the following instruction and advice before using this scale.
Over-loading this scale is harshly prohibited
Refrain from long-time loading that could lead to excessive fat igue on loadcell
used inside the scale. Excessive fa tigue that on lo adcell would decrease the accuracy and shorten the life of s cale.
Check the shackle and hook regularly.
Check the battery power level before/after use and r echarge th e scale in tim e.
In order to maximize the battery life, periodic recharging is necessary for scales ev en not
in use for long time.
Do not try to repair the scale by yourselves.
Use privately attached charger only .
PRECAUTION
The crane scale is a kind of precise weighing instrument, pay attention on
operantion and maintenance.
Rotate the load instead of machine otself if necessary for operat ion.
Stop using the machine under the circumstances of thunder & rain.
Check periodicly if the clips/pins and screws of the machine are loose or broken
before use.
If low battery signal appeare & LED annunciator goes green while charging,
please check the battery.
Hang the machine instrad for storage while not in use in order to prev ent from
unnecessary load in the weight sensor inside.
Do not subject the scale to sudden to sudden temperature changes.
Avoid from the shock of excessive weight.
Page 4
5
PRODUCT CHARACTERISTICS
Model Display characteristics
30mm(1.2″)LED
IE Series
30mm(1.2″)LCD
High accuracy, small volume,
easy to bring
High quality: The process management is operated according to OIML R76,
GB/T11883-2002, and get the European CE certificate.
Safty installation: Aluminum Die-Casting Case, high intensity hook and shackle,
special loadcell for safty installation.
High reliability: Using high quality components on PCB circul board to board to insure
long time stability.
Broad applicability: 30mm high character display , 25M distance eyeshot, can be used
in storage industry, textile industry, metallurg y industry etc.
Simple operation: Check battry voltage automatic ally, wireless remote controller ,
separate battery space, small volume, easy to bring.
Complete function: Kg/Lb conversion, Hold, T are, Division choice, S tablity regulation,
Accumulation/Search, Gross/Net conversion, parameter regulation etc.
SPECIFIC ATION
Standard
GB/T11883-2002《Electrical Crane Scale
Accuracy class
OIML class III
Display
30mm(1.2) 5digits LCD/LED
Zero Range
4% full capacity
T are Range
100% Full capacity
Stable Time
10 seconds
Overload Indication
100% Max. capacity + 9e
Max. Safety Load
125% Max. capacity
Ultimate Load
400% Max. capacity
Battery Life
50 hours
Battery Ty pe
Fully sealed Lead-Acid battery, 6V/5Ah
Adapter
DC9V/1500mA
Operating Temp.
- 10 ~ + 40℃℃
Page 5
6
Operating Humidity
85% RH under 20
Remote Controller Distance
Min. 10m
Battery of Remote Controller
5# battery, 1.5V 2
MODEL
Model
Max. capacity
(kg / lb)
Min. capacity
(kg / lb)
Division
(kg / lb)
T otal display
(kg / lb)
IE-100
50/100 0.5/1 0.02/0.05 n=2000
IE-200 100/200 1/2 0.05/0.1 n=2000
IE-500 200/500 2/4 0.1/0.2 n=2500
IE-1000 500/1000 4/10 0.2/0.5 n=2000
IE-2000 1000/2000 10/20 0.5/1 n=2000
Page 6
7
SIZE AND NET WEIGHT
Max.Capacity
L
(mm)
A
(mm)
B
(mm)
C
(mm)
Net
weight
100kg
335 20 65 20 4.0
200kg 335 20 65 20 4.0
300kg 335 20 65 20 4.0
500kg 360 25 75 20 4.2
1000kg 360 25 75 20 4.2
Notice: If there’s any modification, all the date are subject to the scale itself.
Page 7
8
OPERATION
TURN ON
Operation Display Illustration
OFF/ON 【 8.8.8.8.8
Display two times
500.0
Display capacity two times
U X.XX
Display the voltage of battery
- - - - -
Wait stable signal
0
“STB” light, can hang the weight
Notice: T o guarantee th e accuracy, leave scale alone for 3~5 minutes after turning on.
ZERO
Operation Display Illustration
Press→0】on scale 【 0 Press ZERO on
controller
0
After turn on, generally display
0】, if not for 【 0
Can operate like this
T ARE
Operation Display Illustration
Press→T】on scale 【 0 Press TA R E on
controller
0
Press this key to deduct the weight of Container, while “TARE” light on, the Scale will show the net weight of load
Notice: As crane sca le deduct the weigh t of container au tomatically, so it will show the
net weight of load every time, you needn’ t press this ke y to get net weig ht until you ch ange the container or turn off.
OVERLOAD W ARNING
The display will show【-OL-】once the load (Net + T are) exceeds Max. capacity . Make sure that the load are within the capacity range, otherwise it’ s very dangerous.
Page 8
9
CHECK BA TTER Y
Press【OFF/ON】on scale, when turn on or turn off, it shows【U X.XX Press 【OFF】on controller 2 seconds Stable after 15 minute, it show】, after 60minutes, it turn off automatically.
HOLD THE WEIGHT READING
Press “HOLD” key on the remote controller to hold the displayed weight reading. At this moment, “HOLD” light on, Press this key again will disable hold function.
LOW BA T TER Y WARNING
When the battery voltage lowe r then【U 5.8.0】, the display flash, but the scal e can still work until the display show 【 -Lb- 】, one minute later , it will turn off automatically , you need to rechar ge the battery to
use again.
POWER SA VING
The display will show 】when the load are at stable status in exc ess of 15 minutes and revert to normal weighing readings while load changes. When the load are at stable status in excess of 60 minutes, the s cale will turn of f automat ically
RECHARGING BA TTER Y
1. Turn off, connect the adapter with 220V AC pow er supply , also insert the plug in the socket which located in the rear of scal e. The light become green, it means it’ s rechar ging automatically , until the green light become red, that means recharging is finished.
2. When you need to use crane scale hour after hour , take of f the rear cover , change the battery with recharged battery.
Attention : Generally , the time of recharging should not low er than 8 hours, this scale have rechar ging protection function, long time recharging will not damage the battery .
TURN OFF
Press【OFF/ON】on scale 2 seconds Press【OFF】on controller 2 seconds Stable after 15minutes, it show】, after 60minutes, it turn off automatically.
Page 9
10
ELECTRICAL PRINCIPLE DIAGRAM
Control key
Control distance
Load cell
Signal enlarges
A/D
CPU
LED or LCD display
Battery
Page 10
11
DISPLAY MESSAGE
Display Illustration
- - - - -】 Waiting stable
【 Err10】 Accumulated weight not exceed Min. Capacity 【 Err11】 Accumulated times exceed, (can’t accumulate after 30times) 【 Err12】 Accumulated weight exceed (can’t accumulate after 99999) 【 CLr】 Ask if you really want to delete accumulated weight, in case error deletion
noCLr】 Give up deletion
88888】 Confirm deletion
noACC】 No any accumulated value (when you check)
SHIFt】 Conversion, when you press SHIFT in controller
UX.XX】 The voltage of current battery
SCALE】 Enter weight adjustment
SEtUP】 Enter parameter adjustment
UAdJ 】 Enter voltage adjustment
-OL- 】 Overload warning
-Lb- 】 Low battery warning
End 】 End, when parameter adjustment ready
OFF 】 Turn off
Page 11
12
TROUBLESHOOTING
Phenomenon Reason Solution
Battery damaged Check battery
No display when Turn on
Battery contact loosed Tighten the contact
Display flash Low battery Min.Capacity Recharge the battery
Can’t trun on & off 【OFF/ON】Abuttun damaged Check & clean the buttun Can’t tare 【TA RE】Abuttun damaged Check & clean the buttun
The recharger damaged
Check the recharger
Recharge indicator Light can’t turn on
The recharger isn’t plugged ready
Insert plug again
The load is unstable Stablize the load
Loadcell cable damaged
Check and replace loadcell
Display isn’t stable
The scale in damp Environment for a long time
Put the scale in dry
Environment No enough time for heating the scale after turn on
After turning on, heating
3-5 minutes.
The display don’t show “0” when empty load
Put the scale on ground for too long time
Scale should be hung
The error is large
The scale isn’t hung properly
Check the scale and sling
Battery damaged Replace battery
Battery can’t recharge
Outlet damaged Replace the outlet
Receiver window is too dirty
Check and clean
Remote distance
shorten
Low battery of controller
Replace controller battery
Page 12
13
REMOTE CONTROLLER GUIDE
Lightness of display
Operation Illustration
F1】 0~5, 0: no display, 1: Minimum light, 5: Maximum light (Default: 2)
ZERO
Operation Illustration
ZERO】 display
0〗 when no load, “ZERO” light on
HOLD
Operation Illustration
【HOLD】 Hold the weight, “HOLD” light on 【HOLD】 Convert to weighing situation, “HOLD” light off
TARE
1. T are directly
Operation Illustration
【TA RE】 Display show net weight, “TARE” light on 【TA RE】 Display show gross weight, “TARE” light off
2. Set tare weight in advance
Operation display Illustration
【 MR 】 【SHIFT】
TA RE】 00000】 Current tare weight
【 ****】 Input the tare weight
【 MR 】 【 - ***】
Exit, “TARE” light on, it will deduct tare weight automatically when weighing.
Page 13
1
4
ACCUMULATION
Operation display Illustration
M+ 【No*** Current accumulation times 【H**** Rear four digit of current accumulated value 【L**** Front four digit of current accumulated value
Attention: After dis play two times circlely , it will return to weigh situation automatically , you also can press MR to return directly.
SEARCH
Operation display Illustration
【 MR 】 【No***】 Current accumulation times
【 M+ 】 【*****】 Current weight
【H**** Rear four digit of current accumulated value 【L**** Front four digit of current accumulated value
MR 【 0 Return to weigh
Attention: Press【TARE】and 【→0←】can search every time weight and accumulated value, press 【 MR 】return.
CLEAR
Operation dis play Illustration
【CLEAR】 【 CLr 】
Display blink, please confirm if you want to delete Accumulated value
CLEAR】 noCLr】 Cancel deletion
MR 】 88888】 Confirm deletion
ZERO DISPLAY
Operation display Illustration
【 MR 】 【SHIFT】
【→0←】 【 ***】 Display current zero value
Page 14
15
KG/LB CONVERSION
Operation display Illustration
MR 】 SHIFT】
CLEAR】 Un= *】
Un = 0 : kg “lb” light off
Un = 1 : kg “lb” light on,
SEARCH OVERLOAD TIMES
Operation display Illustration
【 MR 】 【SHIFT】
CLEAR】 OL=**】 Display times of overload
VOLTAGE DISPLAY
Operation display Illustration
【 MR 】 【SHIFT】
F1 】 U X.XX】 Display show current voltage of the battery
【 MR 】 【 0】 Return to weigh
TURN OFF
Operation display Illustration
OFF 【 OFF
【U X.XX
Display show current voltage of battery then turn off
Page 15
16